-
Increased muon field at surface and substrate interface of palladium thin films
Authors:
Gesa Welker,
Martin de Wit,
Tjerk H. Oosterkamp,
John A. Mydosh,
Andreas Suter,
Thomas Prokscha,
Lucia Bossoni
Abstract:
We performed depth-dependent low-energy muon spin spectroscopy ($μ$SR) studies on three palladium 100 nm thin films, both undoped and doped with 170 ppm of iron. Muons implanted in the surface and substrate interface region probe an increased local magnetic field compared to the inner part of the sample. The field increase extends over a few nanometers, it is temperature-independent (in the range…
▽ More
We performed depth-dependent low-energy muon spin spectroscopy ($μ$SR) studies on three palladium 100 nm thin films, both undoped and doped with 170 ppm of iron. Muons implanted in the surface and substrate interface region probe an increased local magnetic field compared to the inner part of the sample. The field increase extends over a few nanometers, it is temperature-independent (in the range of 3.7 - 100 K), stronger for the iron-doped samples and accompanied by an increase in local field inhomogeneity. We consider various potential origins for this magnetic surface state, such as adsorbents and supressed d-states. Our conclusion is that orbital moments induced at the surface / interface by localized spins and charges are the most likely explanation, potentially accompanied by magnetic moments due to crystal irregularities.
△ Less
Submitted 5 September, 2022;
originally announced September 2022.
-
Probing interacting two-level systems with rare-earth ions
Authors:
Dapeng Ding,
David van Driel,
Lino M. C. Pereira,
Jared F. Bauters,
Martijn J. R. Heck,
Gesa Welker,
Michiel J. A. de Dood,
André Vantomme,
John E. Bowers,
Wolfgang Löffler,
Dirk Bouwmeester
Abstract:
Two-level systems (TLS) in amorphous materials limit coherence times of a number of solid-state quantum devices. Interactions between TLS become prominent below 100 mK, but the coupling mechanism and statistical properties are still unclear. Here we determine the homogeneous linewidth of ytterbium ions (Yb$ ^{3+} $) in silica glass at 10-80 mK by using photon echo techniques as a probe of TLS. Fir…
▽ More
Two-level systems (TLS) in amorphous materials limit coherence times of a number of solid-state quantum devices. Interactions between TLS become prominent below 100 mK, but the coupling mechanism and statistical properties are still unclear. Here we determine the homogeneous linewidth of ytterbium ions (Yb$ ^{3+} $) in silica glass at 10-80 mK by using photon echo techniques as a probe of TLS. First, the homogeneous linewidth can be reduced by applying a magnetic field of 0.3 T. This effect is due to reduced magnetic interactions between adjacent Yb$ ^{3+} $. Secondly, we observe saturation of the linewidth below 50 mK to a level of approximately 30 kHz, which is much larger than the lifetime-limited value of 0.2 kHz. This saturation behavior is in conflict with the coupling to independent TLS. We show that this effect can be explained by coherently coupled TLS.
△ Less
Submitted 29 January, 2020; v1 submitted 13 November, 2018;
originally announced November 2018.
-
Flux compensation for SQUID-detected Magnetic Resonance Force Microscopy
Authors:
Martin de Wit,
Gesa Welker,
Frederik G. Hoekstra,
Tjerk H. Oosterkamp
Abstract:
One of the major challenges in performing SQUID-detected Magnetic Resonance Force Microscopy (MRFM) at milliKelvin temperatures is the crosstalk between the radiofrequency (RF) pulses used for the spin manipulation and the SQUID-based detection mechanism. Here we present an approach based on balancing the flux crosstalk using an on-chip feedback coil coupled to the SQUID. This approach does not re…
▽ More
One of the major challenges in performing SQUID-detected Magnetic Resonance Force Microscopy (MRFM) at milliKelvin temperatures is the crosstalk between the radiofrequency (RF) pulses used for the spin manipulation and the SQUID-based detection mechanism. Here we present an approach based on balancing the flux crosstalk using an on-chip feedback coil coupled to the SQUID. This approach does not require any additional components near the location of the sample, and can therefore be applied to any SQUID-based detection scheme to cancel predictable RF interference. We demonstrate the effectiveness of our approach by showing that we can almost completely negate flux crosstalk with an amplitude of up to several $Φ_0$. This technical achievement allows for complicated magnetic resonance protocols to be performed at temperatures below 50 mK.
△ Less
Submitted 30 October, 2018;
originally announced October 2018.
-
Vibration isolation with high thermal conductance for a cryogen-free dilution refrigerator
Authors:
Martin de Wit,
Gesa Welker,
Kier Heeck,
Frank M. Buters,
Hedwig J. Eerkens,
Gert Koning,
Harmen van der Meer,
Dirk Bouwmeester,
Tjerk H. Oosterkamp
Abstract:
We present the design and implementation of a mechanical low-pass filter vibration isolation used to reduce the vibrational noise in a cryogen-free dilution refrigerator operated at 10 mK, intended for scanning probe techniques. We discuss the design guidelines necessary to meet the competing requirements of having a low mechanical stiffness in combination with a high thermal conductance. We demon…
▽ More
We present the design and implementation of a mechanical low-pass filter vibration isolation used to reduce the vibrational noise in a cryogen-free dilution refrigerator operated at 10 mK, intended for scanning probe techniques. We discuss the design guidelines necessary to meet the competing requirements of having a low mechanical stiffness in combination with a high thermal conductance. We demonstrate the effectiveness of our approach by measuring the vibrational noise levels of an ultrasoft mechanical resonator positioned above a SQUID. Starting from a cryostat base temperature of 8 mK, the vibration isolation can be cooled to 10.5 mK, with a cooling power of 113 $μ$W at 100 mK. We use the low vibrations and low temperature to demonstrate an effective cantilever temperature of less than 20 mK. This results in a force sensitivity of less than 500 zN/$\sqrt{\mathrm{Hz}}$, and an integrated frequency noise as low as 0.4 mHz in a 1 Hz measurement bandwidth.
△ Less
Submitted 16 October, 2018;
originally announced October 2018.
-
Feasibility of imaging using Boltzmann polarization in nuclear Magnetic Resonance Force Microscopy
Authors:
Martin de Wit,
Gesa Welker,
Jelmer Wagenaar,
Freek Hoekstra,
Tjerk Oosterkamp
Abstract:
We report on Magnetic Resonance Force Microscopy measurements of the Boltzmann polarization of the nuclear spins in copper by detecting the frequency shift of a soft cantilever. We use the time-dependent solution of the Bloch equations to derive a concise equation describing the effect of rf magnetic fields on both on- and off-resonant spins in high magnetic field gradients. We then apply this the…
▽ More
We report on Magnetic Resonance Force Microscopy measurements of the Boltzmann polarization of the nuclear spins in copper by detecting the frequency shift of a soft cantilever. We use the time-dependent solution of the Bloch equations to derive a concise equation describing the effect of rf magnetic fields on both on- and off-resonant spins in high magnetic field gradients. We then apply this theory to saturation experiments performed on a 100 nm thick layer of copper, where we use the higher modes of the cantilever as source of the rf field. We demonstrate a detection volume sensitivity of only (40 nm)$^3$, corresponding to about 1.6$\cdot 10^4$ polarized copper nuclear spins. We propose an experiment on protons where, with the appropriate technical improvements, frequency-shift based magnetic resonance imaging with a resolution better than (10 nm)$^3$ could be possible. Achieving this resolution would make imaging based on the Boltzmann polarization competitive with the more traditional stochastic spin-fluctuation based imaging, with the possibility to work at milliKelvin temperatures.
△ Less
Submitted 25 September, 2018;
originally announced September 2018.
-
Density and $T_1$ of surface and bulk spins in diamond in high magnetic field gradients
Authors:
Martin de Wit,
Gesa Welker,
Marc de Voogd,
Tjerk Oosterkamp
Abstract:
We report on surface and bulk spin density measurements of diamond, using ultra-sensitive magnetic force microscopy with magnetic field gradients up to 0.5 T/$μ$m. At temperatures between 25 and 800 mK, we measure the shifts in the resonance frequency and quality factor of a cantilever with a micromagnet attached to it. A recently developed theoretical analysis allows us to extract a surface spin…
▽ More
We report on surface and bulk spin density measurements of diamond, using ultra-sensitive magnetic force microscopy with magnetic field gradients up to 0.5 T/$μ$m. At temperatures between 25 and 800 mK, we measure the shifts in the resonance frequency and quality factor of a cantilever with a micromagnet attached to it. A recently developed theoretical analysis allows us to extract a surface spin density of 0.072 spins/nm$^2$ and a bulk spin density of 0.4 ppm from this data. In addition, we find an increase of the $T_1$ time of the surface spins in high magnetic field gradients due to the suppression of spin diffusion. Our technique is applicable to a variety of samples other than diamond, and could be of interest for several research fields where surface, interface or impurity bulk spin densities are an important factor.
△ Less
Submitted 23 January, 2018;
originally announced January 2018.
-
Nested Trampoline Resonators for Optomechanics
Authors:
Matthew J. Weaver,
Brian Pepper,
Fernando Luna,
Frank M. Buters,
Hedwig J. Eerkens,
Gesa Welker,
Blaise Perock,
Kier Heeck,
Sven de Man,
Dirk Bouwmeester
Abstract:
Two major challenges in the development of optomechanical devices are achieving a low mechanical and optical loss rate and vibration isolation from the environment. We address both issues by fabricating trampoline resonators made from low pressure chemical vapor deposition (LPCVD) Si$_3$N$_4$ with a distributed bragg reflector (DBR) mirror. We design a nested double resonator structure with 80 dB…
▽ More
Two major challenges in the development of optomechanical devices are achieving a low mechanical and optical loss rate and vibration isolation from the environment. We address both issues by fabricating trampoline resonators made from low pressure chemical vapor deposition (LPCVD) Si$_3$N$_4$ with a distributed bragg reflector (DBR) mirror. We design a nested double resonator structure with 80 dB of mechanical isolation from the mounting surface at the inner resonator frequency, and we demonstrate up to 45 dB of isolation at lower frequencies in agreement with the design. We reliably fabricate devices with mechanical quality factors of around 400,000 at room temperature. In addition these devices were used to form optical cavities with finesse up to 181,000 $\pm$ 1,000. These promising parameters will enable experiments in the quantum regime with macroscopic mechanical resonators.
△ Less
Submitted 6 January, 2016; v1 submitted 1 October, 2015;
originally announced October 2015.