-
Euclid's Near-Infrared Spectrometer and Photometer ready for flight -- review of final performance
Authors:
E. Medinaceli,
L. Valenziano,
N. Auricchio,
E. Franceschi,
F. Gianotti,
P. Battaglia,
R. Farinelli,
A. Balestra,
S. Dusini,
C. Sirignano,
E. Borsato,
L. Stanco,
A. Renzi,
A. Troja,
L. Gabarra,
S. Ligori,
V. Capobianco,
L. Corcione,
D. Bonino,
G. Sirri,
L. Patrizii,
M. Tenti,
D. Di Ferdinando,
C. Valieri,
N. Mauri
, et al. (22 additional authors not shown)
Abstract:
ESA's mission Euclid, while undertaking its final integration stage, is fully qualified. Euclid will perform an extragalactic survey ($0<z<2$) by observing in the visible and near-infrared wavelength range. To detect infrared radiation, it is equipped with the Near Infrared Spectrometer and Photometer (NISP) instrument, operating in the 0.9--2 $μ$m range. In this paper, after introducing the surve…
▽ More
ESA's mission Euclid, while undertaking its final integration stage, is fully qualified. Euclid will perform an extragalactic survey ($0<z<2$) by observing in the visible and near-infrared wavelength range. To detect infrared radiation, it is equipped with the Near Infrared Spectrometer and Photometer (NISP) instrument, operating in the 0.9--2 $μ$m range. In this paper, after introducing the survey strategy, we focus our attention on the NISP Data Processing Unit's Application Software, highlighting the experimental process to obtain the final parametrization of the on-board processing of data produced by the array of 16 Teledyne HAWAII-2RG (HgCdTe) detectors. We report results from the latest ground test campaigns with the flight configuration hardware - complete optical system (Korsh anastigmat telescope), detectors array (0.56 deg$^2$ field of view), and readout systems (16 Digital Control Units and Sidecar ASICs). The performance of the on-board processing is then presented. We also describe a major issue found during the final test phase. We show how the problem was identified and solved thanks to an intensive coordinated effort of an independent review `Tiger' team, lead by ESA, and a team of NISP experts from the Euclid Consortium. An extended PLM level campaign at ambient temperature in Liège and a dedicated test campaign conducted in Marseille on the NISP EQM model eventually confirmed the resolution of the problem. Finally, we report examples of the outstanding spectrometric (using a Blue and two Red Grisms) and photometric performance of the NISP instrument, as derived from the end-to-end payload module test campaign at FOCAL 5 -- CSL; these results include the photometric Point Spread Function (PSF) determination and the spectroscopic dispersion verification.
△ Less
Submitted 6 November, 2023;
originally announced November 2023.
-
Euclid Near Infrared Spectrometer and Photometer instrument flight model presentation, performance and ground calibration results summary
Authors:
T. Maciaszek,
A. Ealet,
W. Gillard,
K. Jahnke,
R. Barbier,
E. Prieto,
W. Bon,
A. Bonnefoi,
A. Caillat,
M. Carle,
A. Costille,
F. Ducret,
C. Fabron,
B. Foulon,
J. L. Gimenez,
E. Grassi,
M. Jaquet,
D. Le Mignant,
L. Martin,
T. Pamplona,
P. Sanchez,
J. C. Clémens,
L. Caillat,
M. Niclas,
A. Secroun
, et al. (73 additional authors not shown)
Abstract:
The NISP (Near Infrared Spectrometer and Photometer) is one of the two Euclid instruments. It operates in the near-IR spectral region (950-2020nm) as a photometer and spectrometer. The instrument is composed of: a cold (135 K) optomechanical subsystem consisting of a Silicon carbide structure, an optical assembly, a filter wheel mechanism, a grism wheel mechanism, a calibration unit, and a thermal…
▽ More
The NISP (Near Infrared Spectrometer and Photometer) is one of the two Euclid instruments. It operates in the near-IR spectral region (950-2020nm) as a photometer and spectrometer. The instrument is composed of: a cold (135 K) optomechanical subsystem consisting of a Silicon carbide structure, an optical assembly, a filter wheel mechanism, a grism wheel mechanism, a calibration unit, and a thermal control system, a detection system based on a mosaic of 16 H2RG with their front-end readout electronic, and a warm electronic system (290 K) composed of a data processing / detector control unit and of an instrument control unit that interfaces with the spacecraft via a 1553 bus for command and control and via Spacewire links for science data.
This paper presents: the final architecture of the flight model instrument and subsystems, and the performance and the ground calibration measurement done at NISP level and at Euclid Payload Module level at operational cold temperature.
△ Less
Submitted 18 October, 2022;
originally announced October 2022.
-
Properties and characteristics of the WFIRST H4RG-10 detectors
Authors:
Gregory Mosby, Jr.,
Bernard J. Rauscher,
Chris Bennett,
Edward . S. Cheng,
Stephanie Cheung,
Analia Cillis,
David Content,
Dave Cottingham,
Roger Foltz,
John Gygax,
Robert J. Hill,
Jeffrey W. Kruk,
Jon Mah,
Lane Meier,
Chris Merchant,
Laddawan Miko,
Eric C. Piquette,
Augustyn Waczynski,
Yiting Wen
Abstract:
The Wide-Field Infrared Survey Telescope (WFIRST) will answer fundamental questions about the evolution of dark energy over time and expand the catalog of known exoplanets into new regions of parameter space. Using a Hubble-sized mirror and 18 newly developed HgCdTe 4K x 4K photodiode arrays (H4RG-10), WFIRST will measure the positions and shapes of hundreds of millions of galaxies, the light curv…
▽ More
The Wide-Field Infrared Survey Telescope (WFIRST) will answer fundamental questions about the evolution of dark energy over time and expand the catalog of known exoplanets into new regions of parameter space. Using a Hubble-sized mirror and 18 newly developed HgCdTe 4K x 4K photodiode arrays (H4RG-10), WFIRST will measure the positions and shapes of hundreds of millions of galaxies, the light curves of thousands of supernovae, and the microlensing signals of over a thousand exoplanets toward the bulge of the Galaxy. These measurements require unprecedented sensitivity and characterization of the Wide Field Instrument (WFI), particularly its detectors. The WFIRST project undertook an extensive detector development program to create focal plane arrays that meet these science requirements. These prototype detectors have been characterized and their performance demonstrated in a relevant space-like environment (thermal vacuum, vibration, acoustic, and radiation testing), advancing the H4RG-10's technology readiness level (TRL) to TRL-6. We present the performance characteristics of these TRL-6 demonstration devices.
△ Less
Submitted 1 May, 2020;
originally announced May 2020.
-
Inter-Pixel Crosstalk in Teledyne Imaging Sensors (TIS) H4RG-10 Detectors
Authors:
R. P. Dudik,
M. Jordan,
B. N. Dorland,
D. Veillette,
A. Waczynski,
B. Lane,
M. Loose,
E. Kan,
J. Waterman,
S. Pravdo
Abstract:
CMOS-hybrid arrays have recently surfaced as competitive optical detectors for use in ground- and space-based astronomy. One source of error in these detectors that does not appear in more traditional CCD arrays is the inter-pixel capacitance component of crosstalk. In this paper we use a single pixel reset method to model inter-pixel capacitance (IPC). We combine this IPC model with a model for c…
▽ More
CMOS-hybrid arrays have recently surfaced as competitive optical detectors for use in ground- and space-based astronomy. One source of error in these detectors that does not appear in more traditional CCD arrays is the inter-pixel capacitance component of crosstalk. In this paper we use a single pixel reset method to model inter-pixel capacitance (IPC). We combine this IPC model with a model for charge diffusion to estimate the total crosstalk on H4RG arrays. Finally, we compare our model results to Fe55 data obtained using an astrometric camera built to test the H4RG-B0 generation detectors.
△ Less
Submitted 2 April, 2012; v1 submitted 26 March, 2012;
originally announced March 2012.
-
The ^{55}Fe X-ray Energy Response of Mercury Cadmium Telluride Near-Infrared Detector Arrays
Authors:
Ori D. Fox,
Augustyn Waczynski,
Yiting Wen,
Roger D. Foltz,
Robert J. Hill,
Randy A. Kimble,
Eliot Malumuth,
Bernard J. Rauscher
Abstract:
A technique involving ^{55}Fe X-rays provides a straightforward method to measure the response of a detector. The detector's response can lead directly to a calculation of the conversion gain (e^- ADU^{-1}), as well as aid detector design and performance studies. We calibrate the ^{55}Fe X-ray energy response and pair production energy of HgCdTe using 8 HST WFC3 1.7 \micron flight grade detector…
▽ More
A technique involving ^{55}Fe X-rays provides a straightforward method to measure the response of a detector. The detector's response can lead directly to a calculation of the conversion gain (e^- ADU^{-1}), as well as aid detector design and performance studies. We calibrate the ^{55}Fe X-ray energy response and pair production energy of HgCdTe using 8 HST WFC3 1.7 \micron flight grade detectors. The results show that each K$α$ X-ray generates 2273 \pm 137 electrons, which corresponds to a pair-production energy of 2.61 \pm 0.16 eV. The uncertainties are dominated by our knowledge of the conversion gain. In future studies, we plan to eliminate this uncertainty by directly measuring conversion gain at very low light levels.
△ Less
Submitted 2 June, 2009;
originally announced June 2009.