MR sequence design using digital twins of non-idealized hardware
Authors:
Daniel J West,
Felix Glang,
Jonathan Endres,
David Leitão,
Moritz Zaiss,
Joseph V Hajnal,
Shaihan J Malik
Abstract:
MRI systems are traditionally engineered to produce close to idealized performance, enabling a simplified pulse sequence design philosophy. An example of this is control of eddy currents produced by gradient fields; usually these are compensated by pre-emphasizing demanded waveforms. This process typically happens invisibly to the pulse designer, allowing them to assume the achieved gradient wavef…
▽ More
MRI systems are traditionally engineered to produce close to idealized performance, enabling a simplified pulse sequence design philosophy. An example of this is control of eddy currents produced by gradient fields; usually these are compensated by pre-emphasizing demanded waveforms. This process typically happens invisibly to the pulse designer, allowing them to assume the achieved gradient waveform will be as desired. Whilst convenient, this imposes stricter limits on the sequence design than the hardware can handle (for example, pre-emphasis adds an additional overhead to amplifiers). This strategy can be undesirable particularly for lower performance or resource-limited hardware. Instead we explore the use of a 'digital twin' (i.e. an end-to-end model of the scanner system) to optimize control inputs, resulting in sequences that inherently compensate for known imperfections. We explore digital twin optimization specifically for gradient system imperfections as an exemplar. This is first explored in simulations using a simple exponential eddy current model, then experimentally using an empirical gradient impulse response function on a 7T MRI system. When unconstrained, digital twin optimization reproduces classic pre-emphasis. When strict hardware constraints are imposed (simulating lower performance hardware), it identifies novel sequences for scenarios where classic pre-emphasis would be unachievable. Experimentally, the optimization approach was demonstrated to substantially reduce ghosting effects in echo planar images on a 7T system. Digital twin optimization may allow more efficient use of hardware by taking a whole system approach. Ultimately this could enable the use of cheaper hardware without loss of performance.
△ Less
Submitted 26 March, 2024;
originally announced March 2024.
Magnetization Transfer-Mediated MR Fingerprinting
Authors:
Daniel J. West,
Gastao Cruz,
Rui P. A. G. Teixeira,
Torben Schneider,
Jacques-Donald Tournier,
Joseph V. Hajnal,
Claudia Prieto,
Shaihan J. Malik
Abstract:
Purpose: Magnetization transfer (MT) and inhomogeneous MT (ihMT) contrasts are used in MRI to provide information about macromolecular tissue content. In particular, MT is sensitive to macromolecules and ihMT appears to be specific to myelinated tissue. This study proposes a technique to characterize MT and ihMT properties from a single acquisition, producing both semiquantitative contrast ratios,…
▽ More
Purpose: Magnetization transfer (MT) and inhomogeneous MT (ihMT) contrasts are used in MRI to provide information about macromolecular tissue content. In particular, MT is sensitive to macromolecules and ihMT appears to be specific to myelinated tissue. This study proposes a technique to characterize MT and ihMT properties from a single acquisition, producing both semiquantitative contrast ratios, and quantitative parameter maps.
Theory and Methods: Building upon previous work that uses multiband radiofrequency (RF) pulses to efficiently generate ihMT contrast, we propose a cyclic-steady-state approach that cycles between multiband and single-band pulses to boost the achieved contrast. Resultant time-variable signals are reminiscent of a magnetic resonance fingerprinting (MRF) acquisition, except that the signal fluctuations are entirely mediated by magnetization transfer effects. A dictionary-based low-rank inversion method is used to reconstruct the resulting images and to produce both semiquantitative MT ratio (MTR) and ihMT ratio (ihMTR) maps, as well as quantitative parameter estimates corresponding to an ihMT tissue model.
Results: Phantom and in vivo brain data acquired at 1.5T demonstrate the expected contrast trends, with ihMTR maps showing contrast more specific to white matter (WM), as has been reported by others. Quantitative estimation of semisolid fraction and dipolar T1 was also possible and yielded measurements consistent with literature values in the brain.
Conclusions: By cycling between multiband and single-band pulses, an entirely magnetization transfer mediated 'fingerprinting' method was demonstrated. This proof-of-concept approach can be used to generate semiquantitative maps and quantitatively estimate some macromolecular specific tissue parameters.
△ Less
Submitted 23 August, 2021; v1 submitted 6 April, 2021;
originally announced April 2021.