-
Using graph neural networks to reconstruct charged pion showers in the CMS High Granularity Calorimeter
Authors:
M. Aamir,
B. Acar,
G. Adamov,
T. Adams,
C. Adloff,
S. Afanasiev,
C. Agrawal,
C. Agrawal,
A. Ahmad,
H. A. Ahmed,
S. Akbar,
N. Akchurin,
B. Akgul,
B. Akgun,
R. O. Akpinar,
E. Aktas,
A. AlKadhim,
V. Alexakhin,
J. Alimena,
J. Alison,
A. Alpana,
W. Alshehri,
P. Alvarez Dominguez,
M. Alyari,
C. Amendola
, et al. (550 additional authors not shown)
Abstract:
A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadr…
▽ More
A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadronic section. The shower reconstruction method is based on graph neural networks and it makes use of a dynamic reduction network architecture. It is shown that the algorithm is able to capture and mitigate the main effects that normally hinder the reconstruction of hadronic showers using classical reconstruction methods, by compensating for fluctuations in the multiplicity, energy, and spatial distributions of the shower's constituents. The performance of the algorithm is evaluated using test beam data collected in 2018 prototype of the CMS HGCAL accompanied by a section of the CALICE AHCAL prototype. The capability of the method to mitigate the impact of energy leakage from the calorimeter is also demonstrated.
△ Less
Submitted 30 June, 2024; v1 submitted 17 June, 2024;
originally announced June 2024.
-
Beneath the Surface: Revealing Deep-Tissue Blood Flow in Human Subjects with Massively Parallelized Diffuse Correlation Spectroscopy
Authors:
Lucas Kreiss,
Melissa Wu,
Michael Wayne,
Shiqi Xu,
Paul McKee,
Derrick Dwamena,
Kanghyun Kim,
Kyung Chul Lee,
Wenhui Liu,
Aarin Ulku,
Mark Harfouche,
Xi Yang,
Clare Cook,
Amey Chaware,
Seung Ah Lee,
Erin Buckley,
Claudio Bruschini,
Edoardo Charbon,
Scott Huettel,
Roarke Horstmeyer
Abstract:
Diffuse Correlation Spectroscopy (DCS) allows the label-free investigation of microvascular dynamics deep within living tissue. However, common implementations of DCS are currently limited to measurement depths of $\sim 1-1.5cm$, which can limit the accuracy of cerebral hemodynamics measurement. Here we present massively parallelized DCS (pDCS) using novel single photon avalanche detector (SPAD) a…
▽ More
Diffuse Correlation Spectroscopy (DCS) allows the label-free investigation of microvascular dynamics deep within living tissue. However, common implementations of DCS are currently limited to measurement depths of $\sim 1-1.5cm$, which can limit the accuracy of cerebral hemodynamics measurement. Here we present massively parallelized DCS (pDCS) using novel single photon avalanche detector (SPAD) arrays with up to 500x500 individual channels. The new SPAD array technology can boost the signal-to-noise ratio by a factor of up to 500 compared to single-pixel DCS, or by more than 15-fold compared to the most recent state-of-the-art pDCS demonstrations. Our results demonstrate the first in vivo use of this massively parallelized DCS system to measure cerebral blood flow changes at $\sim 2cm$ depth in human adults. We compared different modes of operation and applied a dual detection strategy, where a secondary SPAD array is used to simultaneously assess the superficial blood flow as a built-in reference measurement. While the blood flow in the superficial scalp tissue showed no significant change during cognitive activation, the deep pDCS measurement showed a statistically significant increase in the derived blood flow index of 8-12% when compared to the control rest state.
△ Less
Submitted 25 June, 2024; v1 submitted 6 March, 2024;
originally announced March 2024.
-
Study of time and energy resolution of an ultra-compact sampling calorimeter (RADiCAL) module at EM shower maximum over the energy range 25 GeV $\leq$ E $\leq$ 150 GeV
Authors:
Carlos Perez-Lara,
James Wetzel,
Ugur Akgun,
Thomas Anderson,
Thomas Barbera,
Dylan Blend,
Kerem Cankocak,
Salim Cerci,
Nehal Chigurupati,
Bradley Cox,
Paul Debbins,
Max Dubnowski,
Buse Duran,
Gizem Gul Dincer,
Selbi Hatipoglu,
Ilknur Hos,
Bora Isildak,
Colin Jessop,
Ohannes Kamer Koseyan,
Ayben Karasu Uysal,
Reyhan Kurt,
Berkan Kaynak,
Alexander Ledovskoy,
Alexi Mestvirishvili,
Yasar Onel
, et al. (14 additional authors not shown)
Abstract:
The RADiCAL Collaboration is conducting R\&D on high performance electromagnetic (EM) calorimetry to address the challenges expected in future collider experiments under conditions of high luminosity and/or high irradiation (FCC-ee, FCC-hh and fixed target and forward physics environments). Under development is a sampling calorimeter approach, known as RADiCAL modules, based on scintillation and w…
▽ More
The RADiCAL Collaboration is conducting R\&D on high performance electromagnetic (EM) calorimetry to address the challenges expected in future collider experiments under conditions of high luminosity and/or high irradiation (FCC-ee, FCC-hh and fixed target and forward physics environments). Under development is a sampling calorimeter approach, known as RADiCAL modules, based on scintillation and wavelength-shifting (WLS) technologies and photosensor, including SiPM and SiPM-like technology. The modules discussed herein consist of alternating layers of very dense (W) absorber and scintillating crystal (LYSO:Ce) plates, assembled to a depth of 25 $X_0$. The scintillation signals produced by the EM showers in the region of EM shower maximum (shower max) are transmitted to SiPM located at the upstream and downstream ends of the modules via quartz capillaries which penetrate the full length of the module. The capillaries contain DSB1 organic plastic WLS filaments positioned within the region of shower max, where the shower energy deposition is greatest, and fused with quartz rod elsewhere. The wavelength shifted light from this spatially-localized shower max region is then propagated to the photosensors. This paper presents the results of an initial measurement of the time resolution of a RADiCAL module over the energy range 25 GeV $\leq$ E $\leq$ 150 GeV using the H2 electron beam at CERN. The data indicate an energy dependence of the time resolution that follows the functional form: $σ_{t} = a/\sqrt{E} \oplus b$, where a = 256 $\sqrt{GeV}$~ps and b = 17.5 ps. The time resolution measured at the highest electron beam energy for which data was currently recorded (150 GeV) was found to be $σ_{t}$ = 27 ps.
△ Less
Submitted 3 January, 2024;
originally announced January 2024.
-
Demonstration of particle tracking with scintillating fibres read out by a SPAD array sensor and application as a neutrino active target
Authors:
Matthew Franks,
Till Dieminger,
Kodai Kaneyasu,
Davide Sgalaberna,
Claudio Bruschini,
Edoardo Charbon,
Umut Kose,
Botao Li,
Paul Mos,
Michael Wayne,
Tim Weber,
Jialin Wu
Abstract:
Scintillating fibre detectors combine sub-mm resolution particle tracking, precise measurements of the particle stop** power and sub-ns time resolution. Typically, fibres are read out with silicon photomultipliers (SiPM). Hence, if fibres with a few hundred $μ$m diameter are used, either they are grouped together and coupled with a single SiPM, losing spatial resolution, or a very large number o…
▽ More
Scintillating fibre detectors combine sub-mm resolution particle tracking, precise measurements of the particle stop** power and sub-ns time resolution. Typically, fibres are read out with silicon photomultipliers (SiPM). Hence, if fibres with a few hundred $μ$m diameter are used, either they are grouped together and coupled with a single SiPM, losing spatial resolution, or a very large number of electronic channels is required. In this article we propose and provide a first demonstration of a novel configuration which allows each individual scintillating fibre to be read out regardless of the size of its diameter, by imaging them with Single-Photon Avalanche Diode (SPAD) array sensors. Differently from SiPMs, SPAD array sensors provide single-photon detection with single-pixel spatial resolution. In addition, O(us) or faster coincidence of detected photons allows to obtain noise-free images. Such a concept can be particularly advantageous if adopted as a neutrino active target, where scintillating fibres alternated along orthogonal directions can provide isotropic, high-resolution tracking in a dense material and reconstruct the kinematics of low-momentum protons (down to 150 MeV/c), crucial for an accurate characterisation of the neutrino nucleus cross section. In this work the tracking capabilities of a bundle of scintillating fibres coupled to SwissSPAD2 is demonstrated. The impact of such detector configuration in GeV-neutrino experiments is studied with simulations and reported. Finally, future plans, including the development of a new SPAD array sensor optimised for neutrino detection, are discussed.
△ Less
Submitted 13 November, 2023; v1 submitted 6 September, 2023;
originally announced September 2023.
-
Integration of thermo-electric coolers into the CMS MTD SiPM arrays for operation under high neutron fluence
Authors:
A. Bornheim,
W. Lustermann,
K. Stachon,
G. Reales Gutiérrez,
A. Benaglia,
F. De Guio,
A. Ghezzi,
M. T. Lucchini,
M. Malberti,
S. Palluotto,
T. Tabarelli de Fatis,
M. Benettoni,
R. Carlin,
M. Tosi,
R. Rossin,
P. Meridiani,
R. Paramatti,
F. Santanastasio,
J. C. Silva,
J. Varela,
A. Heering,
A. Karneyeu,
Y. Musienko,
M. Wayne,
T. Anderson
, et al. (5 additional authors not shown)
Abstract:
The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read out with Silicon Photomultipliers (SiPMs). A major challenge for the operation of such a detector is the extremely high radiation level, of about…
▽ More
The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in the range of $30-60$ ps using LYSO:Ce crystal arrays read out with Silicon Photomultipliers (SiPMs). A major challenge for the operation of such a detector is the extremely high radiation level, of about $2\times10^{14}$ 1 MeV(Si) Eqv. n/cm$^2$, that will be integrated over a decade of operation of the High Luminosity Large Hadron Collider (HL-LHC). Silicon Photomultipliers exposed to this level of radiation have shown a strong increase in dark count rate and radiation damage effects that also impact their gain and photon detection efficiency. For this reason during operations the whole detector is cooled down to about $-35^{\circ}$C. In this paper we illustrate an innovative and cost-effective solution to mitigate the impact of radiation damage on the timing performance of the detector, by integrating small thermo-electric coolers (TECs) on the back of the SiPM package. This additional feature, fully integrated as part of the SiPM array, enables a further decrease in operating temperature down to about $-45^{\circ}$C. This leads to a reduction by a factor of about two in the dark count rate without requiring additional power budget, since the power required by the TEC is almost entirely offset by a decrease in the power required for the SiPM operation due to leakage current. In addition, the operation of the TECs with reversed polarity during technical stops of the accelerator can raise the temperature of the SiPMs up to $60^{\circ}$C (about $50^{\circ}$C higher than the rest of the detector), thus accelerating the annealing of radiation damage effects and partly recovering the SiPM performance.
△ Less
Submitted 23 August, 2023; v1 submitted 1 June, 2023;
originally announced June 2023.
-
Beam Test Results of the RADiCAL -- a Radiation Hard Innovative EM Calorimeter
Authors:
James Wetzel,
Dylan Blend,
Paul Debbins,
Max Hermann,
Ohannes Kamer Koseyan,
Gurkan Kamaran,
Yasar Onel,
Thomas Anderson,
Nehal Chigurupati,
Brad Cox,
Max Dubnowski,
Alexander Ledovskoy,
Carlos Perez-Lara,
Thomas Barbera,
Nilay Bostan,
Kiva Ford,
Colin Jessop,
Randal Ruchti,
Daniel Ruggiero,
Daniel Smith,
Mark Vigneault,
Yuyi Wan,
Mitchell Wayne,
Chen Hu,
Liyuan Zhang
, et al. (1 additional authors not shown)
Abstract:
High performance calorimetry conducted at future hadron colliders, such as the FCC-hh, poses a significant challenge for applying current detector technologies due to unprecedented beam luminosities and radiation fields. Solutions include develo** scintillators that are capable of separating events at the sub-fifty picosecond level while also maintaining performance after extreme and constant ne…
▽ More
High performance calorimetry conducted at future hadron colliders, such as the FCC-hh, poses a significant challenge for applying current detector technologies due to unprecedented beam luminosities and radiation fields. Solutions include develo** scintillators that are capable of separating events at the sub-fifty picosecond level while also maintaining performance after extreme and constant neutron and ionizing radiation exposure. The RADiCAL is an approach that incorporates radiation tolerant materials in a sampling 'shashlik' style calorimeter configuration, using quartz capillaries filled with organic liquid or polymer-based wavelength shifters embedded in layers of tungsten plates and LYSO crystals. This novel design intends to address the Priority Research Directions (PRD) for calorimetry listed in the DOE Basic Research Needs (BRN) workshop for HEP Instrumentation. Here we report preliminary results from an experimental run at the Fermilab Test Beam Facility in June 2022. These tests demonstrate that the RADiCAL concept is capable of < 50 ps timing resolution.
△ Less
Submitted 7 April, 2023; v1 submitted 9 March, 2023;
originally announced March 2023.
-
Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20$-$300 GeV/c
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
J. P. Figueiredo de sa Sousa de Almeida,
P. G. Dias de Almeida,
A. Alpana,
M. Alyari,
I. Andreev,
U. Aras,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Banerjee,
P. DeBarbaro,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (435 additional authors not shown)
Abstract:
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing med…
▽ More
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly readout by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.
△ Less
Submitted 27 May, 2023; v1 submitted 9 November, 2022;
originally announced November 2022.
-
RADiCAL: Precision-timing, Ultracompact, Radiation-hard Electromagnetic Calorimetry
Authors:
T. Anderson,
T. Barbera,
D. Blend,
N. Chigurupati,
B. Cox,
P. Debbins,
M. Dubnowski,
M. Herrmann,
C. Hu,
K. Ford,
C. Jessop,
O. Kamer-Koseyan,
G. Karaman,
A. Ledovskoy,
Y. Onel,
C. Perez-Lara,
R. Ruchti,
D. Ruggiero,
D. Smith,
M. Vigneault,
Y. Wan,
M. Wayne,
J. Wetzel,
L. Zhang,
R-Y. Zhu
Abstract:
To address the challenges of providing high performance calorimetry in future hadron collider experiments under conditions of high luminosity and high radiation (FCChh environments), we are conducting R&D on advanced calorimetry techniques suitable for such operation, based on scintillation and wavelength-shifting technologies and photosensor (SiPM and SiPM-like) technology. In particular, we are…
▽ More
To address the challenges of providing high performance calorimetry in future hadron collider experiments under conditions of high luminosity and high radiation (FCChh environments), we are conducting R&D on advanced calorimetry techniques suitable for such operation, based on scintillation and wavelength-shifting technologies and photosensor (SiPM and SiPM-like) technology. In particular, we are focusing our attention on ultra-compact radiation hard EM calorimeters, based on modular structures (RADiCAL modules) consisting of alternating layers of very dense absorber and scintillating plates, read out via radiation hard wavelength shifting (WLS) solid fiber or capillary elements to photosensors positioned either proximately or remotely, depending upon their radiation tolerance. The RADiCAL modules provide the capability to measure simultaneously and with high precision the position, energy and timing of EM showers. This paper provides an overview of the instrumentation and photosensor R&D associated with the RADiCAL program.
△ Less
Submitted 23 March, 2022;
originally announced March 2022.
-
Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
F. Alam Khan,
M. Alhusseini,
J. Alison,
A. Alpana,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Bannerjee,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (364 additional authors not shown)
Abstract:
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glu…
▽ More
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1 cm$^2$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.
△ Less
Submitted 31 March, 2022; v1 submitted 12 November, 2021;
originally announced November 2021.
-
Towards quantum 3D imaging devices: the Qu3D project
Authors:
Cristoforo Abbattista,
Leonardo Amoruso,
Samuel Burri,
Edoardo Charbon,
Francesco Di Lena,
Augusto Garuccio,
Davide Giannella,
Zdenek Hradil,
Michele Iacobellis,
Gianlorenzo Massaro,
Paul Mos,
Libor Motka,
Martin Paur,
Francesco V. Pepe,
Michal Peterek,
Isabella Petrelli,
Jaroslav Rehacek,
Francesca Santoro,
Francesco Scattarella,
Arin Ulku,
Sergii Vasiukov,
Michael Wayne,
Milena D'Angelo,
Claudio Bruschini,
Maria Ieronymaki
, et al. (1 additional authors not shown)
Abstract:
We review the advancement of the research toward the design and implementation of quantum plenoptic cameras, radically novel 3D imaging devices that exploit both momentum-position entanglement and photon-number correlations to provide the typical refocusing and ultra-fast, scanning-free, 3D imaging capability of plenoptic devices, along with dramatically enhanced performances, unattainable in stan…
▽ More
We review the advancement of the research toward the design and implementation of quantum plenoptic cameras, radically novel 3D imaging devices that exploit both momentum-position entanglement and photon-number correlations to provide the typical refocusing and ultra-fast, scanning-free, 3D imaging capability of plenoptic devices, along with dramatically enhanced performances, unattainable in standard plenoptic cameras: diffraction-limited resolution, large depth of focus, and ultra-low noise. To further increase the volumetric resolution beyond the Rayleigh diffraction limit, and achieve the quantum limit, we are also develo** dedicated protocols based on quantum Fisher information. However, for the quantum advantages of the proposed devices to be effective and appealing to end-users, two main challenges need to be tackled. First, due to the large number of frames required for correlation measurements to provide an acceptable SNR, quantum plenoptic imaging would require, if implemented with commercially available high-resolution cameras, acquisition times ranging from tens of seconds to a few minutes. Second, the elaboration of this large amount of data, in order to retrieve 3D images or refocusing 2D images, requires high-performance and time-consuming computation. To address these challenges, we are develo** high-resolution SPAD arrays and high-performance low-level programming of ultra-fast electronics, combined with compressive sensing and quantum tomography algorithms, with the aim to reduce both the acquisition and the elaboration time by two orders of magnitude. Routes toward exploitation of the QPI devices will also be discussed.
△ Less
Submitted 14 June, 2021;
originally announced June 2021.
-
Demonstration that Einstein-Podolsky-Rosen steering requires more than one bit of faster-than-light information transmission
Authors:
Yu Xiang,
Michael D. Mazurek,
Joshua C. Bienfang,
Michael A. Wayne,
Carlos Abellán,
Waldimar Amaya,
Morgan W. Mitchell,
Richard P. Mirin,
Sae Woo Nam,
Qiongyi He,
Martin J. Stevens,
Lynden K. Shalm,
Howard M. Wiseman
Abstract:
Schrödinger held that a local quantum system has some objectively real quantum state and no other (hidden) properties. He therefore took the Einstein-Podolsky-Rosen (EPR) phenomenon, which he generalized and called `steering', to require nonlocal wavefunction collapse. Because this would entail faster-than-light (FTL) information transmission, he doubted that it would be seen experimentally. Here…
▽ More
Schrödinger held that a local quantum system has some objectively real quantum state and no other (hidden) properties. He therefore took the Einstein-Podolsky-Rosen (EPR) phenomenon, which he generalized and called `steering', to require nonlocal wavefunction collapse. Because this would entail faster-than-light (FTL) information transmission, he doubted that it would be seen experimentally. Here we report a demonstration of EPR steering with entangled photon pairs that puts--in Schrödinger's interpretation--a non-zero lower bound on the amount of FTL information transmission. We develop a family of $n$-setting loss-tolerant EPR-steering inequalities allowing for a size-$d$ classical message sent from Alice's laboratory to Bob's. For the case $n=3$ and $d=2$ (one bit) we observe a statistically significant violation. Our experiment closes the efficiency and locality loopholes, and we address the freedom-of-choice loophole by using quantum random number generators to independently choose Alice's and Bob's measurement basis settings. To close the efficiency and locality loopholes simultaneously, we introduce methods for quickly switching between three mutually unbiased measurement bases and for accurately characterizing the efficiency of detectors. From the space-time arrangement of our experiment, we can conclude that if the mechanism for the observed bipartite correlations is that Alice's measurement induces wave-function collapse of Bob's particle, then more than one bit of information must travel from Alice to Bob at more than three times the speed of light.
△ Less
Submitted 9 August, 2021; v1 submitted 27 May, 2021;
originally announced May 2021.
-
Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector
Authors:
R. Abbott,
A. Abreu,
F. Addesa,
M. Alhusseini,
T. Anderson,
Y. Andreev,
A. Apresyan,
R. Arcidiacono,
M. Arenton,
E. Auffray,
D. Bastos,
L. A. T. Bauerdick,
R. Bellan,
M. Bellato,
A. Benaglia,
M. Benettoni,
R. Bertoni,
M. Besancon,
S. Bharthuar,
A. Bornheim,
E. Brücken,
J. N. Butler,
C. Campagnari,
M. Campana,
R. Carlin
, et al. (174 additional authors not shown)
Abstract:
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about…
▽ More
The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about 30 ps at the beginning of operation, and degrading to 50-60 ps at the end of the detector lifetime as a result of radiation damage. In this work, we present the results obtained using a 120 GeV proton beam at the Fermilab Test Beam Facility to measure the time resolution of unirradiated sensors. A proof-of-concept of the sensor layout proposed for the barrel region of the MTD, consisting of elongated crystal bars with dimensions of about 3 x 3 x 57 mm$^3$ and with double-ended SiPM readout, is demonstrated. This design provides a robust time measurement independent of the impact point of the MIP along the crystal bar. We tested LYSO:Ce bars of different thickness (2, 3, 4 mm) with a geometry close to the reference design and coupled to SiPMs manufactured by Hamamatsu and Fondazione Bruno Kessler. The various aspects influencing the timing performance such as the crystal thickness, properties of the SiPMs (e.g. photon detection efficiency), and impact angle of the MIP are studied. A time resolution of about 28 ps is measured for MIPs crossing a 3 mm thick crystal bar, corresponding to an MPV energy deposition of 2.6 MeV, and of 22 ps for the 4.2 MeV MPV energy deposition expected in the BTL, matching the detector performance target for unirradiated devices.
△ Less
Submitted 16 July, 2021; v1 submitted 15 April, 2021;
originally announced April 2021.
-
Construction and commissioning of CMS CE prototype silicon modules
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
M. Andrews,
P. Aspell,
I. A. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
P. Bargassa,
D. Barney,
E. Becheva,
P. Behera,
A. Belloni
, et al. (307 additional authors not shown)
Abstract:
As part of its HL-LHC upgrade program, the CMS Collaboration is develo** a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modul…
▽ More
As part of its HL-LHC upgrade program, the CMS Collaboration is develo** a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modules have been constructed with 6-inch hexagonal silicon sensors with cell areas of 1.1~$cm^2$, and the SKIROC2-CMS readout ASIC. Beam tests of different sampling configurations were conducted with the prototype modules at DESY and CERN in 2017 and 2018. This paper describes the construction and commissioning of the CE calorimeter prototype, the silicon modules used in the construction, their basic performance, and the methods used for their calibration.
△ Less
Submitted 10 December, 2020;
originally announced December 2020.
-
Comparison of $pp$ and $p \bar{p}$ differential elastic cross sections and observation of the exchange of a colorless $C$-odd gluonic compound
Authors:
V. M. Abazov,
B. Abbott,
B. S. Acharya,
M. Adams,
T. Adams,
J. P. Agnew,
G. D. Alexeev,
G. Alkhazov,
A. Alton,
G. A. Alves,
G. Antchev,
A. Askew,
P. Aspell,
A. C. S. Assis Jesus,
I. Atanassov,
S. Atkins,
K. Augsten,
V. Aushev,
Y. Aushev,
V. Avati,
C. Avila,
F. Badaud,
J. Baechler,
L. Bagby,
C. Baldenegro Barrera
, et al. (451 additional authors not shown)
Abstract:
We describe an analysis comparing the $p\bar{p}$ elastic cross section as measured by the D0 Collaboration at a center-of-mass energy of 1.96 TeV to that in $pp$ collisions as measured by the TOTEM Collaboration at 2.76, 7, 8, and 13 TeV using a model-independent approach. The TOTEM cross sections extrapolated to a center-of-mass energy of $\sqrt{s} =$ 1.96 TeV are compared with the D0 measurement…
▽ More
We describe an analysis comparing the $p\bar{p}$ elastic cross section as measured by the D0 Collaboration at a center-of-mass energy of 1.96 TeV to that in $pp$ collisions as measured by the TOTEM Collaboration at 2.76, 7, 8, and 13 TeV using a model-independent approach. The TOTEM cross sections extrapolated to a center-of-mass energy of $\sqrt{s} =$ 1.96 TeV are compared with the D0 measurement in the region of the diffractive minimum and the second maximum of the $pp$ cross section. The two data sets disagree at the 3.4$σ$ level and thus provide evidence for the $t$-channel exchange of a colorless, $C$-odd gluonic compound, also known as the odderon. We combine these results with a TOTEM analysis of the same $C$-odd exchange based on the total cross section and the ratio of the real to imaginary parts of the forward elastic scattering amplitude in $pp$ scattering. The combined significance of these results is larger than 5$σ$ and is interpreted as the first observation of the exchange of a colorless, $C$-odd gluonic compound.
△ Less
Submitted 25 June, 2021; v1 submitted 7 December, 2020;
originally announced December 2020.
-
The DAQ system of the 12,000 Channel CMS High Granularity Calorimeter Prototype
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
M. Andrews,
P. Aspell,
I. A. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
P. Bargassa,
D. Barney,
E. Becheva,
P. Behera,
A. Belloni
, et al. (307 additional authors not shown)
Abstract:
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endca…
▽ More
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ${\approx}12,000\rm{~channels}$ of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry PI computers.
△ Less
Submitted 8 December, 2020; v1 submitted 7 December, 2020;
originally announced December 2020.
-
A strong loophole-free test of local realism
Authors:
Lynden K. Shalm,
Evan Meyer-Scott,
Bradley G. Christensen,
Peter Bierhorst,
Michael A. Wayne,
Martin J. Stevens,
Thomas Gerrits,
Scott Glancy,
Deny R. Hamel,
Michael S. Allman,
Kevin J. Coakley,
Shellee D. Dyer,
Carson Hodge,
Adriana E. Lita,
Varun B. Verma,
Camilla Lambrocco,
Edward Tortorici,
Alan L. Migdall,
Yanbao Zhang,
Daniel R. Kumor,
William H. Farr,
Francesco Marsili,
Matthew D. Shaw,
Jeffrey A. Stern,
Carlos Abellán
, et al. (9 additional authors not shown)
Abstract:
We present a loophole-free violation of local realism using entangled photon pairs. We ensure that all relevant events in our Bell test are spacelike separated by placing the parties far enough apart and by using fast random number generators and high-speed polarization measurements. A high-quality polarization-entangled source of photons, combined with high-efficiency, low-noise, single-photon de…
▽ More
We present a loophole-free violation of local realism using entangled photon pairs. We ensure that all relevant events in our Bell test are spacelike separated by placing the parties far enough apart and by using fast random number generators and high-speed polarization measurements. A high-quality polarization-entangled source of photons, combined with high-efficiency, low-noise, single-photon detectors, allows us to make measurements without requiring any fair-sampling assumptions. Using a hypothesis test, we compute p-values as small as $5.9\times 10^{-9}$ for our Bell violation while maintaining the spacelike separation of our events. We estimate the degree to which a local realistic system could predict our measurement choices. Accounting for this predictability, our smallest adjusted p-value is $2.3 \times 10^{-7}$. We therefore reject the hypothesis that local realism governs our experiment.
△ Less
Submitted 6 September, 2016; v1 submitted 10 November, 2015;
originally announced November 2015.
-
Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data
Authors:
The CMS,
LHCb Collaborations,
:,
V. Khachatryan,
A. M. Sirunyan,
A. Tumasyan,
W. Adam,
T. Bergauer,
M. Dragicevic,
J. Erö,
M. Friedl,
R. Frühwirth,
V. M. Ghete,
C. Hartl,
N. Hörmann,
J. Hrubec,
M. Jeitler,
W. Kiesenhofer,
V. Knünz,
M. Krammer,
I. Krätschmer,
D. Liko,
I. Mikulec,
D. Rabady,
B. Rahbaran
, et al. (2807 additional authors not shown)
Abstract:
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta…
▽ More
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six standard deviations, and the best measurement of its branching fraction so far. Furthermore, evidence for the $B^0\toμ^+μ^-$ decay is obtained with a statistical significance of three standard deviations. The branching fraction measurements are statistically compatible with SM predictions and impose stringent constraints on several theories beyond the SM.
△ Less
Submitted 17 August, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.
-
Combination of CDF and D0 W-Boson Mass Measurements
Authors:
CDF Collaboration,
T. Aaltonen,
S. Amerio,
D. Amidei,
A. Anastassov,
A. Annovi,
J. Antos,
G. Apollinari,
J. A. Appel,
T. Arisawa,
A. Artikov,
J. Asaadi,
W. Ashmanskas,
B. Auerbach,
A. Aurisano,
F. Azfar,
W. Badgett,
T. Bae,
A. Barbaro-Galtieri,
V. E. Barnes,
B. A. Barnett,
P. Barria,
P. Bartos,
M. Bauce,
F. Bedeschi
, et al. (752 additional authors not shown)
Abstract:
We summarize and combine direct measurements of the mass of the $W$ boson in $\sqrt{s} = 1.96 \text{TeV}$ proton-antiproton collision data collected by CDF and D0 experiments at the Fermilab Tevatron Collider. Earlier measurements from CDF and D0 are combined with the two latest, more precise measurements: a CDF measurement in the electron and muon channels using data corresponding to…
▽ More
We summarize and combine direct measurements of the mass of the $W$ boson in $\sqrt{s} = 1.96 \text{TeV}$ proton-antiproton collision data collected by CDF and D0 experiments at the Fermilab Tevatron Collider. Earlier measurements from CDF and D0 are combined with the two latest, more precise measurements: a CDF measurement in the electron and muon channels using data corresponding to $2.2 \mathrm{fb}^{-1}$ of integrated luminosity, and a D0 measurement in the electron channel using data corresponding to $4.3 \mathrm{fb}^{-1}$ of integrated luminosity. The resulting Tevatron average for the mass of the $W$ boson is $\MW = 80\,387 \pm 16 \text{MeV}$. Including measurements obtained in electron-positron collisions at LEP yields the most precise value of $\MW = 80\,385 \pm 15 \text{MeV}$.
△ Less
Submitted 1 August, 2013; v1 submitted 29 July, 2013;
originally announced July 2013.
-
Combination of the top-quark mass measurements from the Tevatron collider
Authors:
The CDF,
D0 collaborations,
T. Aaltonen,
V. M. Abazov,
B. Abbott,
B. S. Acharya,
M. Adams,
T. Adams,
G. D. Alexeev,
G. Alkhazov,
A. Alton,
B. Alvarez Gonzalez,
G. Alverson,
S. Amerio,
D. Amidei,
A. Anastassov,
A. Annovi,
J. Antos,
G. Apollinari,
J. A. Appel,
T. Arisawa,
A. Artikov,
J. Asaadi,
W. Ashmanskas,
A. Askew
, et al. (840 additional authors not shown)
Abstract:
The top quark is the heaviest known elementary particle, with a mass about 40 times larger than the mass of its isospin partner, the bottom quark. It decays almost 100% of the time to a $W$ boson and a bottom quark. Using top-antitop pairs at the Tevatron proton-antiproton collider, the CDF and {\dzero} collaborations have measured the top quark's mass in different final states for integrated lumi…
▽ More
The top quark is the heaviest known elementary particle, with a mass about 40 times larger than the mass of its isospin partner, the bottom quark. It decays almost 100% of the time to a $W$ boson and a bottom quark. Using top-antitop pairs at the Tevatron proton-antiproton collider, the CDF and {\dzero} collaborations have measured the top quark's mass in different final states for integrated luminosities of up to 5.8 fb$^{-1}$. This paper reports on a combination of these measurements that results in a more precise value of the mass than any individual decay channel can provide. It describes the treatment of the systematic uncertainties and their correlations. The mass value determined is $173.18 \pm 0.56 \thinspace ({\rm stat}) \pm 0.75 \thinspace ({\rm syst})$ GeV or $173.18 \pm 0.94$ GeV, which has a precision of $\pm 0.54%$, making this the most precise determination of the top quark mass.
△ Less
Submitted 16 November, 2012; v1 submitted 4 July, 2012;
originally announced July 2012.
-
Measurement of the differential cross section dσ/dt in elastic $p\bar{p}$ scattering at sqrt(s)=1.96 TeV
Authors:
D0 Collaboration,
V. M. Abazov,
B. Abbott,
B. S. Acharya,
M. Adams,
T. Adams,
G. D. Alexeev,
G. Alkhazov,
A. Alton,
G. Alverson,
G. A. Alves,
M. Aoki,
A. Askew,
S. Atkins,
K. Augsten,
C. Avila,
F. Badaud,
L. Bagby,
B. Baldin,
D. V. Bandurin,
S. Banerjee,
E. Barberis,
P. Baringer,
J. Barreto,
J. F. Bartlett
, et al. (384 additional authors not shown)
Abstract:
We present a measurement of the elastic differential cross section $dσ(p\bar{p}\rightarrow p\bar{p})/dt$ as a function of the four-momentum-transfer squared t. The data sample corresponds to an integrated luminosity of $\approx 31 nb^{-1}$ collected with the D0 detector using dedicated Tevatron $p\bar{p} $ Collider operating conditions at sqrt(s) = 1.96 TeV and covers the range…
▽ More
We present a measurement of the elastic differential cross section $dσ(p\bar{p}\rightarrow p\bar{p})/dt$ as a function of the four-momentum-transfer squared t. The data sample corresponds to an integrated luminosity of $\approx 31 nb^{-1}$ collected with the D0 detector using dedicated Tevatron $p\bar{p} $ Collider operating conditions at sqrt(s) = 1.96 TeV and covers the range $0.26 <|t|< 1.2 GeV^2$. For $|t|<0.6 GeV^2$, dσ/dt is described by an exponential function of the form $Ae^{-b|t|}$ with a slope parameter $ b = 16.86 \pm 0.10(stat) \pm 0.20(syst) GeV^{-2}$. A change in slope is observed at $|t| \approx 0.6 GeV^2$, followed by a more gradual |t| dependence with increasing values of |t|.
△ Less
Submitted 4 June, 2012;
originally announced June 2012.
-
Combination of CDF and D0 measurements of the W boson helicity in top quark decays
Authors:
The CDF,
D0 Collaborations,
:,
T. Aaltonen,
V. M. Abazov,
B. Abbott,
B. S. Acharya,
M. Adams,
T. Adams,
G. D. Alexeev,
G. Alkhazov,
A. Alton,
B. Álvarez González,
G. Alverson,
S. Amerio,
D. Amidei,
A. Anastassov,
A. Annovi,
J. Antos,
M. Aoki,
G. Apollinari,
J. A. Appel,
T. Arisawa,
A. Artikov,
J. Asaadi
, et al. (846 additional authors not shown)
Abstract:
We report the combination of recent measurements of the helicity of the W boson from top quark decay by the CDF and D0 collaborations, based on data samples corresponding to integrated luminosities of 2.7 - 5.4 fb^-1 of ppbar collisions collected during Run II of the Fermilab Tevatron Collider. Combining measurements that simultaneously determine the fractions of W bosons with longitudinal (f0) an…
▽ More
We report the combination of recent measurements of the helicity of the W boson from top quark decay by the CDF and D0 collaborations, based on data samples corresponding to integrated luminosities of 2.7 - 5.4 fb^-1 of ppbar collisions collected during Run II of the Fermilab Tevatron Collider. Combining measurements that simultaneously determine the fractions of W bosons with longitudinal (f0) and right-handed (f+) helicities, we find f0 = 0.722 \pm 0.081 [\pm 0.062 (stat.) \pm 0.052 (syst.)] and f+ = -0.033 \pm 0.046 [\pm 0.034 (stat.) \pm 0.031 (syst.)]. Combining measurements where one of the helicity fractions is fixed to the value expected in the standard model, we find f0 = 0.682 \pm 0.057 [\pm 0.035 (stat.) \pm 0.046 (syst.)] and f+ = -0.015\pm0.035 [\pm 0.018 (stat.) \pm 0.030 (syst.)]. The results are consistent with standard model expectations.
△ Less
Submitted 23 February, 2012;
originally announced February 2012.
-
Search for pair production of the scalar top quark in muon+tau final states
Authors:
D0 Collaboration,
V. M. Abazov,
B. Abbott,
B. S. Acharya,
M. Adams,
T. Adams,
G. D. Alexeev,
G. Alkhazov,
A. Alton,
G. Alverson,
M. Aoki,
A. Askew,
B. Asman,
S. Atkins,
O. Atramentov,
K. Augsten,
C. Avila,
J. BackusMayes,
F. Badaud,
L. Bagby,
B. Baldin,
D. V. Bandurin,
S. Banerjee,
E. Barberis,
P. Baringer
, et al. (385 additional authors not shown)
Abstract:
We present a search for the pair production of scalar top quarks ($\tilde{t}_{1}$), the lightest supersymmetric partners of the top quarks, in $p\bar{p}$ collisions at a center-of-mass energy of 1.96 TeV, using data corresponding to an integrated luminosity of {7.3 $fb^{-1}$} collected with the \dzero experiment at the Fermilab Tevatron Collider. Each scalar top quark is assumed to decay into a…
▽ More
We present a search for the pair production of scalar top quarks ($\tilde{t}_{1}$), the lightest supersymmetric partners of the top quarks, in $p\bar{p}$ collisions at a center-of-mass energy of 1.96 TeV, using data corresponding to an integrated luminosity of {7.3 $fb^{-1}$} collected with the \dzero experiment at the Fermilab Tevatron Collider. Each scalar top quark is assumed to decay into a $b$ quark, a charged lepton, and a scalar neutrino ($\tildeν$). We investigate final states arising from $\tilde{t}_{1} \bar{\tilde{t}_{1}} \rightarrow b\bar{b}μτ\tildeν \tildeν$ and $\tilde{t}_{1} \bar{\tilde{t}_{1}} \rightarrow b\bar{b}ττ\tildeν \tildeν$. With no significant excess of events observed above the background expected from the standard model, we set exclusion limits on this production process in the ($m_{\tilde{t}_{1}}$,$m_{\tildeν}$) plane.
△ Less
Submitted 9 February, 2012;
originally announced February 2012.
-
Precise measurement of the top quark mass in the dilepton channel at D0
Authors:
D0 Collaboration,
V. M. Abazov,
B. Abbott,
B. S. Acharya,
M. Adams,
T. Adams,
G. D. Alexeev,
G. Alkhazov,
A. Alton,
G. Alverson,
G. A. Alves,
L. S. Ancu,
M. Aoki,
M. Arov,
A. Askew,
B. Åsman,
O. Atramentov,
C. Avila,
J. BackusMayes,
F. Badaud,
L. Bagby,
B. Baldin,
D. V. Bandurin,
S. Banerjee,
E. Barberis
, et al. (397 additional authors not shown)
Abstract:
We measure the top quark mass (mt) in ppbar collisions at a center of mass energy of 1.96 TeV using dilepton ttbar->W+bW-bbar->l+nubl-nubarbbar events, where l denotes an electron, a muon, or a tau that decays leptonically. The data correspond to an integrated luminosity of 5.4 fb-1 collected with the D0 detector at the Fermilab Tevatron Collider. We obtain mt = 174.0 +- 1.8(stat) +- 2.4(syst) GeV…
▽ More
We measure the top quark mass (mt) in ppbar collisions at a center of mass energy of 1.96 TeV using dilepton ttbar->W+bW-bbar->l+nubl-nubarbbar events, where l denotes an electron, a muon, or a tau that decays leptonically. The data correspond to an integrated luminosity of 5.4 fb-1 collected with the D0 detector at the Fermilab Tevatron Collider. We obtain mt = 174.0 +- 1.8(stat) +- 2.4(syst) GeV, which is in agreement with the current world average mt = 173.3 +- 1.1 GeV. This is currently the most precise measurement of mt in the dilepton channel.
△ Less
Submitted 28 August, 2011; v1 submitted 2 May, 2011;
originally announced May 2011.
-
Measurement of the W boson helicity in top quark decays using 5.4 fb^-1 of ppbar collision data
Authors:
V. M. Abazov,
B. Abbott,
B. S. Acharya,
M. Adams,
T. Adams,
G. D. Alexeev,
G. Alkhazov,
A. Altona,
G. Alverson,
G. A. Alves,
L. S. Ancu,
M. Aoki,
Y. Arnoud,
M. Arov,
A. Askew,
B. Asman,
O. Atramentov,
C. Avila,
J. BackusMayes,
F. Badaud,
L. Bagby,
B. Baldin,
D. V. Bandurin,
S. Banerjee,
E. Barberis
, et al. (403 additional authors not shown)
Abstract:
We present a measurement of the helicity of the W boson produced in top quark decays using ttbar decays in the l+jets and dilepton final states selected from a sample of 5.4 fb^-1 of collisions recorded using the D0 detector at the Fermilab Tevatron ppbar collider. We measure the fractions of longitudinal and right-handed W bosons to be f_0 = 0.669 +- 0.102 [ +- 0.078 (stat.) +- 0.065 (syst.)] and…
▽ More
We present a measurement of the helicity of the W boson produced in top quark decays using ttbar decays in the l+jets and dilepton final states selected from a sample of 5.4 fb^-1 of collisions recorded using the D0 detector at the Fermilab Tevatron ppbar collider. We measure the fractions of longitudinal and right-handed W bosons to be f_0 = 0.669 +- 0.102 [ +- 0.078 (stat.) +- 0.065 (syst.)] and f_+ = 0.023 +- 0.053 [+- 0.041 (stat.) +- 0.034 (syst.)], respectively. This result is consistent at the 98% level with the standard model. A measurement with f_0 fixed to the value from the standard model yields f_+ = 0.010 +- 0.037 [+- 0.022 (stat.) +- 0.030 (syst.) ].
△ Less
Submitted 20 September, 2012; v1 submitted 30 November, 2010;
originally announced November 2010.
-
Search for pair production of the scalar top quark in the electron-muon final state
Authors:
V. M. Abazov,
B. Abbott,
M. Abolins,
B. S. Acharya,
M. Adams,
T. Adams,
G. D. Alexeev,
G. Alkhazov,
A. Altona,
G. Alverson,
G. A. Alves,
L. S. Ancu,
M. Aoki,
Y. Arnoud,
M. Arov,
A. Askew,
B. Åsman,
O. Atramentov,
C. Avila,
J. BackusMayes,
F. Badaud,
L. Bagby,
B. Baldin,
D. V. Bandurin,
S. Banerjee
, et al. (406 additional authors not shown)
Abstract:
We report the result of a search for the pair production of the lightest supersymmetric partner of the top quark ($\tilde{t}_1$) in $p\bar{p}$ collisions at a center-of-mass energy of 1.96 TeV at the Fermilab Tevatron collider corresponding to an integrated luminosity of 5.4 fb$^{-1}$. The scalar top quarks are assumed to decay into a $b$ quark, a charged lepton, and a scalar neutrino (…
▽ More
We report the result of a search for the pair production of the lightest supersymmetric partner of the top quark ($\tilde{t}_1$) in $p\bar{p}$ collisions at a center-of-mass energy of 1.96 TeV at the Fermilab Tevatron collider corresponding to an integrated luminosity of 5.4 fb$^{-1}$. The scalar top quarks are assumed to decay into a $b$ quark, a charged lepton, and a scalar neutrino ($\tildeν$), and the search is performed in the electron plus muon final state. No significant excess of events above the standard model prediction is detected, and improved exclusion limits at the 95% C.L. are set in the the ($M_{\tilde{t}_1}$,$M_{\tildeν}$) mass plane.
△ Less
Submitted 29 September, 2010;
originally announced September 2010.
-
Determination of the width of the top quark
Authors:
V. M. Abazov,
B. Abbott,
M. Abolins,
B. S. Acharya,
M. Adams,
T. Adams,
G. D. Alexeev,
G. Alkhazov,
A. Altona,
G. Alverson,
G. A. Alves,
L. S. Ancu,
M. Aoki,
Y. Arnoud,
M. Arov,
A. Askew,
B. Åsman,
O. Atramentov,
C. Avila,
J. BackusMayes,
F. Badaud,
L. Bagby,
B. Baldin,
D. V. Bandurin,
S. Banerjee
, et al. (406 additional authors not shown)
Abstract:
We extract the total width of the top quark, Gamma_t, from the partial decay width Gamma(t -> W b) measured using the t-channel cross section for single top quark production and from the branching fraction B(t -> W b) measured in ttbar events using up to 2.3 fb^-1 of integrated luminosity collected by the D0 Collaboration at the Tevatron ppbar Collider. The result is Gamma_t = 1.99 +0.69 -0.55 GeV…
▽ More
We extract the total width of the top quark, Gamma_t, from the partial decay width Gamma(t -> W b) measured using the t-channel cross section for single top quark production and from the branching fraction B(t -> W b) measured in ttbar events using up to 2.3 fb^-1 of integrated luminosity collected by the D0 Collaboration at the Tevatron ppbar Collider. The result is Gamma_t = 1.99 +0.69 -0.55 GeV, which translates to a top-quark lifetime of tau_t = (3.3 +1.3 -0.9) x 10^-25 s. Assuming a high mass fourth generation b' quark and unitarity of the four-generation quark-mixing matrix, we set the first upper limit on |Vtb'| < 0.63 at 95% C.L.
△ Less
Submitted 28 September, 2010;
originally announced September 2010.