Skip to main content

Showing 1–3 of 3 results for author: Wasser, A

.
  1. Highly charged ion X-rays from Electron-Cyclotron Resonance Ion Sources

    Authors: Paul Indelicato, S. Boucard, D. S. Covita, D. Gotta, A. Gruber, A. Hirtl, H. Fuhrmann, E. -O. Le Bigot, S. Schlesser, J. M. F. Dos Santos, L. M. Simons, L. Stingelin, M. Trassinelli, J. Veloso, A. Wasser, J. Zmeskal

    Abstract: Radiation from the highly-charged ions contained in the plasma of Electron-Cyclotron Resonance Ion Sources constitutes a very bright source of X-rays. Because the ions have a relatively low kinetic energy ($\approx 1$ eV) transitions can be very narrow, containing only small Doppler broadening. We describe preliminary accurate measurements of two and three-electron ions with Z=16--18. We show ho… ▽ More

    Submitted 28 October, 2006; originally announced October 2006.

  2. arXiv:physics/0410250  [pdf, ps, other

    physics.atom-ph

    High Resolution He-like Argon And Sulfur Spectra From The PSI ECRIT

    Authors: Martino Trassinelli, Sandor Biri, Stephane Boucard, Daniel S. Covita, Detlev Gotta, Bruno Leoni, Albert Hirtl, Paul Indelicato, Eric-Olivier Le Bigot, Joaquim M. F. Dos Santos, Leopold M. Simons, Lucas Stingelin, Joao F. C. A. Veloso, Alfred Wasser, Johann Zmeskal

    Abstract: We present new results on the X-ray spectroscopy of multicharged argon, sulfur and chlorine obtained with the Electron Cyclotron Resonance Ion Trap (ECRIT) in operation at the Paul Scherrer Institut (Villigen, Switzerland). We used a Johann-type Bragg spectrometer with a spherically-bent crystal, with an energy resolution of about 0.4 eV. The ECRIT itself is of a hybrid type, with a superconduct… ▽ More

    Submitted 26 October, 2004; originally announced October 2004.

    Journal ref: ECR Ion Sources 2004, Etats-Unis d'Amerique (2004)

  3. On the characterisation of a Bragg spectrometer with X-rays from an ECR source

    Authors: D. F. Anagnostopoulos, S. Biri, D. Gotta, A. Gruber, Paul Indelicato, B. Leoni, H. Fuhrmann, L. M. Simons, L. Stingelin, A. Wasser, J. Zmeskal

    Abstract: Narrow X-ray lines from helium-like argon emitted from a dedicated ECR source have been used to determine the response function of a Bragg crystal spectrometer equipped with large area spherically bent silicon (111) or quartz (10$\bar{1}$) crystals. The measured spectra are compared with simulated ones created by a ray-tracing code based on the expected theoretical crystal's rocking curve and th… ▽ More

    Submitted 23 December, 2004; v1 submitted 18 August, 2004; originally announced August 2004.

    Comments: Version acceptee (NIM)

    Journal ref: Nuclear Instruments and Methods in Physics Research A 545 (2005) 217