-
Diffusion MRI with free gradient waveforms on a high-performance gradient system: Probing restriction and exchange in the human brain
Authors:
Arthur Chakwizira,
Ante Zhu,
Thomas Foo,
Carl-Fredrik Westin,
Filip Szczepankiewicz,
Markus Nilsson
Abstract:
The dependence of the diffusion MRI signal on the diffusion time carries signatures of restricted diffusion and exchange. Here we seek to highlight these signatures in the human brain by performing experiments using free gradient waveforms that are selectively sensitive to the two effects. We examine six healthy volunteers using both strong and ultra-strong gradients (80, 200 and 300 mT/m). In an…
▽ More
The dependence of the diffusion MRI signal on the diffusion time carries signatures of restricted diffusion and exchange. Here we seek to highlight these signatures in the human brain by performing experiments using free gradient waveforms that are selectively sensitive to the two effects. We examine six healthy volunteers using both strong and ultra-strong gradients (80, 200 and 300 mT/m). In an experiment featuring a large set of gradient waveforms with different sensitivities to restricted diffusion and exchange (150 samples), our results reveal unique time-dependence signatures in grey and white matter, where the former is characterised by both restricted diffusion and exchange and the latter predominantly exhibits restricted diffusion. Furthermore, we show that gradient waveforms with independently varying sensitivities to restricted diffusion and exchange can be used to map exchange in the human brain. We consistently find that exchange in grey matter is at least twice as fast as in white matter, across all subjects and all gradient strengths. The shortest exchange times observed in this study were in the cerebellar cortex (115 ms). We also assess the feasibility of future clinical applications of the method used in this work, where we find that the grey-white matter exchange contrast obtained with a 25-minute 300 mT/m protocol is preserved by a 4-minute 300 mT/m and a 10-minute 80 mT/m protocol. Our work underlines the utility of free waveforms for detecting time-dependence signatures due to restricted diffusion and exchange in vivo, which may potentially serve as a tool for studying diseased tissue.
△ Less
Submitted 5 April, 2023;
originally announced April 2023.
-
A Registration- and Uncertainty-based Framework for White Matter Tract Segmentation With Only One Annotated Subject
Authors:
Hao Xu,
Tengfei Xue,
Dongnan Liu,
Fan Zhang,
Carl-Fredrik Westin,
Ron Kikinis,
Lauren J. O'Donnell,
Weidong Cai
Abstract:
White matter (WM) tract segmentation based on diffusion magnetic resonance imaging (dMRI) plays an important role in the analysis of human health and brain diseases. However, the annotation of WM tracts is time-consuming and needs experienced neuroanatomists. In this study, to explore tract segmentation in the challenging setting of minimal annotations, we propose a novel framework utilizing only…
▽ More
White matter (WM) tract segmentation based on diffusion magnetic resonance imaging (dMRI) plays an important role in the analysis of human health and brain diseases. However, the annotation of WM tracts is time-consuming and needs experienced neuroanatomists. In this study, to explore tract segmentation in the challenging setting of minimal annotations, we propose a novel framework utilizing only one annotated subject (subject-level one-shot) for tract segmentation. Our method is constructed by proposed registration-based peak augmentation (RPA) and uncertainty-based refining (URe) modules. RPA module synthesizes pseudo subjects and their corresponding labels to improve the tract segmentation performance. The proposed URe module alleviates the negative influence of the low-confidence voxels on pseudo subjects. Experimental results show that our method outperforms other state-of-the-art methods by a large margin, and our proposed modules are effective. Overall, our method achieves accurate whole-brain tract segmentation with only one annotated subject. Our code is available at https://github.com/HaoXu0507/ISBI2023-One-Shot-WM-Tract-Segmentation.
△ Less
Submitted 25 March, 2023;
originally announced March 2023.
-
TractoFormer: A Novel Fiber-level Whole Brain Tractography Analysis Framework Using Spectral Embedding and Vision Transformers
Authors:
Fan Zhang,
Tengfei Xue,
Weidong Cai,
Yogesh Rathi,
Carl-Fredrik Westin,
Lauren J O'Donnell
Abstract:
Diffusion MRI tractography is an advanced imaging technique for quantitative map** of the brain's structural connectivity. Whole brain tractography (WBT) data contains over hundreds of thousands of individual fiber streamlines (estimated brain connections), and this data is usually parcellated to create compact representations for data analysis applications such as disease classification. In thi…
▽ More
Diffusion MRI tractography is an advanced imaging technique for quantitative map** of the brain's structural connectivity. Whole brain tractography (WBT) data contains over hundreds of thousands of individual fiber streamlines (estimated brain connections), and this data is usually parcellated to create compact representations for data analysis applications such as disease classification. In this paper, we propose a novel parcellation-free WBT analysis framework, TractoFormer, that leverages tractography information at the level of individual fiber streamlines and provides a natural mechanism for interpretation of results using the attention mechanism of transformers. TractoFormer includes two main contributions. First, we propose a novel and simple 2D image representation of WBT, TractoEmbedding, to encode 3D fiber spatial relationships and any feature of interest that can be computed from individual fibers (such as FA or MD). Second, we design a network based on vision transformers (ViTs) that includes: 1) data augmentation to overcome model overfitting on small datasets, 2) identification of discriminative fibers for interpretation of results, and 3) ensemble learning to leverage fiber information from different brain regions. In a synthetic data experiment, TractoFormer successfully identifies discriminative fibers with simulated group differences. In a disease classification experiment comparing several methods, TractoFormer achieves the highest accuracy in classifying schizophrenia vs control. Discriminative fibers are identified in left hemispheric frontal and parietal superficial white matter regions, which have previously been shown to be affected in schizophrenia patients.
△ Less
Submitted 10 July, 2022; v1 submitted 5 July, 2022;
originally announced July 2022.
-
Probing restricted diffusion and exchange using free gradient waveforms: validation by numerical simulations
Authors:
Arthur Chakwizira,
Carl-Fredrik Westin,
Jan Brabec,
Samo Lasič,
Linda Knutsson,
Filip Szczepankiewicz,
Markus Nilsson
Abstract:
Monitoring time-dependence with diffusion MRI yields observables sensitive to compartment sizes (restricted diffusion) and membrane permeability (water exchange). However, restricted diffusion and exchange have opposite effects on the diffusion-weighted signal, which can confound parameter estimates. In this work, we present a signal representation that captures the effects of both restricted diff…
▽ More
Monitoring time-dependence with diffusion MRI yields observables sensitive to compartment sizes (restricted diffusion) and membrane permeability (water exchange). However, restricted diffusion and exchange have opposite effects on the diffusion-weighted signal, which can confound parameter estimates. In this work, we present a signal representation that captures the effects of both restricted diffusion and exchange up to second order in b-value and is compatible with gradient waveforms of arbitrary shape. The representation features map**s from a gradient waveform to two scalars that separately control the sensitivity to restriction and exchange. We demonstrate that these scalars span a two-dimensional space that can be used to choose waveforms that selectively probe restricted diffusion or exchange, in order to eliminate the correlation between the two phenomena. We found that waveforms with specific but unconventional shapes provide an advantage over conventional pulsed and oscillating gradient acquisitions. We also show that parametrisation of waveforms into a two-dimensional space can be used to understand protocols from other approaches that probe restricted diffusion and exchange. For example, we find that the variation of mixing time in filter-exchange imaging corresponds to variation of our exchange-weighting scalar at a fixed value of the restriction-weighting scalar. Numerical evaluation of the proposed signal representation using Monte Carlo simulations on a synthetic substrate showed that the theory is applicable to sizes in the range 2 - 7 micrometres and barrier-limited exchange in the range 0 - 20 s$^{-1}$. The presented theory constitutes a simple and intuitive description of how restricted diffusion and exchange influence the signal as well as how to design a protocol to separate the two effects.
△ Less
Submitted 22 November, 2021;
originally announced November 2021.
-
SNR-enhanced diffusion MRI with structure-preserving low-rank denoising in reproducing kernel Hilbert spaces
Authors:
Gabriel Ramos-Llordén,
Gonzalo Vegas-Sánchez-Ferrero,
Congyu Liao,
Carl-Fredrik Westin,
Kawin Setsompop,
Yogesh Rathi
Abstract:
Purpose: To introduce, develop, and evaluate a novel denoising technique for diffusion MRI that leverages non-linear redundancy in the data to boost the SNR while preserving signal information. Methods: We exploit non-linear redundancy of the dMRI data by means of Kernel Principal Component Analysis (KPCA), a non-linear generalization of PCAto reproducing kernel Hilbert spaces. By map** the sign…
▽ More
Purpose: To introduce, develop, and evaluate a novel denoising technique for diffusion MRI that leverages non-linear redundancy in the data to boost the SNR while preserving signal information. Methods: We exploit non-linear redundancy of the dMRI data by means of Kernel Principal Component Analysis (KPCA), a non-linear generalization of PCAto reproducing kernel Hilbert spaces. By map** the signal to a high-dimensional space, better redundancy is achieved despite nonlinearities in the data thereby enabling better denoising than linear PCA. We implement KPCA with a Gaussian kernel, with parameters automatically selected from knowledge of the noise statistics, and validate it on realistic Monte-Carlo simulations as well as with in-vivo human brain submillimeter resolution dMRI data. We demonstrate KPCA denoising using multi-coil dMRI data also. Results: SNR improvements up to 2.7 X were obtained in real in-vivo datasets denoised with KPCA, in comparison to SNR gains of up to 1.8 X when using state-of-the-art PCA denoising, e.g., Marchenko- Pastur PCA (MPPCA). Compared to gold-standard dataset references created from averaged data, we showed that lower normalized root mean squared error (NRMSE) was achieved with KPCA compared to MPPCA. Statistical analysis of residuals shows that only noise is removed. Improvements in the estimation of diffusion model parameters such as fractional anisotropy, mean diffusivity, and fiber orientation distribution functions (fODFs)were demonstrated. Conclusion:Non-linear redundancy of the dMRI signal can be exploited with KPCA, which allows superior noise reduction/ SNR improvements than state-of-the-art PCA methods, without loss of signal information.
△ Less
Submitted 14 September, 2020;
originally announced September 2020.
-
Gradient waveform design for tensor-valued encoding in diffusion MRI
Authors:
Filip Szczepankiewicz,
Carl-Fredrik Westin,
Markus Nilsson
Abstract:
Diffusion encoding along multiple spatial directions per signal acquisition can be described in terms of a b-tensor. The benefit of tensor-valued diffusion encoding is that it unlocks the "shape of the b-tensor" as a new encoding dimension. By modulating the b-tensor shape, we can control the sensitivity to microscopic diffusion anisotropy which can be used as a contrast mechanism; a feature that…
▽ More
Diffusion encoding along multiple spatial directions per signal acquisition can be described in terms of a b-tensor. The benefit of tensor-valued diffusion encoding is that it unlocks the "shape of the b-tensor" as a new encoding dimension. By modulating the b-tensor shape, we can control the sensitivity to microscopic diffusion anisotropy which can be used as a contrast mechanism; a feature that is inaccessible by conventional diffusion encoding. Since imaging methods based on tensor-valued diffusion encoding are finding an increasing number of applications we are prompted to highlight the challenge of designing the optimal gradient waveforms for any given application. In this review, we first establish the basic design objectives in creating field gradient waveforms for tensor-valued diffusion MRI. We also survey additional design considerations related to limitations imposed by hardware and physiology, potential confounding effects that cannot be captured by the b-tensor, and artifacts related to the diffusion encoding waveform. Throughout, we discuss the expected compromises and tradeoffs with an aim to establish a more complete understanding of gradient waveform design and its impact on accurate measurements and interpretations of data.
△ Less
Submitted 17 November, 2020; v1 submitted 15 July, 2020;
originally announced July 2020.
-
Magnetic resonance assessment of effective confinement anisotropy with orientationally-averaged single and double diffusion encoding
Authors:
Cem Yolcu,
Magnus Herberthson,
Carl-Fredrik Westin,
Evren Özarslan
Abstract:
Porous or biological materials comprise a multitude of micro-domains containing water. Diffusion-weighted magnetic resonance measurements are sensitive to the anisotropy of the thermal motion of such water. This anisotropy can be due to the domain shape, as well as the (lack of) dispersion in their orientations. Averaging over measurements that span all orientations is a trick to suppress the latt…
▽ More
Porous or biological materials comprise a multitude of micro-domains containing water. Diffusion-weighted magnetic resonance measurements are sensitive to the anisotropy of the thermal motion of such water. This anisotropy can be due to the domain shape, as well as the (lack of) dispersion in their orientations. Averaging over measurements that span all orientations is a trick to suppress the latter, thereby untangling it from the influence of the domains' anisotropy on the signal. Here, we consider domains whose anisotropy is modeled as being the result of a Hookean (spring) force, which has the advantage of having a Gaussian diffusion propagator while still retaining the fact of finite spatial range for the diffusing particles. Analytical expressions for the powder-averaged signal under this assumption are given for so-called single and double diffusion encoding schemes, which sensitize the MR signal to the diffusive displacement of particles in, respectively, one or two consecutive time intervals.
△ Less
Submitted 29 December, 2019;
originally announced December 2019.
-
On the reconstruction accuracy of multi-coil MRI with orthogonal projections
Authors:
Anna Breger,
Gabriel Ramos Llorden,
Gonzalo Vegas Sanchez - Ferrero,
W. Scott Hoge,
Martin Ehler,
Carl-Fredrik Westin
Abstract:
MRI signal acquisition with multiple coils in a phased array is nowadays commonplace. The use of multiple receiver coils increases the signal-to-noise ratio (SNR) and enables accelerated parallel imaging methods. Some of these methods, like GRAPPA or SPIRiT, yield individual coil images in the k-space domain which need to be combined to form a final image. Coil combination is often the last step o…
▽ More
MRI signal acquisition with multiple coils in a phased array is nowadays commonplace. The use of multiple receiver coils increases the signal-to-noise ratio (SNR) and enables accelerated parallel imaging methods. Some of these methods, like GRAPPA or SPIRiT, yield individual coil images in the k-space domain which need to be combined to form a final image. Coil combination is often the last step of the image reconstruction, where the root sum of squares (rSOS) is frequently used. This straightforward method works well for coil images with high SNR, but can yield problems in images with artifacts or low SNR in all individual coils. We aim to analyze the final coil combination step in the framework of linear compression, including principal component analysis (PCA). With two data sets, a simulated and an in-vivo, we use random projections as a representation of the whole space of orthogonal projections. This allows us to study the impact of linear compression in the image space with diverse measures of reconstruction accuracy. In particular, the $L_2$ error, variance, SNR, and visual results serve as performance measures to describe the final image quality. We study their relationships and observe that the $L_2$ error and variance strongly correlate, but as expected minimal $L_2$ error does not necessarily correspond to the best visual results. In terms of visual evaluation and SNR, the compression with PCA outperforms all other methods, including rSOS on the uncompressed image space data.
△ Less
Submitted 27 November, 2019; v1 submitted 29 October, 2019;
originally announced October 2019.
-
Dynamics of position-phase probability density in magnetic resonance
Authors:
Cem Yolcu,
Magnus Herberthson,
Carl-Fredrik Westin,
Evren Özarslan
Abstract:
We consider the behaviour of precessional angle (phase) carried by molecules of a diffusing specimen under magnetic fields typical of magnetic resonance experiments. An evolution equation for the ensemble of particles is constructed, which treats the phase as well as the position of the molecules as random variables. This "position-phase (probability) density" (PPD) is shown to encode solutions to…
▽ More
We consider the behaviour of precessional angle (phase) carried by molecules of a diffusing specimen under magnetic fields typical of magnetic resonance experiments. An evolution equation for the ensemble of particles is constructed, which treats the phase as well as the position of the molecules as random variables. This "position-phase (probability) density" (PPD) is shown to encode solutions to a family of Bloch-Torrey equations (BTE) for transverse magnetization density, which is because the PPD is a more fundamental quantity than magnetization density; the latter emerges from the former upon averaging. The present paradigm represents a conceptual advantage, since the PPD is a true probability density subject to Markovian dynamics, rather than an aggregate magnetization density whose evolution is less intuitive. We also work out the analytical solution for suitable special cases.
△ Less
Submitted 7 June, 2019;
originally announced June 2019.
-
Maxwell-compensated design of asymmetric gradient waveforms for tensor-valued diffusion encoding
Authors:
Filip Szczepankiewicz,
Carl-Fredrik Westin,
Markus Nilsson
Abstract:
Purpose: Asymmetric gradient waveforms are attractive for diffusion encoding due to their superior efficiency, however, the asymmetry may cause a residual gradient moment at the end of the encoding. Depending on the experiment setup, this residual moment may cause significant signal bias and image artifacts. The purpose of this study was to develop an asymmetric gradient waveform design for tensor…
▽ More
Purpose: Asymmetric gradient waveforms are attractive for diffusion encoding due to their superior efficiency, however, the asymmetry may cause a residual gradient moment at the end of the encoding. Depending on the experiment setup, this residual moment may cause significant signal bias and image artifacts. The purpose of this study was to develop an asymmetric gradient waveform design for tensor-valued diffusion encoding that is not affected by concomitant gradient. Methods: The Maxwell index was proposed as a scalar invariant that captures the effect of concomitant gradients and was constrained in the numerical optimization to 100 (mT/m)$^2$ms to yield Maxwell-compensated waveforms. The efficacy of this design was tested in an oil phantom, and in a healthy human brain. For reference, waveforms from literature were included in the analysis. Simulations were performed to investigate if the design was valid for a wide range of experiments and if it could predict the signal bias. Results: Maxwell-compensated waveforms showed no signal bias in oil or in the brain. By contrast, several waveforms from literature showed gross signal bias. In the brain, the bias was large enough to markedly affect both signal and parameter maps, and the bias could be accurately predicted by theory. Conclusion: Constraining the Maxwell index in the optimization of asymmetric gradient waveforms yields efficient tensor-valued encoding with concomitant gradients that have a negligible effect on the signal. This waveform design is especially relevant in combination with strong gradients, long encoding times, thick slices, simultaneous multi-slice acquisition and large/oblique FOVs.
△ Less
Submitted 8 March, 2019;
originally announced March 2019.
-
Tensor-valued diffusion MRI in under 3 minutes: An initial survey of microscopic anisotropy and tissue heterogeneity in intracranial tumors
Authors:
Markus Nilsson,
Filip Szczepankiewicz,
Jan Brabec,
Marie Taylor,
Carl-Fredrik Westin,
Alexandra Golby,
Danielle van Westen,
Pia C Sundgren
Abstract:
Purpose: To evaluate the feasibility of a 3-minute b-tensor encoding protocol for diffusion MRI-based assessment of the microscopic anisotropy and tissue heterogeneity in a wide range of intracranial tumors. Methods: B-tensor encoding was performed in 42 patients with intracranial tumors (gliomas, meningiomas, adenomas, metastases). Microscopic anisotropy and tissue heterogeneity were evaluated by…
▽ More
Purpose: To evaluate the feasibility of a 3-minute b-tensor encoding protocol for diffusion MRI-based assessment of the microscopic anisotropy and tissue heterogeneity in a wide range of intracranial tumors. Methods: B-tensor encoding was performed in 42 patients with intracranial tumors (gliomas, meningiomas, adenomas, metastases). Microscopic anisotropy and tissue heterogeneity were evaluated by estimating the anisotropic kurtosis ($MK_A$) and isotropic kurtosis ($MK_I$), respectively. An extensive imaging protocol was compared with a faster 3-minute protocol. Results: The fast imaging protocol yielded parameters with characteristics in terms of bias and precision similar to the full protocol. Glioblastomas had lower microscopic anisotropy than meningiomas $(MK_A = 0.29 \pm 0.06$ versus $0.45\pm0.08, p = 0.003)$. Metastases had higher tissue heterogeneity $(MK_I = 0.57\pm0.07)$ than both the glioblastomas $(0.44\pm0.06, p < 0.001)$ and meningiomas $(0.46\pm0.06, p = 0.03)$. Conclusion: Evaluation of the microscopic anisotropy and tissue heterogeneity in intracranial tumor patients is feasible in clinically relevant times frames.
△ Less
Submitted 26 February, 2019;
originally announced February 2019.
-
Orientationally-averaged diffusion-attenuated magnetic resonance signal for locally-anisotropic diffusion
Authors:
Magnus Herberthson,
Cem Yolcu,
Hans Knutsson,
Carl-Fredrik Westin,
Evren Özarslan
Abstract:
Diffusion-attenuated MR signal for heterogeneous media has been represented as a sum of signals from anisotropic Gaussian sub-domains. Any effect of macroscopic (global or ensemble) anisotropy in the signal can be removed by averaging the signal values obtained by differently oriented experimental schemes. The resulting average signal is identical to what one would get if the micro-domains are iso…
▽ More
Diffusion-attenuated MR signal for heterogeneous media has been represented as a sum of signals from anisotropic Gaussian sub-domains. Any effect of macroscopic (global or ensemble) anisotropy in the signal can be removed by averaging the signal values obtained by differently oriented experimental schemes. The resulting average signal is identical to what one would get if the micro-domains are isotropically (e.g., randomly) distributed, which is the case for "powdered" specimens. We provide exact expressions for the orientationally-averaged signal obtained via general gradient waveforms when the microdomains are characterized by a general diffusion tensor possibly featuring three distinct eigenvalues. Our results are expected to be useful in not only multidimensional diffusion MR but also solid-state NMR spectroscopy due to the mathematical similarities in the two fields.
△ Less
Submitted 27 December, 2018;
originally announced December 2018.
-
Searching for the neurite density with diffusion MRI: challenges for biophysical modeling
Authors:
Björn Lampinen,
Filip Szczepankiewicz,
Mikael Novén,
Danielle van Westen,
Oskar Hansson,
Elisabet Englund,
Johan Mårtensson,
Carl-Fredrik Westin,
Markus Nilsson
Abstract:
In vivo map** of the neurite density with diffusion MRI (dMRI) is a high but challenging aim. First, it is unknown whether all neurites exhibit completely anisotropic ('stick-like') diffusion. Second, the 'density' of tissue components may be confounded by non-diffusion properties such as T2 relaxation. Third, the domain of validity for the estimated parameters to serve as indices of neurite den…
▽ More
In vivo map** of the neurite density with diffusion MRI (dMRI) is a high but challenging aim. First, it is unknown whether all neurites exhibit completely anisotropic ('stick-like') diffusion. Second, the 'density' of tissue components may be confounded by non-diffusion properties such as T2 relaxation. Third, the domain of validity for the estimated parameters to serve as indices of neurite density is incompletely explored. We investigated these challenges by acquiring data with 'b-tensor encoding' and multiple echo times in both healthy brain and white matter lesions. Results showed that microscopic anisotropy from b-tensor data is associated with myelinated axons but not with dendrites. Furthermore, b-tensor and multi-echo data showed that unbiased density estimates in white matter lesions require data-driven estimates of compartment-specific T2 times. Finally, the 'stick' fractions of different biophysical models could generally not serve as neurite density indices across the healthy brain and white matter lesions, where outcomes of comparisons depended on the choice of constraints. In particular, constraining compartment-specific T2 times was ambiguous in the healthy brain and had a large impact on estimated values. In summary, estimating neurite density may require accounting for different diffusion and/or T2 properties between axons and dendrites. Constrained 'index' parameters could be valid within limited domains that should be delineated by future studies.
△ Less
Submitted 24 October, 2018; v1 submitted 7 June, 2018;
originally announced June 2018.
-
NMR signal for particles diffusing under potentials: From path integrals and numerical methods to a new model of diffusion anisotropy
Authors:
Cem Yolcu,
Muhammet Memiç,
Kadir Şimşek,
Carl-Fredrik Westin,
Evren Özarslan
Abstract:
We study the influence of diffusion on NMR experiments when the molecules undergo random motion under the influence of a force field, and place special emphasis on parabolic (Hookean) potentials. To this end, the problem is studied using path integral methods. Explicit relationships are derived for commonly employed gradient waveforms involving pulsed and oscillating gradients. The Bloch-Torrey eq…
▽ More
We study the influence of diffusion on NMR experiments when the molecules undergo random motion under the influence of a force field, and place special emphasis on parabolic (Hookean) potentials. To this end, the problem is studied using path integral methods. Explicit relationships are derived for commonly employed gradient waveforms involving pulsed and oscillating gradients. The Bloch-Torrey equation, describing the temporal evolution of magnetization, is modified by incorporating potentials. A general solution to this equation is obtained for the case of parabolic potential by adopting the multiple correlation function (MCF) formalism, which has been used in the past to quantify the effects of restricted diffusion. Both analytical and MCF results were found to be in agreement with random walk simulations. A multi-dimensional formulation of the problem is introduced that leads to a new characterization of diffusion anisotropy. Unlike for the case of traditional methods that employ a diffusion tensor, anisotropy originates from the tensorial force constant, and bulk diffusivity is retained in the formulation. Our findings suggest that some features of the NMR signal that have traditionally been attributed to restricted diffusion are accommodated by the Hookean model. Under certain conditions, the formalism can be envisioned to provide a viable approximation to the mathematically more challenging restricted diffusion problems.
△ Less
Submitted 21 March, 2016;
originally announced March 2016.
-
The White Matter Query Language: A Novel Approach for Describing Human White Matter Anatomy
Authors:
Demian Wassermann,
Makris Nikos,
Yogesh Rathi,
Shenton Martha,
Ron Kikinis,
Marek Kubicki,
Carl-Fredrik Westin
Abstract:
We have developed a novel method to describe human white matter anatomy using an approach that is both intuitive and simple to use, and which automatically extracts white matter tracts from diffusion MRI volumes. Further, our method simplifies the quantification and statistical analysis of white matter tracts on large diffusion MRI databases. This work reflects the careful syntactical definition o…
▽ More
We have developed a novel method to describe human white matter anatomy using an approach that is both intuitive and simple to use, and which automatically extracts white matter tracts from diffusion MRI volumes. Further, our method simplifies the quantification and statistical analysis of white matter tracts on large diffusion MRI databases. This work reflects the careful syntactical definition of major white matter fiber tracts in the human brain based on a neuroanatomist's expert knowledge. The framework is based on a novel query language with a near-to-English textual syntax. This query language makes it possible to construct a dictionary of anatomical definitions that describe white matter tracts. The definitions include adjacent gray and white matter regions, and rules for spatial relations. This novel method makes it possible to automatically label white matter anatomy across subjects. After describing this method, we provide an example of its implementation where we encode anatomical knowledge in human white matter for 10 association and 15 projection tracts per hemisphere, along with 7 commissural tracts. Importantly, this novel method is comparable in accuracy to manual labeling. Finally, we present results applying this method to create a white matter atlas from 77 healthy subjects, and we use this atlas in a small proof-of-concept study to detect changes in association tracts that characterize schizophrenia.
△ Less
Submitted 23 December, 2015;
originally announced December 2015.