-
Heavy Positive Ion Groups in Titan's Ionosphere from Cassini Plasma Spectrometer IBS Observations
Authors:
Richard P. Haythornthwaite,
Andrew J. Coates,
Geraint H. Jones,
Anne Wellbrock,
J. Hunter Waite,
Veronique Vuitton,
Panayotis Lavvas
Abstract:
Titan's ionosphere contains a plethora of hydrocarbons and nitrile cations and anions as measured by the Ion Neutral Mass Spectrometer and Cassini Plasma Spectrometer (CAPS) onboard the Cassini spacecraft. Data from the CAPS Ion Beam Spectrometer (IBS) sensor have been examined for five close encounters of Titan during 2009. The high relative velocity of Cassini with respect to the cold ions in Ti…
▽ More
Titan's ionosphere contains a plethora of hydrocarbons and nitrile cations and anions as measured by the Ion Neutral Mass Spectrometer and Cassini Plasma Spectrometer (CAPS) onboard the Cassini spacecraft. Data from the CAPS Ion Beam Spectrometer (IBS) sensor have been examined for five close encounters of Titan during 2009. The high relative velocity of Cassini with respect to the cold ions in Titan's ionosphere allows CAPS IBS to function as a mass spectrometer. Positive ion masses between 170 and 310 u/q are examined with ion mass groups identified between 170 and 275 u/q containing between 14 and 21 heavy (carbon/nitrogen/oxygen) atoms. These groups are the heaviest positive ion groups reported so far from the available in situ ion data at Titan. The ion group peaks are found to be consistent with masses associated with Polycyclic Aromatic Compounds (PAC), including Polycyclic Aromatic Hydrocarbon (PAH) and nitrogen-bearing polycyclic aromatic molecular ions. The ion group peak identifications are compared with previously proposed neutral PAHs and are found to be at similar masses, supporting a PAH interpretation. The spacing between the ion group peaks is also investigated, finding a spacing of 12 or 13 u/q indicating the addition of C or CH. Lastly, the occurrence of several ion groups is seen to vary across the five flybys studied, possibly relating to the varying solar radiation conditions observed across the flybys. These findings further the understanding between the low mass ions and the high mass negative ions, as well as with aerosol formation in Titan's atmosphere.
△ Less
Submitted 15 December, 2020; v1 submitted 18 September, 2020;
originally announced September 2020.
-
Spatial variations of low mass negative ions in Titan's upper atmosphere
Authors:
Teodora Mihailescu,
Ravindra Desai,
Oleg Shebanits,
Richard Haythornthwaite,
Anne Wellbrock,
Andrew Coates,
Jonathan Eastwood,
J. Hunter Waite
Abstract:
Observations with Cassini's Electron Spectrometer discovered negative ions in Titan's ionosphere, at altitudes between 1400 and 950 km. Within the broad mass distribution extending up to several thousand amu, two distinct peaks were identified at 25.8-26.0 and 49.0-50.1 amu/q, corresponding to the carbon chain anions $CN^-$ and/or $C_2H^-$ for the first peak and $C_3N^-$ and/or $C_4H^-$ for the se…
▽ More
Observations with Cassini's Electron Spectrometer discovered negative ions in Titan's ionosphere, at altitudes between 1400 and 950 km. Within the broad mass distribution extending up to several thousand amu, two distinct peaks were identified at 25.8-26.0 and 49.0-50.1 amu/q, corresponding to the carbon chain anions $CN^-$ and/or $C_2H^-$ for the first peak and $C_3N^-$ and/or $C_4H^-$ for the second peak. In this study we present the spatial distribution of these low mass negative ions from 28 Titan flybys with favourable observations between 26 October 2004 and 22 May 2012. We report a trend of lower densities on the night side and increased densities up to twice as high on the day side at small solar zenith angles. To further understand this trend, we compare the negative ion densities to the total electron density measured by Cassini's Langmuir Probe. We find the low mass negative ion density and the electron density to be proportional to each other on the dayside, but independent of each other on the night side. This indicates photochemical processes and is in agreement with the primary production route for the low mass negative ions being initiated by dissociative reactions with suprathermal electron populations produced by photoionisation. We also find the ratio of $CN^-/C_2H^-$ to $C_3N^-/C_4H^-$ highly constrained on the day-side, in agreement with this production channel, but notably displays large variations on the nightside.
△ Less
Submitted 17 August, 2020;
originally announced August 2020.
-
Nitrogen-containing Anions and Tholin Growth in Titan's Ionosphere: Implications for Cassini CAPS-ELS Observations
Authors:
David Dubois,
Nathalie Carrasco,
Jérémy Bourgalais,
Ludovic Vettier,
Ravindra T. Desai,
Anne Wellbrock,
Andrew J. Coates
Abstract:
The Cassini Plasma Spectrometer (CAPS) Electron Spectrometer (ELS) instrument onboard Cassini revealed an unexpected abundance of negative ions above 950 km in Titan's ionosphere. \textit{In situ} measurements indicated the presence of negatively charged particles with mass-over-charge ratios up to 13,800 \textit{u/q}. At present, only a handful of anions have been characterized by photochemical m…
▽ More
The Cassini Plasma Spectrometer (CAPS) Electron Spectrometer (ELS) instrument onboard Cassini revealed an unexpected abundance of negative ions above 950 km in Titan's ionosphere. \textit{In situ} measurements indicated the presence of negatively charged particles with mass-over-charge ratios up to 13,800 \textit{u/q}. At present, only a handful of anions have been characterized by photochemical models, consisting mainly of C$_n$H$^-$ carbon chain and C$_{n-1}$N$^-$ cyano compounds ($n=2-6$); their formation occurring essentially through proton abstraction from their parent neutral molecules. However, numerous other species have yet to be detected and identified. Considering the efficient anion growth leading to compounds of thousands of \textit{u/q}, it is necessary to better characterize the first light species. Here, we present new negative ion measurements with masses up to 200 \textit{u/q} obtained in an \ce{N2}:\ce{CH4} dusty plasma discharge reproducing analogous conditions to Titan's ionosphere. We perform a comparison with high altitude CAPS-ELS measurements near the top of Titan's ionosphere from the T18 encounter. The main observed peaks are in agreement with the observations. However, a number of other species (\textit{e.g.} \ce{CNN-}, \ce{CHNN-}) previously not considered suggests an abundance of N-bearing compounds, containing two or three nitrogen atoms, consistent with certain adjacent doubly-bonded nitrogen atoms found in tholins. These results suggest that an N-rich incorporation into tholins may follow mechanisms including anion chemistry, further highlighting the important role of negative ions in Titan's aerosol growth.
△ Less
Submitted 14 February, 2019;
originally announced February 2019.
-
Carbon chain anions and the growth of complex organic molecules in Titan's ionosphere
Authors:
R. T. Desai,
A. J. Coates,
A. Wellbrock,
V. Vuitton,
F. J. Crary,
D. González-Caniulef,
O. Shebanits,
G. H. Jones,
G. R. Lewis,
J. H. Waite,
S. A. Taylor,
D. O. Kataria,
J. -E. Wahlund,
N. J. T. Edberg,
E. C. Sittler
Abstract:
Cassini discovered a plethora of neutral and ionised molecules in Titan's ionosphere including, surprisingly, anions and negatively charged molecules extending up to 13,800 u/q. In this letter we forward model the Cassini electron spectrometer response function to this unexpected ionospheric component to achieve an increased mass resolving capability for negatively charged species observed at Tita…
▽ More
Cassini discovered a plethora of neutral and ionised molecules in Titan's ionosphere including, surprisingly, anions and negatively charged molecules extending up to 13,800 u/q. In this letter we forward model the Cassini electron spectrometer response function to this unexpected ionospheric component to achieve an increased mass resolving capability for negatively charged species observed at Titan altitudes of 950-1300 km. We report on detections consistently centered between 25.8-26.0 u/q and between 49.0-50.1 u/q which are identified as belonging to the carbon chain anions, CN$^-$/C$_3$N$^-$ and/or C$_2$H$^-$/C$_4$H$^-$, in agreement with chemical model predictions. At higher ionospheric altitudes, detections at 73-74 u/q could be attributed to the further carbon chain anions C$_5$N$^-$/C$_6$H$^-$ but at lower altitudes and during further encounters, extend over a higher mass/charge range. This, as well as further intermediary anions detected at $>$100 u, provide the first evidence for efficient anion chemistry in space involving structures other than linear chains. Furthermore, at altitudes below $\sim$1100 km, the low mass anions ($<$150 u/q) were found to deplete at a rate proportional to the growth of the larger molecules, a correlation that indicates the anions are tightly coupled to the growth process. This study adds Titan to an increasing list of astrophysical environments where chain anions have been observed and shows that anion chemistry plays a role in the formation of complex organics within a planetary atmosphere as well as in the interstellar medium.
△ Less
Submitted 6 June, 2017;
originally announced June 2017.
-
The relative and absolute timing accuracy of the EPIC-pn camera on XMM-Newton, from X-ray pulsations of the Crab and other pulsars
Authors:
A. Martin-Carrillo,
M. G. F. Kirsch,
I. Caballero,
M. J. Freyberg,
A. Ibarra,
E. Kendziorra,
U. Lammers,
K. Mukerjee,
G. Schönherr,
M. Stuhlinger,
R. D. Saxton,
R. Staubert,
S. Suchy,
A. Wellbrock,
N. Webb,
M. Guainazzi
Abstract:
Reliable timing calibration is essential for the accurate comparison of XMM-Newton light curves with those from other observatories, to ultimately use them to derive precise physical quantities. The XMM-Newton timing calibration is based on pulsar analysis. However, as pulsars show both timing noise and glitches, it is essential to monitor these calibration sources regularly. To this end, the XMM-…
▽ More
Reliable timing calibration is essential for the accurate comparison of XMM-Newton light curves with those from other observatories, to ultimately use them to derive precise physical quantities. The XMM-Newton timing calibration is based on pulsar analysis. However, as pulsars show both timing noise and glitches, it is essential to monitor these calibration sources regularly. To this end, the XMM-Newton observatory performs observations twice a year of the Crab pulsar to monitor the absolute timing accuracy of the EPIC-pn camera in the fast Timing and Burst modes. We present the results of this monitoring campaign, comparing XMM-Newton data from the Crab pulsar (PSR B0531+21) with radio measurements. In addition, we use five pulsars (PSR J0537-69, PSR B0540-69, PSR B0833-45, PSR B1509-58 and PSR B1055-52) with periods ranging from 16 ms to 197 ms to verify the relative timing accuracy. We analysed 38 XMM-Newton observations (0.2-12.0 keV) of the Crab taken over the first ten years of the mission and 13 observations from the five complementary pulsars. All the data were processed with the SAS, the XMM-Newton Scientific Analysis Software, version 9.0. Epoch folding techniques coupled with χ^{2} tests were used to derive relative timing accuracies. The absolute timing accuracy was determined using the Crab data and comparing the time shift between the main X-ray and radio peaks in the phase folded light curves. The relative timing accuracy of XMM-Newton is found to be better than 10^{-8}. The strongest X-ray pulse peak precedes the corresponding radio peak by 306\pm9 \mus, which is in agreement with other high energy observatories such as Chandra, INTEGRAL and RXTE. The derived absolute timing accuracy from our analysis is \pm48 \mus.
△ Less
Submitted 4 April, 2012;
originally announced April 2012.