-
Prototype of the SST-1M Telescope Structure for the Cherenkov Telescope Array
Authors:
J. Niemiec,
W. Bilnik,
J. Błocki,
L. Bogacz,
J. Borkowski,
T . Bulik,
F. Cadoux,
A. Christov,
M. Curyło,
D. della Volpe,
M. Dyrda,
Y. Favre,
A. Frankowski,
Ł. Grudnik,
M. Grudzińska,
M. Heller,
B. Idźkowski,
M. Jamrozy,
M. Janiak,
J. Kasperek,
K. Lalik,
E. Lyard,
E. Mach,
D. Mandat,
A. Marszałek
, et al. (27 additional authors not shown)
Abstract:
A single-mirror small-size (SST-1M) Davies-Cotton telescope with a dish diameter of 4 m has been built by a consortium of Polish and Swiss institutions as a prototype for one of the proposed small-size telescopes for the southern observatory of the Cherenkov Telescope Array (CTA). The design represents a very simple, reliable, and cheap solution. The mechanical structure prototype with its drive s…
▽ More
A single-mirror small-size (SST-1M) Davies-Cotton telescope with a dish diameter of 4 m has been built by a consortium of Polish and Swiss institutions as a prototype for one of the proposed small-size telescopes for the southern observatory of the Cherenkov Telescope Array (CTA). The design represents a very simple, reliable, and cheap solution. The mechanical structure prototype with its drive system is now being tested at the Institute of Nuclear Physics PAS in Krakow. Here we present the design of the prototype and results of the performance tests of the structure and the drive and control system.
△ Less
Submitted 6 September, 2015;
originally announced September 2015.
-
Using muon rings for the optical throughput calibration of the SST-1M prototype for the Cherenkov Telescope Array
Authors:
S. Toscano,
E. Prandini,
W. Bilnik,
J. Błocki,
L. Bogacz,
T. Bulik,
F. Cadoux,
A. Christov,
M. Curyło,
D. della Volpe,
M. Dyrda,
Y. Favre,
A. Frankowski,
Ł. Grudnik,
M. Grudzińska,
M. Heller,
B. Idźkowski,
M. Jamrozy,
M. Janiak,
J. Kasperek,
K. Lalik,
E. Lyard,
E. Mach,
D. Mandat,
A. Marszałek
, et al. (26 additional authors not shown)
Abstract:
Imaging Atmospheric Cherenkov Telescopes (IACTs) are ground-based instruments devoted to the study of very high energy gamma-rays coming from space. The detection technique consists of observing images created by the Cherenkov light emitted when gamma rays, or more generally cosmic rays, propagate through the atmosphere. While in the case of protons or gamma-rays the images present a filled and mo…
▽ More
Imaging Atmospheric Cherenkov Telescopes (IACTs) are ground-based instruments devoted to the study of very high energy gamma-rays coming from space. The detection technique consists of observing images created by the Cherenkov light emitted when gamma rays, or more generally cosmic rays, propagate through the atmosphere. While in the case of protons or gamma-rays the images present a filled and more or less elongated shape, energetic muons penetrating the atmosphere are visualised as characteristic circular rings or arcs. A relatively simple analysis of the ring images allows the reconstruction of all the relevant parameters of the detected muons, such as the energy, the impact parameter, and the incoming direction, with the final aim to use them to calibrate the total optical throughput of the given IACT telescope. We present the results of preliminary studies on the use of images created by muons as optical throughput calibrators of the single mirror small size telescope prototype SST-1M proposed for the Cherenkov Telescope Array.
△ Less
Submitted 1 September, 2015;
originally announced September 2015.
-
Software design for the control system for Small-Size Telescopes with single-mirror of the Cherenkov Telescope Array
Authors:
A. Porcelli,
W. Bilnik,
J. Błocki,
L. Bogacz,
J. Borkowski,
T. Bulik,
F. Cadoux,
A. Christov,
M. Curyło,
D. della Volpe,
M. Dyrda,
Y. Favre,
A. Frankowski,
Ł. Grudnik,
M. Grudzińska,
M. Heller,
B. Idźkowski,
M. Jamrozy,
M. Janiak,
J. Kasperek,
K. Lalik,
E. Lyard,
E. Mach,
D. Mandat,
A. Marszałek
, et al. (28 additional authors not shown)
Abstract:
The Small-Size Telescope with single-mirror (SST-1M) is a 4 m Davies-Cotton telescope and is among the proposed telescope designs for the Cherenkov Telescope Array (CTA). It is conceived to provide the high-energy ($>$ few TeV) coverage. The SST-1M contains proven technology for the telescope structure and innovative electronics and photosensors for the camera. Its design is meant to be simple, lo…
▽ More
The Small-Size Telescope with single-mirror (SST-1M) is a 4 m Davies-Cotton telescope and is among the proposed telescope designs for the Cherenkov Telescope Array (CTA). It is conceived to provide the high-energy ($>$ few TeV) coverage. The SST-1M contains proven technology for the telescope structure and innovative electronics and photosensors for the camera. Its design is meant to be simple, low-budget and easy-to-build industrially.
Each device subsystem of an SST-1M telescope is made visible to CTA through a dedicated industrial standard server. The software is being developed in collaboration with the CTA Medium-Size Telescopes to ensure compatibility and uniformity of the array control. Early operations of the SST-1M prototype will be performed with a subset of the CTA central array control system based on the Alma Common Software (ACS). The triggered event data are time stamped, formatted and finally transmitted to the CTA data acquisition.
The software system developed to control the devices of an SST-1M telescope is described, as well as the interface between the telescope abstraction to the CTA central control and the data acquisition system.
△ Less
Submitted 29 August, 2015;
originally announced August 2015.
-
Development of the optical system for the SST-1M telescope of the Cherenkov Telescope Array observatory
Authors:
K. Seweryn,
W. Bilnik,
J. Błocki,
L. Bogacz,
T. Bulik,
F. Cadoux,
A. Christov,
M. Chruślińska,
M. Curyło,
D. della Volpe,
M. Dyrda,
Y. Favre,
A. Frankowski,
Ł. Grudnik,
M. Grudzińska,
M. Heller,
B. Idźkowski,
M. Jamrozy,
M. Janiak,
J. Kasperek,
K. Lalik,
E. Lyard,
E. Mach,
D. Mandat,
A. Marszałek
, et al. (36 additional authors not shown)
Abstract:
The prototype of a Davies-Cotton small size telescope (SST-1M) has been designed and developed by a consortium of Polish and Swiss institutions and proposed for the Cherenkov Telescope Array (CTA) observatory. The main purpose of the optical system is to focus the Cherenkov light emitted by extensive air showers in the atmosphere onto the focal plane detectors. The main component of the system is…
▽ More
The prototype of a Davies-Cotton small size telescope (SST-1M) has been designed and developed by a consortium of Polish and Swiss institutions and proposed for the Cherenkov Telescope Array (CTA) observatory. The main purpose of the optical system is to focus the Cherenkov light emitted by extensive air showers in the atmosphere onto the focal plane detectors. The main component of the system is a dish consisting of 18 hexagonal mirrors with a total effective collection area of 6.47 m2 (including the shadowing and estimated mirror reflectivity). Such a solution was chosen taking into account the analysis of the Cherenkov light propagation and based on optical simulations. The proper curvature and stability of the dish is ensured by the mirror alignment system and the isostatic interface to the telescope structure. Here we present the design of the optical subsystem together with the performance measurements of its components.
△ Less
Submitted 27 August, 2015;
originally announced August 2015.
-
Performance of the SST-1M telescope for the Cherenkov Telescope Array observatory
Authors:
R. Moderski,
W. Bilnik,
J. Błocki,
L. Bogacz,
T. Bulik,
F. Cadoux,
A. Christov,
M. Chruślińska,
M. Curyło,
D. della Volpe,
M. Dyrda,
Y. Favre,
A. Frankowski,
Ł. Grudnik,
M. Grudzińska,
M. Heller,
B. Idźkowski,
M. Jamrozy,
M. Janiak,
J. Kasperek,
K. Lalik,
E. Lyard,
E. Mach,
D. Mandat,
A. Marszałek
, et al. (29 additional authors not shown)
Abstract:
The single mirror small-size telescope (SST-1M) is one of the telescope projects being proposed for the Cherenkov Telescope Array observatory by a sub-consortium of Polish and Swiss institutions. The SST-1M prototype structure is currently being constructed at the Institute of Nuclear Physics in Cracow, Poland, while the camera will be assembled at the University of Geneva, Switzerland. This proto…
▽ More
The single mirror small-size telescope (SST-1M) is one of the telescope projects being proposed for the Cherenkov Telescope Array observatory by a sub-consortium of Polish and Swiss institutions. The SST-1M prototype structure is currently being constructed at the Institute of Nuclear Physics in Cracow, Poland, while the camera will be assembled at the University of Geneva, Switzerland. This prototype enables measurements of parameters having a decisive influence on the telescope performance. We present results of numerical simulations of the SST-1M performance based on such measurements. The telescope effective area, the expected trigger rates and the optical point spread function are calculated.
△ Less
Submitted 26 August, 2015;
originally announced August 2015.
-
The SST-1M camera for the Cherenkov Telescope Array
Authors:
E. J. Schioppa,
F. Cadoux,
A. Christov,
D. della Volpe,
Y. Favre,
M. Heller,
T. Montaruli,
A. Porcelli,
M. Rameez,
I. Troyano Pujadas,
W. Bilnik,
J. Blocki,
L. Bogacz,
T. Bulik,
M. Curylo,
M. Dyrda,
A. Frankowski,
L. Grudniki,
M. Grudzinska,
B. Idzkowski,
M. Jamrozy,
M. Janiak,
J. Kasperek,
K. Lalik,
E. Lyard
, et al. (26 additional authors not shown)
Abstract:
The prototype camera of the single-mirror Small Size Telescopes (SST-1M) proposed for the Cherenkov Telescope Array (CTA) project has been designed to be very compact and to deliver high performance over thirty years of operation. The camera is composed of an hexagonal photo-detection plane made of custom designed large area hexagonal silicon photomultipliers and a high throughput, highly configur…
▽ More
The prototype camera of the single-mirror Small Size Telescopes (SST-1M) proposed for the Cherenkov Telescope Array (CTA) project has been designed to be very compact and to deliver high performance over thirty years of operation. The camera is composed of an hexagonal photo-detection plane made of custom designed large area hexagonal silicon photomultipliers and a high throughput, highly configurable, fully digital readout and trigger system (DigiCam). The camera will be installed on the telescope structure at the H. Niewodnicza{ń}ski institute of Nuclear Physics in Krakow in fall 2015. In this contribution, we review the steps that led to the development of the innovative photo-detection plane and readout electronics, and we describe the test and calibration strategy adopted.
△ Less
Submitted 26 August, 2015;
originally announced August 2015.
-
Camera calibration strategy of the SST-1M prototype of the Cherenokov Telescope Array
Authors:
E. Prandini,
M. Heller,
E. Lyard,
E. jr. Schioppa,
A. Neronov,
W. Bilnik,
J. Błocki,
L. Bogacz,
T. Bulik,
F. Cadoux,
A. Christov,
M. Curyło,
D. della Volpe,
M. Dyrda,
Y. Favre,
A. Frankowski,
Ł. Grudnik,
M. Grudzińska,
B. Idźkowski,
M. Jamrozy,
M. Janiak,
J. Kasperek,
K. Lalik,
E. Mach,
D. Mandat
, et al. (26 additional authors not shown)
Abstract:
The SST-1M telescope is one of the prototypes under construction proposed to be part of the future Cherenkov Telescope Array. It uses a standard Davis-Cotton design for the optics and telescope structure, with a dish diameter of 4 meters and a large field-of-view of 9 degrees.
The innovative camera design is composed of a photo-detection plane with 1296 pixels including entrance window, light co…
▽ More
The SST-1M telescope is one of the prototypes under construction proposed to be part of the future Cherenkov Telescope Array. It uses a standard Davis-Cotton design for the optics and telescope structure, with a dish diameter of 4 meters and a large field-of-view of 9 degrees.
The innovative camera design is composed of a photo-detection plane with 1296 pixels including entrance window, light concentrators, Silicon Photomultipliers (SiPMs), and pre-amplifier stages together with a fully digital readout and trigger electronics, DigiCam.
In this contribution we give a general description of the analysis chain designed for the SST-1M prototype. In particular we focus on the calibration strategy used to convert the SiPM signals registered by DigiCam to the quantities needed for Cherenkov image analysis. The calibration is based on an online feedback system to stabilize the gain of the SiPMs, as well as dedicated events (dark count, pedestal, and light flasher events) to be taken during the normal operation of the prototype.
△ Less
Submitted 26 August, 2015;
originally announced August 2015.
-
DigiCam - Fully Digital Compact Read-out and Trigger Electronics for the SST-1M Telescope proposed for the Cherenkov Telescope Array
Authors:
P. Rajda,
K. Ziętara,
W. Bilnik,
J. Błocki,
L. Bogacz,
T. Bulik,
F. Cadoux,
A. Christov,
M. Curyło,
D. della Volpe,
M. Dyrda,
Y. Favre,
A. Frankowski,
Ł. Grudnik,
M. Grudzińska,
M. Heller,
B. Idźkowski,
M. Jamrozy,
M. Janiak,
J. Kasperek,
K. Lalik,
E. Lyard,
E. Mach,
D. Mandat,
A. Marszałek
, et al. (26 additional authors not shown)
Abstract:
The SST-1M is one of three prototype small-sized telescope designs proposed for the Cherenkov Telescope Array, and is built by a consortium of Polish and Swiss institutions. The SST-1M will operate with DigiCam - an innovative, compact camera with fully digital read-out and trigger electronics. A high level of integration will be achieved by massively deploying state-of-the-art multi-gigabit trans…
▽ More
The SST-1M is one of three prototype small-sized telescope designs proposed for the Cherenkov Telescope Array, and is built by a consortium of Polish and Swiss institutions. The SST-1M will operate with DigiCam - an innovative, compact camera with fully digital read-out and trigger electronics. A high level of integration will be achieved by massively deploying state-of-the-art multi-gigabit transmission channels, beginning from the ADC flash converters, through the internal data and trigger signals transmission over backplanes and cables, to the camera's server link. Such an approach makes it possible to design the camera to fit the size and weight requirements of the SST-1M exactly, and provide low power consumption, high reliability and long lifetime. The structure of the digital electronics will be presented, along with main physical building blocks and the internal architecture of FPGA functional subsystems.
△ Less
Submitted 25 August, 2015;
originally announced August 2015.
-
CTA Contributions to the 34th International Cosmic Ray Conference (ICRC2015)
Authors:
The CTA Consortium,
:,
A. Abchiche,
U. Abeysekara,
Ó. Abril,
F. Acero,
B. S. Acharya,
M. Actis,
G. Agnetta,
J. A. Aguilar,
F. Aharonian,
A. Akhperjanian,
A. Albert,
M. Alcubierre,
R. Alfaro,
E. Aliu,
A. J. Allafort,
D. Allan,
I. Allekotte,
R. Aloisio,
J. -P. Amans,
E. Amato,
L. Ambrogi,
G. Ambrosi,
M. Ambrosio
, et al. (1290 additional authors not shown)
Abstract:
List of contributions from the CTA Consortium presented at the 34th International Cosmic Ray Conference, 30 July - 6 August 2015, The Hague, The Netherlands.
List of contributions from the CTA Consortium presented at the 34th International Cosmic Ray Conference, 30 July - 6 August 2015, The Hague, The Netherlands.
△ Less
Submitted 11 September, 2015; v1 submitted 24 August, 2015;
originally announced August 2015.
-
${\cal D}$-deformed harmonic oscillators
Authors:
F. Bagarello,
F. Gargano,
D. Volpe
Abstract:
We analyze systematically several deformations arising from two-dimensional harmonic oscillators which can be described in terms of $\cal{D}$-pseudo bosons. They all give rise to exactly solvable models, described by non self-adjoint hamiltonians whose eigenvalues and eigenvectors can be found adopting the quite general framework of the so-called $\cal{D}$-pseudo bosons. In particular, we show tha…
▽ More
We analyze systematically several deformations arising from two-dimensional harmonic oscillators which can be described in terms of $\cal{D}$-pseudo bosons. They all give rise to exactly solvable models, described by non self-adjoint hamiltonians whose eigenvalues and eigenvectors can be found adopting the quite general framework of the so-called $\cal{D}$-pseudo bosons. In particular, we show that several models previously introduced in the literature perfectly fit into this scheme.
△ Less
Submitted 30 December, 2014;
originally announced December 2014.
-
Design, optimization and characterization of the light concentrators of the single-mirror small size telescopes of the Cherenkov Telescope Array
Authors:
J. A. Aguilar,
A. Basili,
V. Boccone,
F. Cadoux,
A. Christov,
D. della Volpe,
T. Montaruli,
L. Platos,
M. Rameez
Abstract:
The focal-plane camera of $γ$-ray telescopes frequently uses light concentrators in front of light sensors. The purpose of these concentrators is to increase the effective area of the camera as well as to reduce the stray light coming at large incident angles. These light concentrators are usually based on the Winston cone design. In this contribution we present the design of an hexagonal hollow l…
▽ More
The focal-plane camera of $γ$-ray telescopes frequently uses light concentrators in front of light sensors. The purpose of these concentrators is to increase the effective area of the camera as well as to reduce the stray light coming at large incident angles. These light concentrators are usually based on the Winston cone design. In this contribution we present the design of an hexagonal hollow light concentrator with a lateral profile optimized using a cubic Bézier function to achieve a higher collection efficiency in the angular region of interest. The design presented here is optimized for a Davies-Cotton telescope with primary mirror of about 4 meters of diameter and focal length of 5.6 m. The described concentrators are part of an innovative camera made up of silicon-photomultipliers sensors, although a similar approach can be used for other sizes of single-mirror telescopes with different camera sensors, including photomultipliers. The challenge of our approach is to achieve a cost-effective design suitable for standard industrial productions of both the plastic concentrator substrate and the reflective coating. At the same time we maximize the optical performance. In this paper we also describe the optical set-up to measure the absolute collection efficiency of the light guides and demonstrate our good understanding of the measured data using a professional light tracing simulation.
△ Less
Submitted 10 April, 2014;
originally announced April 2014.
-
CTA contributions to the 33rd International Cosmic Ray Conference (ICRC2013)
Authors:
The CTA Consortium,
:,
O. Abril,
B. S. Acharya,
M. Actis,
G. Agnetta,
J. A. Aguilar,
F. Aharonian,
M. Ajello,
A. Akhperjanian,
M. Alcubierre,
J. Aleksic,
R. Alfaro,
E. Aliu,
A. J. Allafort,
D. Allan,
I. Allekotte,
R. Aloisio,
E. Amato,
G. Ambrosi,
M. Ambrosio,
J. Anderson,
E. O. Angüner,
L. A. Antonelli,
V. Antonuccio
, et al. (1082 additional authors not shown)
Abstract:
Compilation of CTA contributions to the proceedings of the 33rd International Cosmic Ray Conference (ICRC2013), which took place in 2-9 July, 2013, in Rio de Janeiro, Brazil
Compilation of CTA contributions to the proceedings of the 33rd International Cosmic Ray Conference (ICRC2013), which took place in 2-9 July, 2013, in Rio de Janeiro, Brazil
△ Less
Submitted 29 July, 2013; v1 submitted 8 July, 2013;
originally announced July 2013.
-
Expected Performance of the ATLAS Experiment - Detector, Trigger and Physics
Authors:
The ATLAS Collaboration,
G. Aad,
E. Abat,
B. Abbott,
J. Abdallah,
A. A. Abdelalim,
A. Abdesselam,
O. Abdinov,
B. Abi,
M. Abolins,
H. Abramowicz,
B. S. Acharya,
D. L. Adams,
T. N. Addy,
C. Adorisio,
P. Adragna,
T. Adye,
J. A. Aguilar-Saavedra,
M. Aharrouche,
S. P. Ahlen,
F. Ahles,
A. Ahmad,
H. Ahmed,
G. Aielli,
T. Akdogan
, et al. (2587 additional authors not shown)
Abstract:
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on…
▽ More
A detailed study is presented of the expected performance of the ATLAS detector. The reconstruction of tracks, leptons, photons, missing energy and jets is investigated, together with the performance of b-tagging and the trigger. The physics potential for a variety of interesting physics processes, within the Standard Model and beyond, is examined. The study comprises a series of notes based on simulations of the detector and physics processes, with particular emphasis given to the data expected from the first years of operation of the LHC at CERN.
△ Less
Submitted 14 August, 2009; v1 submitted 28 December, 2008;
originally announced January 2009.
-
Ageing test of the ATLAS RPCs at X5-GIF
Authors:
G. Aielli,
M. Alviggi,
V. Ammosov,
M. Biglietti,
P. Camarri,
V. Canale,
M. Caprio,
R. Cardarelli,
G. Carlino,
G. Cataldi,
G. Chiodini,
F. Conventi,
R. de Asmundis,
M. Della Pietra,
D. Della Volpe,
A. Di Ciaccio,
A. Di Simone,
L. Di Stante,
E. Gorini,
F. Grancagnolo,
P. Iengo,
B. Liberti,
A. Nisati,
Fr. Pastore,
E. Pastori
, et al. (10 additional authors not shown)
Abstract:
An ageing test of three ATLAS production RPC stations is in course at X5-GIF, the CERN irradiation facility. The chamber efficiencies are monitored using cosmic rays triggered by a scintillator hodoscope. Higher statistics measurements are made when the X5 muon beam is available. We report here the measurements of the efficiency versus operating voltage at different source intensities, up to a m…
▽ More
An ageing test of three ATLAS production RPC stations is in course at X5-GIF, the CERN irradiation facility. The chamber efficiencies are monitored using cosmic rays triggered by a scintillator hodoscope. Higher statistics measurements are made when the X5 muon beam is available. We report here the measurements of the efficiency versus operating voltage at different source intensities, up to a maximum counting rate of about 700Hz/cm^2. We describe the performance of the chambers during the test up to an overall ageing of 4 ATLAS equivalent years corresponding to an integrated charge of 0.12C/cm^2, including a safety factor of 5.
△ Less
Submitted 28 October, 2004; v1 submitted 27 October, 2004;
originally announced October 2004.