-
Ultrasensitive Inverse Weak-Value Tilt Meter
Authors:
Julián Martínez-Rincón,
Christopher A. Mullarkey,
Gerardo I. Viza,
Wei-Tao Liu,
John C. Howell
Abstract:
We present an interferometric technique for measuring ultra-small tilts. The information of a tilt in one of the mirrors of a modified Sagnac interferometer is carried by the phase difference between the counter propagating laser beams. Using a small misalignment of the interferometer, orthogonal to the plane of the tilt, a bimodal (or two-fringe) pattern is induced in the beam's transverse power…
▽ More
We present an interferometric technique for measuring ultra-small tilts. The information of a tilt in one of the mirrors of a modified Sagnac interferometer is carried by the phase difference between the counter propagating laser beams. Using a small misalignment of the interferometer, orthogonal to the plane of the tilt, a bimodal (or two-fringe) pattern is induced in the beam's transverse power distribution. By tracking the mean of such a distribution, using a split detector, a sensitive measurement of the phase is performed. With 1.2 mW of continuous-wave laser power, the technique has a shot noise limited sensitivity of 56 frad/$\sqrt{\mbox{Hz}}$, and a measured noise floor of 200 frad/$\sqrt{\mbox{Hz}}$ for tilt frequencies above 2 Hz. A tilt of 200 frad corresponds to a differential displacement of 4.0 fm in our setup. The novelty of the protocol relies on signal amplification due to the misalignment, and on good performance at low frequencies. A noise floor of about 70 prad/$\sqrt{\mbox{Hz}}$ is observed between 2 and 100 mHz.
△ Less
Submitted 21 June, 2017; v1 submitted 18 January, 2017;
originally announced January 2017.
-
Anomalous Amplification of a Homodyne signal via Almost-Balanced Weak Values
Authors:
Wei-Tao Liu,
Julián Martínez-Rincón,
Gerardo I. Viza,
John C. Howell
Abstract:
The technique of almost-balanced weak values amplification (ABWV) was recently proposed [Phys. Rev. Lett. 116: 100803 (2016)]. We demonstrate this technique using a modified Sagnac interferometer, where the counter-propagating beams are spatially separated. The separation between the two beams provides additional amplification, with respect to using colinear beams in a Sagnac interferometer. As a…
▽ More
The technique of almost-balanced weak values amplification (ABWV) was recently proposed [Phys. Rev. Lett. 116: 100803 (2016)]. We demonstrate this technique using a modified Sagnac interferometer, where the counter-propagating beams are spatially separated. The separation between the two beams provides additional amplification, with respect to using colinear beams in a Sagnac interferometer. As a demonstration of the technique, we perform measurements of the angular velocity in one of the mirrors of the interferometer. Within the same setup, the weak-value amplification technique is also performed for comparison. Much higher amplification factors can be obtained using the almost-balanced weak values technique, with the best one achieved in our experiments being as high as $1.2\times10^7$. In addition, the amplification factor monotonically increases with decreasing post-selection phase for the ABWV case in our experiments, which is not the case for weak-value amplification at small post-selection phases.
△ Less
Submitted 25 December, 2016;
originally announced December 2016.
-
Complementary weak-value amplification with concatenated postselections
Authors:
Gerardo I. Viza,
Julián Martínez-Rincón,
Wei-Tao Liu,
John C. Howell
Abstract:
We measure a transverse momentum kick in a Sagnac interferometer using weak-value amplification with two postselections. The first postselection is controlled by a polarization dependent phase mismatch between both paths of a Sagnac interferometer and the second postselection is controlled by a polarizer at the exit port. By monitoring the darkport of the interferometer, we study the complementary…
▽ More
We measure a transverse momentum kick in a Sagnac interferometer using weak-value amplification with two postselections. The first postselection is controlled by a polarization dependent phase mismatch between both paths of a Sagnac interferometer and the second postselection is controlled by a polarizer at the exit port. By monitoring the darkport of the interferometer, we study the complementary amplification of the concatenated postselections, where the polarization extinction ratio is greater than the contrast of the spatial interference. In this case, we find an improvement in the amplification of the signal of interest by introducing a second postselection to the system.
△ Less
Submitted 17 October, 2016; v1 submitted 7 June, 2016;
originally announced June 2016.
-
Can Anomalous Amplification be Attained Without Postselection?
Authors:
Julián Martínez-Rincón,
Wei-Tao Liu,
Gerardo I. Viza,
John C. Howell
Abstract:
We present a parameter estimation technique based on performing joint measurements of a weak interaction away from the weak-value-amplification approximation. Two detectors are used to collect full statistics of the correlations between two weakly entangled degrees of freedom. Without the need of postselection, the protocol resembles the anomalous amplification of an imaginary-weak-value-like resp…
▽ More
We present a parameter estimation technique based on performing joint measurements of a weak interaction away from the weak-value-amplification approximation. Two detectors are used to collect full statistics of the correlations between two weakly entangled degrees of freedom. Without the need of postselection, the protocol resembles the anomalous amplification of an imaginary-weak-value-like response. The amplification is induced in the difference signal of both detectors allowing robustness to different sources of technical noise, and offering in addition the advantages of balanced signals for precision metrology. All of the Fisher information about the parameter of interest is collected, and a phase controls the amplification response. We experimentally demonstrate the proposed technique by measuring polarization rotations in a linearly polarized laser pulse. The effective sensitivity and precision of a split detector is increased when compared to a conventional continuous-wave balanced detection technique.
△ Less
Submitted 27 February, 2016; v1 submitted 16 September, 2015;
originally announced September 2015.
-
Weak-value amplification of the fast-light effect in rubidium vapor
Authors:
Mohammad Mirhosseini,
Gerardo Viza,
Omar S. Magaña-Loaiza,
Mehul Malik,
John C. Howell,
Robert W. Boyd
Abstract:
We use weak-value amplification to enhance the polarization-sensitive fast-light effect from induced Raman absorption in hot rubidium vapor. We experimentally demonstrate that projecting the output signal into an appropriate polarization state enables a pulse advancement of 4.2 μs, which is 15 times larger than that naturally caused by dispersion. More significantly, we show that combining weak-va…
▽ More
We use weak-value amplification to enhance the polarization-sensitive fast-light effect from induced Raman absorption in hot rubidium vapor. We experimentally demonstrate that projecting the output signal into an appropriate polarization state enables a pulse advancement of 4.2 μs, which is 15 times larger than that naturally caused by dispersion. More significantly, we show that combining weak-value amplification with the dispersive response of an atomic system provides a clear advantage in terms of the maximum pulse advancement achievable for a given value of loss. This technique has potential applications for designing novel quantum-information-processing gates and optical buffers for telecommunication systems.
△ Less
Submitted 9 December, 2014;
originally announced December 2014.
-
Experimentally quantifying the advantages of weak-value-based metrology
Authors:
Gerardo I. Viza,
Julián Martínez-Rincón,
Gabriel B. Alves,
Andrew N. Jordan,
John C. Howell
Abstract:
We experimentally investigate the relative advantages of implementing weak-value-based metrology versus standard methods. While the techniques outlined herein apply more generally, we measure small optical beam deflections both using a Sagnac interferometer with a monitored dark port (the weak-value-based technique), and by focusing the entire beam to a split detector (the standard technique). By…
▽ More
We experimentally investigate the relative advantages of implementing weak-value-based metrology versus standard methods. While the techniques outlined herein apply more generally, we measure small optical beam deflections both using a Sagnac interferometer with a monitored dark port (the weak-value-based technique), and by focusing the entire beam to a split detector (the standard technique). By introducing controlled external transverse detector modulations and transverse beam deflection momentum modulations, we quantify the mitigation of these sources in the weak-value-based experiment versus the standard focusing experiment. The experiments are compared using a combination of deterministic and stochastic methods. In all cases, the weak-values technique performs the same or better than the standard technique by up to two orders of magnitude in precision for our parameters. We further measure the statistical efficiency of the weak-values-based technique. By postselecting on $1\%$ of the photons, we obtain $99\%$ of the available Fisher information of the beam deflection parameter.
△ Less
Submitted 23 September, 2015; v1 submitted 30 October, 2014;
originally announced October 2014.
-
Weak Values Technique for Velocity Measurements
Authors:
Gerardo I. Viza,
Julián Martínez-Rincón,
Gregory A. Howland,
Hadas Frostig,
Itay Shomroni,
Barak Dayan,
John C. Howell
Abstract:
In a recent letter, Brunner and Simon propose an interferometric scheme using imaginary weak values with a frequency-domain analysis to outperform standard interferometry in longitudinal phase shifts [N. Brunner and C. Simon, Phys. Rev. Lett {\bf105} (2010)]. Here we demonstrate an interferometric scheme combined with a time-domain analysis to measure longitudinal velocities. The technique employs…
▽ More
In a recent letter, Brunner and Simon propose an interferometric scheme using imaginary weak values with a frequency-domain analysis to outperform standard interferometry in longitudinal phase shifts [N. Brunner and C. Simon, Phys. Rev. Lett {\bf105} (2010)]. Here we demonstrate an interferometric scheme combined with a time-domain analysis to measure longitudinal velocities. The technique employs the near-destructive interference of non-Fourier limited pulses, one Doppler shifted due to a moving mirror, in a Michelson interferometer. We achieve a velocity measurement of 400 fm/s and show our estimator to be efficient by reaching its Cramér-Rao bound.
△ Less
Submitted 14 May, 2013; v1 submitted 29 March, 2013;
originally announced April 2013.