Ultrafast 3-D Super Resolution Ultrasound using Row-Column Array specific Coherence-based Beamforming and Rolling Acoustic Sub-aperture Processing: In Vitro, In Vivo and Clinical Study
Authors:
Joseph Hansen-Shearer,
Jipeng Yan,
Marcelo Lerendegui,
Biao Huang,
Matthieu Toulemonde,
Kai Riemer,
Qingyuan Tan,
Johanna Tonko,
Peter D. Weinberg,
Chris Dunsby,
Meng-Xing Tang
Abstract:
The row-column addressed array is an emerging probe for ultrafast 3-D ultrasound imaging. It achieves this with far fewer independent electronic channels and a wider field of view than traditional 2-D matrix arrays, of the same channel count, making it a good candidate for clinical translation. However, the image quality of row-column arrays is generally poor, particularly when investigating tissu…
▽ More
The row-column addressed array is an emerging probe for ultrafast 3-D ultrasound imaging. It achieves this with far fewer independent electronic channels and a wider field of view than traditional 2-D matrix arrays, of the same channel count, making it a good candidate for clinical translation. However, the image quality of row-column arrays is generally poor, particularly when investigating tissue. Ultrasound localisation microscopy allows for the production of super-resolution images even when the initial image resolution is not high. Unfortunately, the row-column probe can suffer from imaging artefacts that can degrade the quality of super-resolution images as `secondary' lobes from bright microbubbles can be mistaken as microbubble events, particularly when operated using plane wave imaging. These false events move through the image in a physiologically realistic way so can be challenging to remove via tracking, leading to the production of 'false vessels'. Here, a new type of rolling window image reconstruction procedure was developed, which integrated a row-column array-specific coherence-based beamforming technique with acoustic sub-aperture processing for the purposes of reducing `secondary' lobe artefacts, noise and increasing the effective frame rate. Using an {\it{in vitro}} cross tube, it was found that the procedure reduced the percentage of `false' locations from $\sim$26\% to $\sim$15\% compared to traditional orthogonal plane wave compounding. Additionally, it was found that the noise could be reduced by $\sim$7 dB and that the effective frame rate could be increased to over 4000 fps. Subsequently, {\it{in vivo}} ultrasound localisation microscopy was used to produce images non-invasively of a rabbit kidney and a human thyroid.
△ Less
Submitted 15 November, 2023;
originally announced November 2023.
-
On the Use of Singular Value Decomposition as a Clutter Filter for Ultrasound Flow Imaging
Authors:
Kai Riemer,
Marcelo Lerendegui,
Matthieu Toulemonde,
Jiaqi Zhu,
Christopher Dunsby,
Peter D. Weinberg,
Meng-Xing Tang
Abstract:
Filtering based on Singular Value Decomposition (SVD) provides substantial separation of clutter, flow and noise in high frame rate ultrasound flow imaging. The use of SVD as a clutter filter has greatly improved techniques such as vector flow imaging, functional ultrasound and super-resolution ultrasound localization microscopy. The removal of clutter and noise relies on the assumption that tissu…
▽ More
Filtering based on Singular Value Decomposition (SVD) provides substantial separation of clutter, flow and noise in high frame rate ultrasound flow imaging. The use of SVD as a clutter filter has greatly improved techniques such as vector flow imaging, functional ultrasound and super-resolution ultrasound localization microscopy. The removal of clutter and noise relies on the assumption that tissue, flow and noise are each represented by different subsets of singular values, so that their signals are uncorrelated and lay on orthogonal sub-spaces. This assumption fails in the presence of tissue motion, for near-wall or microvascular flow, and can be influenced by an incorrect choice of singular value thresholds. Consequently, separation of flow, clutter and noise is imperfect, which can lead to image artefacts not present in the original data. Temporal and spatial fluctuation in intensity are the commonest artefacts, which vary in appearance and strengths. Ghosting and splitting artefacts are observed in the microvasculature where the flow signal is sparsely distributed. Singular value threshold selection, tissue motion, frame rate, flow signal amplitude and acquisition length affect the prevalence of these artefacts. Understanding what causes artefacts due to SVD clutter and noise removal is necessary for their interpretation.
△ Less
Submitted 25 April, 2023;
originally announced April 2023.
-
Investigating biomechanical determinants of endothelial permeability in a modified hollow fibre bioreactor
Authors:
Stephen G Gray,
Peter D Weinberg
Abstract:
Effects of mechanical stress on the permeability of vascular endothelium are important to normal physiology and may be critical in the development of atherosclerosis, where they can account for the patchy arterial distribution of the disease. Such properties are frequently investigated in vitro. Here we evaluate and use the hollow fibre bioreactor for this purpose; in this system, endothelial cell…
▽ More
Effects of mechanical stress on the permeability of vascular endothelium are important to normal physiology and may be critical in the development of atherosclerosis, where they can account for the patchy arterial distribution of the disease. Such properties are frequently investigated in vitro. Here we evaluate and use the hollow fibre bioreactor for this purpose; in this system, endothelial cells form a confluent monolayer lining numerous plastic capillaries with porous walls, contained in a cartridge. The capillaries were perfused with a near-aortic waveform by an external pump, and permeability was assessed by the movement of rhodamine-labelled albumin from the intracapillary space to the extracapillary space. Confluence and quiescence of the cells was confirmed by electron microscopy and measurements of glucose consumption and permeability. The system was able to detect previously established influences on permeability: tracer transport was increased by acute application of shear stress and decreased by chronic shear stress compared to a static control, and was increased by thrombin or an NO synthase inhibitor under chronic shear. Increasing viscosity by addition of xanthan gum reduced permeability under both acute and chronic shear. Addition of dam** chambers to reduce flow pulsatility increased permeability. Modifying the cartridge to allow chronic convection across the monolayer increased effective permeability more than could be explained the addition of convective transport alone, indicating that it caused an increase in permeability. The off-the-shelf hollow fibre bioreactor provides an excellent system for investigating the biomechanics of endothelial permeability and its potential is increased by simple modifications.
△ Less
Submitted 2 March, 2023;
originally announced March 2023.
-
3D Super-Resolution Ultrasound with Adaptive Weight-Based Beamforming
Authors:
Jipeng Yan,
Bingxue Wang,
Kai Riemer,
Joseph Hansen-Shearer,
Marcelo Lerendegui,
Matthieu Toulemonde,
Christopher J Rowlands,
Peter D. Weinberg,
Meng-Xing Tang
Abstract:
Super-resolution ultrasound (SRUS) imaging through localising and tracking sparse microbubbles has been shown to reveal microvascular structure and flow beyond the wave diffraction limit. Most SRUS studies use standard delay and sum (DAS) beamforming, where large main lobe and significant side lobes make separation and localisation of densely distributed bubbles challenging, particularly in 3D due…
▽ More
Super-resolution ultrasound (SRUS) imaging through localising and tracking sparse microbubbles has been shown to reveal microvascular structure and flow beyond the wave diffraction limit. Most SRUS studies use standard delay and sum (DAS) beamforming, where large main lobe and significant side lobes make separation and localisation of densely distributed bubbles challenging, particularly in 3D due to the typically small aperture of matrix array probes. This study aims to improve 3D SRUS by implementing a low-cost 3D coherence beamformer based on channel signal variance, as well as two other adaptive weight-based coherence beamformers: nonlinear beamforming with p-th root compression and coherence factor. The 3D coherence beamformers, together with DAS, are compared in computer simulation, on a microflow phantom, and in vivo. Simulation results demonstrate that the adaptive weight-based beamformers can significantly narrow the main lobe and suppress the side lobes for modest computational cost. Significantly improved 3D SR images of microflow phantom and a rabbit kidney are obtained through the adaptive weight-based beamformers. The proposed variance-based beamformer performs best in simulations and experiments.
△ Less
Submitted 25 August, 2022;
originally announced August 2022.
-
Fast and selective super-resolution ultrasound in vivo with sono-switchable nanodroplets
Authors:
Kai Riemer,
Matthieu Toulemonde,
Jipeng Yan,
Marcelo Lerendegui,
Eleanor Stride,
Peter D. Weinberg,
Christopher Dunsby,
Meng-Xing Tang
Abstract:
Perfusion by the microcirculation is key to the development, maintenance and pathology of tissue. Its measurement with high spatiotemporal resolution is consequently valuable but remains a challenge in deep tissue. Ultrasound Localization Microscopy (ULM) provides very high spatiotemporal resolution but the use of microbubbles requires low contrast agent concentrations, a long acquisition time, an…
▽ More
Perfusion by the microcirculation is key to the development, maintenance and pathology of tissue. Its measurement with high spatiotemporal resolution is consequently valuable but remains a challenge in deep tissue. Ultrasound Localization Microscopy (ULM) provides very high spatiotemporal resolution but the use of microbubbles requires low contrast agent concentrations, a long acquisition time, and gives little control over the spatial and temporal distribution of the bubbles. The present study is the first to demonstrate Acoustic Wave Sparsely-Activated Localization Microscopy (AWSALM) and fast-AWSALM for in vivo super-resolution ultrasound imaging, offering contrast on demand and vascular selectivity. Three different formulations of sono-switchable contrast agents were tested. We demonstrate their use with ultrasound mechanical indices well within recommended safety limits to enable fast on-demand sparse switching at very high agent concentrations. We produce super-localization maps of the rabbit renal vasculature with acquisition times between 5.5 s and 0.25 s, and an 4-fold improvement in spatial resolution. We present the unique selectivity of AWSALM in visualizing specific vascular branches and downstream microvasculature, and we show super-localized kidney structures in systole and diastole with fast-AWSALM. In conclusion we demonstrate the feasibility of fast and selective measurement of microvascular dynamics in vivo with subwavelength resolution using ultrasound and sono-switchable nanodroplets.
△ Less
Submitted 8 March, 2022;
originally announced March 2022.