-
Emittance preservation in a plasma-wakefield accelerator
Authors:
C. A. Lindstrøm,
J. Beinortaitė,
J. Björklund Svensson,
L. Boulton,
J. Chappell,
S. Diederichs,
B. Foster,
J. M. Garland,
P. González Caminal,
G. Loisch,
F. Peña,
S. Schröder,
M. Thévenet,
S. Wesch,
M. Wing,
J. C. Wood,
R. D'Arcy,
J. Osterhoff
Abstract:
Radio-frequency particle accelerators are engines of discovery, powering high-energy physics and photon science, but are also large and expensive due to their limited accelerating fields. Plasma-wakefield accelerators (PWFAs) provide orders-of-magnitude stronger fields in the charge-density wave behind a particle bunch travelling in a plasma, promising particle accelerators of greatly reduced size…
▽ More
Radio-frequency particle accelerators are engines of discovery, powering high-energy physics and photon science, but are also large and expensive due to their limited accelerating fields. Plasma-wakefield accelerators (PWFAs) provide orders-of-magnitude stronger fields in the charge-density wave behind a particle bunch travelling in a plasma, promising particle accelerators of greatly reduced size and cost. However, PWFAs can easily degrade the beam quality of the bunches they accelerate. Emittance, which determines how tightly beams can be focused, is a critical beam quality in for instance colliders and free-electron lasers, but is particularly prone to degradation. We demonstrate, for the first time, emittance preservation in a high-gradient and high-efficiency PWFA while simultaneously preserving charge and energy spread. This establishes that PWFAs can accelerate without degradation$\unicode{x2014}$essential for energy boosters in photon science and multistage facilities for compact high-energy particle colliders.
△ Less
Submitted 26 March, 2024;
originally announced March 2024.
-
Energy Depletion and Re-Acceleration of Driver Electrons in a Plasma-Wakefield Accelerator
Authors:
F. Peña,
C. A. Lindstrøm,
J. Beinortaitė,
J. Björklund Svensson,
L. Boulton,
S. Diederichs,
B. Foster,
J. M. Garland,
P. González Caminal,
G. Loisch,
S. Schröder,
M. Thévenet,
S. Wesch,
J. C. Wood,
J. Osterhoff,
R. D'Arcy
Abstract:
For plasma-wakefield accelerators to fulfil their potential for cost effectiveness, it is essential that their energy-transfer efficiency be maximized. A key aspect of this efficiency is the near-complete transfer of energy, or depletion, from the driver electrons to the plasma wake. Achieving full depletion is limited by the process of re-acceleration, which occurs when the driver electrons decel…
▽ More
For plasma-wakefield accelerators to fulfil their potential for cost effectiveness, it is essential that their energy-transfer efficiency be maximized. A key aspect of this efficiency is the near-complete transfer of energy, or depletion, from the driver electrons to the plasma wake. Achieving full depletion is limited by the process of re-acceleration, which occurs when the driver electrons decelerate to non-relativistic energies, slip** backwards into the accelerating phase of the wakefield and being subsequently re-accelerated. Such re-acceleration is observed here for the first time. At this re-acceleration limit, we measure a beam driver depositing (56 $\pm$ 5)% of its energy into a 195-mm-long plasma. Combining this driver-to-plasma efficiency with previously measured plasma-to-beam and expected wall-plug-to-driver efficiencies, our result shows that plasma-wakefield accelerators can in principle reach or even exceed the energy-transfer efficiency of conventional accelerators.
△ Less
Submitted 25 September, 2023; v1 submitted 16 May, 2023;
originally announced May 2023.
-
Longitudinally resolved measurement of energy-transfer efficiency in a plasma-wakefield accelerator
Authors:
L. Boulton,
C. A. Lindstrøm,
J. Beinortaite,
J. Björklund Svensson,
J. M. Garland,
P. González Caminal,
B. Hidding,
G. Loisch,
F. Peña,
K. Põder,
S. Schröder,
S. Wesch,
J. C. Wood,
J. Osterhoff,
R. D'Arcy
Abstract:
Energy-transfer efficiency is an important quantity in plasma-wakefield acceleration, especially for applications that demand high average power. Conventionally, the efficiency is measured using an electron spectrometer; an invasive method that provides an energy-transfer efficiency averaged over the full length of the plasma accelerator. Here, we experimentally demonstrate a novel diagnostic util…
▽ More
Energy-transfer efficiency is an important quantity in plasma-wakefield acceleration, especially for applications that demand high average power. Conventionally, the efficiency is measured using an electron spectrometer; an invasive method that provides an energy-transfer efficiency averaged over the full length of the plasma accelerator. Here, we experimentally demonstrate a novel diagnostic utilizing the excess light emitted by the plasma after a beam-plasma interaction, which yields noninvasive, longitudinally resolved measurements of the local energy-transfer efficiency from the wake to the accelerated bunch; here, as high as (58 $\pm$ 3)%. This method is suitable for online optimization of individual stages in a future multistage plasma accelerator, and enables experimental studies of the relation between efficiency and transverse instability in the acceleration process.
△ Less
Submitted 14 September, 2022;
originally announced September 2022.
-
Recovery time of a plasma-wakefield accelerator
Authors:
R. D'Arcy,
J. Chappell,
J. Beinortaite,
S. Diederichs,
G. Boyle,
B. Foster,
M. J. Garland,
P. Gonzalez Caminal,
C. A. Lindstrøm,
G. Loisch,
S. Schreiber,
S. Schröder,
R. J. Shalloo,
M. Thévenet,
S. Wesch,
M. Wing,
J. Osterhoff
Abstract:
The interaction of intense particle bunches with plasma can give rise to plasma wakes capable of sustaining gigavolt-per-metre electric fields, which are orders of magnitude higher than provided by state-of-the-art radio-frequency technology. Plasma wakefields can, therefore, strongly accelerate charged particles and offer the opportunity to reach higher particle energies with smaller and hence mo…
▽ More
The interaction of intense particle bunches with plasma can give rise to plasma wakes capable of sustaining gigavolt-per-metre electric fields, which are orders of magnitude higher than provided by state-of-the-art radio-frequency technology. Plasma wakefields can, therefore, strongly accelerate charged particles and offer the opportunity to reach higher particle energies with smaller and hence more widely available accelerator facilities. However, the luminosity and brilliance demands of high-energy physics and photon science require particle bunches to be accelerated at repetition rates of thousands or even millions per second, which are orders of magnitude higher than demonstrated with plasma-wakefield technology. Here we investigate the upper limit on repetition rates of beam-driven plasma accelerators by measuring the time it takes for the plasma to recover to its initial state after perturbation by a wakefield. The many-nanosecond-level recovery time measured establishes the in-principle attainability of megahertz rates of acceleration in plasmas. The experimental signatures of the perturbation are well described by simulations of a temporally evolving parabolic ion channel, transferring energy from the collapsing wake to the surrounding media. This result establishes that plasma-wakefield modules could be developed as feasible high-repetition-rate energy boosters at current and future particle-physics and photon-science facilities.
△ Less
Submitted 3 March, 2022;
originally announced March 2022.
-
Progress of the FLASHForward X-2 high-beam-quality, high-efficiency plasma-accelerator experiment
Authors:
C. A. Lindstrøm,
J. Beinortaite,
J. Björklund Svensson,
L. Boulton,
J. Chappell,
J. M. Garland,
P. Gonzalez,
G. Loisch,
F. Peña,
L. Schaper,
B. Schmidt,
S. Schröder,
S. Wesch,
J. Wood,
J. Osterhoff,
R. D'Arcy
Abstract:
FLASHForward is an experimental facility at DESY dedicated to beam-driven plasma-accelerator research. The X-2 experiment aims to demonstrate acceleration with simultaneous beam-quality preservation and high energy efficiency in a compact plasma stage. We report on the completed commissioning, first experimental results, ongoing research topics, as well as plans for future upgrades.
FLASHForward is an experimental facility at DESY dedicated to beam-driven plasma-accelerator research. The X-2 experiment aims to demonstrate acceleration with simultaneous beam-quality preservation and high energy efficiency in a compact plasma stage. We report on the completed commissioning, first experimental results, ongoing research topics, as well as plans for future upgrades.
△ Less
Submitted 16 November, 2021;
originally announced November 2021.
-
Controlled density-downramp injection in a beam-driven plasma wakefield accelerator
Authors:
Alexander Knetsch,
Bridget Sheeran,
Lewis Boulton,
Pardis Niknejadi,
Kristjan Põder,
Lucas Schaper,
Ming Zeng,
Simon Bohlen,
Gregory Boyle,
Theresa Brümmer,
James Chappell,
Richard D'Arcy,
Severin Diederichs,
Brian Foster,
Matthew James Garland,
Pau Gonzalez Caminal,
Bernhard Hidding,
Vladislav Libov,
Carl Andreas Lindstrøm,
Alberto Martinez de la Ossa,
Martin Meisel,
Trupen Parikh,
Bernhard Schmidt,
Sarah Schröder,
Gabriele Tauscher
, et al. (4 additional authors not shown)
Abstract:
This paper describes the utilization of beam-driven plasma wakefield acceleration to implement a high-quality plasma cathode via density-downramp injection in a short injector stage at the FLASHForward facility at DESY. Electron beams with charge of up to 105 pC and energy spread of a few percent were accelerated by a tunable effective accelerating field of up to 2.7 GV/m. The plasma cathode was o…
▽ More
This paper describes the utilization of beam-driven plasma wakefield acceleration to implement a high-quality plasma cathode via density-downramp injection in a short injector stage at the FLASHForward facility at DESY. Electron beams with charge of up to 105 pC and energy spread of a few percent were accelerated by a tunable effective accelerating field of up to 2.7 GV/m. The plasma cathode was operated drift-free with very high injection efficiency. Sources of jitter, the emittance and divergence of the resulting beam were investigated and modeled, as were strategies for performance improvements that would further increase the wide-ranging applications for a plasma cathode with the demonstrated operational stability
△ Less
Submitted 10 August, 2020; v1 submitted 24 July, 2020;
originally announced July 2020.
-
Tunable and precise two-bunch generation at FLASHForward
Authors:
S. Schröder,
K. Ludwig,
A. Aschikhin,
R. D'Arcy,
M. Dinter,
P. Gonzalez,
S. Karstensen,
A. Knetsch,
V. Libov,
C. A. Lindstrøm,
F. Marutzky,
P. Niknejadi,
A. Rahali,
L. Schaper,
A. Schleiermacher,
B. Schmidt,
S. Thiele,
A. de Zubiaurre Wagner,
S. Wesch,
J. Osterhoff
Abstract:
Beam-driven plasma-wakefield acceleration based on external injection has the potential to significantly reduce the size of future accelerators. Stability and quality of the acceleration process substantially depends on the incoming bunch parameters. Precise control of the current profile is essential for optimising energy-transfer efficiency and preserving energy spread. At the FLASHForward facil…
▽ More
Beam-driven plasma-wakefield acceleration based on external injection has the potential to significantly reduce the size of future accelerators. Stability and quality of the acceleration process substantially depends on the incoming bunch parameters. Precise control of the current profile is essential for optimising energy-transfer efficiency and preserving energy spread. At the FLASHForward facility, driver--witness bunch pairs of adjustable bunch length and separation are generated by a set of collimators in a dispersive section, which enables fs-level control of the longitudinal bunch profile. The design of the collimator apparatus and its commissioning is presented.
△ Less
Submitted 25 May, 2020;
originally announced May 2020.
-
Matching small $β$ functions using centroid jitter and two beam position monitors
Authors:
C. A. Lindstrøm,
R. D'Arcy,
M. J. Garland,
P. Gonzalez,
B. Schmidt,
S. Schröder,
S. Wesch,
J. Osterhoff
Abstract:
Matching to small beta functions is required to preserve emittance in plasma accelerators. The plasma wake provides strong focusing fields, which typically require beta functions on the mm-scale, comparable to those found in the final focusing of a linear collider. Such beams can be time consuming to experimentally produce and diagnose. We present a simple, fast, and noninvasive method to measure…
▽ More
Matching to small beta functions is required to preserve emittance in plasma accelerators. The plasma wake provides strong focusing fields, which typically require beta functions on the mm-scale, comparable to those found in the final focusing of a linear collider. Such beams can be time consuming to experimentally produce and diagnose. We present a simple, fast, and noninvasive method to measure Twiss parameters in a linac using two beam position monitors only, relying on the similarity of the beam phase space and the jitter phase space. By benchmarking against conventional quadrupole scans, the viability of this technique was experimentally demonstrated at the FLASHForward plasma-accelerator facility.
△ Less
Submitted 29 May, 2020; v1 submitted 14 February, 2020;
originally announced February 2020.
-
FLASHForward: Plasma-wakefield accelerator science for high-average-power applications
Authors:
R. D'Arcy,
A. Aschikhin,
S. Bohlen,
G. Boyle,
T. Brümmer,
J. Chappell,
S. Diederichs,
B. Foster,
M. J. Garland,
L. Goldberg,
P. Gonzalez,
S. Karstensen,
A. Knetsch,
P. Kuang,
V. Libov,
K. Ludwig,
A. Martinez de la Ossa,
F. Marutzky,
M. Meisel,
T. J. Mehrling,
P. Niknejadi,
K. Poder,
P. Pourmoussavi,
M. Quast,
J. -H. Röckemann
, et al. (11 additional authors not shown)
Abstract:
The FLASHForward experimental facility is a high-performance test-bed for precision plasma-wakefield research, aiming to accelerate high-quality electron beams to GeV-levels in a few centimetres of ionised gas. The plasma is created by ionising gas in a gas cell either by a high-voltage discharge or a high-intensity laser pulse. The electrons to be accelerated will either be injected internally fr…
▽ More
The FLASHForward experimental facility is a high-performance test-bed for precision plasma-wakefield research, aiming to accelerate high-quality electron beams to GeV-levels in a few centimetres of ionised gas. The plasma is created by ionising gas in a gas cell either by a high-voltage discharge or a high-intensity laser pulse. The electrons to be accelerated will either be injected internally from the plasma background or externally from the FLASH superconducting RF front end. In both cases the wakefield will be driven by electron beams provided by the FLASH gun and linac modules operating with a 10 Hz macro-pulse structure, generating 1.25 GeV, 1 nC electron bunches at up to 3 MHz micro-pulse repetition rates. At full capacity, this FLASH bunch-train structure corresponds to 30 kW of average power, orders of magnitude higher than drivers available to other state-of-the-art LWFA and PWFA experiments. This high-power functionality means FLASHForward is the only plasma-wakefield facility in the world with the immediate capability to develop, explore, and benchmark high-average-power plasma-wakefield research essential for next-generation facilities. The operational parameters and technical highlights of the experiment are discussed, as well as the scientific goals and high-average-power outlook.
△ Less
Submitted 9 May, 2019;
originally announced May 2019.
-
A tunable plasma-based energy dechirper
Authors:
R. D'Arcy,
S. Wesch,
A. Aschikhin,
S. Bohlen,
C. Behrens,
M. J. Garland,
L. Goldberg,
P. Gonzalez,
A. Knetsch,
V. Libov,
A. Martinez de la Ossa,
M. Meisel,
T. J. Mehrling,
P. Niknejadi,
K. Poder,
J. -H. Roeckemann,
L. Schaper,
B. Schmidt,
S. Schroeder,
C. Palmer,
J. -P. Schwinkendorf,
B. Sheeran,
M. J. V. Streeter,
G. Tauscher,
V. Wacker
, et al. (1 additional authors not shown)
Abstract:
A tunable plasma-based energy dechirper has been developed at FLASHForward to remove the correlated energy spread of a 681~MeV electron bunch. Through the interaction of the bunch with wakefields excited in plasma the projected energy spread was reduced from a FWHM of 1.31$\%$ to 0.33$\%$ without reducing the stability of the incoming beam. The experimental results for variable plasma density are…
▽ More
A tunable plasma-based energy dechirper has been developed at FLASHForward to remove the correlated energy spread of a 681~MeV electron bunch. Through the interaction of the bunch with wakefields excited in plasma the projected energy spread was reduced from a FWHM of 1.31$\%$ to 0.33$\%$ without reducing the stability of the incoming beam. The experimental results for variable plasma density are in good agreement with analytic predictions and three-dimensional simulations. The proof-of-principle dechir** strength of $1.8$~GeV/mm/m significantly exceeds those demonstrated for competing state-of-the-art techniques and may be key to future plasma wakefield-based free-electron lasers and high energy physics facilities, where large intrinsic chirps need to be removed.
△ Less
Submitted 4 January, 2019; v1 submitted 15 October, 2018;
originally announced October 2018.
-
Direct Measurement of Focusing Fields in Active Plasma Lenses
Authors:
J. -H. Röckemann,
L. Schaper,
S. K. Barber,
N. A. Bobrova,
G. Boyle,
S. Bulanov,
N. Delbos,
K. Floettmann,
G. Kube,
W. Lauth,
W. P. Leemans,
V. Libov,
A. Maier,
M. Meisel,
P. Messner,
P. V. Sasorov,
C. B. Schroeder,
J. van Tilborg,
S. Wesch,
J. Osterhoff
Abstract:
Active plasma lenses have the potential to enable broad-ranging applications of plasma-based accelerators owing to their compact design and radially symmetric kT/m-level focusing fields, facilitating beam-quality preservation and compact beam transport. We report on the direct measurement of magnetic field gradients in active plasma lenses and demonstrate their impact on the emittance of a charged…
▽ More
Active plasma lenses have the potential to enable broad-ranging applications of plasma-based accelerators owing to their compact design and radially symmetric kT/m-level focusing fields, facilitating beam-quality preservation and compact beam transport. We report on the direct measurement of magnetic field gradients in active plasma lenses and demonstrate their impact on the emittance of a charged particle beam. This is made possible by the use of a well-characterized electron beam with 1.4 mm mrad normalized emittance from a conventional accelerator. Field gradients of up to 823 T/m are investigated. The observed emittance evolution is supported by numerical simulations, which suggest the potential for conservation of the core beam emittance in such a plasma lens setup.
△ Less
Submitted 21 September, 2018; v1 submitted 18 March, 2018;
originally announced March 2018.
-
Longitudinal Bunch Diagnostics using Coherent Transition Radiation Spectroscopy
Authors:
Bernhard Schmidt,
Stephan Wesch,
Toke Kövener,
Christopher Behrens,
Eugen Hass,
Sara Casalbuoni,
Peter Schmüser
Abstract:
The generation and properties of transition radiation (TR) are thoroughly treated. The spectral energy density, as described by the Ginzburg-Frank formula, is computed analytically, and the modifications caused by the finite size of the TR screen and by near-field diffraction effects are carefully analyzed. The principles of electron bunch shape reconstruction using coherent transition radiation a…
▽ More
The generation and properties of transition radiation (TR) are thoroughly treated. The spectral energy density, as described by the Ginzburg-Frank formula, is computed analytically, and the modifications caused by the finite size of the TR screen and by near-field diffraction effects are carefully analyzed. The principles of electron bunch shape reconstruction using coherent transition radiation are outlined. Spectroscopic measure- ments yield only the magnitude of the longitudinal form factor but not its phase. Two phase retrieval methods are investigated and illustrated with model calculations: analytic phase computation by means of the Kramers- Kronig dispersion relation, and iterative phase retrieval. Particular attention is paid to the ambiguities which are unavoidable in the reconstruction of longitudinal charge density profiles from spectroscopic data. The origin of these ambiguities has been identified and a thorough mathematical analysis is presented. The experimental part of the paper comprises a description of our multichannel infrared and THz spectrometer and a selection of measurements at FLASH, comparing the bunch profiles derived from spectroscopic data with those determined with a transversely deflecting microwave structure. A rigorous derivation of the Kramers-Kronig phase formula is presented in Appendix A. Numerous analytic model calculations can be found in Appendix B. The differences between normal and truncated Gaussians are discussed in Appendix C. Finally, Appendix D contains a short description of the propagation of an electromagnetic wave front by two-dimensional fast Fourier transformation. This is the basis of a powerful numerical Mathematica code THzTransport, which permits the propagation of electromagnetic wave fronts through a beam line consisting of drift spaces, lenses, mirrors and apertures.
△ Less
Submitted 1 March, 2018;
originally announced March 2018.
-
Electron beam profile imaging in the presence of coherent optical radiation effects
Authors:
Christopher Behrens,
Christopher Gerth,
Gero Kube,
Bernhard Schmidt,
Stephan Wesch,
Minjie Yan
Abstract:
High-brightness electron beams with low energy spread at existing and future x-ray free-electron lasers are affected by various collective beam self-interactions and microbunching instabilities. The corresponding coherent optical radiation effects, e.g., coherent optical transition radiation, render electron beam profile imaging impossible and become a serious issue for all kinds of electron beam…
▽ More
High-brightness electron beams with low energy spread at existing and future x-ray free-electron lasers are affected by various collective beam self-interactions and microbunching instabilities. The corresponding coherent optical radiation effects, e.g., coherent optical transition radiation, render electron beam profile imaging impossible and become a serious issue for all kinds of electron beam diagnostics using imaging screens. Furthermore, coherent optical radiation effects can also be related to intrinsically ultrashort electron bunches or the existence of ultrashort spikes inside the electron bunches. In this paper, we discuss methods to suppress coherent optical radiation effects both by electron beam profile imaging in dispersive beamlines and by using scintillation imaging screens in combination with separation techniques. The suppression of coherent optical emission in dispersive beamlines is shown by analytical calculations, numerical simulations, and measurements. Transverse and longitudinal electron beam profile measurements in the presence of coherent optical radiation effects in non-dispersive beamlines are demonstrated by applying a temporal separation technique.
△ Less
Submitted 14 June, 2012; v1 submitted 6 March, 2012;
originally announced March 2012.
-
Constraints on photon pulse duration from longitudinal electron beam diagnostics at a soft X-ray free-electron laser
Authors:
C. Behrens,
N. Gerasimova,
Ch. Gerth,
B. Schmidt,
E. A. Schneidmiller,
S. Serkez,
S. Wesch,
M. V. Yurkov
Abstract:
The successful operation of X-ray free-electron lasers (FELs), like the Linac Coherent Light Source or the Free-Electron Laser in Hamburg (FLASH), makes unprecedented research on matter at atomic length and ultrafast time scales possible. However, in order to take advantage of these unique light sources and to meet the strict requirements of many experiments in photon science, FEL photon pulse dur…
▽ More
The successful operation of X-ray free-electron lasers (FELs), like the Linac Coherent Light Source or the Free-Electron Laser in Hamburg (FLASH), makes unprecedented research on matter at atomic length and ultrafast time scales possible. However, in order to take advantage of these unique light sources and to meet the strict requirements of many experiments in photon science, FEL photon pulse durations need to be known and tunable. This can be achieved by controlling the FEL driving electron beams, and high-resolution longitudinal electron beam diagnostics can be utilized to provide constraints on the expected FEL photon pulse durations. In this paper, we present comparative measurements of soft X-ray pulse durations and electron bunch lengths at FLASH. The soft X-ray pulse durations were measured by FEL radiation pulse energy statistics and compared to electron bunch lengths determined by frequency-domain spectroscopy of coherent transition radiation in the terahertz range and time-domain longitudinal phase space measurements. The experimental results, theoretical considerations, and simulations show that high-resolution longitudinal electron beam diagnostics provide reasonable constraints on the expected FEL photon pulse durations. In addition, we demonstrated the generation of soft X-ray pulses with durations below 50 fs (FWHM) after the implementation of the new uniform electron bunch compression scheme used at FLASH.
△ Less
Submitted 6 March, 2012; v1 submitted 20 January, 2012;
originally announced January 2012.
-
A Multi-Channel THz and Infrared Spectrometer for Femtosecond Electron Bunch Diagnostics by Single-Shot Spectroscopy of Coherent Radiation
Authors:
S. Wesch,
B. Schmidt,
C. Behrens,
H. Delsim-Hashemi,
P. Schmüser
Abstract:
The high peak current required in free-electron lasers (FELs) is realized by longitudinal compression of the electron bunches to sub-picosecond length. In this paper, a frequency-domain diagnostic method is described that is capable of resolving structures in the femtosecond regime. A novel in-vacuum spectrometer has been developed for spectroscopy of coherent radiation in the THz and infrared ran…
▽ More
The high peak current required in free-electron lasers (FELs) is realized by longitudinal compression of the electron bunches to sub-picosecond length. In this paper, a frequency-domain diagnostic method is described that is capable of resolving structures in the femtosecond regime. A novel in-vacuum spectrometer has been developed for spectroscopy of coherent radiation in the THz and infrared range. The spectrometer is equipped with five consecutive dispersion gratings and 120 parallel readout channels; it can be operated either in short wavelength mode (5 - 44 um) or in long wavelength mode (45 - 430 um). Fast parallel readout permits the spectroscopy of coherent radiation from single electron bunches. Test measurements at the soft X-ray free-electron laser FLASH, using coherent transition radiation, demonstrate excellent performance of the spectrometer. The high sensitivity down to a few micrometers allows study of short bunch features caused for example by microbunching effects in magnetic chicanes. The device is planned for use as an online bunch profile monitor during regular FEL operation.
△ Less
Submitted 29 January, 2012; v1 submitted 2 September, 2011;
originally announced September 2011.