Time-drift Aware RF Optimization with Machine Learning Techniques
Authors:
R. Sharankova,
M. Mwaniki,
K. Seiya,
M. Wesley
Abstract:
The Fermilab Linac delivers 400 MeV H- beam to the rest of the accelerator chain. Providing stable intensity, energy, and emittance is key since it directly affects downstream machines. To operate high current beam, accelerators must minimize uncontrolled particle loss; this can be accomplished by minimizing beam longitudinal emittance via RF parameter optimization. However, RF tuning is required…
▽ More
The Fermilab Linac delivers 400 MeV H- beam to the rest of the accelerator chain. Providing stable intensity, energy, and emittance is key since it directly affects downstream machines. To operate high current beam, accelerators must minimize uncontrolled particle loss; this can be accomplished by minimizing beam longitudinal emittance via RF parameter optimization. However, RF tuning is required daily since the resonance frequency of the accelerating cavities is affected by ambient temperature and humidity variations and thus drifts with time. In addition, the energy and phase space distribution of particles emerging from the ion source are subject to fluctuations. Such drift is not unique to Fermilab, but rather affects most laboratories. We are exploring machine learning (ML) algorithms for automated RF tuning for 2 objectives: optimization of Linac output energy and phase oscillation correction, with an emphasis on time-drift aware modeling that can account for conditions changing over time.
△ Less
Submitted 10 July, 2023;
originally announced July 2023.
-
Beam Loss Monitoring with Fixed and Translating Scintillation Detectors Along the Fermilab Drift-tube Linac
Authors:
J. Stanton,
R. Sharankova,
K. Seiya,
M. Wesley
Abstract:
The Fermilab Linac is a roughly 145 meter linear accelerator that accelerates H- beam from 750 keV to 400 MeV and provides beam for the Booster and the rest of the accelerator chain. The first section of the Linac is a Drift-Tube Linac (DTL), which in its current state, suffers from a lack of instrumentation along its length. As a result, operational staff do not have access to the diagnostic info…
▽ More
The Fermilab Linac is a roughly 145 meter linear accelerator that accelerates H- beam from 750 keV to 400 MeV and provides beam for the Booster and the rest of the accelerator chain. The first section of the Linac is a Drift-Tube Linac (DTL), which in its current state, suffers from a lack of instrumentation along its length. As a result, operational staff do not have access to the diagnostic information needed to tune the critical components of this accelerator, such as the quadrupole magnets within the drift tubes. This work presents an effort to utilize both fixed and translating scintillation detectors to investigate beam loss along the first two cavities of the DTL.
△ Less
Submitted 23 May, 2023;
originally announced May 2023.
-
Diagnostics for Linac Optimization With Machine Learning
Authors:
R. Sharankova,
M. Mwaniki,
K. Seiya,
M. Wesley
Abstract:
The Fermilab Linac delivers 400 MeV H- beam to the rest of the accelerator chain. Providing stable intensity, energy, and emittance is key since it directly affects downstream machines. To counter fluctuations of Linac output due to various effects to be described below we are working on implementing dynamic longitudinal parameter optimization based on Machine Learning (ML). As inputs for the ML m…
▽ More
The Fermilab Linac delivers 400 MeV H- beam to the rest of the accelerator chain. Providing stable intensity, energy, and emittance is key since it directly affects downstream machines. To counter fluctuations of Linac output due to various effects to be described below we are working on implementing dynamic longitudinal parameter optimization based on Machine Learning (ML). As inputs for the ML model, signals from beam diagnostics have to be well understood and reliable. In this paper we discuss the status and plans for ML-based optimization as well as preliminary results of diagnostics studies.
△ Less
Submitted 6 September, 2022;
originally announced September 2022.
-
Operation of the H- Linac at FNAL
Authors:
K. Seiya,
T. Butler,
D. Jones,
V. Kapin,
K. Hartman,
S. Moua,
J. -F. Ostiguy,
R. Ridgway,
R. Sharankova,
B. Stanzil,
C. Y. Tan,
J. Walters,
M. Wesley,
M. Mwaniki
Abstract:
The Fermi National Accelerator Laboratory (FNAL) Linac has been in operation for 52 years. In approximately four years, it will be replaced by a new 800 MeV superconducting machine, the PIP-II SRF Linac. In the current configuration, the Linac delivers H- ions at 400 MeV and injects protons by charge exchange into the Booster synchrotron. Despite its age, the Linac is the most stable accelerator i…
▽ More
The Fermi National Accelerator Laboratory (FNAL) Linac has been in operation for 52 years. In approximately four years, it will be replaced by a new 800 MeV superconducting machine, the PIP-II SRF Linac. In the current configuration, the Linac delivers H- ions at 400 MeV and injects protons by charge exchange into the Booster synchrotron. Despite its age, the Linac is the most stable accelerator in the FNAL complex, reliably sending 22 mA in daily operations. We will discuss the status of the operation, beam studies, and plans.
△ Less
Submitted 6 September, 2022;
originally announced September 2022.