-
Metis: the Solar Orbiter visible light and ultraviolet coronal imager
Authors:
Ester Antonucci,
Marco Romoli,
Vincenzo Andretta,
Silvano Fineschi,
Petr Heinzel,
J. Daniel Moses,
Giampiero Naletto,
Gianalfredo Nicolini,
Daniele Spadaro,
Luca Teriaca,
Arkadiusz Berlicki,
Gerardo Capobianco,
Giuseppe Crescenzio,
Vania Da Deppo,
Mauro Focardi,
Fabio Frassetto,
Klaus Heerlein,
Federico Landini,
Enrico Magli,
Andrea Marco Malvezzi,
Giuseppe Massone,
Radek Melich,
Piergiorgio Nicolosi,
Giancarlo Noci,
Maurizio Pancrazzi
, et al. (78 additional authors not shown)
Abstract:
Metis is the first solar coronagraph designed for a space mission capable of performing simultaneous imaging of the off-limb solar corona in both visible and UV light. The observations obtained with Metis aboard the Solar Orbiter ESA-NASA observatory will enable us to diagnose, with unprecedented temporal coverage and spatial resolution, the structures and dynamics of the full corona from 1.7…
▽ More
Metis is the first solar coronagraph designed for a space mission capable of performing simultaneous imaging of the off-limb solar corona in both visible and UV light. The observations obtained with Metis aboard the Solar Orbiter ESA-NASA observatory will enable us to diagnose, with unprecedented temporal coverage and spatial resolution, the structures and dynamics of the full corona from 1.7 $R_\odot$ to about 9 $R_\odot$. Due to the uniqueness of the Solar Orbiter mission profile, Metis will be able to observe the solar corona from a close vantage point (down to 0.28 AU), achieving out-of-ecliptic views with the increase of the orbit inclination over time. Moreover, observations near perihelion, during the phase of lower rotational velocity of the solar surface relative to the spacecraft, will allow longer-term studies of the coronal features. Thanks to a novel occultation design and a combination of a UV interference coating of the mirrors and a spectral bandpass filter, Metis images the solar corona simultaneously in the visible light band, between 580 and 640 nm, and in the UV H I Lyman-α line at 121.6 nm. The coronal images in both the UV Lyman-α and polarised visible light are obtained at high spatial resolution with a spatial scale down to about 2000 km and 15000 km at perihelion, in the cases of the visible and UV light, respectively. A temporal resolution down to 1 second can be achieved when observing coronal fluctuations in visible light. The Metis measurements will allow for complete characterisation of the main physical parameters and dynamics of the electron and neutral hydrogen/proton plasma components of the corona in the region where the solar wind undergoes acceleration and where the onset and initial propagation of coronal mass ejections take place, thus significantly improving our understanding of the region connecting the Sun to the heliosphere.
△ Less
Submitted 14 November, 2019;
originally announced November 2019.
-
POLLUX: a UV spectropolarimeter for the LUVOIR space telescope project
Authors:
Eduard Muslimov,
Jean-Claude Bouret,
Coralie Neiner,
Arturo López Ariste,
Marc Ferrari,
Sébastien Vivès,
Emmanuel Hugot,
Robert Grange,
Simona Lombardo,
Louise Lopes,
Josiane Costerate,
Frank Brachet
Abstract:
The present paper describes the current baseline optical design of POLLUX, a high-resolution spectropolarimeter for the future LUVOIR mission. The instrument will operate in the ultraviolet (UV) domain from 90 to 390 nm in both spectropolarimetric and pure spectroscopic modes. The working range is split between 3 channels -- far (90-124.5 nm), medium (118.5-195 nm) and near (195-390 nm) UV. Each o…
▽ More
The present paper describes the current baseline optical design of POLLUX, a high-resolution spectropolarimeter for the future LUVOIR mission. The instrument will operate in the ultraviolet (UV) domain from 90 to 390 nm in both spectropolarimetric and pure spectroscopic modes. The working range is split between 3 channels -- far (90-124.5 nm), medium (118.5-195 nm) and near (195-390 nm) UV. Each of the channels is composed of a polarimeter followed by an echelle spectrograph consisting of a classical off-axis paraboloid collimator, echelle grating with a high grooves frequency and a cross-disperser grating operating also as a camera. The latter component integrates some advanced technologies: it is a blazed grating with a complex grooves pattern formed by holographic recording, which is manufactured on a freeform surface. One of the key features underlying the current design is the large spectral length of each order ~6 nm, which allows to record wide spectral lines without any discontinuities. The modelling results show that the optical design will provide the required spectral resolving power higher than R ~ 120,000 over the entire working range for a point source object with angular size of 30 mas. It is also shown that with the 15-m primary mirror of the LUVOIR telescope the instrument will provide an effective collecting area up to 38 569 cm 2. Such a performance will allow to perform a number of groundbreaking scientific observations. Finally, the future work and the technological risks of the design are discussed in details.
△ Less
Submitted 23 May, 2018;
originally announced May 2018.
-
Bitcoin With Heterogeneous Block Sizes: A Scaling Proposal
Authors:
Santi J. Vives
Abstract:
We propose a bitcoin generalization as a solution to the problem of scalability. The block is redefined as a sequence of sub-blocks of increasing sizes that coexist as different levels of compromise between decentralization and transactions throughput. Miners and users can decide individually the sizes they use without affecting others in the network.
We propose a bitcoin generalization as a solution to the problem of scalability. The block is redefined as a sequence of sub-blocks of increasing sizes that coexist as different levels of compromise between decentralization and transactions throughput. Miners and users can decide individually the sizes they use without affecting others in the network.
△ Less
Submitted 12 May, 2018;
originally announced May 2018.
-
Combining freeform optics and curved detectors for wide field imaging: a polynomial approach over squared aperture
Authors:
Eduard Muslimov,
Emmanuel Hugot,
Wilfried Jahn,
Sebastien Vives,
Marc Ferrari,
Bertrand Chambion,
David Henry,
Cristophe Gaschet
Abstract:
In the recent years a significant progress was achieved in the field of design and fabrication of optical systems based on freeform optical surfaces. They provide a possibility to build fast, wide-angle and high-resolution systems, which are very compact and free of obscuration. However, the field of freeform surfaces design techniques still remains underexplored. In the present paper we use the m…
▽ More
In the recent years a significant progress was achieved in the field of design and fabrication of optical systems based on freeform optical surfaces. They provide a possibility to build fast, wide-angle and high-resolution systems, which are very compact and free of obscuration. However, the field of freeform surfaces design techniques still remains underexplored. In the present paper we use the mathematical apparatus of orthogonal polynomials defined over a square aperture, which was developed before for the tasks of wavefront reconstruction, to describe shape of a mirror surface. Two cases, namely Legendre polynomials and generalization of the Zernike polynomials on a square, are considered. The potential advantages of these polynomials sets are demonstrated on example of a three-mirror unobscured telescope with F/#=2.5 and FoV=7.2x7.2°. In addition, we discuss possibility of use of curved detectors in such a design.
△ Less
Submitted 17 June, 2017;
originally announced June 2017.
-
The FLARE mission: Deep and Wide-field 1-5$μ$m Imaging and Spectroscopy for the Early Universe: a proposal for M5 Cosmic Vision call
Authors:
D. Burgarella,
P. Levacher,
S. Vives,
K. Dohlen,
S. Pascal
Abstract:
FLARE (First Light And Reionization Explorer) is a space mission that will be submitted to ESA (M5 call). Its primary goal (about 80% of lifetime) is to identify and study galaxies that dwell in the universe before the end of the reionization up to about z = 15, a redshift that might not be statistically reachable for JWST, Euclid and WFIRST. A secondary objective (about 20% of lifetime) is to sur…
▽ More
FLARE (First Light And Reionization Explorer) is a space mission that will be submitted to ESA (M5 call). Its primary goal (about 80% of lifetime) is to identify and study galaxies that dwell in the universe before the end of the reionization up to about z = 15, a redshift that might not be statistically reachable for JWST, Euclid and WFIRST. A secondary objective (about 20% of lifetime) is to survey star formation in the Milky Way.
The strategy selected for FLARE optimizes the science return: imaging and spectroscopic integral-field observations will be carried out simultaneously on two parallel focal planes and over very wide instantaneous fields of view. FLARE will feature an instantaneous field of view of about 0.2 deg$^2$ with 0.2-arcsec pixels and an instantaneous integral-field spectroscopic field of view of about 1 arcmin$^2$ with R = 500 - 1000 and an angular resolution of about 0.4 arcsec. To detect first-light galaxies, the imaging and spectroscopic survey (parallel observations over about 6 years) will reach m$_{AB}$ = 28 and f$_λ$ = 10$^{-18}$ erg/cm$^2$/S.
FLARE will help addressing two of ESA's Cosmic Vision themes: a) "How did the universe originate and what is it made of?" and b) "What are the conditions for planet formation and the emergence of life?" and more specifically, "From gas and dust to stars and planets".
FLARE will provide to the ESA community a leading position to statistically study the early universe after JWST's deep but pin-hole surveys. Moreover, the instrumental development of wide-field imaging and wide-field integral-field spectroscopy in space will be a major breakthrough after making them available on ground-based telescopes.
△ Less
Submitted 22 July, 2016;
originally announced July 2016.
-
THERMAP: a mid-infrared spectro-imager for space missions to small bodies in the inner solar system
Authors:
O. Groussin,
J. Licandro,
J. Helbert,
J. -L. Reynaud,
P. Levacher,
M. Reyes García-Talavera,
V. Alí-Lagoa,
P. -E. Blanc,
E. Brageot,
B. Davidsson,
M. Delbó,
M. Deleuze,
A. Delsanti,
J. J. Diaz Garcia,
K. Dohlen,
D. Ferrand,
S. Green,
L. Jorda,
E. Joven Álvarez,
J. Knollenberg,
E. Kührt,
P. Lamy,
E. Lellouch,
J. Le Merrer,
B. Marty
, et al. (6 additional authors not shown)
Abstract:
We present THERMAP, a mid-infrared (8-16 μm) spectro-imager for space missions to small bodies in the inner solar system, developed in the framework of the MarcoPolo-R asteroid sample return mission. THERMAP is very well suited to characterize the surface thermal environment of a NEO and to map its surface composition. The instrument has two channels, one for imaging and one for spectroscopy: it i…
▽ More
We present THERMAP, a mid-infrared (8-16 μm) spectro-imager for space missions to small bodies in the inner solar system, developed in the framework of the MarcoPolo-R asteroid sample return mission. THERMAP is very well suited to characterize the surface thermal environment of a NEO and to map its surface composition. The instrument has two channels, one for imaging and one for spectroscopy: it is both a thermal camera with full 2D imaging capabilities and a slit spectrometer. THERMAP takes advantage of the recent technological developments of uncooled microbolometers detectors, sensitive in the mid-infrared spectral range. THERMAP can acquire thermal images (8-18 μm) of the surface and perform absolute temperature measurements with a precision better than 3.5 K above 200 K. THERMAP can acquire mid-infrared spectra (8-16 μm) of the surface with a spectral resolution Δλ of 0.3 μm. For surface temperatures above 350 K, spectra have a signal-to-noise ratio >60 in the spectral range 9-13 μm where most emission features occur.
△ Less
Submitted 9 September, 2015;
originally announced September 2015.
-
Prime Focus Spectrograph for the Subaru telescope: massively multiplexed optical and near-infrared fiber spectrograph
Authors:
Hajime Sugai,
Naoyuki Tamura,
Hiroshi Karoji,
Atsushi Shimono,
Naruhisa Takato,
Masahiko Kimura,
Youichi Ohyama,
Akitoshi Ueda,
Hrand Aghazarian,
Marcio Vital de Arruda,
Robert H. Barkhouser,
Charles L. Bennett,
Steve Bickerton,
Alexandre Bozier,
David F. Braun,
Khanh Bui,
Christopher M. Capocasale,
Michael A. Carr,
Bruno Castilho,
Yin-Chang Chang,
Hsin-Yo Chen,
Richard C. Y. Chou,
Olivia R. Dawson,
Richard G. Dekany,
Eric M. Ek
, et al. (59 additional authors not shown)
Abstract:
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multifiber spectrograph with 2394 science fibers distributed across a 1.3-deg diameter field of view at the Subaru 8.2-m telescope. The wide wavelength coverage from 0.38 μm to 1.26 μm, with a resolving power of 3000, simultaneously strengthens its ability to target three main survey programs: cosmology, galactic archaeology and galaxy…
▽ More
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multifiber spectrograph with 2394 science fibers distributed across a 1.3-deg diameter field of view at the Subaru 8.2-m telescope. The wide wavelength coverage from 0.38 μm to 1.26 μm, with a resolving power of 3000, simultaneously strengthens its ability to target three main survey programs: cosmology, galactic archaeology and galaxy/AGN evolution. A medium resolution mode with a resolving power of 5000 for 0.71 μm to 0.89 μm will also be available by simply exchanging dispersers. We highlight some of the technological aspects of the design. To transform the telescope focal ratio, a broad-band coated microlens is glued to each fiber tip. A higher transmission fiber is selected for the longest part of the cable system, optimizing overall throughput; a fiber with low focal ratio degradation is selected for the fiber-positioner and fiber-slit components, minimizing the effects of fiber movements and fiber bending. Fiber positioning will be performed by a positioner consisting of two stages of piezo-electric rotary motors. The positions of these motors are measured by taking an image of artificially back-illuminated fibers with the metrology camera located in the Cassegrain container; the fibers are placed in the proper location by iteratively measuring and then adjusting the positions of the motors. Target light reaches one of the four identical fast-Schmidt spectrograph modules, each with three arms. The PFS project has passed several project-wide design reviews and is now in the construction phase.
△ Less
Submitted 2 July, 2015;
originally announced July 2015.
-
Active optics for high-dynamic variable curvature mirrors
Authors:
Emmanuel Hugot,
Marc Ferrari,
Gerard R. Lemaitre,
Fabrice Madec,
Sebastien Vives,
Elodie Chardin,
David Le Mignant,
Jean Gabriel Cuby
Abstract:
Variable curvature mirrors of large amplitude are designed by using finite element analysis. The specific case studied reaches at least a 800 μm sag with an optical quality better than λ/5 over a 120 mm clear aperture. We highlight the geometrical nonlinearity and the plasticity effect.
Variable curvature mirrors of large amplitude are designed by using finite element analysis. The specific case studied reaches at least a 800 μm sag with an optical quality better than λ/5 over a 120 mm clear aperture. We highlight the geometrical nonlinearity and the plasticity effect.
△ Less
Submitted 18 November, 2014;
originally announced November 2014.
-
Optical Design of the SuMIRe PFS Spectrograph
Authors:
Sandrine Pascal,
Sebastien Vives,
Robert Barkhouser,
James Gunn
Abstract:
The SuMIRe Prime Focus Spectrograph (PFS), developed for the 8-m class SUBARU telescope, will consist of four identical spectrographs, each receiving 600 fibers from a 2394 fiber robotic positioner at the telescope prime focus. Each spectrograph includes three spectral channels to cover the wavelength range 0.38-1.26 um with a resolving power ranging between 2000 and 4000. A medium resolution mode…
▽ More
The SuMIRe Prime Focus Spectrograph (PFS), developed for the 8-m class SUBARU telescope, will consist of four identical spectrographs, each receiving 600 fibers from a 2394 fiber robotic positioner at the telescope prime focus. Each spectrograph includes three spectral channels to cover the wavelength range 0.38-1.26 um with a resolving power ranging between 2000 and 4000. A medium resolution mode is also implemented to reach a resolving power of 5000 at 0.8 um. Each spectrograph is made of 4 optical units: the entrance unit which produces three corrected collimated beams and three camera units (one per spectral channel). The beam is split by using two large dichroics; and in each arm, the light is dispersed by large VPH gratings. The proposed optical design was optimized to achieve the requested image quality while simplifying the manufacturing of the whole optical system. The camera design consists in an innovative Schmidt camera observing a large field-of-view (10 degrees) with a very fast beam. To achieve such a performance, the classical spherical mirror is replaced by a catadioptric mirror (i.e meniscus lens with a reflective surface on the rear side of the glass, like a Mangin mirror). This article focuses on the optical architecture of the PFS spectrograph and the perfornance achieved. We will first described the global optical design of the spectrograph. Then, we will focus on the Mangin-Schmidt camera design. The analysis of the optical performance and the results obtained are presented in the last section.
△ Less
Submitted 18 August, 2014;
originally announced August 2014.
-
The near infrared camera for the Subaru Prime Focus Spectrograph
Authors:
Stephen A. Smee,
James E. Gunn,
Mirek Golebiowski,
Robert Barkhouser,
Sebastien Vives,
Sandrine Pascal,
Michael Carr,
Stephen C. Hope,
Craig Loomis,
Murdock Hart,
Hajime Sugai,
Naoyuki Tamura,
Atsushi Shimono
Abstract:
We present the detailed design of the near infrared camera for the SuMIRe (Subaru Measurement of Images and Redshifts) Prime Focus Spectrograph (PFS) being developed for the Subaru Telescope. The PFS spectrograph is designed to collect spectra from 2394 objects simultaneously, covering wavelengths that extend from 380 nm - 1.26 um. The spectrograph is comprised of four identical spectrograph modul…
▽ More
We present the detailed design of the near infrared camera for the SuMIRe (Subaru Measurement of Images and Redshifts) Prime Focus Spectrograph (PFS) being developed for the Subaru Telescope. The PFS spectrograph is designed to collect spectra from 2394 objects simultaneously, covering wavelengths that extend from 380 nm - 1.26 um. The spectrograph is comprised of four identical spectrograph modules, with each module collecting roughly 600 spectra from a robotic fiber positioner at the telescope prime focus. Each spectrograph module will have two visible channels covering wavelength ranges 380 nm - 640 nm and 640 nm - 955 nm, and one near infrared (NIR) channel with a wavelength range 955 nm - 1.26 um. Dispersed light in each channel is imaged by a 300 mm focal length, f/1.07, vacuum Schmidt camera onto a 4k x 4k, 15 um pixel, detector format. For the NIR channel a HgCdTe substrate-removed Teledyne 1.7 um cutoff device is used. In the visible channels, CCDs from Hamamatsu are used. These cameras are large, having a clear aperture of 300 mm at the entrance window, and a mass of ~ 250 kg.
Like the two visible channel cameras, the NIR camera contains just four optical elements: a two-element refractive corrector, a Mangin mirror, and a field flattening lens. This simple design produces very good imaging performance considering the wide field and wavelength range, and it does so in large part due to the use of a Mangin mirror (a lens with a reflecting rear surface) for the Schmidt primary. In the case of the NIR camera, the rear reflecting surface is a dichroic, which reflects in-band wavelengths and transmits wavelengths beyond 1.26 um. This, combined with a thermal rejection filter coating on the rear surface of the second corrector element, greatly reduces the out-of-band thermal radiation that reaches the detector.
△ Less
Submitted 12 August, 2014;
originally announced August 2014.
-
Fiber Optical Cable and Connector System (FOCCoS) for PFS/Subaru
Authors:
Antonio Cesar de Oliveira,
Lígia Souza de Oliveira,
Márcio V. de Arruda,
Lucas Souza Marrara,
Leandro H. dos Santos,
Décio Ferreira,
Jesulino B. dos Santos,
Josimar A. Rosa,
Orlando V. Junior,
Jeferson M. Pereira,
Bruno Castilho,
Clemens Gneiding,
Laerte S. Junior,
Claudia M. de Oliveira,
James E. Gunn,
Akitoshi Ueda,
Naruhisa Takato,
Atsushi Shimono,
Hajime Sugai,
Hiroshi Karoji,
Masahiko Kimura,
Naoyuki Tamura,
Shiang-Yu Wang,
Graham Murray,
David Le Mignant
, et al. (7 additional authors not shown)
Abstract:
FOCCoS, Fiber Optical Cable and Connector System, has the main function of capturing the direct light from the focal plane of Subaru Telescope using optical fibers, each one with a microlens in its tip, and conducting this light through a route containing connectors to a set of four spectrographs. The optical fiber cable is divided in 3 different segments called Cable A, Cable B and Cable C. Multi…
▽ More
FOCCoS, Fiber Optical Cable and Connector System, has the main function of capturing the direct light from the focal plane of Subaru Telescope using optical fibers, each one with a microlens in its tip, and conducting this light through a route containing connectors to a set of four spectrographs. The optical fiber cable is divided in 3 different segments called Cable A, Cable B and Cable C. Multi-fibers connectors assure precise connection among all optical fibers of the segments, providing flexibility for instrument changes. To assure strong and accurate connection, these sets are arranged inside two types of assemblies: the Tower Connector, for connection between Cable C and Cable B; and the Gang Connector, for connection between Cable B and Cable A. Throughput tests were made to evaluate the efficiency of the connections. A lifetime test connection is in progress. Cable C is installed inside the PFI, Prime Focus Instrument, where each fiber tip with a microlens is bonded to the end of the shaft of a 2-stage piezo-electric rotatory motor positioner; this assembly allows each fiber to be placed anywhere within its patrol region, which is 9.5mm diameter.. Each positioner uses a fiber arm to support the ferrule, the microlens, and the optical fiber. 2400 of these assemblies are arranged on a motor bench plate in a hexagonal-closed-packed disposition.
△ Less
Submitted 12 August, 2014;
originally announced August 2014.
-
Current status of the Spectrograph System for the SuMIRe/PFS
Authors:
S. Vives,
D. Le Mignant,
J. E. Gunn,
S. Smee,
L. Souza de Oliveira,
N. Tamura,
H. Sugai,
R. Barkhouser,
A. Bozier,
M. A. Carr,
A. Cesar de Oliveira,
D. Ferrand,
M. Golebiowski,
M. Hart,
S. Hope,
M. Jaquet,
F. Madec,
S. Pascal,
T. Pegot-Ogier,
M. Vittal de Arruda
Abstract:
The Prime Focus Spectrograph (PFS) is a new facility instrument for Subaru Telescope which will be installed in around 2017. It is a multi-object spectrograph fed by about 2400 fibers placed at the prime focus covering a hexagonal field-of-view with 1.35 deg diagonals and capable of simultaneously obtaining data of spectra with wavelengths ranging from 0.38 um to 1.26 um. The spectrograph system i…
▽ More
The Prime Focus Spectrograph (PFS) is a new facility instrument for Subaru Telescope which will be installed in around 2017. It is a multi-object spectrograph fed by about 2400 fibers placed at the prime focus covering a hexagonal field-of-view with 1.35 deg diagonals and capable of simultaneously obtaining data of spectra with wavelengths ranging from 0.38 um to 1.26 um. The spectrograph system is composed of four identical modules each receiving the light from 600 fibers. Each module incorporates three channels covering the wavelength ranges 0.38-0.65 mu ("Blue"), 0.63-0.97 mu ("Red"), and 0.94-1.26 mu ("NIR") respectively; with resolving power which progresses fairly smoothly from about 2000 in the blue to about 4000 in the infrared. An additional spectral mode allows reaching a spectral resolution of 5000 at 0.8mu (red). The proposed optical design is based on a Schmidt collimator facing three Schmidt cameras (one per spectral channel). This architecture is very robust, well known and documented. It allows for high image quality with only few simple elements (high throughput) at the expense of the central obscuration, which leads to larger optics. Each module has to be modular in its design to allow for integration and tests and for its safe transport up to the telescope: this is the main driver for the mechanical design. In particular, each module will be firstly fully integrated and validated at LAM (France) before it is shipped to Hawaii. All sub-assemblies will be indexed on the bench to allow for their accurate repositioning. This paper will give an overview of the spectrograph system which has successfully passed the Critical Design Review (CDR) in 2014 March and which is now in the construction phase.
△ Less
Submitted 12 August, 2014;
originally announced August 2014.
-
Progress with the Prime Focus Spectrograph for the Subaru Telescope: a massively multiplexed optical and near-infrared fiber spectrograph
Authors:
Hajime Sugai,
Naoyuki Tamura,
Hiroshi Karoji,
Atsushi Shimono,
Naruhisa Takato,
Masahiko Kimura,
Youichi Ohyama,
Akitoshi Ueda,
Hrand Aghazarian,
Marcio Vital de Arruda,
Robert H. Barkhouser,
Charles L. Bennett,
Steve Bickerton,
Alexandre Bozier,
David F. Braun,
Khanh Bui,
Christopher M. Capocasale,
Michael A. Carr,
Bruno Castilho,
Yin-Chang Chang,
Hsin-Yo Chen,
Richard C. Y. Chou,
Olivia R. Dawson,
Richard G. Dekany,
Eric M. Ek
, et al. (59 additional authors not shown)
Abstract:
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber spectrograph with 2394 science fibers, which are distributed in 1.3 degree diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide wavelength coverage from 0.38 um to 1.26 um, with the resolving power of 3000, strengthens its ability to target three main survey programs: cosmology, Galactic archaeology,…
▽ More
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber spectrograph with 2394 science fibers, which are distributed in 1.3 degree diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide wavelength coverage from 0.38 um to 1.26 um, with the resolving power of 3000, strengthens its ability to target three main survey programs: cosmology, Galactic archaeology, and galaxy/AGN evolution. A medium resolution mode with resolving power of 5000 for 0.71 um to 0.89 um also will be available by simply exchanging dispersers. PFS takes the role for the spectroscopic part of the Subaru Measurement of Images and Redshifts project, while Hyper Suprime-Cam works on the imaging part. To transform the telescope plus WFC focal ratio, a 3-mm thick broad-band coated glass-molded microlens is glued to each fiber tip. A higher transmission fiber is selected for the longest part of cable system, while one with a better FRD performance is selected for the fiber-positioner and fiber-slit components, given the more frequent fiber movements and tightly curved structure. Each Fiber positioner consists of two stages of piezo-electric rotary motors. Its engineering model has been produced and tested. Fiber positioning will be performed iteratively by taking an image of artificially back-illuminated fibers with the Metrology camera located in the Cassegrain container. The camera is carefully designed so that fiber position measurements are unaffected by small amounts of high special-frequency inaccuracies in WFC lens surface shapes. Target light carried through the fiber system reaches one of four identical fast-Schmidt spectrograph modules, each with three arms. Prototype VPH gratings have been optically tested. CCD production is complete, with standard fully-depleted CCDs for red arms and more-challenging thinner fully-depleted CCDs with blue-optimized coating for blue arms.
△ Less
Submitted 12 August, 2014;
originally announced August 2014.
-
A spectrograph instrument concept for the Prime Focus Spectrograph (PFS) on Subaru Telescope
Authors:
Sébastien Vives,
David Le Mignant,
Fabrice Madec,
Marc Jaquet,
Eric Prieto,
Laurent Martin,
Olivier Le Fèvre,
James Gunn,
Michael Carr,
Stephen Smee,
Robert Barkhouser,
Hajime Sugai,
Naoyuki Tamura
Abstract:
We describe the conceptual design of the spectrograph opto-mechanical concept for the SuMIRe Prime Focus Spectrograph (PFS) being developed for the SUBARU telescope. The SuMIRe PFS will consist of four identical spectrographs, each receiving 600 fibers from a 2400 fiber robotic positioner at the prime focus. Each spectrograph will have three channels covering in total, a wavelength range from 380…
▽ More
We describe the conceptual design of the spectrograph opto-mechanical concept for the SuMIRe Prime Focus Spectrograph (PFS) being developed for the SUBARU telescope. The SuMIRe PFS will consist of four identical spectrographs, each receiving 600 fibers from a 2400 fiber robotic positioner at the prime focus. Each spectrograph will have three channels covering in total, a wavelength range from 380 nm to 1300 nm. The requirements for the instrument are summarized in Section 1. We present the optical design and the optical performance and analysis in Section 2. Section 3 introduces the mechanical design, its requirements and the proposed concepts. Finally, the AIT phases for the Spectrograph System are described in Section 5.
△ Less
Submitted 9 October, 2012;
originally announced October 2012.
-
Prime Focus Spectrograph - Subaru's future -
Authors:
Hajime Sugai,
Hiroshi Karoji,
Naruhisa Takato,
Naoyuki Tamura,
Atsushi Shimono,
Youichi Ohyama,
Akitoshi Ueda,
Hung-Hsu Ling,
Marcio Vital de Arruda,
Robert H. Barkhouser,
Charles L. Bennett,
Steve Bickerton,
David F. Braun,
Robin J. Bruno,
Michael A. Carr,
João Batista de Carvalho Oliveira,
Yin-Chang Chang,
Hsin-Yo Chen,
Richard G. Dekany,
Tania Pereira Dominici,
Richard S. Ellis,
Charles D. Fisher,
James E. Gunn,
Timothy M. Heckman,
Paul T. P. Ho
, et al. (29 additional authors not shown)
Abstract:
The Prime Focus Spectrograph (PFS) of the Subaru Measurement of Images and Redshifts (SuMIRe) project has been endorsed by Japanese community as one of the main future instruments of the Subaru 8.2-meter telescope at Mauna Kea, Hawaii. This optical/near-infrared multi-fiber spectrograph targets cosmology with galaxy surveys, Galactic archaeology, and studies of galaxy/AGN evolution. Taking advanta…
▽ More
The Prime Focus Spectrograph (PFS) of the Subaru Measurement of Images and Redshifts (SuMIRe) project has been endorsed by Japanese community as one of the main future instruments of the Subaru 8.2-meter telescope at Mauna Kea, Hawaii. This optical/near-infrared multi-fiber spectrograph targets cosmology with galaxy surveys, Galactic archaeology, and studies of galaxy/AGN evolution. Taking advantage of Subaru's wide field of view, which is further extended with the recently completed Wide Field Corrector, PFS will enable us to carry out multi-fiber spectroscopy of 2400 targets within 1.3 degree diameter. A microlens is attached at each fiber entrance for F-ratio transformation into a larger one so that difficulties of spectrograph design are eased. Fibers are accurately placed onto target positions by positioners, each of which consists of two stages of piezo-electric rotary motors, through iterations by using back-illuminated fiber position measurements with a wide-field metrology camera. Fibers then carry light to a set of four identical fast-Schmidt spectrographs with three color arms each: the wavelength ranges from 0.38 μm to 1.3 μm will be simultaneously observed with an average resolving power of 3000. Before and during the era of extremely large telescopes, PFS will provide the unique capability of obtaining spectra of 2400 cosmological/astrophysical targets simultaneously with an 8-10 meter class telescope. The PFS collaboration, led by IPMU, consists of USP/LNA in Brazil, Caltech/JPL, Princeton, & JHU in USA, LAM in France, ASIAA in Taiwan, and NAOJ/Subaru.
△ Less
Submitted 9 October, 2012;
originally announced October 2012.
-
EAGLE ISS - A modular twin-channel integral-field near-IR spectrograph
Authors:
P. R. Hastings,
B. Stobie,
S. Vives,
P. Vola,
M. Wells,
C. J. Evans
Abstract:
The ISS (Integral-field Spectrograph System) has been designed as part of the EAGLE Phase A Instrument Study for the E-ELT. It consists of two input channels of 1.65x1.65 arcsec field-of-view, each reconfigured spatially by an image-slicing integral-field unit to feed a single near-IR spectrograph using cryogenic volume-phase-holographic (VPH) gratings to disperse the image spectrally. A 4k x 4k a…
▽ More
The ISS (Integral-field Spectrograph System) has been designed as part of the EAGLE Phase A Instrument Study for the E-ELT. It consists of two input channels of 1.65x1.65 arcsec field-of-view, each reconfigured spatially by an image-slicing integral-field unit to feed a single near-IR spectrograph using cryogenic volume-phase-holographic (VPH) gratings to disperse the image spectrally. A 4k x 4k array detector array records the dispersed images. The optical design employs anamorphic magnification, image slicing, VPH gratings scanned with a novel cryo-mechanism and a three-lens camera. The mechanical implementation features IFU optics in Zerodur, a modular bench structure and a number of high-precision cryo-mechanisms.
△ Less
Submitted 9 July, 2010;
originally announced July 2010.
-
An original image slicer designed for Integral Field Spectroscopy with NIRSpec/JSWT
Authors:
Sébastien Vivès,
Eric Prieto
Abstract:
Integral Field Spectroscopy (IFS) provides a spectrum simultaneously for each spatial sample of an extended, two-dimensional field. It consists of an Integral Field Unit (IFU) which slices and re-arranges the initial field along the entrance slit of a spectrograph. This article presents an original design of IFU based on the advanced image slicer concept. To reduce optical aberrations, pupil and…
▽ More
Integral Field Spectroscopy (IFS) provides a spectrum simultaneously for each spatial sample of an extended, two-dimensional field. It consists of an Integral Field Unit (IFU) which slices and re-arranges the initial field along the entrance slit of a spectrograph. This article presents an original design of IFU based on the advanced image slicer concept. To reduce optical aberrations, pupil and slit mirrors are disposed in a fan-shaped configuration that means that angles between incident and reflected beams on each elements are minimized. The fan-shaped image slicer improves image quality in terms of wavefront error by a factor 2 comparing with classical image slicer and, furthermore it guaranties a negligible level of differential aberration in the field. As an exemple, we are presenting the design LAM used for its proposal at the NIRSPEC/IFU invitation of tender.
△ Less
Submitted 1 December, 2005;
originally announced December 2005.
-
Modeling a Slicer Mirror Using Zemax User-Defined Surface
Authors:
Sébastien Vivès,
Eric Prieto,
Gil Moretto,
Michel Saisse
Abstract:
A slicer mirror is a complex surface composed by many tilted and decentered mirrors sub-surfaces. The major difficulty to model such a complex surface is the large number of parameters used to define it. The Zemax's multi-configuration mode is usually used to specify each parameters (tilts, curvatures, decenters) for each mirror sub-surface which are then considered independently. Otherwise maki…
▽ More
A slicer mirror is a complex surface composed by many tilted and decentered mirrors sub-surfaces. The major difficulty to model such a complex surface is the large number of parameters used to define it. The Zemax's multi-configuration mode is usually used to specify each parameters (tilts, curvatures, decenters) for each mirror sub-surface which are then considered independently. Otherwise making use of the User-Defined Surface (UDS-DLL) Zemax capability, we are able to consider the set of sub-surfaces as a whole surface. In this paper, we present such a UDS-DLL tool comparing its performance with those of the classical multi-configuration mode. In particular, we explore the use of UDS-DLL to investigate the cross-talk due to the diffraction on the slicer array mirrors which has been a burden task when using multi-configuration mode.
△ Less
Submitted 19 October, 2005;
originally announced October 2005.