-
Highly charged ion X-rays from Electron-Cyclotron Resonance Ion Sources
Authors:
Paul Indelicato,
S. Boucard,
D. S. Covita,
D. Gotta,
A. Gruber,
A. Hirtl,
H. Fuhrmann,
E. -O. Le Bigot,
S. Schlesser,
J. M. F. Dos Santos,
L. M. Simons,
L. Stingelin,
M. Trassinelli,
J. Veloso,
A. Wasser,
J. Zmeskal
Abstract:
Radiation from the highly-charged ions contained in the plasma of Electron-Cyclotron Resonance Ion Sources constitutes a very bright source of X-rays. Because the ions have a relatively low kinetic energy ($\approx 1$ eV) transitions can be very narrow, containing only small Doppler broadening. We describe preliminary accurate measurements of two and three-electron ions with Z=16--18. We show ho…
▽ More
Radiation from the highly-charged ions contained in the plasma of Electron-Cyclotron Resonance Ion Sources constitutes a very bright source of X-rays. Because the ions have a relatively low kinetic energy ($\approx 1$ eV) transitions can be very narrow, containing only small Doppler broadening. We describe preliminary accurate measurements of two and three-electron ions with Z=16--18. We show how these measurement can test sensitively many-body relativistic calculations or can be used as X-ray standards for precise measurements of X-ray transitions in exotic atoms.
△ Less
Submitted 28 October, 2006;
originally announced October 2006.
-
High Resolution He-like Argon And Sulfur Spectra From The PSI ECRIT
Authors:
Martino Trassinelli,
Sandor Biri,
Stephane Boucard,
Daniel S. Covita,
Detlev Gotta,
Bruno Leoni,
Albert Hirtl,
Paul Indelicato,
Eric-Olivier Le Bigot,
Joaquim M. F. Dos Santos,
Leopold M. Simons,
Lucas Stingelin,
Joao F. C. A. Veloso,
Alfred Wasser,
Johann Zmeskal
Abstract:
We present new results on the X-ray spectroscopy of multicharged argon, sulfur and chlorine obtained with the Electron Cyclotron Resonance Ion Trap (ECRIT) in operation at the Paul Scherrer Institut (Villigen, Switzerland). We used a Johann-type Bragg spectrometer with a spherically-bent crystal, with an energy resolution of about 0.4 eV. The ECRIT itself is of a hybrid type, with a superconduct…
▽ More
We present new results on the X-ray spectroscopy of multicharged argon, sulfur and chlorine obtained with the Electron Cyclotron Resonance Ion Trap (ECRIT) in operation at the Paul Scherrer Institut (Villigen, Switzerland). We used a Johann-type Bragg spectrometer with a spherically-bent crystal, with an energy resolution of about 0.4 eV. The ECRIT itself is of a hybrid type, with a superconducting split coil magnet, special iron inserts which provides the mirror field, and a permanent magnetic hexapole. The high frequency was provided by a 6.4 GHz microwave emitter. We obtained high intensity X-ray spectra of multicharged F-like to He-like argon, sulfur and chlorine with one 1s hole. In particular, we observed the $1s2s^{3}S_1 \to 1s^2^{1}S_0 M1$ and $1s2p^{3}P_2 \to 1s^2^{1}S_0 M2$ transitions in He-like argon, sulfur and chlorine with unprecedented statistics and resolution. The energies of the observed lines are being determined with good accuracy using the He-like M1 line as a reference.
△ Less
Submitted 26 October, 2004;
originally announced October 2004.
-
On the characterisation of a Bragg spectrometer with X-rays from an ECR source
Authors:
D. F. Anagnostopoulos,
S. Biri,
D. Gotta,
A. Gruber,
Paul Indelicato,
B. Leoni,
H. Fuhrmann,
L. M. Simons,
L. Stingelin,
A. Wasser,
J. Zmeskal
Abstract:
Narrow X-ray lines from helium-like argon emitted from a dedicated ECR source have been used to determine the response function of a Bragg crystal spectrometer equipped with large area spherically bent silicon (111) or quartz (10$\bar{1}$) crystals. The measured spectra are compared with simulated ones created by a ray-tracing code based on the expected theoretical crystal's rocking curve and th…
▽ More
Narrow X-ray lines from helium-like argon emitted from a dedicated ECR source have been used to determine the response function of a Bragg crystal spectrometer equipped with large area spherically bent silicon (111) or quartz (10$\bar{1}$) crystals. The measured spectra are compared with simulated ones created by a ray-tracing code based on the expected theoretical crystal's rocking curve and the geometry of the experimental set-up.
△ Less
Submitted 23 December, 2004; v1 submitted 18 August, 2004;
originally announced August 2004.