The PANDA Barrel DIRC
Authors:
R. Dzhygadlo,
A. Belias,
A. Gerhardt,
D. Lehmann,
K. Peters,
G. Schepers,
C. Schwarz,
J. Schwiening,
M. Traxler,
Y. Wolf,
L. Schmitt,
M. Böhm,
K. Gumbert,
S. Krauss,
A. Lehmann,
D. Miehling,
M. Düren,
A. Hayrapetyan,
I. Köseoglu,
M. Schmidt,
T. Wasem,
C. Sfienti,
A. Ali
Abstract:
The PANDA experiment at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR), Darmstadt, Germany, will address fundamental questions of hadron physics using $\bar{p}p$ annihilations. Excellent Particle Identification (PID) over a large range of solid angles and particle momenta will be essential to meet the objectives of the rich physics program. Charged PID in t…
▽ More
The PANDA experiment at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR), Darmstadt, Germany, will address fundamental questions of hadron physics using $\bar{p}p$ annihilations. Excellent Particle Identification (PID) over a large range of solid angles and particle momenta will be essential to meet the objectives of the rich physics program. Charged PID in the target region will be provided by a Barrel DIRC (Detection of Internally Reflected Cherenkov light) counter. The Barrel DIRC, covering the polar angle range of 22-140 degrees, will provide a $π/K$ separation power of at least 3 standard deviations for charged particle momenta up to 3.5 GeV/c. The design of the Barrel DIRC features narrow radiator bars made from synthetic fused silica, an innovative multi-layer spherical lens focusing system, a prism-shaped synthetic fused silica expansion volume, and an array of lifetime-enhanced Microchannel Plate PMTs (MCP-PMTs) to detect the hit location and arrival time of the Cherenkov photons. Detailed Monte-Carlo simulations were performed, and reconstruction methods were developed to study the performance of the system. All critical aspects of the design and the performance were validated with system prototypes in a mixed hadron beam at the CERN PS. In 2020 the PANDA Barrel DIRC project advanced from the design stage to component fabrication. The series production of the fused silica bars was successfully completed in 2021 and delivery of the MCP-PMTs started in May 2022.
△ Less
Submitted 12 January, 2024;
originally announced January 2024.
-
Performance of the most recent Microchannel-Plate PMTs for the PANDA DIRC detectors at FAIR
Authors:
S. Krauss,
M. Böhm,
K. Gumbert,
A. Lehmann,
D. Miehling,
A. Belias,
R. Dzhygadlo,
A. Gerhardt,
D. Lehmann,
K. Peters,
G. Schepers,
C. Schwarz,
J. Schwiening,
M. Traxler,
Y. Wolf,
L. Schmitt,
M. Düren,
A. Hayrapetyan,
I. Köseoglu,
M. Schmidt,
T. Wasem,
C. Sfienti,
A. Ali
Abstract:
In the PANDA experiment at the FAIR facility at GSI two DIRC (Detection of Internally Reflected Cherenkov light) detectors will be used for $π$/K separation up to 4 GeV/c. Due to their location in a high magnetic field and other stringent requirements like high detection efficiency, low dark count rate, radiation hardness, long lifetime and good timing, MCP-PMTs (microchannel-plate photomultiplier…
▽ More
In the PANDA experiment at the FAIR facility at GSI two DIRC (Detection of Internally Reflected Cherenkov light) detectors will be used for $π$/K separation up to 4 GeV/c. Due to their location in a high magnetic field and other stringent requirements like high detection efficiency, low dark count rate, radiation hardness, long lifetime and good timing, MCP-PMTs (microchannel-plate photomultiplier) were the best choice of photon sensors for the DIRC detectors in the PANDA experiment. This paper will present the performance of some of the latest 2$\times$2 inch$^2$ MCP-PMTs from Photek and Photonis, including the first mass production tubes for the PANDA Barrel DIRC from Photonis. Performance parameters like the collection efficiency (CE), quantum efficiency (QE), and gain homogeneity were determined. The effect of magnetic fields on some properties like gain and charge cloud width was investigated as well. Apart from that the spatial distribution of many internal parameters like time resolution, dark count rate, afterpulse ratio, charge sharing crosstalk and recoil electrons were measured simultaneously with a multihit capable DAQ system. The latest generation of Photonis MCP-PMTs shows an unexpected "escalation" effect where the MCP-PMT itself produces photons.
△ Less
Submitted 28 November, 2023;
originally announced November 2023.
-
Lifetime and performance of the very latest microchannel-plate photomultipliers
Authors:
D. Miehling,
M. Böhm,
K. Gumbert,
S. Krauss,
A. Lehmann,
A. Belias,
R. Dzhygadlo,
A. Gerhardt,
D. Lehmann,
K. Peters,
G. Schepers,
C. Schwarz,
J. Schwiening,
M. Traxler,
Y. Wolf,
L. Schmitt,
M. Düren,
A. Hayrapetyan,
I. Köseoglu,
M. Schmidt,
T. Wasem,
C. Sfienti,
A. Ali
Abstract:
The PANDA experiment at the FAIR facility at GSI will study hadron physics using a high intensity antiproton beam of up to 15 GeV/c momentum to perform high precision spectroscopy. Two DIRC detectors with their image planes residing in an $\sim$1 T magnetic field will be used in the experiment. The only suitable photon detectors for both DIRCs were identified to be Microchannel-Plate Photomultipli…
▽ More
The PANDA experiment at the FAIR facility at GSI will study hadron physics using a high intensity antiproton beam of up to 15 GeV/c momentum to perform high precision spectroscopy. Two DIRC detectors with their image planes residing in an $\sim$1 T magnetic field will be used in the experiment. The only suitable photon detectors for both DIRCs were identified to be Microchannel-Plate Photomultipliers (MCP-PMTs). Since the aging problems of MCP-PMTs were solved recently by coating the MCPs with the so-called ALD-technique (atomic layer deposition) we are investigating devices which are significantly improved with respect to other parameters, as, e.g., the collection efficiency (CE) and the quantum efficiency (QE). The latest generation of MCP-PMTs can reach a detective quantum efficiency DQE = QE - CE of 30%. This paper will present the performance of the most advanced 53 $\times$ 53 mm$^2$ ALD-coated MCP-PMTs from Photonis (8 $\times$ 8 and 3 $\times$ 100 anodes) and Photek (8 $\times$ 8 anodes), also inside the magnetic field. With a picosecond laser and a multi-hit capable DAQ system which allows read out up to 300 pixels simultaneously, parameters like darkcount rate, afterpulse probability and time resolution can be investigated as a function of incident photon position.
△ Less
Submitted 28 November, 2023;
originally announced November 2023.
-
PANDA Barrel DIRC: From Design to Component Production
Authors:
G Schepers,
A Belias,
R Dzhygadlo,
A Gerhardt,
D Lehmann,
K Peters,
C Schwarz,
J Schwiening,
M Traxler,
L Schmitt,
M Böhm,
S Krauss,
A Lehmann,
D Miehling,
M Pfaffinger,
M Düren,
E Etzelmüller,
K Föhl,
A Hayrapetyan,
I Köseoglu,
M Schmidt,
T Wasem,
C Sfienti,
A Ali,
A Barnyakov
, et al. (3 additional authors not shown)
Abstract:
Excellent particle identification (PID) will be essential for the PANDA experiment at FAIR. The Barrel DIRC will separate kaons and pions with at least 3 s.d. for momenta up to 3.5 GeV/c and polar angles between 22 and 140 deg. After successful validation of the final design in the CERN PS/T9 beam line, the tendering process for the two most time- and cost-intensive items, radiator bars and MCP-PM…
▽ More
Excellent particle identification (PID) will be essential for the PANDA experiment at FAIR. The Barrel DIRC will separate kaons and pions with at least 3 s.d. for momenta up to 3.5 GeV/c and polar angles between 22 and 140 deg. After successful validation of the final design in the CERN PS/T9 beam line, the tendering process for the two most time- and cost-intensive items, radiator bars and MCP-PMTs, started in 2018. In Sep. 2019 Nikon was selected to build the fused silica bars and successfully completed the series production of 112 bars in Feb. 2021. Measurements of the mechanical quality of the bars were performed by Nikon and the optical quality was evaluated at GSI. In Dec. 2020, the contract for the fabrication of the MCP-PMTs was awarded to PHOTONIS and the delivery of the first-of-series MCP-PMTs is expected in July 2021. We present the design of the PANDA Barrel DIRC as well as the status of the component series production and the result of the quality assurance measurements.
△ Less
Submitted 26 January, 2022;
originally announced January 2022.
-
PANDA Phase One
Authors:
G. Barucca,
F. Davì,
G. Lancioni,
P. Mengucci,
L. Montalto,
P. P. Natali,
N. Paone,
D. Rinaldi,
L. Scalise,
B. Krusche,
M. Steinacher,
Z. Liu,
C. Liu,
B. Liu,
X. Shen,
S. Sun,
G. Zhao,
J. Zhao,
M. Albrecht,
W. Alkakhi,
S. Bökelmann,
S. Coen,
F. Feldbauer,
M. Fink,
J. Frech
, et al. (399 additional authors not shown)
Abstract:
The Facility for Antiproton and Ion Research (FAIR) in Darmstadt, Germany, provides unique possibilities for a new generation of hadron-, nuclear- and atomic physics experiments. The future antiProton ANnihilations at DArmstadt (PANDA or $\overline{\rm P}$ANDA) experiment at FAIR will offer a broad physics programme, covering different aspects of the strong interaction. Understanding the latter in…
▽ More
The Facility for Antiproton and Ion Research (FAIR) in Darmstadt, Germany, provides unique possibilities for a new generation of hadron-, nuclear- and atomic physics experiments. The future antiProton ANnihilations at DArmstadt (PANDA or $\overline{\rm P}$ANDA) experiment at FAIR will offer a broad physics programme, covering different aspects of the strong interaction. Understanding the latter in the non-perturbative regime remains one of the greatest challenges in contemporary physics. The antiproton-nucleon interaction studied with PANDA provides crucial tests in this area. Furthermore, the high-intensity, low-energy domain of PANDA allows for searches for physics beyond the Standard Model, e.g. through high precision symmetry tests. This paper takes into account a staged approach for the detector setup and for the delivered luminosity from the accelerator. The available detector setup at the time of the delivery of the first antiproton beams in the HESR storage ring is referred to as the \textit{Phase One} setup. The physics programme that is achievable during Phase One is outlined in this paper.
△ Less
Submitted 9 June, 2021; v1 submitted 28 January, 2021;
originally announced January 2021.
-
The PANDA DIRCs
Authors:
C. Schwarz,
A. Ali,
A. Belias,
R. Dzhygadlo,
A. Gerhardt,
M. Krebs,
D. Lehmann,
K. Peters,
G. Schepers,
J. Schwiening,
M. Traxler,
L. Schmitt,
M. Böhm,
A. Lehmann,
M. Pfaffinger,
S. Stelter,
M. Düren,
E. Etzelmüller,
K. Föhl,
A. Hayrapetyan,
I. Köseoglu,
K. Kreutzfeld,
M. Schmidt,
T. Wasem,
C. Sfienti
, et al. (6 additional authors not shown)
Abstract:
The PANDA experiment at the FAIR facility adresses open questions in hadron physics with antiproton beams in the momentum range of 1.5-15 GeV/c. The antiprotons are stored and cooled in a High Energy Storage RING (HESR) with a momentum spread down to Dp/p = 4*10^-5. A high luminosity of up to 2*10^32 cm-2 s-1 can be achieved. An excellent hadronic particle identification (PID) will be provided by…
▽ More
The PANDA experiment at the FAIR facility adresses open questions in hadron physics with antiproton beams in the momentum range of 1.5-15 GeV/c. The antiprotons are stored and cooled in a High Energy Storage RING (HESR) with a momentum spread down to Dp/p = 4*10^-5. A high luminosity of up to 2*10^32 cm-2 s-1 can be achieved. An excellent hadronic particle identification (PID) will be provided by two Cherenkov detectors using the priciple of Detection of Internally Reflected Cherenkov light (DIRC). In the forward direction from polar angles of 5 degree to 22 degree, the Endcap Disc DIRC (EDD) separates pions from kaons up to momenta of 4 GeV/c. Between 22 degree and 140 degree the Barrel DIRC cleanly separates pions from kaons for momenta up to 3.5 GeV/c. This article describes the design of the Barrel DIRC and of the Endcap Disc DIRC and the validation of their designs in particle beams at the CERN PS.
△ Less
Submitted 26 January, 2021;
originally announced January 2021.
-
Time imaging reconstruction for the PANDA Barrel DIRC
Authors:
R. Dzhygadlo,
A. Ali,
A. Belias,
A. Gerhardt,
M. Krebs,
D. Lehmann,
K. Peters,
G. Schepers,
C. Schwarz,
J. Schwiening,
M. Traxler,
L. Schmitt,
M. Böhm,
A. Lehmann,
M. Pfaffinger,
S. Stelter,
F. Uhlig,
M. Düren,
E. Etzelmüller,
K. Föhl,
A. Hayrapetyan,
I. Köseoglu,
K. Kreutzfeld,
J. Rieke,
M. Schmidt
, et al. (2 additional authors not shown)
Abstract:
The innovative Barrel DIRC (Detection of Internally Reflected Cherenkov light) counter will provide hadronic particle identification (PID) in the central region of the PANDA experiment at the new Facility for Antiproton and Ion Research (FAIR), Darmstadt, Germany. This detector is designed to separate charged pions and kaons with at least 3 standard deviations for momenta up to 3.5 GeV/c, covering…
▽ More
The innovative Barrel DIRC (Detection of Internally Reflected Cherenkov light) counter will provide hadronic particle identification (PID) in the central region of the PANDA experiment at the new Facility for Antiproton and Ion Research (FAIR), Darmstadt, Germany. This detector is designed to separate charged pions and kaons with at least 3 standard deviations for momenta up to 3.5 GeV/c, covering the polar angle range of 22$^{\circ}$-140$^{\circ}$. An array of microchannel plate photomultiplier tubes is used to detect the location and arrival time of the Cherenkov photons with a position resolution of 2 mm and time precision of about 100 ps. The time imaging reconstruction has been developed to make optimum use of the observables and to determine the performance of the detector. This reconstruction algorithm performs particle identification by directly calculating the maximum likelihoods using probability density functions based on detected photon propagation time in each pixel, determined directly from the data, or analytically, or from detailed simulations.
△ Less
Submitted 21 September, 2020;
originally announced September 2020.
-
Status of the PANDA Barrel DIRC
Authors:
C. Schwarz,
A. Ali,
A. Belias,
R. Dzhygadlo,
A. Gerhardt,
M. Krebs,
D. Lehmann,
K. Peters,
G. Schepers,
J. Schwiening,
M. Traxler,
L. Schmitt,
M. Böhm,
A. Lehmann,
M. Pfaffinger,
S. Stelter,
F. Uhlig,
M. Düren,
E. Etzelmüller,
K. Föhl,
A. Hayrapetyan,
I. Köseoglu,
K. Kreutzfeld,
J. Rieke,
M. Schmidt
, et al. (2 additional authors not shown)
Abstract:
The PANDA experiment will use cooled antiproton beams with high intensity stored1 in the High Energy Storage Ring at FAIR. Reactions on a fixed target producing charmed hadrons will shed light on the strong QCD. Three ring imaging Cherenkov counters are used for charged particle identification. The status of the Barrel DIRC (Detection of Internally Reflected Cherenkov light) is described. Its desi…
▽ More
The PANDA experiment will use cooled antiproton beams with high intensity stored1 in the High Energy Storage Ring at FAIR. Reactions on a fixed target producing charmed hadrons will shed light on the strong QCD. Three ring imaging Cherenkov counters are used for charged particle identification. The status of the Barrel DIRC (Detection of Internally Reflected Cherenkov light) is described. Its design is robust and its performance validated in experiments with test beams. The PANDA Barrel DIRC has entered the construction phase and will be installed in 2023/2024.
△ Less
Submitted 2 April, 2020;
originally announced April 2020.
-
Technical Design Report for the PANDA Endcap Disc DIRC
Authors:
Panda Collaboration,
F. Davi,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
F. Feldbauer,
M. Fink,
V. Freudenreich,
M. Fritsch,
F. H. Heinsius,
T. Held,
T. Holtmann,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann
, et al. (441 additional authors not shown)
Abstract:
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c.…
▽ More
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c. PANDA is designed to reach a maximum luminosity of 2x10^32 cm^2 s. Most of the physics programs require an excellent particle identification (PID). The PID of hadronic states at the forward endcap of the target spectrometer will be done by a fast and compact Cherenkov detector that uses the detection of internally reflected Cherenkov light (DIRC) principle. It is designed to cover the polar angle range from 5° to 22° and to provide a separation power for the separation of charged pions and kaons up to 3 standard deviations (s.d.) for particle momenta up to 4 GeV/c in order to cover the important particle phase space. This document describes the technical design and the expected performance of the novel PANDA Disc DIRC detector that has not been used in any other high energy physics experiment (HEP) before. The performance has been studied with Monte-Carlo simulations and various beam tests at DESY and CERN. The final design meets all PANDA requirements and guarantees suffcient safety margins.
△ Less
Submitted 29 December, 2019;
originally announced December 2019.
-
Particle Identification with DIRCs at PANDA
Authors:
M. Düren,
A. Ali,
A. Belias,
R. Dzhygadlo,
A. Gerhardt,
M. Krebs,
D. Lehmann,
K. Peters,
G. Schepers,
C. Schwarz,
J. Schwiening,
M. Traxler,
L. Schmitt,
M. Boehm,
A. Lehmann,
M. Pfaffinger,
S. Stelter,
F. Uhlig,
E. Etzelmueller,
K. Foehl,
A. Hayrapetyan,
K. Kreutzfeld,
J. Rieke,
M. Schmidt,
T. Wasem
, et al. (1 additional authors not shown)
Abstract:
The DIRC technology (Detection of Internally Reflected Cherenkov light) offers an excellent possibility to minimize the form factor of Cherenkov detectors in hermetic high energy detectors. The PANDA experiment at FAIR in Germany will combine a barrel-shaped DIRC with a disc-shaped DIRC to cover an angular range of 5 to 140 degrees. Particle identification for pions and kaons with a separation pow…
▽ More
The DIRC technology (Detection of Internally Reflected Cherenkov light) offers an excellent possibility to minimize the form factor of Cherenkov detectors in hermetic high energy detectors. The PANDA experiment at FAIR in Germany will combine a barrel-shaped DIRC with a disc-shaped DIRC to cover an angular range of 5 to 140 degrees. Particle identification for pions and kaons with a separation power of 3 standard deviations or more will be provided for momenta between 0.5 GeV/c and 3.5 GeV/c in the barrel region and up to 4 GeV/c in the forward region. Even though the concept is simple, the design and construction of a DIRC is challenging. High precision optics and mechanics are required to maintain the angular information of the Cherenkov photons during multiple internal reflections and to focus the individual photons onto position sensitive photon detectors. These sensors must combine high efficiencies for single photons with low dark count rates and good timing resolution at high rates. The choice of radiation hard fused silica for the optical material and of MCP-PMT photon sensors is essential for DIRC detectors to survive in an environment of radiation and strong magnetic field. The two DIRC detectors differ in the focusing optics, in the treatment of chromatic dispersion and in the electronic readout systems. The technical design of the two DIRC detectors and their validation by testing prototypes in a mixed particle beam at CERN are presented.
△ Less
Submitted 27 December, 2019;
originally announced December 2019.
-
The Innovative Design of the PANDA Barrel DIRC
Authors:
G. Schepers,
A. Ali,
A. Belias,
R. Dzhygadlo,
A. Gerhardt,
M. Krebs,
D. Lehmann,
K. Peters,
C. Schwarz,
J. Schwiening,
M. Traxler,
L. Schmitt,
M. Böhm,
A. Lehmann,
M. Pfaffinger,
S. Stelter,
F. Uhlig,
M. Düren,
E. Etzelmüller,
K. Föhl,
A. Hayrapetyan,
K. Kreutzfeld,
J. Rieke,
M. Schmidt,
T. Wasem
, et al. (7 additional authors not shown)
Abstract:
The Barrel DIRC of the PANDA experiment at FAIR will cleanly separate pions from kaons for the physics program of PANDA. Innovative solutions for key components of the detector sitting in the strong magnetic field of the compact PANDA target spectrometer as well as two reconstruction methods were developed in an extensive prototype program. The technical design and present results from the test be…
▽ More
The Barrel DIRC of the PANDA experiment at FAIR will cleanly separate pions from kaons for the physics program of PANDA. Innovative solutions for key components of the detector sitting in the strong magnetic field of the compact PANDA target spectrometer as well as two reconstruction methods were developed in an extensive prototype program. The technical design and present results from the test beam campaigns at the CERN PS in 2017 and 2018 are discussed.
△ Less
Submitted 5 April, 2019;
originally announced April 2019.
-
The Barrel DIRC detector of PANDA
Authors:
C. Schwarz,
A. Ali,
A. Belias,
R. Dzhygadlo,
A. Gerhardt,
M. Krebs,
D. Lehmann,
K. Peters,
G. Schepers,
J. Schwiening,
M. Traxler,
L. Schmitt,
M. Böhm,
A. Lehmann,
M. Pfaffinger,
F. Uhlig,
S. Stelter,
M. Düren,
E. Etzelmüller,
K. Föhl,
A. Hayrapetyan,
K. Kreutzfeld,
J. Rieke,
M. Schmidt,
T. Wasem
, et al. (7 additional authors not shown)
Abstract:
The PANDA experiment is one of the four large experiments being built at FAIR in Darmstadt. It will use a cooled antiproton beam on a fixed target within the momentum range of 1.5 to 15 GeV/c to address questions of strong QCD, where the coupling constant $α_s \gtrsim 0.3$. The luminosity of up to $2 \cdot 10^{32} cm^{-2}s^{-1}$ and the momentum resolution of the antiproton beam down to \mbox{$Δ$p…
▽ More
The PANDA experiment is one of the four large experiments being built at FAIR in Darmstadt. It will use a cooled antiproton beam on a fixed target within the momentum range of 1.5 to 15 GeV/c to address questions of strong QCD, where the coupling constant $α_s \gtrsim 0.3$. The luminosity of up to $2 \cdot 10^{32} cm^{-2}s^{-1}$ and the momentum resolution of the antiproton beam down to \mbox{$Δ$p/p = 4$\cdot10^{-5}$} allows for high precision spectroscopy, especially for rare reaction processes. Above the production threshold for open charm mesons the production of kaons plays an important role for identifying the reaction. The DIRC principle allows for a compact particle identification for charged particles in a hermetic detector, limited in size by the electromagnetic lead tungstate calorimeter. The Barrel DIRC in the target spectrometer covers polar angles between $22^\circ$ and $140^\circ$ and will achieve a pion-kaon separation of 3 standard deviations up to 3.5 GeV/$c$. Here, results of a test beam are shown for a single radiator bar coupled to a prism with $33^\circ$ opening angle, both made from synthetic fused silica read out with a photon detector array with 768 pixels.
△ Less
Submitted 24 January, 2019;
originally announced January 2019.
-
The PANDA DIRC Detectors at FAIR
Authors:
C. Schwarz,
A. Ali,
A. Belias,
R. Dzhygadlo,
A. Gerhardt,
K. Goetzen,
G. Kalicy,
M. Krebs,
D. Lehmann,
F. Nerling,
M. Patsyuk,
K. Peters,
G. Schepers,
L. Schmitt,
J. Schwiening,
M. Traxler,
M. Zuehlsdorf,
M. Boehm,
A. Britting,
W. Eyrich,
A. Lehmann,
M. Pfaffinger,
F. Uhlig,
M. Dueren,
E. Etzelmueller
, et al. (17 additional authors not shown)
Abstract:
The PANDA detector at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR) addresses fundamental questions of hadron physics. An excellent hadronic particle identification (PID) will be accomplished by two DIRC (Detection of Internally Reflected Cherenkov light) counters in the target spectrometer. The design for the barrel region covering polar angles between 22…
▽ More
The PANDA detector at the international accelerator Facility for Antiproton and Ion Research in Europe (FAIR) addresses fundamental questions of hadron physics. An excellent hadronic particle identification (PID) will be accomplished by two DIRC (Detection of Internally Reflected Cherenkov light) counters in the target spectrometer. The design for the barrel region covering polar angles between 22 deg. to 140 deg. is based on the successful BABAR DIRC with several key improvements, such as fast photon timing and a compact imaging region. The novel Endcap Disc DIRC will cover the smaller forward angles between 5 deg. (10 deg.) to 22 deg. in the vertical (horizontal) direction. Both DIRC counters will use lifetime-enhanced microchannel plate PMTs for photon detection in combination with fast readout electronics. Geant4 simulations and tests with several prototypes at various beam facilities have been used to evaluate the designs and validate the expected PID performance of both PANDA DIRC counters.
△ Less
Submitted 28 July, 2017;
originally announced July 2017.
-
Feasibility study for the measurement of $πN$ TDAs at PANDA in $\bar{p}p\to J/ψπ^0$
Authors:
PANDA Collaboration,
B. Singh,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
M. Fink,
F. H. Heinsius,
T. Held,
T. Holtmann,
S. Jasper,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann,
M. Kümmel,
S. Leiber
, et al. (488 additional authors not shown)
Abstract:
The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as…
▽ More
The exclusive charmonium production process in $\bar{p}p$ annihilation with an associated $π^0$ meson $\bar{p}p\to J/ψπ^0$ is studied in the framework of QCD collinear factorization. The feasibility of measuring this reaction through the $J/ψ\to e^+e^-$ decay channel with the PANDA (AntiProton ANnihilation at DArmstadt) experiment is investigated. Simulations on signal reconstruction efficiency as well as the background rejection from various sources including the $\bar{p}p\toπ^+π^-π^0$ and $\bar{p}p\to J/ψπ^0π^0$ reactions are performed with PandaRoot, the simulation and analysis software framework of the PANDA experiment. It is shown that the measurement can be done at PANDA with significant constraining power under the assumption of an integrated luminosity attainable in four to five months of data taking at the maximum design luminosity.
△ Less
Submitted 7 October, 2016;
originally announced October 2016.
-
Feasibility studies of time-like proton electromagnetic form factors at PANDA at FAIR
Authors:
PANDA Collaboration,
B. Singh,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
B. Liu,
H. Liu,
Z. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
M. Fink,
F. Heinsius,
T. Held,
T. Holtmann,
S. Jasper,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann,
M. Kümmel,
S. Leiber
, et al. (482 additional authors not shown)
Abstract:
Simulation results for future measurements of electromagnetic proton form factors at \PANDA (FAIR) within the PandaRoot software framework are reported. The statistical precision with which the proton form factors can be determined is estimated. The signal channel $\bar p p \to e^+ e^-$ is studied on the basis of two different but consistent procedures. The suppression of the main background chann…
▽ More
Simulation results for future measurements of electromagnetic proton form factors at \PANDA (FAIR) within the PandaRoot software framework are reported. The statistical precision with which the proton form factors can be determined is estimated. The signal channel $\bar p p \to e^+ e^-$ is studied on the basis of two different but consistent procedures. The suppression of the main background channel, $\textit{i.e.}$ $\bar p p \to π^+ π^-$, is studied. Furthermore, the background versus signal efficiency, statistical and systematical uncertainties on the extracted proton form factors are evaluated using two different procedures. The results are consistent with those of a previous simulation study using an older, simplified framework. However, a slightly better precision is achieved in the PandaRoot study in a large range of momentum transfer, assuming the nominal beam conditions and detector performance.
△ Less
Submitted 29 September, 2016; v1 submitted 3 June, 2016;
originally announced June 2016.
-
Experimental access to Transition Distribution Amplitudes with the PANDA experiment at FAIR
Authors:
PANDA Collaboration,
B. P. Singh,
W. Erni,
I. Keshelashvili,
B. Krusche,
M. Steinacher %,
B. Liu,
H. Liu,
Z. Liu,
X. Shen,
C. Wang,
J. Zhao %,
M. Albrecht,
M. Fink,
F. H. Heinsius,
T. Held,
T. Holtmann,
H. Koch,
B. Kopf,
M. Kümmel,
G. Kuhl,
M. Kuhlmann,
M. Leyhe,
M. Mikirtychyants,
P. Musiol
, et al. (511 additional authors not shown)
Abstract:
Baryon-to-meson Transition Distribution Amplitudes (TDAs) encoding valuable new information on hadron structure appear as building blocks in the collinear factorized description for several types of hard exclusive reactions. In this paper, we address the possibility of accessing nucleon-to-pion ($πN$) TDAs from $\bar{p}p \to e^+e^- π^0$ reaction with the future PANDA detector at the FAIR facility.…
▽ More
Baryon-to-meson Transition Distribution Amplitudes (TDAs) encoding valuable new information on hadron structure appear as building blocks in the collinear factorized description for several types of hard exclusive reactions. In this paper, we address the possibility of accessing nucleon-to-pion ($πN$) TDAs from $\bar{p}p \to e^+e^- π^0$ reaction with the future PANDA detector at the FAIR facility. At high center of mass energy and high invariant mass squared of the lepton pair $q^2$, the amplitude of the signal channel $\bar{p}p \to e^+e^- π^0$ admits a QCD factorized description in terms of $πN$ TDAs and nucleon Distribution Amplitudes (DAs) in the forward and backward kinematic regimes. Assuming the validity of this factorized description, we perform feasibility studies for measuring $\bar{p}p \to e^+e^- π^0$ with the PANDA detector. Detailed simulations on signal reconstruction efficiency as well as on rejection of the most severe background channel, i.e. $\bar{p}p \to π^+π^- π^0$ were performed for the center of mass energy squared $s = 5$ GeV$^2$ and $s = 10$ GeV$^2$, in the kinematic regions $3.0 < q^2 < 4.3$ GeV$^2$ and $5 < q^2 < 9$ GeV$^2$, respectively, with a neutral pion scattered in the forward or backward cone $| \cosθ_{π^0}| > 0.5 $ in the proton-antiproton center of mass frame. Results of the simulation show that the particle identification capabilities of the PANDA detector will allow to achieve a background rejection factor of $5\cdot 10^7$ ($1\cdot 10^7$) at low (high) $q^2$ for $s=5$ GeV$^2$, and of $1\cdot 10^8$ ($6\cdot 10^6$) at low (high) $q^2$ for $s=10$ GeV$^2$, while kee** the signal reconstruction efficiency at around $40\%$. At both energies, a clean lepton signal can be reconstructed with the expected statistics corresponding to $2$ fb$^{-1}$ of integrated luminosity. (.../...)
△ Less
Submitted 30 November, 2016; v1 submitted 2 September, 2014;
originally announced September 2014.