-
ML-Powered FPGA-based Real-Time Quantum State Discrimination Enabling Mid-circuit Measurements
Authors:
Neel R. Vora,
Yilun Xu,
Akel Hashim,
Neelay Fruitwala,
Ho Nam Nguyen,
Haoran Liao,
Jan Balewski,
Abhi Rajagopala,
Kasra Nowrouzi,
Qing Ji,
K. Birgitta Whaley,
Irfan Siddiqi,
Phuc Nguyen,
Gang Huang
Abstract:
Similar to reading the transistor state in classical computers, identifying the quantum bit (qubit) state is a fundamental operation to translate quantum information. However, identifying quantum state has been the slowest and most susceptible to errors operation on superconducting quantum processors. Most existing state discrimination algorithms have only been implemented and optimized "after the…
▽ More
Similar to reading the transistor state in classical computers, identifying the quantum bit (qubit) state is a fundamental operation to translate quantum information. However, identifying quantum state has been the slowest and most susceptible to errors operation on superconducting quantum processors. Most existing state discrimination algorithms have only been implemented and optimized "after the fact" - using offline data transferred from control circuits to host computers. Real-time state discrimination is not possible because a superconducting quantum state only survives for a few hundred us, which is much shorter than the communication delay between the readout circuit and the host computer (i.e., tens of ms). Mid-circuit measurement (MCM), where measurements are conducted on qubits at intermediate stages within a quantum circuit rather than solely at the end, represents an advanced technique for qubit reuse. For MCM necessitating single-shot readout, it is imperative to employ an in-situ technique for state discrimination with low latency and high accuracy. This paper introduces QubiCML, a field-programmable gate array (FPGA) based system for real-time state discrimination enabling MCM - the ability to measure the state at the control circuit before/without transferring data to a host computer. A multi-layer neural network has been designed and deployed on an FPGA to ensure accurate in-situ state discrimination. For the first time, ML-powered quantum state discrimination has been implemented on a radio frequency system-on-chip FPGA platform. The deployed lightweight network on the FPGA only takes 54 ns to complete each inference. We evaluated QubiCML's performance on superconducting quantum processors and obtained an average accuracy of 98.5% with only 500 ns readout. QubiCML has the potential to be the standard real-time state discrimination method for the quantum community.
△ Less
Submitted 28 June, 2024; v1 submitted 26 June, 2024;
originally announced June 2024.
-
QubiCSV: An Open-Source Data Storage and Visualization Platform for Collaborative Qubit Control
Authors:
Devanshu Brahmbhatt,
Yilun Xu,
Neel Vora,
Larry Chen,
Neelay Fruitwala,
Gang Huang,
Qing Ji,
Phuc Nguyen
Abstract:
Develo** collaborative research platforms for quantum bit control is crucial for driving innovation in the field, as they enable the exchange of ideas, data, and implementation to achieve more impactful outcomes. Furthermore, considering the high costs associated with quantum experimental setups, collaborative environments are vital for maximizing resource utilization efficiently. However, the l…
▽ More
Develo** collaborative research platforms for quantum bit control is crucial for driving innovation in the field, as they enable the exchange of ideas, data, and implementation to achieve more impactful outcomes. Furthermore, considering the high costs associated with quantum experimental setups, collaborative environments are vital for maximizing resource utilization efficiently. However, the lack of dedicated data management platforms presents a significant obstacle to progress, highlighting the necessity for essential assistive tools tailored for this purpose. Current qubit control systems are unable to handle complicated management of extensive calibration data and do not support effectively visualizing intricate quantum experiment outcomes. In this paper, we introduce QubiCSV (Qubit Control Storage and Visualization), a platform specifically designed to meet the demands of quantum computing research, focusing on the storage and analysis of calibration and characterization data in qubit control systems. As an open-source tool, QubiCSV facilitates efficient data management of quantum computing, providing data versioning capabilities for data storage and allowing researchers and programmers to interact with qubits in real time. The insightful visualization are developed to interpret complex quantum experiments and optimize qubit performance. QubiCSV not only streamlines the handling of qubit control system data but also improves the user experience with intuitive visualization features, making it a valuable asset for researchers in the quantum computing domain.
△ Less
Submitted 6 March, 2024;
originally announced March 2024.
-
An Unobtrusive and Lightweight Ear-worn System for Continuous Epileptic Seizure Detection
Authors:
Abdul Aziz,
Nhat Pham,
Neel Vora,
Cody Reynolds,
Jaime Lehnen,
Pooja Venkatesh,
Zhuoran Yao,
Jay Harvey,
Tam Vu,
Kan Ding,
Phuc Nguyen
Abstract:
Epilepsy is one of the most common neurological diseases globally, affecting around 50 million people worldwide. Fortunately, up to 70 percent of people with epilepsy could live seizure-free if properly diagnosed and treated, and a reliable technique to monitor the onset of seizures could improve the quality of life of patients who are constantly facing the fear of random seizure attacks. The scal…
▽ More
Epilepsy is one of the most common neurological diseases globally, affecting around 50 million people worldwide. Fortunately, up to 70 percent of people with epilepsy could live seizure-free if properly diagnosed and treated, and a reliable technique to monitor the onset of seizures could improve the quality of life of patients who are constantly facing the fear of random seizure attacks. The scalp-based EEG test, despite being the gold standard for diagnosing epilepsy, is costly, necessitates hospitalization, demands skilled professionals for operation, and is discomforting for users. In this paper, we propose EarSD, a novel lightweight, unobtrusive, and socially acceptable ear-worn system to detect epileptic seizure onsets by measuring the physiological signals from behind the user's ears. EarSD includes an integrated custom-built sensing, computing, and communication PCB to collect and amplify the signals of interest, remove the noises caused by motion artifacts and environmental impacts, and stream the data wirelessly to the computer or mobile phone nearby, where data are uploaded to the host computer for further processing. We conducted both in-lab and in-hospital experiments with epileptic seizure patients who were hospitalized for seizure studies. The preliminary results confirm that EarSD can detect seizures with up to 95.3 percent accuracy by just using classical machine learning algorithms.
△ Less
Submitted 1 January, 2024;
originally announced January 2024.
-
Real-Time Diagnostic Integrity Meets Efficiency: A Novel Platform-Agnostic Architecture for Physiological Signal Compression
Authors:
Neel R Vora,
Amir Hajighasemi,
Cody T. Reynolds,
Amirmohammad Radmehr,
Mohamed Mohamed,
Jillur Rahman Saurav,
Abdul Aziz,
Jai Prakash Veerla,
Mohammad S Nasr,
Hayden Lotspeich,
Partha Sai Guttikonda,
Thuong Pham,
Aarti Darji,
Parisa Boodaghi Malidarreh,
Helen H Shang,
Jay Harvey,
Kan Ding,
Phuc Nguyen,
Jacob M Luber
Abstract:
Head-based signals such as EEG, EMG, EOG, and ECG collected by wearable systems will play a pivotal role in clinical diagnosis, monitoring, and treatment of important brain disorder diseases.
However, the real-time transmission of the significant corpus physiological signals over extended periods consumes substantial power and time, limiting the viability of battery-dependent physiological monit…
▽ More
Head-based signals such as EEG, EMG, EOG, and ECG collected by wearable systems will play a pivotal role in clinical diagnosis, monitoring, and treatment of important brain disorder diseases.
However, the real-time transmission of the significant corpus physiological signals over extended periods consumes substantial power and time, limiting the viability of battery-dependent physiological monitoring wearables.
This paper presents a novel deep-learning framework employing a variational autoencoder (VAE) for physiological signal compression to reduce wearables' computational complexity and energy consumption.
Our approach achieves an impressive compression ratio of 1:293 specifically for spectrogram data, surpassing state-of-the-art compression techniques such as JPEG2000, H.264, Direct Cosine Transform (DCT), and Huffman Encoding, which do not excel in handling physiological signals.
We validate the efficacy of the compressed algorithms using collected physiological signals from real patients in the Hospital and deploy the solution on commonly used embedded AI chips (i.e., ARM Cortex V8 and Jetson Nano). The proposed framework achieves a 91% seizure detection accuracy using XGBoost, confirming the approach's reliability, practicality, and scalability.
△ Less
Submitted 4 January, 2024; v1 submitted 19 December, 2023;
originally announced December 2023.