Diagnostic Accuracy of Computed Tomography for Identifying Hospitalization in Patients with Suspected COVID-19
Authors:
Sergey P. Morozov,
Roman V. Reshetnikov,
Victor A. Gombolevskiy,
Natalia V. Ledikhova,
Ivan A. Blokhin,
Vladislav G. Kljashtorny,
Olesya A. Mokienko,
Anton V. Vladzymyrskyy
Abstract:
The controversy of computed tomography (CT) use in COVID-19 screening is associated with ambiguous characteristics of chest CT as a diagnostic test. The reported values of CT sensitivity and specificity calculated using RT-PCR as a reference standard vary widely. The objective of this study was to reevaluate the diagnostic and prognostic value of CT using an alternative approach. This study includ…
▽ More
The controversy of computed tomography (CT) use in COVID-19 screening is associated with ambiguous characteristics of chest CT as a diagnostic test. The reported values of CT sensitivity and specificity calculated using RT-PCR as a reference standard vary widely. The objective of this study was to reevaluate the diagnostic and prognostic value of CT using an alternative approach. This study included 973 symptomatic COVID-19 patients aged 42 $\pm$ 17 years, 56% females. We reviewed the disease dynamics between the initial and follow-up CT studies using a "CT0-4" grading system. Sensitivity and specificity were calculated as conditional probabilities that a patient's condition would improve or deteriorate relative to the initial CT study results. For the calculation of negative (NPV) and positive (PPV) predictive values, we estimated the COVID-19 prevalence in Moscow. We used several ARIMA and EST models with different parameters to fit the data on total cases of COVID-19 from March 6, 2020, to July 20, 2020, and forecast the incidence. The "CT0-4" grading scale demonstrated low sensitivity (28%) but high specificity (95%). The best statistical model for describing the pandemic in Moscow was ETS with multiplicative trend, error, and season type. According to our calculations, with the predicted prevalence of 2.1%, the values of NPV and PPV would be 98% and 10%, correspondingly. We associate the low sensitivity and PPV values with the small sample size of the patients with severe symptoms and non-optimal methodological setup for measuring these specific characteristics. The "CT0-4" grading scale was highly specific and predictive for identifying admissions to hospitals of COVID-19 patients. Despite the ambiguous accuracy, chest CT proved to be an effective practical tool for patient management during the pandemic, provided that the necessary infrastructure and human resources are available.
△ Less
Submitted 31 July, 2020; v1 submitted 29 July, 2020;
originally announced July 2020.
-
MosMedData: Chest CT Scans With COVID-19 Related Findings Dataset
Authors:
S. P. Morozov,
A. E. Andreychenko,
N. A. Pavlov,
A. V. Vladzymyrskyy,
N. V. Ledikhova,
V. A. Gombolevskiy,
I. A. Blokhin,
P. B. Gelezhe,
A. V. Gonchar,
V. Yu. Chernina
Abstract:
This dataset contains anonymised human lung computed tomography (CT) scans with COVID-19 related findings, as well as without such findings. A small subset of studies has been annotated with binary pixel masks depicting regions of interests (ground-glass opacifications and consolidations). CT scans were obtained between 1st of March, 2020 and 25th of April, 2020, and provided by municipal hospital…
▽ More
This dataset contains anonymised human lung computed tomography (CT) scans with COVID-19 related findings, as well as without such findings. A small subset of studies has been annotated with binary pixel masks depicting regions of interests (ground-glass opacifications and consolidations). CT scans were obtained between 1st of March, 2020 and 25th of April, 2020, and provided by municipal hospitals in Moscow, Russia. Permanent link: https://mosmed.ai/datasets/covid19_1110. This dataset is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported (CC BY-NC-ND 3.0) License. Key words: artificial intelligence, COVID-19, machine learning, dataset, CT, chest, imaging
△ Less
Submitted 13 May, 2020;
originally announced May 2020.
-
Discovery of Two Types of Twinkling Can Explain Contradictory Observations among Twinkling Artifact Investigators in Ultrasound Imaging
Authors:
Denis Leonov,
Nicholas Kulberg,
Alexandr Gromov,
Anton Vladzymyrskyy,
Sergey Morozov
Abstract:
Twinkling Artifact is a valuable tool in detecting dense objects such as kidney stones, calculi etc., especially when there is no acoustic shadowing and presence of hyperechogenic tissues obstructs visualization. This phenomenon is not completely understood. Different scientific groups have contradictory findings concerning its properties: some of them observed a decrease in Twinkling intensity at…
▽ More
Twinkling Artifact is a valuable tool in detecting dense objects such as kidney stones, calculi etc., especially when there is no acoustic shadowing and presence of hyperechogenic tissues obstructs visualization. This phenomenon is not completely understood. Different scientific groups have contradictory findings concerning its properties: some of them observed a decrease in Twinkling intensity at elevated pulse repetition frequencies (PRF), while others found Twinkling to be independent from PRF, etc. In this paper we hypothesize that this kind of contradictions can be partially resolved on an assumption that there are two types of Twinkling. The 1st type presumably is produced by random-phased reflections from microcavitation and can be registered even at PRF high enough to suppress blood flow. The 2nd is originated from elastic vibrations as the object under investigation swings like a pendulum in the field of ultrasound. These vibrations can be associated with an external source such as a muscles contraction, etc. or the acoustic radiation force from signals emitted by the transducer. The 2nd type of Twinkling disappears at high PRF and can be regularly observed in silicone and polyurethane phantoms where the occurrence of cavitation microbubbles is highly unlikely. Key Words: Ultrasound Imaging, Twinkling Artifact, Stone Detection, Doppler Effect, Color Frame Map**, Acoustic Radiation Force, Elastic Vibration, Ultrasound Phantom, Cavitation, Microbubbles.
△ Less
Submitted 5 December, 2019;
originally announced December 2019.
-
Incorporating Task-Specific Structural Knowledge into CNNs for Brain Midline Shift Detection
Authors:
Maxim Pisov,
Mikhail Goncharov,
Nadezhda Kurochkina,
Sergey Morozov,
Victor Gombolevskiy,
Valeria Chernina,
Anton Vladzymyrskyy,
Ksenia Zamyatina,
Anna Chesnokova,
Igor Pronin,
Michael Shifrin,
Mikhail Belyaev
Abstract:
Midline shift (MLS) is a well-established factor used for outcome prediction in traumatic brain injury, stroke and brain tumors. The importance of automatic estimation of MLS was recently highlighted by ACR Data Science Institute. In this paper we introduce a novel deep learning based approach for the problem of MLS detection, which exploits task-specific structural knowledge. We evaluate our meth…
▽ More
Midline shift (MLS) is a well-established factor used for outcome prediction in traumatic brain injury, stroke and brain tumors. The importance of automatic estimation of MLS was recently highlighted by ACR Data Science Institute. In this paper we introduce a novel deep learning based approach for the problem of MLS detection, which exploits task-specific structural knowledge. We evaluate our method on a large dataset containing heterogeneous images with significant MLS and show that its mean error approaches the inter-expert variability. Finally, we show the robustness of our approach by validating it on an external dataset, acquired during routine clinical practice.
△ Less
Submitted 14 December, 2019; v1 submitted 13 August, 2019;
originally announced August 2019.
-
Clinical acceptance of software based on artificial intelligence technologies (radiology)
Authors:
S. P. Morozov,
A. V. Vladzymyrskyy,
V. G. Klyashtornyy,
A. E. Andreychenko,
N. S. Kulberg,
V. A. Gombolevsky,
K. A. Sergunova
Abstract:
Aim: provide a methodological framework for the process of clinical tests, clinical acceptance, and scientific assessment of algorithms and software based on the artificial intelligence (AI) technologies. Clinical tests are considered as a preparation stage for the software registration as a medical product. The authors propose approaches to evaluate accuracy and efficiency of the AI algorithms fo…
▽ More
Aim: provide a methodological framework for the process of clinical tests, clinical acceptance, and scientific assessment of algorithms and software based on the artificial intelligence (AI) technologies. Clinical tests are considered as a preparation stage for the software registration as a medical product. The authors propose approaches to evaluate accuracy and efficiency of the AI algorithms for radiology.
△ Less
Submitted 27 February, 2020; v1 submitted 1 August, 2019;
originally announced August 2019.