-
Replicability of Simulation Studies for the Investigation of Statistical Methods: The RepliSims Project
Authors:
K. Luijken,
A. Lohmann,
U. Alter,
J. Claramunt Gonzalez,
F. J. Clouth,
J. L. Fossum,
L. Hesen,
A. H. J. Huizing,
J. Ketelaar,
A. K. Montoya,
L. Nab,
R. C. C. Nijman,
B. B. L. Penning de Vries,
T. D. Tibbe,
Y. A. Wang,
R. H. H. Groenwold
Abstract:
Results of simulation studies evaluating the performance of statistical methods are often considered actionable and thus can have a major impact on the way empirical research is implemented. However, so far there is limited evidence about the reproducibility and replicability of statistical simulation studies. Therefore, eight highly cited statistical simulation studies were selected, and their re…
▽ More
Results of simulation studies evaluating the performance of statistical methods are often considered actionable and thus can have a major impact on the way empirical research is implemented. However, so far there is limited evidence about the reproducibility and replicability of statistical simulation studies. Therefore, eight highly cited statistical simulation studies were selected, and their replicability was assessed by teams of replicators with formal training in quantitative methodology. The teams found relevant information in the original publications and used it to write simulation code with the aim of replicating the results. The primary outcome was the feasibility of replicability based on reported information in the original publications. Replicability varied greatly: Some original studies provided detailed information leading to almost perfect replication of results, whereas other studies did not provide enough information to implement any of the reported simulations. Replicators had to make choices regarding missing or ambiguous information in the original studies, error handling, and software environment. Factors facilitating replication included public availability of code, and descriptions of the data-generating procedure and methods in graphs, formulas, structured text, and publicly accessible additional resources such as technical reports. Replicability of statistical simulation studies was mainly impeded by lack of information and sustainability of information sources. Reproducibility could be achieved for simulation studies by providing open code and data as a supplement to the publication. Additionally, simulation studies should be transparently reported with all relevant information either in the research paper itself or in easily accessible supplementary material to allow for replicability.
△ Less
Submitted 5 July, 2023;
originally announced July 2023.
-
5-Minute Magnetic Particle Spectroscopy (MPS)-based Bioassay: Towards Ultra-fast, Convenient, and Large-scale Disease Diagnosis
Authors:
Kai Wu,
Vinit Kumar Chugh,
Venkatramana D. Krishna,
Yongqiang Andrew Wang,
Timothy D. Gordon,
Maxim C-J Cheeran,
Jian-** Wang
Abstract:
In this work, we report a 5-minute magnetic particle spectroscopy (MPS)-based bioassay strategy. In our approach, surface functionalized magnetic nanoparticles (MNPs) are incubated with target analytes at 37 °C with agitation for 3 minutes and the MPS reading is then taken at the 5th minute. We have proved the feasibility of 5-minute ultra-fast detection of SARS-CoV-2 spike protein with a detectio…
▽ More
In this work, we report a 5-minute magnetic particle spectroscopy (MPS)-based bioassay strategy. In our approach, surface functionalized magnetic nanoparticles (MNPs) are incubated with target analytes at 37 °C with agitation for 3 minutes and the MPS reading is then taken at the 5th minute. We have proved the feasibility of 5-minute ultra-fast detection of SARS-CoV-2 spike protein with a detection limit below 5 nM (0.2 pmole). Our proposed 5-minute bioassay strategy may be applied to reduce assay time for other liquid phase, volumetric biosensors such as nuclear magnetic resonance (NMR), quantum dots (QD), fluorescent biosensors, etc.
△ Less
Submitted 25 September, 2022;
originally announced October 2022.
-
One-step, Wash-free, Nanoparticle Clustering-based Magnetic Particle Spectroscopy (MPS) Bioassay Method for Detection of SARS-CoV-2 Spike and Nucleocapsid Proteins in Liquid Phase
Authors:
Kai Wu,
Vinit Kumar Chugh,
Venkatramana D. Krishna,
Arturo di Girolamo,
Yongqiang Andrew Wang,
Renata Saha,
Shuang Liang,
Maxim C-J Cheeran,
Jian-** Wang
Abstract:
With the ongoing global pandemic of coronavirus disease 2019 (COVID-19), there is an increasing quest for more accessible, easy-to-use, rapid, inexpensive, and high accuracy diagnostic tools. Traditional disease diagnostic methods such as qRT-PCR (quantitative reverse transcription-PCR) and ELISA (enzyme-linked immunosorbent assay) require multiple steps, trained technicians, and long turnaround t…
▽ More
With the ongoing global pandemic of coronavirus disease 2019 (COVID-19), there is an increasing quest for more accessible, easy-to-use, rapid, inexpensive, and high accuracy diagnostic tools. Traditional disease diagnostic methods such as qRT-PCR (quantitative reverse transcription-PCR) and ELISA (enzyme-linked immunosorbent assay) require multiple steps, trained technicians, and long turnaround time that may worsen the disease surveillance and pandemic control. In sight of this situation, a rapid, one-step, easy-to-use, and high accuracy diagnostic platform will be valuable for future epidemic control especially for regions with scarce medical resources. Herein, we report a magnetic particle spectroscopy (MPS) platform for detection of SARS-CoV-2 biomarkers: spike and nucleocapsid proteins.
△ Less
Submitted 1 August, 2021;
originally announced August 2021.
-
Magnetic Particle Spectroscopy (MPS) with One-stage Lock-in Implementation for Magnetic Bioassays with Improved Sensitivities
Authors:
Vinit Kumar Chugh,
Kai Wu,
Venkatramana D. Krishna,
Arturo di Girolamo,
Robert P. Bloom,
Yongqiang Andrew Wang,
Renata Saha,
Shuang Liang,
Maxim C-J Cheeran,
Jian-** Wang
Abstract:
In recent years, magnetic particle spectroscopy (MPS) has become a highly sensitive and versatile sensing technique for quantitative bioassays. It relies on the dynamic magnetic responses of magnetic nanoparticles (MNPs) for the detection of target analytes in liquid phase. There are many research studies reporting the application of MPS for detecting a variety of analytes including viruses, toxin…
▽ More
In recent years, magnetic particle spectroscopy (MPS) has become a highly sensitive and versatile sensing technique for quantitative bioassays. It relies on the dynamic magnetic responses of magnetic nanoparticles (MNPs) for the detection of target analytes in liquid phase. There are many research studies reporting the application of MPS for detecting a variety of analytes including viruses, toxins, and nucleic acids, etc. Herein, we report a modified version of MPS platform with the addition of a one-stage lock-in design to remove the feedthrough signals induced by external driving magnetic fields, thus capturing only MNP responses for improved system sensitivity. This one-stage lock-in MPS system is able to detect as low as 781 ng multi-core Nanomag50 iron oxide MNPs (micromod Partikeltechnologie GmbH) and 78 ng single-core SHB30 iron oxide MNPs (Ocean NanoTech). In addition, using a streptavidin-biotin binding system as a proof-of-concept, we show that these single-core SHB30 MNPs can be used for Brownian relaxation-based bioassays while the multi-core Nanomag50 cannot be used. The effects of MNP amount on the concentration dependent response profiles for detecting streptavidin was also investigated. Results show that by using lower concentration/amount of MNPs, concentration-response curves shift to lower concentration/amount of target analytes. This lower concentrationresponse indicates the possibility of improved bioassay sensitivities by using lower amounts of MNPs.
△ Less
Submitted 26 May, 2021;
originally announced May 2021.