-
Comparative Analysis of Jet and Underlying Event Properties Across Various Models as a Function of Charged Particle Multiplicity at 7 TeV
Authors:
Maryam Waqar,
Haifa I. Alrebdi,
Muhammad Waqas,
K. S. Al-mugren,
Muhammad Ajaz
Abstract:
In this study, a comprehensive analysis of jets and underlying events as a function of charged particle multiplicity in proton-proton (pp) collisions at a center-of-mass energy of $\sqrt{s} = 7$ TeV is presented. Various Monte Carlo (MC) event generators, including Pythia8.308, EPOS1.99, EPOSLHC, EPOS4$_{Hydro}$, and EPOS4$_{noHydro}$, are employed to predict particle production. The predictions f…
▽ More
In this study, a comprehensive analysis of jets and underlying events as a function of charged particle multiplicity in proton-proton (pp) collisions at a center-of-mass energy of $\sqrt{s} = 7$ TeV is presented. Various Monte Carlo (MC) event generators, including Pythia8.308, EPOS1.99, EPOSLHC, EPOS4$_{Hydro}$, and EPOS4$_{noHydro}$, are employed to predict particle production. The predictions from these models are compared with experimental data from the CMS collaboration. The charged particles are categorized into those associated with underlying events and those linked to jets. The analysis is restricted to charged particles with $|η| < 2.4$ and $p_{T} > 0.25$ GeV/c. Upon comparing the MC predictions with CMS data, it is observed that EPOS$4_{Hydro}$, EPOSLHC, and Pythia8 consistently reproduce the experimental results for all charged particles, underlying events, intrajet, and leading charged particles. For charged jet rates with $p_{T}^{ch.jet} > 5$ GeV/c, EPOS4$_{Hydro}$ and Pythia8 perform exceptionally well. In the case of charged jet rates with $p_{T}^{ch.jet} > 30$ GeV/c, EPOSLHC reproduces satisfactorily good results, while EPOS4$_{Hydro}$ exhibits good agreement with the data at higher charged particle multiplicities as compared to the other models. This can be attributed to the conversion of energy into flow when "Hydro=on," leading to an increase in multiplicity. EPOSLHC model described the data well due to the new collective flow effects, correlated flow treatment, and parametrization as compared to the EPOS1.99. However, the examination of the jet $p_{T}$ spectrum and normalized charged $p_{T}$ density reveals that EPOS4$_{Hydro}$, EPOS4$_{noHydro}$, and EPOSLHC exhibit good agreement with the experimental results, while Pythia8 and EPOS1.99 do not perform as well due to the lack of correlated flow treatment.
△ Less
Submitted 25 June, 2024;
originally announced June 2024.
-
A multiscale generative model to understand disorder in domain boundaries
Authors:
Jiadong Dan,
Moaz Waqar,
Ivan Erofeev,
Kui Yao,
John Wang,
Stephen J. Pennycook,
N. Duane Loh
Abstract:
A continuing challenge in atomic resolution microscopy is to identify significant structural motifs and their assembly rules in synthesized materials with limited observations. Here we propose and validate a simple and effective hybrid generative model capable of predicting unseen domain boundaries in a potassium sodium niobate thin film from only a small number of observations, without expensive…
▽ More
A continuing challenge in atomic resolution microscopy is to identify significant structural motifs and their assembly rules in synthesized materials with limited observations. Here we propose and validate a simple and effective hybrid generative model capable of predicting unseen domain boundaries in a potassium sodium niobate thin film from only a small number of observations, without expensive first-principles calculation. Our results demonstrate that complicated domain boundary structures can arise from simple interpretable local rules, played out probabilistically. We also found new significant tileable boundary motifs and evidence that our system creates domain boundaries with the highest entropy. More broadly, our work shows that simple yet interpretable machine learning models can help us describe and understand the nature and origin of disorder in complex materials.
△ Less
Submitted 22 May, 2023;
originally announced May 2023.
-
First direct detection constraints on Planck-scale mass dark matter with multiple-scatter signatures using the DEAP-3600 detector
Authors:
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
D. J. Auty,
H. Benmansour,
C. E. Bina,
W. Bonivento,
M. G. Boulay,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
Y. Chen,
B. T. Cleveland,
J. M. Corning,
S. Daugherty,
P. DelGobbo,
P. Di Stefano,
L. Doria,
M. Dunford,
E. Ellingwood,
A. Erlandson,
S. S. Farahani,
N. Fatemighomi,
G. Fiorillo
, et al. (72 additional authors not shown)
Abstract:
Dark matter particles with Planck-scale mass ($\simeq10^{19}\text{GeV}/c^2$) arise in well-motivated theories and could be produced by several cosmological mechanisms. Using a blind analysis of data collected over a 813 d live time with DEAP-3600, a 3.3 t single-phase liquid argon-based dark matter experiment at SNOLAB, a search for supermassive dark matter was performed, looking for multiple-scat…
▽ More
Dark matter particles with Planck-scale mass ($\simeq10^{19}\text{GeV}/c^2$) arise in well-motivated theories and could be produced by several cosmological mechanisms. Using a blind analysis of data collected over a 813 d live time with DEAP-3600, a 3.3 t single-phase liquid argon-based dark matter experiment at SNOLAB, a search for supermassive dark matter was performed, looking for multiple-scatter signals. No candidate signal events were observed, leading to the first direct detection constraints on Planck-scale mass dark matter. Leading limits constrain dark matter masses between $8.3\times10^{6}$ and $1.2\times10^{19} \text{GeV}/c^2$, and cross sections for scattering on $^{40}$Ar between $1.0\times10^{-23}$ and $2.4\times10^{-18} \text{cm}^2$. These are used to constrain two composite dark matter models.
△ Less
Submitted 5 January, 2022; v1 submitted 20 August, 2021;
originally announced August 2021.
-
Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data
Authors:
The DEAP Collaboration,
P. Adhikari,
R. Ajaj,
M. Alpízar-Venegas,
P. -A. Amaudruz,
D. J. Auty,
M. Batygov,
B. Beltran,
H. Benmansour,
C. E. Bina,
J. Bonatt,
W. Bonivento,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen,
B. T. Cleveland,
J. M. Corning
, et al. (104 additional authors not shown)
Abstract:
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD).
We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window ar…
▽ More
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD).
We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window around the event peak, and the log-likelihood-ratio, which compares the observed photon arrival times to a signal and a background model. We furthermore use two algorithms to determine the number of photons detected at a given time: (1) simply dividing the charge of each PMT pulse by the charge of a single photoelectron, and (2) a likelihood analysis that considers the probability to detect a certain number of photons at a given time, based on a model for the scintillation pulseshape and for afterpulsing in the light detectors.
The prompt-fraction performs approximately as well as the log-likelihood-ratio PSD algorithm if the photon detection times are not biased by detector effects. We explain this result using a model for the information carried by scintillation photons as a function of the time when they are detected.
△ Less
Submitted 6 April, 2021; v1 submitted 22 March, 2021;
originally announced March 2021.
-
Constraints on dark matter-nucleon effective couplings in the presence of kinematically distinct halo substructures using the DEAP-3600 detector
Authors:
P. Adhikari,
R. Ajaj,
C. E. Bina,
W. Bonivento,
M. G. Boulay,
M. Cadeddu,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
Y. Chen,
B. T. Cleveland,
J. M. Corning,
S. Daugherty,
P. DelGobbo,
P. Di Stefano,
L. Doria,
M. Dunford,
A. Erlandson,
S. S. Farahani,
N. Fatemighomi,
G. Fiorillo,
D. Gallacher,
E. A. Garcés,
P. García Abia,
S. Garg
, et al. (59 additional authors not shown)
Abstract:
DEAP-3600 is a single-phase liquid argon detector aiming to directly detect Weakly Interacting Massive Particles (WIMPs), located at SNOLAB (Sudbury, Canada). After analyzing data taken during the first year of operation, a null result was used to place an upper bound on the WIMP-nucleon spin-independent, isoscalar cross section. This study reinterprets this result within a Non-Relativistic Effect…
▽ More
DEAP-3600 is a single-phase liquid argon detector aiming to directly detect Weakly Interacting Massive Particles (WIMPs), located at SNOLAB (Sudbury, Canada). After analyzing data taken during the first year of operation, a null result was used to place an upper bound on the WIMP-nucleon spin-independent, isoscalar cross section. This study reinterprets this result within a Non-Relativistic Effective Field Theory framework, and further examines how various possible substructures in the local dark matter halo may affect these constraints. Such substructures are hinted at by kinematic structures in the local stellar distribution observed by the Gaia satellite and other recent astronomical surveys. These include the Gaia Sausage (or Enceladus), as well as a number of distinct streams identified in recent studies. Limits are presented for the coupling strength of the effective contact interaction operators $\mathcal{O}_1$, $\mathcal{O}_3$, $\mathcal{O}_5$, $\mathcal{O}_8$, and $\mathcal{O}_{11}$, considering isoscalar, isovector, and xenonphobic scenarios, as well as the specific operators corresponding to millicharge, magnetic dipole, electric dipole, and anapole interactions. The effects of halo substructures on each of these operators are explored as well, showing that the $\mathcal{O}_5$ and $\mathcal{O}_8$ operators are particularly sensitive to the velocity distribution, even at dark matter masses above 100 GeV/$c^2$.
△ Less
Submitted 5 January, 2022; v1 submitted 29 May, 2020;
originally announced May 2020.
-
The liquid-argon scintillation pulseshape in DEAP-3600
Authors:
The DEAP collaboration,
P. Adhikari,
R. Ajaj,
G. R. Araujoand M. Batygov,
B. Beltran,
C. E. Bina,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
A. Butcher,
B. Cai,
M. Cárdenas-Montes,
S. Cavuoti,
Y. Chen,
B. T. Cleveland,
J. M. Corning,
S. J. Daughertyand K. Dering,
L. Doria,
F. A. Duncan andM. Dunford,
A. Erlandson,
N. Fatemighomi,
G. Fiorillo,
A. Flower,
R. J. Ford,
R. Gagnon
, et al. (76 additional authors not shown)
Abstract:
DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed…
▽ More
DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed here is the basis of PSD.
The observed pulseshape is a combination of LAr scintillation physics with detector effects. We present a model for the pulseshape of electromagnetic background events in the energy region of interest for dark matter searches. The model is composed of a) LAr scintillation physics, including the so-called intermediate component, b) the time response of the TPB wavelength shifter, including delayed TPB emission at $\mathcal O$(ms) time-scales, and c) PMT response.
TPB is the wavelength shifter of choice in most LAr detectors. We find that approximately 10\% of the intensity of the wavelength-shifted light is in a long-lived state of TPB. This causes light from an event to spill into subsequent events to an extent not usually accounted for in the design and data analysis of LAr-based detectors.
△ Less
Submitted 8 June, 2020; v1 submitted 27 January, 2020;
originally announced January 2020.
-
Electromagnetic Backgrounds and Potassium-42 Activity in the DEAP-3600 Dark Matter Detector
Authors:
R. Ajaj,
G. R. Araujo,
M. Batygov,
B. Beltran,
C. E. Bina,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
M. Cárdenas-Montes,
S. Cavuoti,
M. Chen,
Y. Chen,
B. T. Cleveland,
K. Dering,
F. A. Duncan,
M. Dunford,
A. Erlandson,
N. Fatemighomi,
G. Fiorillo,
A. Flower,
R. J. Ford,
D. Gallacher,
P. García Abia
, et al. (66 additional authors not shown)
Abstract:
The DEAP-3600 experiment is searching for WIMP dark matter with a 3.3 tonne single phase liquid argon (LAr) target, located 2.1 km underground at SNOLAB. The experimental signature of dark matter interactions is keV-scale $^{40}$Ar nuclear recoils (NR) producing 128 nm LAr scintillation photons observed by PMTs. The largest backgrounds in DEAP-3600 are electronic recoils (ER) induced by $β$ and…
▽ More
The DEAP-3600 experiment is searching for WIMP dark matter with a 3.3 tonne single phase liquid argon (LAr) target, located 2.1 km underground at SNOLAB. The experimental signature of dark matter interactions is keV-scale $^{40}$Ar nuclear recoils (NR) producing 128 nm LAr scintillation photons observed by PMTs. The largest backgrounds in DEAP-3600 are electronic recoils (ER) induced by $β$ and $γ$-rays originating from internal and external radioactivity in the detector material. A background model of the ER interactions in DEAP-3600 was developed and is described in this work. The model is based on several components which are expected from radioisotopes in the LAr, from ex-situ material assay measurements, and from dedicated independent in-situ analyses. This prior information is used in a Bayesian fit of the ER components to a 247.2 d dataset to model the radioactivity in the surrounding detector materials. While excellent discrimination between ERs and NRs is reached with pulse shape discrimination, utilizing the large difference between fast and slow components of LAr scintillation light, detailed knowledge of the ER background and activity of detector components, sets valuable constraints on other key types of backgrounds in the detector: neutrons and alphas. In addition, the activity of $^{42}$Ar in LAr in DEAP-3600 is determined by measuring the daughter decay of $^{42}$K. This cosmogenically activated trace isotope is a relevant background at higher energies for other rare event searches using atmospheric argon e.g. DarkSide-20k, GERDA or LEGEND. The specific activity of $^{42}$Ar in the atmosphere is found to be $40.4 \pm 5.9$ $μ$Bq/kg of argon.
△ Less
Submitted 14 May, 2019;
originally announced May 2019.
-
Search for dark matter with a 231-day exposure of liquid argon using DEAP-3600 at SNOLAB
Authors:
R. Ajaj,
P. -A. Amaudruz,
G. R. Araujo,
M. Baldwin,
M. Batygov,
B. Beltran,
C. E. Bina,
J. Bonatt,
M. G. Boulay,
B. Broerman,
J. F. Bueno,
P. M. Burghardt,
A. Butcher,
B. Cai,
S. Cavuoti,
M. Chen,
Y. Chen,
B. T. Cleveland,
D. Cranshaw,
K. Dering,
J. DiGioseffo,
L. Doria,
F. A. Duncan,
M. Dunford,
A. Erlandson
, et al. (77 additional authors not shown)
Abstract:
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of LAr contained in a spherical acrylic vessel. This paper reports on the analysis of a 758 tonne\cdot day exposure taken over a period of 231 live-days during the first year of operation. No candidate signal events are obs…
▽ More
DEAP-3600 is a single-phase liquid argon (LAr) direct-detection dark matter experiment, operating 2 km underground at SNOLAB (Sudbury, Canada). The detector consists of 3279 kg of LAr contained in a spherical acrylic vessel. This paper reports on the analysis of a 758 tonne\cdot day exposure taken over a period of 231 live-days during the first year of operation. No candidate signal events are observed in the WIMP-search region of interest, which results in the leading limit on the WIMP-nucleon spin-independent cross section on a LAr target of $3.9\times10^{-45}$ cm$^{2}$ ($1.5\times10^{-44}$ cm$^{2}$) for a 100 GeV/c$^{2}$ (1 TeV/c$^{2}$) WIMP mass at 90\% C. L. In addition to a detailed background model, this analysis demonstrates the best pulse-shape discrimination in LAr at threshold, employs a Bayesian photoelectron-counting technique to improve the energy resolution and discrimination efficiency, and utilizes two position reconstruction algorithms based on PMT charge and photon arrival times.
△ Less
Submitted 4 July, 2019; v1 submitted 11 February, 2019;
originally announced February 2019.
-
A Batteryless Sensor ASIC for Implantable Bio-impedance Applications
Authors:
Saul Rodriguez,
Stig Ollmar,
Muhammad Waqar,
Ana Rusu
Abstract:
The measurement of the biological tissue's electrical impedance is an active research field that has attracted a lot of attention during the last decades. Bio-impedances are closely related to a large variety of physiological conditions; therefore, they are useful for diagnosis and monitoring in many medical applications. Measuring living tissues, however, is a challenging task that poses countles…
▽ More
The measurement of the biological tissue's electrical impedance is an active research field that has attracted a lot of attention during the last decades. Bio-impedances are closely related to a large variety of physiological conditions; therefore, they are useful for diagnosis and monitoring in many medical applications. Measuring living tissues, however, is a challenging task that poses countless technical and practical problems, in particular if the tissues need to be measured under the skin. This paper presents a bio-impedance sensor ASIC targeting a battery-free, miniature size, implantable device, which performs accurate 4-point complex impedance extraction in the frequency range from 2 kHz to 2 MHz. The ASIC is fabricated in 150 nm CMOS, has a size of 1.22 mm x 1.22 mm and consumes 165 uA from a 1.8 V power supply. The ASIC is embedded in a prototype which communicates with, and is powered by an external reader device through inductive coupling. The prototype is validated by measuring the impedances of different combinations of discrete components, measuring the electrochemical impedance of physiological solution, and performing ex vivo measurements on animal organs. The proposed ASIC is able to extract complex impedances with around 1 Ohm resolution; therefore enabling accurate wireless tissue measurements.
△ Less
Submitted 13 July, 2015;
originally announced July 2015.