-
Construction of Precision sMDT Detector for ATLAS Muon Spectrometer Upgrade
Authors:
D. Amidei,
N. Anderson,
A. Chen,
E. Carpenter,
L. Cooperrider,
T. Dai,
E. Diehl,
C. Ferretti,
Y. Guo,
J. Li,
X. Meng,
K. Nelson,
V. Pillsbury,
E. Salzer,
T. Schwarz,
L. Simpson,
Z. Wang,
C. Weaverdyck,
C. Wei,
Z. Yang,
M. Yuan,
B. Zhou,
J. Zhu
Abstract:
This paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 microns. The positions of the platforms f…
▽ More
This paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of the first 30 chambers built at Michigan show that the drift tube wire position accuracy meets the specification of 20 microns. The positions of the platforms for alignment and magnetic field sensors are all installed well within the required precision. The cosmic ray test measurements show single wire tracking resolution of 100 +- 7 microns with an average detection efficiency above 99 %. The infrastructure, tooling, techniques, and procedures for chamber production are described in detail. The results from the chamber quality control tests of the first 30 constructed chambers are reported.
△ Less
Submitted 1 November, 2022;
originally announced November 2022.
-
Construction and testing of sMDT tubes at the University of Michigan for the ATLAS Muon Spectrometer upgrade
Authors:
C. Wei,
A. Chen,
D. Amidei,
N. Anderson,
E. Carpenter,
L. Cooperrider,
T. Dai,
E. Diehl,
C. Ferretti,
J. Li,
P. Lugato,
J. Minnella,
S. Moskaitis,
K. Nelson,
V. Pillsbury,
E. Salzer,
L. Simpson,
Z. C. Wang,
Z. R. Wang,
C. Weaverdyck,
Z. Yang,
B. Zhou
Abstract:
This paper reports on the design and construction of infrastructure and test stations for small-diameter monitored drift tube (sMDT) assembly and testing at the University of Michigan (UM) to prepare for the ATLAS Muon Spectrometer upgrade for the high-luminosity program of the Large Hadron Collider. Procedures of the tube assembly and quality assurance and control (QA/QC) tests are described in d…
▽ More
This paper reports on the design and construction of infrastructure and test stations for small-diameter monitored drift tube (sMDT) assembly and testing at the University of Michigan (UM) to prepare for the ATLAS Muon Spectrometer upgrade for the high-luminosity program of the Large Hadron Collider. Procedures of the tube assembly and quality assurance and control (QA/QC) tests are described in detail. More than 99% of the tubes meet the tube QA/QC specifications based on 2100 tubes built at UM. The UM test stations are also used for QA/QC testing on the tubes constructed at Michigan State University. These tubes are being used to construct the sMDT chambers which will replace the current MDT chambers of the barrel inner station of the Muon Spectrometer.
△ Less
Submitted 8 September, 2022;
originally announced September 2022.
-
Overview of the Instrumentation for the Dark Energy Spectroscopic Instrument
Authors:
B. Abareshi,
J. Aguilar,
S. Ahlen,
Shadab Alam,
David M. Alexander,
R. Alfarsy,
L. Allen,
C. Allende Prieto,
O. Alves,
J. Ameel,
E. Armengaud,
J. Asorey,
Alejandro Aviles,
S. Bailey,
A. Balaguera-Antolínez,
O. Ballester,
C. Baltay,
A. Bault,
S. F. Beltran,
B. Benavides,
S. BenZvi,
A. Berti,
R. Besuner,
Florian Beutler,
D. Bianchi
, et al. (242 additional authors not shown)
Abstract:
The Dark Energy Spectroscopic Instrument (DESI) has embarked on an ambitious five-year survey to explore the nature of dark energy with spectroscopy of 40 million galaxies and quasars. DESI will determine precise redshifts and employ the Baryon Acoustic Oscillation method to measure distances from the nearby universe to z > 3.5, as well as measure the growth of structure and probe potential modifi…
▽ More
The Dark Energy Spectroscopic Instrument (DESI) has embarked on an ambitious five-year survey to explore the nature of dark energy with spectroscopy of 40 million galaxies and quasars. DESI will determine precise redshifts and employ the Baryon Acoustic Oscillation method to measure distances from the nearby universe to z > 3.5, as well as measure the growth of structure and probe potential modifications to general relativity. In this paper we describe the significant instrumentation we developed for the DESI survey. The new instrumentation includes a wide-field, 3.2-deg diameter prime-focus corrector that focuses the light onto 5020 robotic fiber positioners on the 0.812 m diameter, aspheric focal surface. The positioners and their fibers are divided among ten wedge-shaped petals. Each petal is connected to one of ten spectrographs via a contiguous, high-efficiency, nearly 50 m fiber cable bundle. The ten spectrographs each use a pair of dichroics to split the light into three channels that together record the light from 360 - 980 nm with a resolution of 2000 to 5000. We describe the science requirements, technical requirements on the instrumentation, and management of the project. DESI was installed at the 4-m Mayall telescope at Kitt Peak, and we also describe the facility upgrades to prepare for DESI and the installation and functional verification process. DESI has achieved all of its performance goals, and the DESI survey began in May 2021. Some performance highlights include RMS positioner accuracy better than 0.1", SNR per \sqrtÅ > 0.5 for a z > 2 quasar with flux 0.28e-17 erg/s/cm^2/A at 380 nm in 4000s, and median SNR = 7 of the [OII] doublet at 8e-17 erg/s/cm^2 in a 1000s exposure for emission line galaxies at z = 1.4 - 1.6. We conclude with highlights from the on-sky validation and commissioning of the instrument, key successes, and lessons learned. (abridged)
△ Less
Submitted 22 May, 2022;
originally announced May 2022.
-
The Robotic Multi-Object Focal Plane System of the Dark Energy Spectroscopic Instrument (DESI)
Authors:
Joseph Harry Silber,
Parker Fagrelius,
Kevin Fanning,
Michael Schubnell,
Jessica Nicole Aguilar,
Steven Ahlen,
Jon Ameel,
Otger Ballester,
Charles Baltay,
Chris Bebek,
Dominic Benton Beard,
Robert Besuner,
Laia Cardiel-Sas,
Ricard Casas,
Francisco Javier Castander,
Todd Claybaugh,
Carl Dobson,
Yutong Duan,
Patrick Dunlop,
Jerry Edelstein,
William T. Emmet,
Ann Elliott,
Matthew Evatt,
Irena Gershkovich,
Julien Guy
, et al. (75 additional authors not shown)
Abstract:
A system of 5,020 robotic fiber positioners was installed in 2019 on the Mayall Telescope, at Kitt Peak National Observatory. The robots automatically re-target their optical fibers every 10 - 20 minutes, each to a precision of several microns, with a reconfiguration time less than 2 minutes. Over the next five years, they will enable the newly-constructed Dark Energy Spectroscopic Instrument (DES…
▽ More
A system of 5,020 robotic fiber positioners was installed in 2019 on the Mayall Telescope, at Kitt Peak National Observatory. The robots automatically re-target their optical fibers every 10 - 20 minutes, each to a precision of several microns, with a reconfiguration time less than 2 minutes. Over the next five years, they will enable the newly-constructed Dark Energy Spectroscopic Instrument (DESI) to measure the spectra of 35 million galaxies and quasars. DESI will produce the largest 3D map of the universe to date and measure the expansion history of the cosmos. In addition to the 5,020 robotic positioners and optical fibers, DESI's Focal Plane System includes 6 guide cameras, 4 wavefront cameras, 123 fiducial point sources, and a metrology camera mounted at the primary mirror. The system also includes associated structural, thermal, and electrical systems. In all, it contains over 675,000 individual parts. We discuss the design, construction, quality control, and integration of all these components. We include a summary of the key requirements, the review and acceptance process, on-sky validations of requirements, and lessons learned for future multi-object, fiber-fed spectrographs.
△ Less
Submitted 18 May, 2022;
originally announced May 2022.
-
Dark Energy Spectroscopic Instrument (DESI) Fiber Positioner Production
Authors:
Daniela Leitner,
Jessica Aguilar,
Jon Ameel,
Robert Besuner,
Todd Claybaugh,
Henry Heetderks,
Michael Schubnell,
Jean-Paul Kneib,
Joseph Silber,
Gregory Tarlé,
Curtis Weaverdyck,
Kai Zhang
Abstract:
The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 sq deg will be measured during the life of the experiment. A new prime focus corrector for the KPNO Mayall telescope will deliver light to 5000 fiber optic positioners. The f…
▽ More
The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 sq deg will be measured during the life of the experiment. A new prime focus corrector for the KPNO Mayall telescope will deliver light to 5000 fiber optic positioners. The fibers in turn feed ten broad-band spectrographs. We will describe the production and manufacturing processes developed for the 5000 fiber positioner robots mounted on the focal plane of the Mayall telescope.
△ Less
Submitted 25 July, 2018;
originally announced July 2018.
-
The DESI Experiment Part II: Instrument Design
Authors:
DESI Collaboration,
Amir Aghamousa,
Jessica Aguilar,
Steve Ahlen,
Shadab Alam,
Lori E. Allen,
Carlos Allende Prieto,
James Annis,
Stephen Bailey,
Christophe Balland,
Otger Ballester,
Charles Baltay,
Lucas Beaufore,
Chris Bebek,
Timothy C. Beers,
Eric F. Bell,
José Luis Bernal,
Robert Besuner,
Florian Beutler,
Chris Blake,
Hannes Bleuler,
Michael Blomqvist,
Robert Blum,
Adam S. Bolton,
Cesar Briceno
, et al. (268 additional authors not shown)
Abstract:
DESI (Dark Energy Spectropic Instrument) is a Stage IV ground-based dark energy experiment that will study baryon acoustic oscillations and the growth of structure through redshift-space distortions with a wide-area galaxy and quasar redshift survey. The DESI instrument is a robotically-actuated, fiber-fed spectrograph capable of taking up to 5,000 simultaneous spectra over a wavelength range from…
▽ More
DESI (Dark Energy Spectropic Instrument) is a Stage IV ground-based dark energy experiment that will study baryon acoustic oscillations and the growth of structure through redshift-space distortions with a wide-area galaxy and quasar redshift survey. The DESI instrument is a robotically-actuated, fiber-fed spectrograph capable of taking up to 5,000 simultaneous spectra over a wavelength range from 360 nm to 980 nm. The fibers feed ten three-arm spectrographs with resolution $R= λ/Δλ$ between 2000 and 5500, depending on wavelength. The DESI instrument will be used to conduct a five-year survey designed to cover 14,000 deg$^2$. This powerful instrument will be installed at prime focus on the 4-m Mayall telescope in Kitt Peak, Arizona, along with a new optical corrector, which will provide a three-degree diameter field of view. The DESI collaboration will also deliver a spectroscopic pipeline and data management system to reduce and archive all data for eventual public use.
△ Less
Submitted 13 December, 2016; v1 submitted 31 October, 2016;
originally announced November 2016.
-
The DESI Experiment Part I: Science,Targeting, and Survey Design
Authors:
DESI Collaboration,
Amir Aghamousa,
Jessica Aguilar,
Steve Ahlen,
Shadab Alam,
Lori E. Allen,
Carlos Allende Prieto,
James Annis,
Stephen Bailey,
Christophe Balland,
Otger Ballester,
Charles Baltay,
Lucas Beaufore,
Chris Bebek,
Timothy C. Beers,
Eric F. Bell,
José Luis Bernal,
Robert Besuner,
Florian Beutler,
Chris Blake,
Hannes Bleuler,
Michael Blomqvist,
Robert Blum,
Adam S. Bolton,
Cesar Briceno
, et al. (268 additional authors not shown)
Abstract:
DESI (Dark Energy Spectroscopic Instrument) is a Stage IV ground-based dark energy experiment that will study baryon acoustic oscillations (BAO) and the growth of structure through redshift-space distortions with a wide-area galaxy and quasar redshift survey. To trace the underlying dark matter distribution, spectroscopic targets will be selected in four classes from imaging data. We will measure…
▽ More
DESI (Dark Energy Spectroscopic Instrument) is a Stage IV ground-based dark energy experiment that will study baryon acoustic oscillations (BAO) and the growth of structure through redshift-space distortions with a wide-area galaxy and quasar redshift survey. To trace the underlying dark matter distribution, spectroscopic targets will be selected in four classes from imaging data. We will measure luminous red galaxies up to $z=1.0$. To probe the Universe out to even higher redshift, DESI will target bright [O II] emission line galaxies up to $z=1.7$. Quasars will be targeted both as direct tracers of the underlying dark matter distribution and, at higher redshifts ($ 2.1 < z < 3.5$), for the Ly-$α$ forest absorption features in their spectra, which will be used to trace the distribution of neutral hydrogen. When moonlight prevents efficient observations of the faint targets of the baseline survey, DESI will conduct a magnitude-limited Bright Galaxy Survey comprising approximately 10 million galaxies with a median $z\approx 0.2$. In total, more than 30 million galaxy and quasar redshifts will be obtained to measure the BAO feature and determine the matter power spectrum, including redshift space distortions.
△ Less
Submitted 13 December, 2016; v1 submitted 31 October, 2016;
originally announced November 2016.
-
MiX: A Position Sensitive Dual-Phase Liquid Xenon Detector
Authors:
S. Stephenson,
J. Haefner,
Q. Lin,
K. Ni,
K. Pushkin,
R. Raymond,
M. Schubnell,
N. Shutty,
G. Tarlé,
C. Weaverdyck,
W. Lorenzon
Abstract:
The need for precise characterization of dual-phase xenon detectors has grown as the technology has matured into a state of high efficacy for rare event searches. The Michigan Xenon detector was constructed to study the microphysics of particle interactions in liquid xenon across a large energy range in an effort to probe aspects of radiation detection in liquid xenon. We report the design and per…
▽ More
The need for precise characterization of dual-phase xenon detectors has grown as the technology has matured into a state of high efficacy for rare event searches. The Michigan Xenon detector was constructed to study the microphysics of particle interactions in liquid xenon across a large energy range in an effort to probe aspects of radiation detection in liquid xenon. We report the design and performance of a small 3D position sensitive dual-phase liquid xenon time projection chamber with high light yield ($L_y^{122}=15.2 $pe/keV at zero field), long electron lifetime ($τ> 200 μ$s), and excellent energy resolution ($σ/E = 1\%$ for 1,333 keV gamma rays in a drift field of 200 V/cm). Liquid xenon time projection chambers with such high energy resolution may find applications not only in dark matter direct detection searches, but also in neutrinoless double beta decay experiments and other applications.
△ Less
Submitted 26 October, 2015; v1 submitted 5 July, 2015;
originally announced July 2015.
-
The Dark Energy Camera
Authors:
B. Flaugher,
H. T. Diehl,
K. Honscheid,
T. M. C. Abbott,
O. Alvarez,
R. Angstadt,
J. T. Annis,
M. Antonik,
O. Ballester,
L. Beaufore,
G. M. Bernstein,
R. A. Bernstein,
B. Bigelow,
M. Bonati,
D. Boprie,
D. Brooks,
E. J. Buckley-Geer,
J. Campa,
L. Cardiel-Sas,
F. J. Castander,
J. Castilla,
H. Cease,
J. M. Cela-Ruiz,
S. Chappa,
E. Chi
, et al. (93 additional authors not shown)
Abstract:
The Dark Energy Camera is a new imager with a 2.2-degree diameter field of view mounted at the prime focus of the Victor M. Blanco 4-meter telescope on Cerro Tololo near La Serena, Chile. The camera was designed and constructed by the Dark Energy Survey Collaboration, and meets or exceeds the stringent requirements designed for the wide-field and supernova surveys for which the collaboration uses…
▽ More
The Dark Energy Camera is a new imager with a 2.2-degree diameter field of view mounted at the prime focus of the Victor M. Blanco 4-meter telescope on Cerro Tololo near La Serena, Chile. The camera was designed and constructed by the Dark Energy Survey Collaboration, and meets or exceeds the stringent requirements designed for the wide-field and supernova surveys for which the collaboration uses it. The camera consists of a five element optical corrector, seven filters, a shutter with a 60 cm aperture, and a CCD focal plane of 250 micron thick fully-depleted CCDs cooled inside a vacuum Dewar. The 570 Mpixel focal plane comprises 62 2kx4k CCDs for imaging and 12 2kx2k CCDs for guiding and focus. The CCDs have 15 microns x15 microns pixels with a plate scale of 0.263 arc sec per pixel. A hexapod system provides state-of-the-art focus and alignment capability. The camera is read out in 20 seconds with 6-9 electrons readout noise. This paper provides a technical description of the camera's engineering, construction, installation, and current status.
△ Less
Submitted 11 April, 2015;
originally announced April 2015.
-
First results with a microcavity plasma panel detector
Authors:
R. Ball,
M. Ben-Moshe,
Y. Benhammou,
R. Bensimon,
J. W. Chapman,
M. Davies,
E. Etzion,
C. Ferretti,
P. S. Friedman,
D. S. Levin,
Y. Silver,
R. L. Varner,
C. Weaverdyck,
B. Zhou
Abstract:
A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6 to 2.5 volt amplitude, fast rise time of approximately 2 ns and FWHM of about 2 ns with very uniform signal shapes across all pixels. From initial measurements with beta particles fro…
▽ More
A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6 to 2.5 volt amplitude, fast rise time of approximately 2 ns and FWHM of about 2 ns with very uniform signal shapes across all pixels. From initial measurements with beta particles from a radioactive source, a maximum pixel efficiency of greater than 95% is calculated, for operation of the detector over a 100V wide span of high voltages (HV). Over this same HV range, the background rate per pixel was measured to be 3 to 4 orders of magnitude lower than the rate with the cell illuminated by the beta source. Pixel-to-pixel count rate uniformity is within 3% and stable within 3% for many days. The time resolution is 2.4 ns, and a very low cell-to-cell crosstalk has been measured between cells separated by 2 mm.
△ Less
Submitted 3 December, 2014; v1 submitted 24 July, 2014;
originally announced July 2014.
-
Development of a plasma panel radiation detector
Authors:
R. Ball,
J. R. Beene,
M. Ben-Moshe,
Y. Benhammou,
R. Bensimon,
J. W. Chapman,
E. Etzion,
C. Ferretti,
P. S. Friedman,
D. S. Levin,
Y. Silver,
R. L. Varner,
C. Weaverdyck,
R. Wetzel,
B. Zhou,
T. Anderson,
K. McKinny,
E. H. Bentefour
Abstract:
This article reports on the development and experimental results of commercial plasma display panels adapted for their potential use as micropattern gas radiation detectors. The plasma panel sensors (PPS) design an materials include glass substrates, metal electrodes and inert gas mixtures which provide a physically robust, hermetically-sealed device. Plasma display panels used as detectors were t…
▽ More
This article reports on the development and experimental results of commercial plasma display panels adapted for their potential use as micropattern gas radiation detectors. The plasma panel sensors (PPS) design an materials include glass substrates, metal electrodes and inert gas mixtures which provide a physically robust, hermetically-sealed device. Plasma display panels used as detectors were tested with cosmic ray muons, beta rays and gamma rays, protons and thermal neutrons. The results demonstrated rise times and time resolution of a few nanoseconds, as well as sub-millimeter spatial resolution compatible with the pixel pitch.
△ Less
Submitted 14 June, 2014; v1 submitted 13 March, 2014;
originally announced March 2014.
-
Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 8: Instrumentation Frontier
Authors:
M. Demarteau,
R. Lipton,
H. Nicholson,
I. Shipsey,
D. Akerib,
A. Albayrak-Yetkin,
J. Alexander,
J. Anderson,
M. Artuso,
D. Asner,
R. Ball,
M. Battaglia,
C. Bebek,
J. Beene,
Y. Benhammou,
E. Bentefour,
M. Bergevin,
A. Bernstein,
B. Bilki,
E. Blucher,
G. Bolla,
D. Bortoletto,
N. Bowden,
G. Brooijmans,
K. Byrum
, et al. (189 additional authors not shown)
Abstract:
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and iss…
▽ More
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and issues of gathering resources for long-term research in this area.
△ Less
Submitted 23 January, 2014;
originally announced January 2014.
-
Plasma panel-based radiation detectors
Authors:
Peter Friedman,
Robert Ball,
James Beene,
Yan Benhammou,
Meny Ben-Moshe,
Hassan Bentefour,
J. W. Chapman,
Erez Etzion,
Claudio Ferretti,
Daniel Levin,
Yiftah Silver,
Robert Varner,
Curtis Weaverdyck,
Bing Zhou
Abstract:
The plasma panel sensor (PPS) is a gaseous micropattern radiation detector under current development. It has many operational and fabrication principles common to plasma display panels. It comprises a dense matrix of small, gas plasma discharge cells within a hermetically sealed panel. As in plasma display panels, it uses nonreactive, intrinsically radiation-hard materials such as glass substrates…
▽ More
The plasma panel sensor (PPS) is a gaseous micropattern radiation detector under current development. It has many operational and fabrication principles common to plasma display panels. It comprises a dense matrix of small, gas plasma discharge cells within a hermetically sealed panel. As in plasma display panels, it uses nonreactive, intrinsically radiation-hard materials such as glass substrates, refractory metal electrodes, and mostly inert gas mixtures. We are develo** these devices primarily as thin, low-mass detectors with gas gaps from a few hundred microns to a few millimeters. The PPS is a high gain, inherently digital device with the potential for fast response times, fine position resolution (<50-mm RMS) and low cost. In this paper, we report on prototype PPS experimental results in detecting betas, protons, and cosmic muons, and we extrapolate on the PPS potential for applications including the detection of alphas, heavy ions at low-to-medium energy, thermal neutrons, and X-rays.
△ Less
Submitted 10 May, 2013;
originally announced May 2013.
-
Plasma Panel Sensors for Particle and Beam Detection
Authors:
Peter S. Friedman,
Robert Ball,
James R. Beene,
Yan Benhammou,
E. H. Bentefour,
J. W. Chapman,
Erez Etzion,
Claudio Ferretti,
Nir Guttman,
Daniel S. Levin,
Meny Ben-Moshe,
Yiftah Silver,
Robert L. Varner,
Curtis Weaverdyck,
Bing Zhou
Abstract:
The plasma panel sensor (PPS) is an inherently digital, high gain, novel variant of micropattern gas detectors inspired by many operational and fabrication principles common to plasma display panels (PDPs). The PPS is comprised of a dense array of small, plasma discharge, gas cells within a hermetically-sealed glass panel, and is assembled from non-reactive, intrinsically radiation-hard materials…
▽ More
The plasma panel sensor (PPS) is an inherently digital, high gain, novel variant of micropattern gas detectors inspired by many operational and fabrication principles common to plasma display panels (PDPs). The PPS is comprised of a dense array of small, plasma discharge, gas cells within a hermetically-sealed glass panel, and is assembled from non-reactive, intrinsically radiation-hard materials such as glass substrates, metal electrodes and mostly inert gas mixtures. We are develo** the technology to fabricate these devices with very low mass and small thickness, using gas gaps of at least a few hundred micrometers. Our tests with these devices demonstrate a spatial resolution of about 1 mm. We intend to make PPS devices with much smaller cells and the potential for much finer position resolutions. Our PPS tests also show response times of several nanoseconds. We report here our results in detecting betas, cosmic-ray muons, and our first proton beam tests.
△ Less
Submitted 22 November, 2012;
originally announced November 2012.
-
Development of a plasma panel radiation detector: recent progress and key issues
Authors:
Yiftah Silver,
Robert Ball,
James R. Beene,
Yan Benhammou,
Meny Ben-Moshe,
J. W. Chapman,
Tiesheng Dai,
Erez Etzion,
Claudio Ferretti,
Nir Guttman,
Peter S. Friedman,
Daniel S. Levin,
S. Ritt,
Robert L. Varner,
Curtis Weaverdyck,
Bing Zhou
Abstract:
A radiation detector based on plasma display panel technology, which is the principal component of plasma television displays is presented. Plasma Panel Sensor (PPS) technology is a variant of micropattern gas radiation detectors. The PPS is conceived as an array of sealed plasma discharge gas cells which can be used for fast response (O(5ns) per pixel), high spatial resolution detection (pixel pi…
▽ More
A radiation detector based on plasma display panel technology, which is the principal component of plasma television displays is presented. Plasma Panel Sensor (PPS) technology is a variant of micropattern gas radiation detectors. The PPS is conceived as an array of sealed plasma discharge gas cells which can be used for fast response (O(5ns) per pixel), high spatial resolution detection (pixel pitch can be less than 100 micrometer) of ionizing and minimum ionizing particles. The PPS is assembled from non-reactive, intrinsically radiation-hard materials: glass substrates, metal electrodes and inert gas mixtures. We report on the PPS development program, including simulations and design and the first laboratory studies which demonstrate the usage of plasma display panels in measurements of cosmic ray muons, as well as the expansion of experimental results on the detection of betas from radioactive sources.
△ Less
Submitted 30 May, 2012;
originally announced May 2012.
-
The Detection of Ionizing Radiation by Plasma Panel Sensors: Cosmic Muons, Ion Beams and Cancer Therapy
Authors:
Peter S. Friedman,
Robert Ball,
J. W. Chapman,
Claudio Ferretti,
Daniel S. Levin,
Curtis Weaverdyck,
Bing Zhou,
Yan Benhammou,
Erez Etzion,
Nir Guttman,
M. Ben Moshe,
Yiftah Silver,
James R. Beene,
Robert L. Varner Jr.
Abstract:
The plasma panel sensor is an ionizing photon and particle radiation detector derived from PDP technology with high gain and nanosecond response. Experimental results in detecting cosmic ray muons and beta particles from radioactive sources are described along with applications including high energy and nuclear physics, homeland security and cancer therapeutics
The plasma panel sensor is an ionizing photon and particle radiation detector derived from PDP technology with high gain and nanosecond response. Experimental results in detecting cosmic ray muons and beta particles from radioactive sources are described along with applications including high energy and nuclear physics, homeland security and cancer therapeutics
△ Less
Submitted 3 April, 2012;
originally announced April 2012.
-
Reciprocity Failure in HgCdTe Detectors: Measurements and Mitigation
Authors:
T. Biesiadzinski,
W. Lorenzon,
R. Newman,
M. Schubnell,
G. Tarle,
C. Weaverdyck
Abstract:
A detailed study of reciprocity failure in four 1.7 micron cutoff HgCdTe near-infrared detectors is presented. The sensitivity to reciprocity failure is approximately 0.1%\decade over up to five orders of magnitude in illumination intensity. The four detectors, which represent three successive production runs with modified growth recipes, show large differences in amount and spatial structure of r…
▽ More
A detailed study of reciprocity failure in four 1.7 micron cutoff HgCdTe near-infrared detectors is presented. The sensitivity to reciprocity failure is approximately 0.1%\decade over up to five orders of magnitude in illumination intensity. The four detectors, which represent three successive production runs with modified growth recipes, show large differences in amount and spatial structure of reciprocity failure. Reciprocity failure could be reduced to negligible levels by cooling the detectors to about 110 K. No wavelength dependence was observed. The observed spatial structure appears to be weakly correlated with image persistence.
△ Less
Submitted 6 June, 2011;
originally announced June 2011.
-
Streamlined Calibrations of the ATLAS Precision Muon Chambers for Initial LHC Running
Authors:
N. Amram,
R. Ball,
Y. Benhammou,
M. Ben Moshe,
T. Dai,
E. B. Diehl,
J. Dubbert,
E. Etzion,
C. Ferretti,
J. Gregory,
S. Haider,
J. Hindes,
D. S. Levin,
R. Thun,
A. Wilson,
C. Weaverdyck,
Y. Wu,
H. Yang,
B. Zhou,
S. Zimmermann
Abstract:
The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p = 3% and 10% at 100 GeV and 1 TeV momentum respectively. For this task, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) arrayed in 1200 Chambers. Calibration (RT) functions convert drift time measurements into tube-centered impact parameters for track segment reconstruction. RT function…
▽ More
The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p = 3% and 10% at 100 GeV and 1 TeV momentum respectively. For this task, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) arrayed in 1200 Chambers. Calibration (RT) functions convert drift time measurements into tube-centered impact parameters for track segment reconstruction. RT functions depend on MDT environmental parameters and so must be appropriately calibrated for local chamber conditions. We report on the creation and application of a gas monitor system based calibration program for muon track reconstruction in the LHC startup phase.
△ Less
Submitted 7 March, 2011; v1 submitted 3 March, 2011;
originally announced March 2011.
-
Progress in the Development of Plasma Panel Radiation Detectors
Authors:
Robert Ball,
James R. Beene,
Yan Benhammou,
Meny Ben Moshe,
J. Wehrley Chapman,
Tiesheng Dai,
Erez Etzion,
Peter S. Friedman,
Daniel S. Levin,
Yiftah Silver,
Guy Sherman,
Robert L. Varner Jr.,
Curtis Weaverdyck,
Steve White,
J. Yu,
Bing Zhou
Abstract:
Plasma Display Panels (PDP), the underlying engine of panel plasma television displays, are being investigated for their utility as radiation detectors called Plasma Panel Sensors (PPS). The PPS a novel variant of a micropattern radiation detector, is intended to be a fast, high resolution detector comprised of an array of plasma discharge cells operating in a hermetically sealed gas mixture. We r…
▽ More
Plasma Display Panels (PDP), the underlying engine of panel plasma television displays, are being investigated for their utility as radiation detectors called Plasma Panel Sensors (PPS). The PPS a novel variant of a micropattern radiation detector, is intended to be a fast, high resolution detector comprised of an array of plasma discharge cells operating in a hermetically sealed gas mixture. We report on the PPS development effort, including recent laboratory measurements.
△ Less
Submitted 30 December, 2010;
originally announced January 2011.
-
Measurement of Reciprocity Failure in Near Infrared Detectors
Authors:
T. Biesiadzinski,
W. Lorenzon,
R. Newman,
M. Schubnell,
G. Tarle,
C. Weaverdyck
Abstract:
Flux dependent non-linearity (reciprocity failure) in HgCdTe near infrared detectors can severely impact an instrument's performance, in particular with respect to precision photometric measurements. The cause of this effect is presently not understood. To investigate reciprocity failure, a dedicated test system was built. For flux levels between 1 and 50,000 photons/s, a sensitivity to reciprocit…
▽ More
Flux dependent non-linearity (reciprocity failure) in HgCdTe near infrared detectors can severely impact an instrument's performance, in particular with respect to precision photometric measurements. The cause of this effect is presently not understood. To investigate reciprocity failure, a dedicated test system was built. For flux levels between 1 and 50,000 photons/s, a sensitivity to reciprocity failure of approximately 0.1%/decade was achieved. A wavelength independent non-linearity due to reciprocity failure of about 0.35%/decade was measured in a 1.7 micron HgCdTe detector.
△ Less
Submitted 10 December, 2010;
originally announced December 2010.
-
Large-Area Plasma-Panel Radiation Detectors for Nuclear Medicine Imaging to Homeland Security and the Super Large Hadron Collider
Authors:
Peter S. Friedman,
Robert Ball,
J. Wehrley Chapman,
Daniel S. Levin,
Curtis Weaverdyck,
Bing Zhou,
Yan Benhammou,
Erez Etzion,
M. Ben Moshe,
Yiftah Silver,
James R. Beene,
Robert L. Varner Jr.
Abstract:
A new radiation sensor derived from plasma panel display technology is introduced. It has the capability to detect ionizing and non-ionizing radiation over a wide energy range and the potential for use in many applications. The principle of operation is described and some early results presented.
A new radiation sensor derived from plasma panel display technology is introduced. It has the capability to detect ionizing and non-ionizing radiation over a wide energy range and the potential for use in many applications. The principle of operation is described and some early results presented.
△ Less
Submitted 3 July, 2010;
originally announced July 2010.
-
Plasma Panel Detectors for MIP Detection for the SLHC and a Test Chamber Design
Authors:
Robert Ball,
John W. Chapman,
Erez Etzion,
Peter S. Friedman,
Daniel S. Levin,
Meny Ben Moshe,
Curtis Weaverdyck,
Bing Zhou
Abstract:
Performance demands for high and super-high luminosity at the LHC (up to 10^35 cm^(-2) sec^(-1) after the 2017 shutdown) and at future colliders demand high resolution tracking detectors with very fast time response and excellent temporal and spatial resolution. We are investigating a new radiation detector technology based on Plasma Display Panels (PDP), the underlying engine of panel plasma tele…
▽ More
Performance demands for high and super-high luminosity at the LHC (up to 10^35 cm^(-2) sec^(-1) after the 2017 shutdown) and at future colliders demand high resolution tracking detectors with very fast time response and excellent temporal and spatial resolution. We are investigating a new radiation detector technology based on Plasma Display Panels (PDP), the underlying engine of panel plasma television displays. The design and production of PDPs is supported by four decades of industrial development. Emerging from this television technology is the Plasma Panel Sensor (PPS), a novel variant of the micropattern radiation detector. The PPS is fundamentally an array of micro-Geiger plasma discharge cells operating in a non-ageing, hermetically sealed gas mixture . We report on the PPS development program, including design of a PPS Test Cell.
△ Less
Submitted 3 July, 2010;
originally announced July 2010.
-
Sub-Pixel Response Measurement of Near-Infrared Sensors
Authors:
N. Barron,
M. Borysow,
K. Beyerlein,
M. Brown,
C. Weaverdyck,
W. Lorenzon,
M. Schubnell,
G. Tarle,
A. Tomasch
Abstract:
Wide-field survey instruments are used to efficiently observe large regions of the sky. To achieve the necessary field of view, and to provide a higher signal-to-noise ratio for faint sources, many modern instruments are undersampled. However, precision photometry with undersampled imagers requires a detailed understanding of the sensitivity variations on a scale much smaller than a pixel. To ad…
▽ More
Wide-field survey instruments are used to efficiently observe large regions of the sky. To achieve the necessary field of view, and to provide a higher signal-to-noise ratio for faint sources, many modern instruments are undersampled. However, precision photometry with undersampled imagers requires a detailed understanding of the sensitivity variations on a scale much smaller than a pixel. To address this, a near-infrared spot projection system has been developed to precisely characterize near-infrared focal plane arrays and to study the effect of sub-pixel non uniformity on precision photometry. Measurements of large format near-infrared detectors demonstrate the power of this system for understanding sub-pixel response.
△ Less
Submitted 10 November, 2006;
originally announced November 2006.