-
Optimization of WLS fiber readout for the HERD calorimeter
Authors:
X. Liu,
Z. Quan,
Y. W. Dong,
M. Xu,
J. J. Wang,
R. J. Wang,
Z. G. Wang,
X. Z. Cui,
T. W. Bao,
C. L. Liao,
J. F. Han,
Y. Chen
Abstract:
A novel 3-D calorimeter, composed of about 7500 LYSO cubes, is the key and crucial detector of the High Energy cosmic-Radiation Detection (HERD) facility to be installed onboard the China Space Station. Energy deposition from cosmic ray in each LYSO cube is translated by multiple wavelength shifting (WLS) fibers for multi-range data acquisition and real-time triggering.
In this study, various me…
▽ More
A novel 3-D calorimeter, composed of about 7500 LYSO cubes, is the key and crucial detector of the High Energy cosmic-Radiation Detection (HERD) facility to be installed onboard the China Space Station. Energy deposition from cosmic ray in each LYSO cube is translated by multiple wavelength shifting (WLS) fibers for multi-range data acquisition and real-time triggering.
In this study, various methods of surface finish and encapsulation of the LYSO cube were investigated to optimize the amplitude from the WLS fiber end with the aim of improving the signal-to-noise ratio of Intensified scientific CMOS (IsCMOS) collection. The LYSO cube with five rough surfaces and a specular reflector achieves the maximum amplitude at the low-range fiber end, which is increased by roughly 44% compared to the polished cube with PTFE wrap**.
The non-uniformity of amplitude at different positions on the LYSO cube surface was measured by X-ray and the positional correlation factor was derived for the entire cube. A simulation based on HERD CALO was conducted, which revealed that both the LYSO cube with five rough surfaces and the cube with rough bottom face exhibit superior energy resolution for electrons compared to the other two configurations.
△ Less
Submitted 29 August, 2023;
originally announced August 2023.
-
Pelee: A Real-Time Object Detection System on Mobile Devices
Authors:
Robert J. Wang,
Xiang Li,
Charles X. Ling
Abstract:
An increasing need of running Convolutional Neural Network (CNN) models on mobile devices with limited computing power and memory resource encourages studies on efficient model design. A number of efficient architectures have been proposed in recent years, for example, MobileNet, ShuffleNet, and MobileNetV2. However, all these models are heavily dependent on depthwise separable convolution which l…
▽ More
An increasing need of running Convolutional Neural Network (CNN) models on mobile devices with limited computing power and memory resource encourages studies on efficient model design. A number of efficient architectures have been proposed in recent years, for example, MobileNet, ShuffleNet, and MobileNetV2. However, all these models are heavily dependent on depthwise separable convolution which lacks efficient implementation in most deep learning frameworks. In this study, we propose an efficient architecture named PeleeNet, which is built with conventional convolution instead. On ImageNet ILSVRC 2012 dataset, our proposed PeleeNet achieves a higher accuracy and over 1.8 times faster speed than MobileNet and MobileNetV2 on NVIDIA TX2. Meanwhile, PeleeNet is only 66% of the model size of MobileNet. We then propose a real-time object detection system by combining PeleeNet with Single Shot MultiBox Detector (SSD) method and optimizing the architecture for fast speed. Our proposed detection system2, named Pelee, achieves 76.4% mAP (mean average precision) on PASCAL VOC2007 and 22.4 mAP on MS COCO dataset at the speed of 23.6 FPS on iPhone 8 and 125 FPS on NVIDIA TX2. The result on COCO outperforms YOLOv2 in consideration of a higher precision, 13.6 times lower computational cost and 11.3 times smaller model size.
△ Less
Submitted 18 January, 2019; v1 submitted 18 April, 2018;
originally announced April 2018.
-
Design and construction of the POLAR detector
Authors:
N. Produit,
T. W. Bao,
T. Batsch,
T. Bernasconi,
I. Britvich,
F. Cadoux,
I. Cernuda,
J. Y. Chai,
Y. W. Dong,
N. Gauvin,
W. Hajdas,
M. Kole,
M. N. Kong,
R. Kramert,
L. Li,
J. T. Liu,
X. Liu,
R. Marcinkowski,
S. Orsi,
M. Pohl,
D. Rapin,
D. Rybka,
A. Rutczynska,
H. L. Shi,
P. Socha
, et al. (13 additional authors not shown)
Abstract:
The POLAR detector is a space based Gamma Ray Burst (GRB) polarimeter with a wide field of view, which covers almost half the sky. The instrument uses Compton scattering of gamma rays on a plastic scintillator hodoscope to measure the polarization of the incoming photons. The instrument has been successfully launched on board of the Chinese space laboratory Tiangong~2 on September 15, 2016. The co…
▽ More
The POLAR detector is a space based Gamma Ray Burst (GRB) polarimeter with a wide field of view, which covers almost half the sky. The instrument uses Compton scattering of gamma rays on a plastic scintillator hodoscope to measure the polarization of the incoming photons. The instrument has been successfully launched on board of the Chinese space laboratory Tiangong~2 on September 15, 2016. The construction of the instrument components is described in this article. Details are provided on problems encountered during the construction phase and their solutions. Initial performance of the instrument in orbit is as expected from ground tests and Monte Carlo simulation.
△ Less
Submitted 28 September, 2017; v1 submitted 21 September, 2017;
originally announced September 2017.
-
Instrument Performance and Simulation Verification of the POLAR Detector
Authors:
M. Kole,
Z. H. Li,
N. Produit,
T. Tymieniecka,
J. Zhang,
A. Zwolinska,
T. W. Bao,
T. Bernasconi,
F. Cadoux,
M. Z. Feng,
N. Gauvin,
W. Hajdas,
S. W. Kong,
H. C. Li,
L. Li,
X. Liu,
R. Marcinkowski,
S. Orsi,
M. Pohl,
D. Rybka,
J. C. Sun,
L. M. Song,
J. Szabelski,
R. J. Wang,
Y. H. Wang
, et al. (10 additional authors not shown)
Abstract:
POLAR is a new satellite-born detector aiming to measure the polarization of an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of September 2016, is designed to measure the polarization of the hard X-ray flux by measuring the distribution of the azimuthal scattering angles of the incoming photo…
▽ More
POLAR is a new satellite-born detector aiming to measure the polarization of an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of September 2016, is designed to measure the polarization of the hard X-ray flux by measuring the distribution of the azimuthal scattering angles of the incoming photons. A detailed understanding of the polarimeter and specifically of the systematic effects induced by the instrument's non-uniformity are required for this purpose. In order to study the instrument's response to polarization, POLAR underwent a beam test at the European Synchrotron Radiation Facility in France. In this paper both the beam test and the instrument performance will be described. This is followed by an overview of the Monte Carlo simulation tools developed for the instrument. Finally a comparison of the measured and simulated instrument performance will be provided and the instrument response to polarization will be presented.
△ Less
Submitted 2 August, 2017;
originally announced August 2017.
-
Calibration of the Space-borne Compton Polarimeter POLAR flight model with 100% polarized X-ray beams
Authors:
H. L. Xiao,
W. Hajdas,
P. Socha,
R. Marcinkowski,
B. B. Wu,
T. W. Bao,
J. Y. Chai,
Y. W. Dong,
M. N. Kong,
L. Li,
Z. H. Li,
J. T. Liu,
H. L. Shi,
L. M. Song,
J. C. Sun,
R. J. Wang,
Y. H. Wang,
X. Wen,
S. L. Xiong,
J. Zhang,
L. Y. Zhang,
S. N. Zhang,
X. F. Zhang,
Y. J. Zhang,
F. Cadoux
, et al. (10 additional authors not shown)
Abstract:
POLAR is space-borne detector designed for a precise measurement of gamma-ray polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50 keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$ 40 plastic scintillator bars read out by 25 multi-anode PMTs. In May 2015, we performed a series of tests of the POLAR flight model with 100\% polarized x-rays bea…
▽ More
POLAR is space-borne detector designed for a precise measurement of gamma-ray polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50 keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$ 40 plastic scintillator bars read out by 25 multi-anode PMTs. In May 2015, we performed a series of tests of the POLAR flight model with 100\% polarized x-rays beams at the European Synchrotron Radiation Facility beam-line ID11 aming to study thresholds, crosstalk between channels and responses of POLAR flight model to polarized X-ray beams. In this paper we present the data analysis method and some analysis results. According the results, POLAR FM has good polarimetric capabilities.
△ Less
Submitted 24 April, 2017; v1 submitted 20 April, 2017;
originally announced April 2017.
-
Gain factor and parameter settings optimization of the new gamma-ray burst polarimeter POLAR
Authors:
X. F. Zhang,
W. Hajdas,
H. L. Xiao,
X. Wen,
B. B. Wu,
T. W. Bao,
T. Batsch,
T. Bernasconi,
F. Cadoux,
I. Cernuda,
J. Y. Chai,
Y. W. Dong,
N. Gauvin,
J. J. He,
M. Kole,
M. N. Kong,
C. Lechanoine-Leluc,
L. Li,
Z. H. Li,
J. T. Liu,
X. Liu,
R. Marcinkowski,
S. Orsi,
M. Pohl,
D. Rapin
, et al. (16 additional authors not shown)
Abstract:
As a space-borne detector POLAR is designed to conduct hard X-ray polarization measurements of gamma-ray bursts on the statistically significant sample of events and with an unprecedented accuracy. During its development phase a number of tests, calibrations runs and verification measurements were carried out in order to validate instrument functionality and optimize operational parameters. In thi…
▽ More
As a space-borne detector POLAR is designed to conduct hard X-ray polarization measurements of gamma-ray bursts on the statistically significant sample of events and with an unprecedented accuracy. During its development phase a number of tests, calibrations runs and verification measurements were carried out in order to validate instrument functionality and optimize operational parameters. In this article we present results on gain optimization togeter with verification data obtained in the course of broad laboratory and environmental tests. In particular we focus on exposures to the $^{137}$Cs radioactive source and determination of the gain dependence on the high voltage for all 1600 detection channels of the polarimeter. Performance of the instrument is described in detail with respect to the dynamic range, energy resolution and temperature dependence. Gain optimization algorithms and response non-uniformity studies are also broadly discussed. Results presented below constitute important parts for development of the POLAR calibration and operation database.
△ Less
Submitted 14 March, 2017; v1 submitted 12 March, 2017;
originally announced March 2017.
-
POLAR: Final Calibration and In-Flight Performance of a Dedicated GRB Polarimeter
Authors:
M. Kole,
T. W. Bao,
T. Batsch,
T. Bernasconi,
F. Cadoux,
J. Y. Chai,
Y. W. Dong,
N. Gauvin,
W. Hajdas,
J. J. He,
M. N. Kong,
S. W. Kong,
C. Lechanoine-Leluc,
L. Li,
Z. H. Li,
J. T. Liu,
X. Liu,
R. Marcinkowski,
S. Orsi,
M. Pohl,
N. Produit,
D. Rapin,
A. Rutczynska,
D. Rybka,
H. L. Shi
, et al. (19 additional authors not shown)
Abstract:
Gamma-ray polarimetry is a new powerful tool to study the processes responsible for the emission from astrophysical sources and the environments in which this emission takes place. Few successful polarimetric measurements have however been performed thus far in the gamma-ray energy band due to the difficulties involved. POLAR is a dedicated polarimeter designed to perform high precision measuremen…
▽ More
Gamma-ray polarimetry is a new powerful tool to study the processes responsible for the emission from astrophysical sources and the environments in which this emission takes place. Few successful polarimetric measurements have however been performed thus far in the gamma-ray energy band due to the difficulties involved. POLAR is a dedicated polarimeter designed to perform high precision measurements of the polarization of the emission from gamma-ray burst in the 50-500 keV energy range. This new polarimeter is expected to detect approximately 50 gamma-ray bursts per year while performing high precision polarization measurements on approximately 10 bursts per year. The instrument was launched into lower earth orbit as part of the second Chinese space lab, the Tiangong-2, on September 15th 2016 and has been taking data successfully since being switched on one week after. The instrument uses a segmented scintillator array consisting of 1600 plastic scintillator bars, read out by 25 flat-panel multi-anode photomultipliers, to measure the Compton scattering angles of incoming photons. The small segmentation and relatively large uniform effective area allow the instrument to measure the polarization of a large number of transient events, such as gamma-ray bursts, with an unprecedented precision during its two year life-time. The final flight model underwent detailed calibration prior to launch as well as intensive space qualification tests, a summary of which will be presented in this paper. The instrument design will be discussed first followed by an overview of the on-ground tests, finally the in-orbit behavior as measured during the first weeks of the mission will be presented.
△ Less
Submitted 13 December, 2016;
originally announced December 2016.
-
eXTP -- enhanced X-ray Timing and Polarimetry Mission
Authors:
S. N. Zhang,
M. Feroci,
A. Santangelo,
Y. W. Dong,
H. Feng,
F. J. Lu,
K. Nandra,
Z. S. Wang,
S. Zhang,
E. Bozzo,
S. Brandt,
A. De Rosa,
L. J. Gou,
M. Hernanz,
M. van der Klis,
X. D. Li,
Y. Liu,
P. Orleanski,
G. Pareschi,
M. Pohl,
J. Poutanen,
J. L. Qu,
S. Schanne,
L. Stella,
P. Uttley
, et al. (160 additional authors not shown)
Abstract:
eXTP is a science mission designed to study the state of matter under extreme conditions of density, gravity and magnetism. Primary targets include isolated and binary neutron stars, strong magnetic field systems like magnetars, and stellar-mass and supermassive black holes. The mission carries a unique and unprecedented suite of state-of-the-art scientific instruments enabling for the first time…
▽ More
eXTP is a science mission designed to study the state of matter under extreme conditions of density, gravity and magnetism. Primary targets include isolated and binary neutron stars, strong magnetic field systems like magnetars, and stellar-mass and supermassive black holes. The mission carries a unique and unprecedented suite of state-of-the-art scientific instruments enabling for the first time ever the simultaneous spectral-timing-polarimetry studies of cosmic sources in the energy range from 0.5-30 keV (and beyond). Key elements of the payload are: the Spectroscopic Focusing Array (SFA) - a set of 11 X-ray optics for a total effective area of about 0.9 m^2 and 0.6 m^2 at 2 keV and 6 keV respectively, equipped with Silicon Drift Detectors offering <180 eV spectral resolution; the Large Area Detector (LAD) - a deployable set of 640 Silicon Drift Detectors, for a total effective area of about 3.4 m^2, between 6 and 10 keV, and spectral resolution <250 eV; the Polarimetry Focusing Array (PFA) - a set of 2 X-ray telescope, for a total effective area of 250 cm^2 at 2 keV, equipped with imaging gas pixel photoelectric polarimeters; the Wide Field Monitor (WFM) - a set of 3 coded mask wide field units, equipped with position-sensitive Silicon Drift Detectors, each covering a 90 degrees x 90 degrees FoV. The eXTP international consortium includes mostly major institutions of the Chinese Academy of Sciences and Universities in China, as well as major institutions in several European countries and the United States. The predecessor of eXTP, the XTP mission concept, has been selected and funded as one of the so-called background missions in the Strategic Priority Space Science Program of the Chinese Academy of Sciences since 2011. The strong European participation has significantly enhanced the scientific capabilities of eXTP. The planned launch date of the mission is earlier than 2025.
△ Less
Submitted 29 July, 2016;
originally announced July 2016.
-
Calibration of Gamma-ray Burst Polarimeter POLAR
Authors:
H. L. Xiao,
W. Hajdas,
T. W. Bao,
T. Batsch,
T. Bernasconi,
I. Cernuda,
J. Y. Chai,
Y. W. Dong,
N. Gauvin,
M. Kole,
M. N. Kong,
S. W. Kong,
L. Li,
J. T. Liu,
X. Liu,
R. Marcinkowski,
S. Orsi,
M. Pohl,
N. Produit,
D. Rapin,
A. Rutczynska,
D. Rybka,
H. L. Shi,
L. M. Song,
J. C. Sun
, et al. (11 additional authors not shown)
Abstract:
Gamma Ray Bursts (GRBs) are the strongest explosions in the universe which might be associated with creation of black holes. Magnetic field structure and burst dynamics may influence polarization of the emitted gamma-rays. Precise polarization detection can be an ultimate tool to unveil the true GRB mechanism. POLAR is a space-borne Compton scattering detector for precise measurements of the GRB p…
▽ More
Gamma Ray Bursts (GRBs) are the strongest explosions in the universe which might be associated with creation of black holes. Magnetic field structure and burst dynamics may influence polarization of the emitted gamma-rays. Precise polarization detection can be an ultimate tool to unveil the true GRB mechanism. POLAR is a space-borne Compton scattering detector for precise measurements of the GRB polarization. It consists of a 40$\times$40 array of plastic scintillator bars read out by 25 multi-anode PMTs (MaPMTs). It is scheduled to be launched into space in 2016 onboard of the Chinese space laboratory TG2. We present a dedicated methodology for POLAR calibration and some calibration results based on the combined use of the laboratory radioactive sources and polarized X-ray beams from the European Synchrotron Radiation Facility. They include calibration of the energy response, computation of the energy conversion factor vs. high voltage as well as determination of the threshold values, crosstalk contributions and polarization modulation factors.
△ Less
Submitted 9 December, 2015;
originally announced December 2015.
-
Measuring the Initial Transient: Reflected Brownian Motion
Authors:
Rob J. Wang,
Peter W. Glynn
Abstract:
We analyze the convergence to equilibrium of one-dimensional reflected Brownian motion (RBM) and compute a number of related initial transient formulae. These formulae are of interest as approximations to the initial transient for queueing systems in heavy traffic, and help us to identify settings in which initialization bias is significant. We conclude with a discussion of mean square error for R…
▽ More
We analyze the convergence to equilibrium of one-dimensional reflected Brownian motion (RBM) and compute a number of related initial transient formulae. These formulae are of interest as approximations to the initial transient for queueing systems in heavy traffic, and help us to identify settings in which initialization bias is significant. We conclude with a discussion of mean square error for RBM. Our analysis supports the view that initial transient effects for RBM and related models are typically of modest size relative to the intrinsic stochastic variability, unless one chooses an especially poor initialization.
△ Less
Submitted 21 February, 2015; v1 submitted 8 July, 2014;
originally announced July 2014.
-
Central Limit Theorems and Large Deviations for Additive Functionals of Reflecting Diffusion Processes
Authors:
Peter W. Glynn,
Rob J. Wang
Abstract:
This paper develops central limit theorems (CLT's) and large deviations results for additive functionals associated with reflecting diffusions in which the functional may include a term associated with the cumulative amount of boundary reflection that has occurred. Extending the known central limit and large deviations theory for Markov processes to include additive functionals that incorporate bo…
▽ More
This paper develops central limit theorems (CLT's) and large deviations results for additive functionals associated with reflecting diffusions in which the functional may include a term associated with the cumulative amount of boundary reflection that has occurred. Extending the known central limit and large deviations theory for Markov processes to include additive functionals that incorporate boundary reflection is important in many applications settings in which reflecting diffusions arise, including queueing theory and economics. In particular, the paper establishes the partial differential equations that must be solved in order to explicitly compute the mean and variance for the CLT, as well as the associated rate function for the large deviations principle.
△ Less
Submitted 8 July, 2014; v1 submitted 5 July, 2013;
originally announced July 2013.