-
Cosserat Rods for Modeling Tendon-Driven Robotic Catheter Systems
Authors:
Pierre-Frederic Villard,
Thomas M. Waite,
Robert D. Howe
Abstract:
Tendon-driven robotic catheters are capable of precise execution of minimally invasive cardiac procedures including ablations and imaging. These procedures require accurate mathematical models of not only the catheter and tendons but also their interactions with surrounding tissue and vasculature in order to control the robot path and interaction. This paper presents a mechanical model of a tendon…
▽ More
Tendon-driven robotic catheters are capable of precise execution of minimally invasive cardiac procedures including ablations and imaging. These procedures require accurate mathematical models of not only the catheter and tendons but also their interactions with surrounding tissue and vasculature in order to control the robot path and interaction. This paper presents a mechanical model of a tendon-driven robotic catheter system based on Cosserat rods and integrated with a stable, implicit Euler scheme. We implement the Cosserat rod as a model for a simple catheter centerline and validate its physical accuracy against a large deformation analytical model and experimental data. The catheter model is then supplemented by adding a second Cosserat rod to model a single tendon, using penalty forces to define the constraints of the tendon-catheter system. All the model parameters are defined by the catheter properties established by the design. The combined model is validated against experimental data to confirm its physical accuracy. This model represents a new contribution to the field of robotic catheter modeling in which both the tendons and catheter are modeled by mechanical Cosserat rods and fully-validated against experimental data in the case of the single rod system.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
Assessing trade-offs among electrification and grid decarbonization in a clean energy transition: Application to New York State
Authors:
Terence Conlon,
Michael Waite,
Yuezi Wu,
Vijay Modi
Abstract:
A modeling framework is presented to investigate trade-offs among decarbonization from increased low-carbon electricity generation and electrification of heating and vehicles. The model is broadly applicable but relies on high-fidelity parameterization of existing infrastructure and anticipated electrified loads; this study applies it to New York State where detailed data is available. Trade-offs…
▽ More
A modeling framework is presented to investigate trade-offs among decarbonization from increased low-carbon electricity generation and electrification of heating and vehicles. The model is broadly applicable but relies on high-fidelity parameterization of existing infrastructure and anticipated electrified loads; this study applies it to New York State where detailed data is available. Trade-offs are investigated between end use electrification and renewable energy deployment in terms of supply costs, generation and storage capacities, renewable resource mix, and system operation. Results indicate that equivalent emissions reductions can be achieved at lower costs to the grid by prioritizing electrification with 40-70% low-carbon electricity supply instead of aiming for complete grid decarbonization. With 60% electrification and 50% low-carbon electricity, approximately 1/3 emissions reductions can be achieved at current supply costs; with only 20% electrification, 90% low-carbon electricity is required to achieve the same emissions reductions, resulting in 43% higher grid costs. In addition, three primary cost drivers are identified for a system undergoing decarbonization: (1) decreasing per-unit costs of existing infrastructure with increasing electrified demand, (2) higher in-state generation costs from low-carbon sources relative to gas-based and hydropower generation, and (3) increasing integration costs at high percentages of low-carbon electricity.
△ Less
Submitted 21 March, 2022;
originally announced March 2022.
-
Short-wave vortex instability in stratified flow
Authors:
Luke Bovard,
Michael L. Waite
Abstract:
In this paper we investigate a new instability of the Lamb-Chaplygin dipole in a stratified fluid. Through numerical linear stability analysis, a secondary peak in the growth rate emerges at vertical scales about an order of magnitude smaller than the buoyancy scale $L_{b}=U/N$ where $U$ is the characteristic velocity and $N$ is the Brunt-Väisälä frequency. This new instability exhibits a growth r…
▽ More
In this paper we investigate a new instability of the Lamb-Chaplygin dipole in a stratified fluid. Through numerical linear stability analysis, a secondary peak in the growth rate emerges at vertical scales about an order of magnitude smaller than the buoyancy scale $L_{b}=U/N$ where $U$ is the characteristic velocity and $N$ is the Brunt-Väisälä frequency. This new instability exhibits a growth rate that is similar to, and even exceeds, that of the zigzag instability, which has the characteristic length of the buoyancy scale. This instability is investigated for a wide range of Reynolds $Re=2000-20000$ and horizontal Froude numbers $F_{h}=0.05-0.2$, where $F_{h}=U/NR$, $Re=UR/ν$, $R$ is the characteristic length scale of the dipole, and $ν$ is the viscosity. A range of vertical scales is explored from above the buoyancy scale to the viscous dam** scale. Additionally, evidence is presented that the dynamics of this new instability are partially determined by the buoyancy Reynolds number, $Re_{b}=F_{h}^{2}Re$.
△ Less
Submitted 18 September, 2014; v1 submitted 26 February, 2014;
originally announced February 2014.