-
Imaging of single barium atoms in a second matrix site in solid xenon for barium tagging in a $^{136}$Xe double beta decay experiment
Authors:
M. Yvaine,
D. Fairbank,
J. Soderstrom,
C. Taylor,
J. Stanley,
T. Walton,
C. Chambers,
A. Iverson,
W. Fairbank,
S. Al Kharusi,
A. Amy,
E. Angelico,
A. Anker,
I. J. Arnquist,
A. Atencio,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (112 additional authors not shown)
Abstract:
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform s…
▽ More
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.
△ Less
Submitted 28 June, 2024;
originally announced July 2024.
-
An integrated online radioassay data storage and analytics tool for nEXO
Authors:
R. H. M. Tsang,
A. Piepke,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
A. Atencio,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Q. Cao,
D. Cesmecioglu,
C. Chambers,
E. Chambers,
B. Chana,
S. A. Charlebois
, et al. (135 additional authors not shown)
Abstract:
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassa…
▽ More
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. This paper describes this database, explains how it functions, and discusses how it streamlines the design of the experiment.
△ Less
Submitted 20 June, 2023; v1 submitted 12 April, 2023;
originally announced April 2023.
-
Fundamental Symmetries, Neutrons, and Neutrinos (FSNN): Whitepaper for the 2023 NSAC Long Range Plan
Authors:
B. Acharya,
C. Adams,
A. A. Aleksandrova,
K. Alfonso,
P. An,
S. Baeßler,
A. B. Balantekin,
P. S. Barbeau,
F. Bellini,
V. Bellini,
R. S. Beminiwattha,
J. C. Bernauer,
T. Bhattacharya,
M. Bishof,
A. E. Bolotnikov,
P. A. Breur,
M. Brodeur,
J. P. Brodsky,
L. J. Broussard,
T. Brunner,
D. P. Burdette,
J. Caylor,
M. Chiu,
V. Cirigliano,
J. A. Clark
, et al. (154 additional authors not shown)
Abstract:
This whitepaper presents the research priorities decided on by attendees of the 2022 Town Meeting for Fundamental Symmetries, Neutrons and Neutrinos, which took place December 13-15, 2022 in Chapel Hill, NC, as part of the Nuclear Science Advisory Committee (NSAC) 2023 Long Range Planning process. A total of 275 scientists registered for the meeting. The whitepaper makes a number of explicit recom…
▽ More
This whitepaper presents the research priorities decided on by attendees of the 2022 Town Meeting for Fundamental Symmetries, Neutrons and Neutrinos, which took place December 13-15, 2022 in Chapel Hill, NC, as part of the Nuclear Science Advisory Committee (NSAC) 2023 Long Range Planning process. A total of 275 scientists registered for the meeting. The whitepaper makes a number of explicit recommendations and justifies them in detail.
△ Less
Submitted 6 April, 2023;
originally announced April 2023.
-
Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
Authors:
G. Gallina,
Y. Guan,
F. Retiere,
G. Cao,
A. Bolotnikov,
I. Kotov,
S. Rescia,
A. K. Soma,
T. Tsang,
L. Darroch,
T. Brunner,
J. Bolster,
J. R. Cohen,
T. Pinto Franco,
W. C. Gillis,
H. Peltz Smalley,
S. Thibado,
A. Pocar,
A. Bhat,
A. Jamil,
D. C. Moore,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist
, et al. (140 additional authors not shown)
Abstract:
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with…
▽ More
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay $Q$-value for the nEXO design.
△ Less
Submitted 25 November, 2022; v1 submitted 16 September, 2022;
originally announced September 2022.
-
Development of a $^{127}$Xe calibration source for nEXO
Authors:
B. G. Lenardo,
C. A. Hardy,
R. H. M. Tsang,
J. C. Nzobadila Ondze,
A. Piepke,
S. Triambak,
A. Jamil,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
B. Chana,
S. A. Charlebois
, et al. (103 additional authors not shown)
Abstract:
We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and…
▽ More
We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of $^{127}$Xe and its small $Q$-value compared to that of $^{136}$Xe $0νββ$ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.
△ Less
Submitted 12 January, 2022;
originally announced January 2022.
-
The EXO-200 detector, part II: Auxiliary Systems
Authors:
N. Ackerman,
J. Albert,
M. Auger,
D. J. Auty,
I. Badhrees,
P. S. Barbeau,
L. Bartoszek,
E. Baussan,
V. Belov,
C. Benitez-Medina,
T. Bhatta,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
R. Conley,
S. Cook,
M. Coon,
W. Craddock,
A. Craycraft,
W. Cree,
T. Daniels,
L. Darroch
, et al. (135 additional authors not shown)
Abstract:
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector op…
▽ More
The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.
△ Less
Submitted 22 October, 2021; v1 submitted 13 July, 2021;
originally announced July 2021.
-
NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity
Authors:
nEXO Collaboration,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
G. Anton,
I. J. Arnquist,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
D. Chernyak,
M. Chiu,
B. Cleveland
, et al. (136 additional authors not shown)
Abstract:
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the…
▽ More
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of $10^{28}$ years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. The effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.
△ Less
Submitted 22 February, 2022; v1 submitted 30 June, 2021;
originally announced June 2021.
-
Trace radioactive impurities in final construction materials for EXO-200
Authors:
D. S. Leonard,
D. Auty,
T. Didberidze,
R. Gornea,
P. Grinberg,
R. MacLellan,
B. Methven,
A. Piepke,
J. -L. Vuilleumier,
J. B. Albert,
G. Anton,
I. Badhrees,
P. S. Barbeau,
R. Bayerlein,
D. Beck,
V. Belov,
M. Breidenbach,
T. Brunner,
G. F. Cao,
W. R. Cen,
C. Chambers,
B. Cleveland,
M. Coon,
A. Craycraft,
W. Cree
, et al. (76 additional authors not shown)
Abstract:
We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial results from this campaign have already been reported in a 2008 paper by the EXO collaboration. Here we release the remaining data, collected since 2007, to the public. The data reported were obtained using a variety of…
▽ More
We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial results from this campaign have already been reported in a 2008 paper by the EXO collaboration. Here we release the remaining data, collected since 2007, to the public. The data reported were obtained using a variety of analytic techniques. The measurement sensitivities are among the best in the field. Construction of the EXO-200 detector has been concluded, and Phase-I data was taken from 2011 to 2014. The detector's extremely low background implicitly verifies the measurements and the analysis assumptions made during construction and reported in this paper.
△ Less
Submitted 31 March, 2017;
originally announced March 2017.
-
Observation of Two-Neutrino Double-Beta Decay in Xe-136 with EXO-200
Authors:
N. Ackerman,
B. Aharmim,
M. Auger,
D. J. Auty,
P. S. Barbeau,
K. Barry,
L. Bartoszek,
E. Beauchamp,
V. Belov,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
B. Cleveland,
R. Conley,
E. Conti,
J. Cook,
S. Cook,
A. Coppens,
I. Counts,
W. Craddock,
T. Daniels,
M. V. Danilov,
C. G. Davis,
J. Davis,
R. deVoe
, et al. (78 additional authors not shown)
Abstract:
We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, th…
▽ More
We report the observation of two-neutrino double-beta decay in Xe-136 with T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order process, predicted by the Standard Model, has been observed for several nuclei but not for Xe-136. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrino-less double-beta decay, the most sensitive probe for the existence of Majorana particles and the measurement of the neutrino mass scale.
△ Less
Submitted 22 November, 2011; v1 submitted 21 August, 2011;
originally announced August 2011.
-
Characterization of large area APDs for the EXO-200 detector
Authors:
R. Neilson,
F. LePort,
A. Pocar,
K. Kumar,
A. Odian,
C. Y. Prescott,
V. Tenev,
N. Ackerman,
D. Akimov,
M. Auger,
C. Benitez-Medina,
M. Breidenbach,
A. Burenkov,
R. Conley,
S. Cook,
R. deVoe,
M. J. Dolinski,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger,
B. Flatt,
R. Gornea,
G. Gratta,
M. Green,
C. Hall
, et al. (27 additional authors not shown)
Abstract:
EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169K - the temperature of liquid xenon. We also describe the individual characterization of more tha…
▽ More
EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169K - the temperature of liquid xenon. We also describe the individual characterization of more than 800 LAAPDs for selective installation in the EXO-200 detector.
△ Less
Submitted 13 June, 2009;
originally announced June 2009.
-
Systematic study of trace radioactive impurities in candidate construction materials for EXO-200
Authors:
D. S. Leonard,
P. Grinberg,
P. Weber,
E. Baussan,
Z. Djurcic,
G. Keefer,
A. Piepke,
A. Pocar,
J. -L. Vuilleumier,
J. -M. Vuilleumier,
D. Akimov,
A. Bellerive,
M. Bowcock,
M. Breidenbach,
A. Burenkov,
R. Conley,
W. Craddock,
M. Danilov,
R. DeVoe,
M. Dixit,
A. Dolgolenko,
I. Ekchtout,
W. Fairbank Jr.,
J. Farine,
P. Fierlinger
, et al. (32 additional authors not shown)
Abstract:
The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma…
▽ More
The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma counting, alpha counting, neutron activation analysis, and high-sensitivity mass spectrometry.
△ Less
Submitted 4 August, 2008; v1 submitted 28 September, 2007;
originally announced September 2007.
-
A linear RFQ ion trap for the Enriched Xenon Observatory
Authors:
B. Flatt,
M. Green,
J. Wodin,
R. DeVoe,
P. Fierlinger,
G. Gratta,
F. LePort,
M. Montero Diez,
R. Neilson,
K. OSullivan,
A. Pocar,
S. Waldman,
E. Baussan,
M. Breidenbach,
R. Conley,
W. Fairbank Jr.,
J. Farine,
C. Hall,
K. Hall,
D. Hallman,
C. Hargrove,
M. Hauger,
J. Hodgson,
F. Juget,
D. S. Leonard
, et al. (17 additional authors not shown)
Abstract:
The design, construction, and performance of a linear radio-frequency ion trap (RFQ) intended for use in the Enriched Xenon Observatory (EXO) are described. EXO aims to detect the neutrinoless double-beta decay of $^{136}$Xe to $^{136}$Ba. To suppress possible backgrounds EXO will complement the measurement of decay energy and, to some extent, topology of candidate events in a Xe filled detector…
▽ More
The design, construction, and performance of a linear radio-frequency ion trap (RFQ) intended for use in the Enriched Xenon Observatory (EXO) are described. EXO aims to detect the neutrinoless double-beta decay of $^{136}$Xe to $^{136}$Ba. To suppress possible backgrounds EXO will complement the measurement of decay energy and, to some extent, topology of candidate events in a Xe filled detector with the identification of the daughter nucleus ($^{136}$Ba). The ion trap described here is capable of accepting, cooling, and confining individual Ba ions extracted from the site of the candidate double-beta decay event. A single trapped ion can then be identified, with a large signal-to-noise ratio, via laser spectroscopy.
△ Less
Submitted 12 April, 2007;
originally announced April 2007.
-
Observation of single collisionally cooled trapped ions in a buffer gas
Authors:
M. Green,
J. Wodin,
R. DeVoe,
P. Fierlinger,
B. Flatt,
G. Gratta,
F. LePort,
M. Montero Diez,
R. Neilson,
K. OSullivan,
A. Pocar,
S. Waldman,
D. S. Leonard,
A. Piepke,
C. Hargrove,
D. Sinclair,
V. Strickland,
W. Fairbank Jr.,
K. Hall,
B. Mong,
M. Moe,
J. Farine,
D. Hallman,
C. Virtue,
E. Baussan
, et al. (15 additional authors not shown)
Abstract:
Individual Ba ions are trapped in a gas-filled linear ion trap and observed with a high signal-to-noise ratio by resonance fluorescence. Single-ion storage times of ~5 min (~1 min) are achieved using He (Ar) as a buffer gas at pressures in the range 8e-5 - 4e-3 torr. Trap dynamics in buffer gases are experimentally studied in the simple case of single ions. In particular, the cooling effects of…
▽ More
Individual Ba ions are trapped in a gas-filled linear ion trap and observed with a high signal-to-noise ratio by resonance fluorescence. Single-ion storage times of ~5 min (~1 min) are achieved using He (Ar) as a buffer gas at pressures in the range 8e-5 - 4e-3 torr. Trap dynamics in buffer gases are experimentally studied in the simple case of single ions. In particular, the cooling effects of light gases such as He and Ar and the destabilizing properties of heavier gases such as Xe are studied. A simple model is offered to explain the observed phenomenology.
△ Less
Submitted 5 July, 2007; v1 submitted 14 February, 2007;
originally announced February 2007.
-
A liquid xenon ionization chamber in an all-fluoropolymer vessel
Authors:
EXO Collaboration,
F. LePort,
A. Pocar,
L. Bartoszek,
R. DeVoe,
P. Fierlinger,
B. Flatt,
G. Gratta,
M. Green,
T. Koffas,
M. Montero Diez,
R. Neilson,
K. O'Sullivan,
S. Waldman,
J. Wodin,
D. Woisard,
E. Baussan,
M. Breidenbach,
R. Conley,
W. Fairbank Jr.,
J. Farine,
C. Hall,
K. Hall,
D. Hallman,
C. Hargrove
, et al. (20 additional authors not shown)
Abstract:
A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of ultra-clean fluoropolymer. We describe the advantages in terms of low radioactivity contamination, provide some details of the construction techniques, and show the energy resolution achieved with a prototype all-fluoropolymer ionization detector.
A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of ultra-clean fluoropolymer. We describe the advantages in terms of low radioactivity contamination, provide some details of the construction techniques, and show the energy resolution achieved with a prototype all-fluoropolymer ionization detector.
△ Less
Submitted 19 November, 2006;
originally announced November 2006.
-
Mobility of thorium ions in liquid xenon
Authors:
K. Wamba,
C. Hall,
M. Breidenbach,
R. Conley,
A. Odian,
C. Y. Prescott,
P. C. Rowson,
J. Sevilla,
K. Skarpaas,
R. DeVoe,
Z. Djurcic,
W. M. Fairbank Jr.,
G. Gratta,
M. Green,
K. Hall,
M. Hauger,
S-C. Jeng,
T. Koffas,
F. LePort,
D. Leonard,
J-M. Martin,
R. Neilson,
L. Ounalli,
A. Piepke,
D. Schenker
, et al. (5 additional authors not shown)
Abstract:
We present a measurement of the $^{226}$Th ion mobility in LXe at 163.0 K and 0.9 bar. The result obtained, 0.240$\pm$0.011 (stat) $\pm$0.011 (syst) cm$^{2}$/(kV-s), is compared with a popular model of ion transport.
We present a measurement of the $^{226}$Th ion mobility in LXe at 163.0 K and 0.9 bar. The result obtained, 0.240$\pm$0.011 (stat) $\pm$0.011 (syst) cm$^{2}$/(kV-s), is compared with a popular model of ion transport.
△ Less
Submitted 22 March, 2005;
originally announced March 2005.
-
Correlated Fluctuations between Luminescence and Ionization in Liquid Xenon
Authors:
E. Conti,
R. DeVoe,
G. Gratta,
T. Koffas,
S. Waldman,
J. Wodin,
D. Akimov,
G. Bower,
M. Breidenbach,
R. Conley,
M. Danilov,
Z. Djurcic,
A. Dolgolenko,
C. Hall,
A. Odian,
A. Piepke,
C. Y. Prescott,
P. C. Rowson,
K. Skarpaas,
J. -L. Vuilleumier,
K. Wamba,
O. Zeldovich
Abstract:
The ionization of liquefied noble gases by radiation is known to be accompanied by fluctuations much larger than predicted by Poisson statistics. We have studied the fluctuations of both scintillation and ionization in liquid xenon and have measured, for the first time, a strong anti-correlation between the two at a microscopic level, with coefficient $ -0.80 < ρ_{ep} < -0.60 $. This provides di…
▽ More
The ionization of liquefied noble gases by radiation is known to be accompanied by fluctuations much larger than predicted by Poisson statistics. We have studied the fluctuations of both scintillation and ionization in liquid xenon and have measured, for the first time, a strong anti-correlation between the two at a microscopic level, with coefficient $ -0.80 < ρ_{ep} < -0.60 $. This provides direct experimental evidence that electron-ion recombination is partially responsible for the anomalously large fluctuations and at the same time allows substantial improvement of calorimetric energy resolution.
△ Less
Submitted 9 March, 2003;
originally announced March 2003.