-
First results on dark matter annual modulation from ANAIS-112 experiment
Authors:
J. Amaré,
S. Cebrián,
I. Coarasa,
C. Cuesta,
E. García,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
J. Puimedón,
A. Salinas,
M. L. Sarsa,
P. Villar,
J. A. Villar
Abstract:
ANAIS is a direct detection dark matter experiment aiming at the testing of the DAMA/LIBRA annual modulation result, which standing for about two decades has neither been confirmed nor ruled out by any other experiment in a model independent way. ANAIS-112, consisting of 112.5 kg of sodium iodide crystals, is taking data at the Canfranc Underground Laboratory, Spain, since August 2017. This letter…
▽ More
ANAIS is a direct detection dark matter experiment aiming at the testing of the DAMA/LIBRA annual modulation result, which standing for about two decades has neither been confirmed nor ruled out by any other experiment in a model independent way. ANAIS-112, consisting of 112.5 kg of sodium iodide crystals, is taking data at the Canfranc Underground Laboratory, Spain, since August 2017. This letter presents the annual modulation analysis of 1.5 years of data, amounting to 157.55 kg$\times$y. We focus on the model independent analysis searching for modulation and the validation of our sensitivity prospects. ANAIS-112 data are consistent with the null hypothesis (p-values of 0.65 and 0.16 for [2-6] and [1-6] keV energy regions, respectively). The best fits for the modulation hypothesis are consistent with the absence of modulation ($S_m$=-0.0044$\pm$0.0058 cpd/kg/keV and -0.0015$\pm$0.0063 cpd/kg/keV, respectively). They are in agreement with our estimated sensitivity for the accumulated exposure, supporting our projected goal of reaching a 3$σ$ sensitivity to the DAMA/LIBRA result in 5 years of data taking.
△ Less
Submitted 10 March, 2019;
originally announced March 2019.
-
ANAIS-112 sensitivity in the search for dark matter annual modulation
Authors:
I. Coarasa,
J. Amaré,
S. Cebrián,
C. Cuesta,
E. García,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
J. Puimedón,
A. Salinas,
M. L. Sarsa,
P. Villar,
J. A. Villar
Abstract:
The annual modulation measured by the DAMA/LIBRA experiment can be explained by the interaction of dark matter WIMPs in NaI(Tl) scintillator detectors. Other experiments, with different targets or techniques, exclude the region of parameters singled out by DAMA/LIBRA, but the comparison of their results relies on several hypotheses regarding the dark matter model. ANAIS-112 is a dark matter search…
▽ More
The annual modulation measured by the DAMA/LIBRA experiment can be explained by the interaction of dark matter WIMPs in NaI(Tl) scintillator detectors. Other experiments, with different targets or techniques, exclude the region of parameters singled out by DAMA/LIBRA, but the comparison of their results relies on several hypotheses regarding the dark matter model. ANAIS-112 is a dark matter search with 112.5 kg of NaI(Tl) scintillators at the Canfranc Underground Laboratory (LSC) to test the DAMA/LIBRA result in a model independent way. We analyze its prospects in terms of the a priori critical and detection limits of the experiment. A simple figure of merit has been obtained to compare the different experiments looking for the annual modulation observed by DAMA/LIBRA. We conclude that after 5 years of measurement, ANAIS-112 can detect the annual modulation in the 3$σ$ region compatible with the DAMA/LIBRA result.
△ Less
Submitted 11 March, 2019; v1 submitted 4 December, 2018;
originally announced December 2018.
-
Performance of ANAIS-112 experiment after the first year of data taking
Authors:
J. Amaré,
S. Cebrián,
I. Coarasa,
C. Cuesta,
E. García,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
J. Puimedón,
A. Salinas,
M. L. Sarsa,
P. Villar,
J. A. Villar
Abstract:
ANAIS is a direct detection dark matter experiment aiming at the study of the annual modulation expected in the interaction rate. It uses same target and technique than DAMA/LIBRA experiment, which reported a highly significant positive modulation compatible with that expected for dark matter particles distributed in the galactic halo. However, other very sensitive experiments do not find any hint…
▽ More
ANAIS is a direct detection dark matter experiment aiming at the study of the annual modulation expected in the interaction rate. It uses same target and technique than DAMA/LIBRA experiment, which reported a highly significant positive modulation compatible with that expected for dark matter particles distributed in the galactic halo. However, other very sensitive experiments do not find any hint of particles with the required properties, although comparison is model dependent. In 2017, ANAIS-112 experiment was installed at the Canfranc Underground Laboratory (LSC), in Spain, and after the commissioning run for calibration and general assessment, ANAIS-112 started data taking in dark matter mode on August 3$^{rd}$, 2017. It consists of nine NaI(Tl) modules, amounting 112.5 kg of mass in total. ANAIS-112 will be able to test the DAMA/LIBRA result with the achieved background and threshold at three sigma level in five years of data taking. Here we report on the experimental apparatus and detector performance after the first year of data taking. Total live time available amounts to 341.72 days, being the corresponding exposure 105.32 kg x yr.
△ Less
Submitted 11 March, 2019; v1 submitted 4 December, 2018;
originally announced December 2018.
-
Analysis of backgrounds for the ANAIS-112 dark matter experiment
Authors:
J. Amare,
S. Cebrian,
I. Coarasa,
C. Cuesta,
E. Garcia,
M. Martinez,
M. A. Olivan,
Y. Ortigoza,
A. Ortiz de Solorzano,
J. Puimedon,
A. Salinas,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation or refutation of theDAMA/LIBRA positive annual modulation signal in the low energy detection rate, using the same target and technique, at the Canfranc Underground Laboratory (LSC) in Spain. ANAIS-112, consisting of nine 12.5 kg NaI(Tl) modules produced by Alpha Spectra Inc. in a 3x3matrix configuration, i…
▽ More
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation or refutation of theDAMA/LIBRA positive annual modulation signal in the low energy detection rate, using the same target and technique, at the Canfranc Underground Laboratory (LSC) in Spain. ANAIS-112, consisting of nine 12.5 kg NaI(Tl) modules produced by Alpha Spectra Inc. in a 3x3matrix configuration, is taking data smoothly in "dark matter search" mode since August, 2017, after a commissioning phase and operation of the first detectors during the last years in various setups. A large effort has been carried out withinANAIS to characterize the background of sodium iodide detectors, before unblinding the data and performing the first annual modulation analysis. Here, the background models developed for all the nine ANAIS-112 detectors are presented. Measured spectra from threshold to high energy in different conditions are well described by the models based on quantified activities independently estimated following several approaches. In the region from 1 to 6 keVee the measured, efficiency corrected background level is 3.58+-0.02 keV-1 kg-1 day-1; NaI crystal bulk contamination is the dominant background source being 210Pb, 40K, 22Na and 3H contributions the most relevant ones. This background level, added to the achieved 1 keVee analysis threshold (thanks to the outstanding light collection and robust filtering procedures developed), allow ANAIS-112 to be sensitive to the modulation amplitude measured by DAMA/LIBRA, and able to explore at three sigma level in 5 years the WIMP parameter region singled out by this experiment.
△ Less
Submitted 28 May, 2019; v1 submitted 4 December, 2018;
originally announced December 2018.
-
The ANAIS-112 experiment at the Canfranc Underground Laboratory
Authors:
J Amare,
S Cebrian,
I Coarasa,
C Cuesta,
E Garcia,
M Martinez,
M A Olivan,
Y Ortigoza,
A Ortiz de Solorzano,
J Puimedon,
A Salinas,
M L Sarsa,
P Villar,
J A Villar
Abstract:
The ANAIS experiment aims at the confirmation of the DAMA/LIBRA signal at the Canfranc Underground Laboratory (LSC). Several 12.5 kg NaI(Tl) modules produced by Alpha Spectra Inc. have been operated there during the last years in various set-ups; an outstanding light collection at the level of 15 photoelectrons per keV, which allows triggering at 1 keV of visible energy, has been measured for all…
▽ More
The ANAIS experiment aims at the confirmation of the DAMA/LIBRA signal at the Canfranc Underground Laboratory (LSC). Several 12.5 kg NaI(Tl) modules produced by Alpha Spectra Inc. have been operated there during the last years in various set-ups; an outstanding light collection at the level of 15 photoelectrons per keV, which allows triggering at 1 keV of visible energy, has been measured for all of them and a complete characterization of their background has been achieved. In the first months of 2017, the full ANAIS-112 set-up consisting of nine Alpha Spectra detectors with a total mass of 112.5 kg was commissioned at LSC and the first dark matter run started in August, 2017. Here, the latest results on the detectors performance and measured background from the commissioning run will be presented and the sensitivity prospects of the ANAIS-112 experiment will be discussed.
△ Less
Submitted 10 October, 2017;
originally announced October 2017.
-
Radiopurity assessment of the energy readout for the NEXT double beta decay experiment
Authors:
S. Cebrián,
J. Pérez,
I. Bandac,
L. Labarga,
V. Álvarez,
C. D. R. Azevedo,
J. M. Benlloch-Rodríguez,
F. I. G. M. Borges,
A. Botas,
S. Cárcel,
J. V. Carrión,
C. A. N. Conde,
J. Díaz,
M. Diesburg,
J. Escada,
R. Esteve,
R. Felkai,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
A. Goldschmidt,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez
, et al. (45 additional authors not shown)
Abstract:
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) experiment intends to investigate the neutrinoless double beta decay of 136Xe, and therefore requires a severe suppression of potential backgrounds. An extensive material screening and selection process was undertaken to quantify the radioactivity of the materials used in the experiment. Separate energy and tracking readout planes…
▽ More
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) experiment intends to investigate the neutrinoless double beta decay of 136Xe, and therefore requires a severe suppression of potential backgrounds. An extensive material screening and selection process was undertaken to quantify the radioactivity of the materials used in the experiment. Separate energy and tracking readout planes using different sensors allow us to combine the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. The design of radiopure readout planes, in direct contact with the gas detector medium, was especially challenging since the required components typically have activities too large for experiments demanding ultra-low background conditions. After studying the tracking plane, here the radiopurity control of the energy plane is presented, mainly based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterráneo de Canfranc (Spain). All the available units of the selected model of photomultiplier have been screened together with most of the components for the bases, enclosures and windows. According to these results for the activity of the relevant radioisotopes, the selected components of the energy plane would give a contribution to the overall background level in the region of interest of at most 2.4 x 10-4 counts keV-1 kg-1 y-1, satisfying the sensitivity requirements of the NEXT experiment.
△ Less
Submitted 21 August, 2017; v1 submitted 19 June, 2017;
originally announced June 2017.
-
Cosmogenic production of tritium in dark matter detectors
Authors:
J. Amare,
J. Castel,
S. Cebrian,
I. Coarasa,
C. Cuesta,
T. Dafni,
J. Galan,
E. Garcia,
J. G. Garza,
F. J. Iguaz,
I. G. Irastorza,
G. Luzon,
M. Martinez,
H. Mirallas,
M. A. Olivan,
Y. Ortigoza,
A. Ortiz de Solorzano,
J. Puimedon,
E. Ruiz-Choliz,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
The direct detection of dark matter particles requires ultra-low background conditions at energies below a few tens of keV. Radioactive isotopes are produced via cosmogenic activation in detectors and other materials and those isotopes constitute a background source which has to be under control. In particular, tritium is specially relevant due to its decay properties (very low endpoint energy and…
▽ More
The direct detection of dark matter particles requires ultra-low background conditions at energies below a few tens of keV. Radioactive isotopes are produced via cosmogenic activation in detectors and other materials and those isotopes constitute a background source which has to be under control. In particular, tritium is specially relevant due to its decay properties (very low endpoint energy and long half-life) when induced in the detector medium, and because it can be generated in any material as a spallation product. Quantification of cosmogenic production of tritium is not straightforward, neither experimentally nor by calculations. In this work, a method for the calculation of production rates at sea level has been developed and applied to some of the materials typically used as targets in dark matter detectors (germanium, sodium iodide, argon and neon); it is based on a selected description of tritium production cross sections over the entire energy range of cosmic nucleons. Results have been compared to available data in the literature, either based on other calculations or from measurements. The obtained tritium production rates, ranging from a few tens to a few hundreds of nuclei per kg and per day at sea level, point to a significant contribution to the background in dark matter experiments, requiring the application of specific protocols for target material purification, material storing underground and limiting the time the detector is on surface during the building process in order to minimize the exposure to the most dangerous cosmic ray components.
△ Less
Submitted 24 November, 2017; v1 submitted 19 June, 2017;
originally announced June 2017.
-
Annual modulation of dark matter: The ANAIS-112 case
Authors:
I. Coarasa,
J. Amaré,
S. Cebrián,
C. Cuesta,
E. García,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
J. Puimedón,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
The annual modulation measured by the DAMA/LIBRA experiment can be explained by the interaction of dark matter WIMPs in NaI(Tl) scintillator detectors. Other experiments, with different targets or techniques, exclude the region of parameters singled out by DAMA/LIBRA, but the comparison of their results relies on several hypotheses regarding the dark matter model. ANAIS-112 is a dark matter search…
▽ More
The annual modulation measured by the DAMA/LIBRA experiment can be explained by the interaction of dark matter WIMPs in NaI(Tl) scintillator detectors. Other experiments, with different targets or techniques, exclude the region of parameters singled out by DAMA/LIBRA, but the comparison of their results relies on several hypotheses regarding the dark matter model. ANAIS-112 is a dark matter search with 112.5 kg of NaI(Tl) scintillators under commissioning at the Canfranc Underground Laboratory (LSC) to test the DAMA/LIBRA result in a model independent way. We analyze its prospects in terms of the a priori critical and detection limits of the experiment. The analysis is based on the detector response and the background level measured for the first modules operated in Canfranc.
△ Less
Submitted 22 April, 2017;
originally announced April 2017.
-
Light yield determination in large sodium iodide detectors applied in the search for dark matter
Authors:
M. A. Oliván,
J. Amaré,
S. Cebrián,
C. Cuesta,
E. García,
M. Martínez,
Y. Ortigoza,
A. Ortiz de Solórzano,
C. Pobes,
J. Puimedón,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
Application of NaI(Tl) detectors in the search for galactic dark matter particles through their elastic scattering off the target nuclei is well motivated because of the long standing DAMA/LIBRA highly significant positive result on annual modulation, still requiring confirmation. For such a goal, it is mandatory to reach very low threshold in energy (at or below the keV level), very low radioacti…
▽ More
Application of NaI(Tl) detectors in the search for galactic dark matter particles through their elastic scattering off the target nuclei is well motivated because of the long standing DAMA/LIBRA highly significant positive result on annual modulation, still requiring confirmation. For such a goal, it is mandatory to reach very low threshold in energy (at or below the keV level), very low radioactive background (at a few counts/keV/kg/day), and high detection mass (at or above the 100 kg scale). One of the most relevant technical issues is the optimization of the crystal intrinsic scintillation light yield and the efficiency of the light collecting system for large mass crystals. In the frame of the ANAIS (Annual modulation with NaI Scintillators) dark matter search project large NaI(Tl) crystals from different providers coupled to two photomultiplier tubes (PMTs) have been tested at the Canfranc Underground Laboratory. In this paper we present the estimates of the NaI(Tl) scintillation light collected using full-absorption peaks at very low energy from external and internal sources emitting gammas/electrons, and single-photoelectron events populations selected by using very low energy pulses tails. Outstanding scintillation light collection at the level of 15~photoelectrons/keV can be reported for the final design and provider chosen for ANAIS detectors. Taking into account the Quantum Efficiency of the PMT units used, the intrinsic scintillation light yield in these NaI(Tl) crystals is above 40~photoelectrons/keV for energy depositions in the range from 3 up to 25~keV. This very high light output of ANAIS crystals allows triggering below 1~keV, which is very important in order to increase the sensitivity in the direct detection of dark matter.
△ Less
Submitted 3 March, 2017;
originally announced March 2017.
-
Assessment of backgrounds of the ANAIS experiment for dark matter direct detection
Authors:
J. Amare,
S. Cebrian,
C. Cuesta,
E. Garcia,
M. Martinez,
M. A. Olivan,
Y. Ortigoza,
A. Ortiz de Solorzano,
J. Puimedon,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
A large effort has been carried out to characterize the background of sodium iodide crystals within the ANAIS (Annual modulation with NaI Scintillators) project. In this paper, the background models developed for three 12.5-kg NaI(Tl) scintillators produced by Alpha Spectra Inc. and operated at the Canfranc Underground Laboratory are presented together with an evaluation of the background prospect…
▽ More
A large effort has been carried out to characterize the background of sodium iodide crystals within the ANAIS (Annual modulation with NaI Scintillators) project. In this paper, the background models developed for three 12.5-kg NaI(Tl) scintillators produced by Alpha Spectra Inc. and operated at the Canfranc Underground Laboratory are presented together with an evaluation of the background prospects for the full experiment. Measured spectra from threshold to high energy in different conditions are well described by the models based on quantified activities. At the region of interest, crystal bulk contamination is the dominant background source. Contributions from 210Pb, 40K, 22Na and 3H are the most relevant. Those from 40K and 22Na could be efficiently suppressed thanks to anticoincidence operation in a crystals matrix or inside a Liquid Scintillator Veto (LSV), while that from 210Pb has been reduced by improving crystal production methods and 3H production could be reduced by shielding against cosmic rays during production. Assuming the activities of the last characterized detector, for nine crystals with a total mass of 112.5 kg the expected background rate is 2.5 counts/(keV kg d) in the region from 1 to 4 keV, which could be reduced at 1.4 counts/(keV kg d) by using a LSV.
△ Less
Submitted 22 July, 2016; v1 submitted 19 April, 2016;
originally announced April 2016.
-
The ANAIS Dark Matter Project: Status and Prospects
Authors:
J. Amaré,
S. Cebrián,
C. Cuesta,
E. García,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
C. Pobes,
J. Puimedón,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA positive annual modulation signal using the same target and technique at the Canfranc Underground Laboratory (LSC). A first step, named ANAIS-25 (two 12.5 kg NaI(Tl) modules) taking data from December 2012 to February 2015, provided interesting outcomes: very high light collection efficie…
▽ More
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA positive annual modulation signal using the same target and technique at the Canfranc Underground Laboratory (LSC). A first step, named ANAIS-25 (two 12.5 kg NaI(Tl) modules) taking data from December 2012 to February 2015, provided interesting outcomes: very high light collection efficiency, that could allow to lower the analysis energy threshold down to the level of 1 keVee, and a good understanding of the different background components, in particular the cosmogenic activated isotopes in the crystal bulk and other radioactive contaminations of the NaI crystal/powder. But those prototypes clearly pointed to the need for improved crystal radiopurity, in particular for $^{210}$Pb contamination. Since then, improvements in the purification and growing procedures in order to reduce background in the very low energy region have been implemented and a new 12.5 kg module has been constructed and installed between the former two crystals, forming the ANAIS-37 setup. Very preliminary results of this setup evidence the improvement on radiopurity of the new crystal and are presented here. In addition, background simulations and prospects for the full experiment are discussed.
△ Less
Submitted 6 January, 2016;
originally announced January 2016.
-
Status of the ANAIS Dark Matter Project at the Canfranc Underground Laboratory
Authors:
J. Amaré,
S. Cebrián,
C. Cuesta,
E. García,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
C. Pobes,
J. Puimedón,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA signal using the same target and technique at the Canfranc Underground Laboratory (LSC). Along 2016, 112.5 kg of ultra pure NaI(Tl) crystals will be installed at LSC in a 3x3 modules matrix configuration. The ANAIS-25 and ANAIS-37 set-ups have been taking data at the LSC testing the detec…
▽ More
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA signal using the same target and technique at the Canfranc Underground Laboratory (LSC). Along 2016, 112.5 kg of ultra pure NaI(Tl) crystals will be installed at LSC in a 3x3 modules matrix configuration. The ANAIS-25 and ANAIS-37 set-ups have been taking data at the LSC testing the detector performance, the DAQ and analysis systems, and assessing the background. Main results coming from both set-ups will be summarized in this paper, focusing on the excellent detector performance and background understanding. Prospects for the experiment will be also briefly revised.
△ Less
Submitted 14 December, 2015;
originally announced December 2015.
-
Background model of NaI(Tl) detectors for the ANAIS Dark Matter Project
Authors:
J. Amare,
S. Cebrian,
C. Cuesta,
E. Garcia,
M. Martinez,
M. A. Olivan,
Y. Ortigoza,
A. Ortiz de Solorzano,
C. Pobes,
J. Puimedon,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
A thorough understanding of the background sources is mandatory in any experiment searching for rare events. The ANAIS (Annual Modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA signal at the Canfranc Underground Laboratory (LSC). Two NaI(Tl) crystals of 12.5 kg each produced by Alpha Spectra have been taking data since December 2012. The complete backgrou…
▽ More
A thorough understanding of the background sources is mandatory in any experiment searching for rare events. The ANAIS (Annual Modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA signal at the Canfranc Underground Laboratory (LSC). Two NaI(Tl) crystals of 12.5 kg each produced by Alpha Spectra have been taking data since December 2012. The complete background model of these detectors and more precisely in the region of interest will be described. Preliminary background analysis of a new 12.5 kg crystal received at Canfranc in March 2015 will be presented too. Finally, the power of anticoincidence rejection in the region of interest has been analyzed in a 4x 5 12.5 kg detector matrix.
△ Less
Submitted 31 August, 2015;
originally announced August 2015.
-
Status of the ANAIS Dark Matter Project at the Canfranc Underground Laboratory
Authors:
J. Amare,
S. Cebrian,
C. Cuesta,
E. Garcia,
M. Martinez,
M. A. Olivan,
Y. Ortigoza,
A. Ortiz de Solorzano,
C. Pobes,
J. Puimedon,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
The ANAIS experiment aims at the confirmation of the DAMA/LIBRA signal. A detailed analysis of two NaI(Tl) crystals of 12.5 kg each grown by Alpha Spectra will be shown: effective threshold at 1 keVee is at reach thanks to outstanding light collection and robust PMT noise filtering protocols and the measured background is well understood down to 3 keVee, having quantified K, U and Th content and c…
▽ More
The ANAIS experiment aims at the confirmation of the DAMA/LIBRA signal. A detailed analysis of two NaI(Tl) crystals of 12.5 kg each grown by Alpha Spectra will be shown: effective threshold at 1 keVee is at reach thanks to outstanding light collection and robust PMT noise filtering protocols and the measured background is well understood down to 3 keVee, having quantified K, U and Th content and cosmogenic activation in the crystals. A new detector was installed in Canfranc in March 2015 together with the two previous modules and preliminary characterization results will be presented. Finally, the status and expected sensitivity of the full experiment with 112 kg will be reviewed.
△ Less
Submitted 28 August, 2015;
originally announced August 2015.
-
Light Collection in the Prototypes of the ANAIS Dark Matter Project
Authors:
Julio Amaré,
Susana Cebrián,
Clara Cuesta,
Eduardo García,
María Martínez,
Miguel A. Oliván,
Ysrael Ortigoza,
Alfonso Ortíz de Solórzano,
Carlos Pobes,
Jorge Puimedón,
María Luisa Sarsa,
José Ángel Villar,
Patricia Villar
Abstract:
The ANAIS experiment aims at the confirmation of the DAMA/LIBRA signal using the same target and technique at the Canfranc Underground Laboratory (LSC) in Spain. ANAIS detectors consist of large NaI crystals coupled to two photomultipliers (PMTs). In this work we present Single Electron Response (SER) data for several units of the Hamamatsu R12669SEL2 PMT model extracted from normal operation data…
▽ More
The ANAIS experiment aims at the confirmation of the DAMA/LIBRA signal using the same target and technique at the Canfranc Underground Laboratory (LSC) in Spain. ANAIS detectors consist of large NaI crystals coupled to two photomultipliers (PMTs). In this work we present Single Electron Response (SER) data for several units of the Hamamatsu R12669SEL2 PMT model extracted from normal operation data of ANAIS underground prototypes and we compare them with PMT SER characterization previously done at surface lab before coupling them to NaI crystal. Moreover, total light collection for different ANAIS prototypes has been calculated, producing an excellent average result of 15 phe/keV, which has a good impact in both energy resolution and threshold.
△ Less
Submitted 25 August, 2015;
originally announced August 2015.
-
First proof of topological signature in the high pressure xenon gas TPC with electroluminescence amplification for the NEXT experiment
Authors:
NEXT Collaboration,
P. Ferrario,
A. Laing,
N. López-March,
J. J. Gómez-Cadenas,
V. Álvarez,
C. D. R. Azevedo,
F. I. G. Borges,
S. Cárcel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
J. Díaz,
M. Diesburg,
R. Esteve,
L. M. P. Fernandes,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
D. González-Díaz,
R. M. Gutiérrez,
J. Hauptman,
C. A. O. Henriques
, et al. (45 additional authors not shown)
Abstract:
The NEXT experiment aims to observe the neutrinoless double beta decay of xenon in a high-pressure Xe136 gas TPC using electroluminescence (EL) to amplify the signal from ionization. One of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to Qbb. This paper presents the first demonstration that the topology provides extra handles t…
▽ More
The NEXT experiment aims to observe the neutrinoless double beta decay of xenon in a high-pressure Xe136 gas TPC using electroluminescence (EL) to amplify the signal from ionization. One of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to Qbb. This paper presents the first demonstration that the topology provides extra handles to reject background events using data obtained with the NEXT-DEMO prototype.
Single electrons resulting from the interactions of Na22 1275 keV gammas and electron-positron pairs produced by conversions of gammas from the Th228 decay chain were used to represent the background and the signal in a double beta decay. These data were used to develop algorithms for the reconstruction of tracks and the identification of the energy deposited at the end-points, providing an extra background rejection factor of 24.3 +- 1.4 (stat.)%, while maintaining an efficiency of 66.7 +- 1% for signal events.
△ Less
Submitted 18 January, 2016; v1 submitted 21 July, 2015;
originally announced July 2015.
-
Background analysis and status of the ANAIS dark matter project
Authors:
J. Amaré,
S. Cebrián,
C. Cuesta,
E. García,
C. Ginestra,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
C. Pobes,
J. Puimedón,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
ANAIS (Annual modulation with NaI Scintillators) is a project aiming to set up at the new facilities of the Canfranc Underground Laboratory (LSC), a large scale NaI(Tl) experiment in order to explore the DAMA/LIBRA annual modulation positive result using the same target and technique. Two 12.5 kg each NaI(Tl) crystals provided by Alpha Spectra took data at the LSC in the ANAIS-25 set-up. The compa…
▽ More
ANAIS (Annual modulation with NaI Scintillators) is a project aiming to set up at the new facilities of the Canfranc Underground Laboratory (LSC), a large scale NaI(Tl) experiment in order to explore the DAMA/LIBRA annual modulation positive result using the same target and technique. Two 12.5 kg each NaI(Tl) crystals provided by Alpha Spectra took data at the LSC in the ANAIS-25 set-up. The comparison of the background model for the ANAIS-25 prototypes with the experimental results is presented. ANAIS crystal radiopurity goals have been achieved for Th-232 and U-238 chains, but a Pb-210 contamination out-of-equilibrium was identified, whose origin has been studied. The high light collection efficiency obtained with these prototypes allows to anticipate an energy threshold of the order of 1 keVee. A new detector, with improved performances, was received in March 2015 and very preliminary results are shown.
△ Less
Submitted 10 June, 2015;
originally announced June 2015.
-
Radon and material radiopurity assessment for the NEXT double beta decay experiment
Authors:
S. Cebrián,
J. Pérez,
I. Bandac,
L. Labarga,
V. Álvarez,
A. I. Barrado,
A. Bettini,
F. I. G. M. Borges,
M. Camargo,
S. Cárcel,
A. Cervera,
C. A. N. Conde,
E. Conde,
T. Dafni,
J. Díaz,
R. Esteve,
L. M. P. Fernandes,
M. Fernández,
P. Ferrario,
E. D. C. Freitas,
L. M. P. Fernandes,
V. M. Gehman,
A. Goldschmidt,
J. J. Gómez-Cadenas,
D. González-Díaz
, et al. (46 additional authors not shown)
Abstract:
The Neutrino Experiment with a Xenon TPC (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in 136Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is un…
▽ More
The Neutrino Experiment with a Xenon TPC (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in 136Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is underway for several years based mainly on gamma-ray spectroscopy using ultra-low background germanium detectors in Canfranc but also on mass spectrometry techniques like GDMS and ICPMS. Components from shielding, pressure vessel, electroluminescence and high voltage elements and energy and tracking readout planes have been analyzed, hel** in the final design of the experiment and in the construction of the background model. The latest measurements carried out will be presented and the implication on NEXT of their results will be discussed. The commissioning of the NEW detector, as a first step towards NEXT, has started in Canfranc; in-situ measurements of airborne radon levels were taken there to optimize the system for radon mitigation and will be shown too.
△ Less
Submitted 26 May, 2015;
originally announced May 2015.
-
Production and relevance of cosmogenic radionuclides in NaI(Tl) crystals
Authors:
J. Amare,
S. Cebrian,
C. Cuesta,
E. Garcia,
C. Ginestra,
M. Martinez,
M. A. Olivan,
Y. Ortigoza,
A. Ortiz de Solorzano,
C. Pobes,
J. Puimedon,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
The cosmogenic production of long-lived radioactive isotopes in materials is an hazard for experiments demanding ultra-low background conditions. Although NaI(Tl) scintillators have been used in this context for a long time, very few activation data were available. We present results from two 12.5 kg NaI(Tl) detectors, developed within the ANAIS project and installed at the Canfranc Underground La…
▽ More
The cosmogenic production of long-lived radioactive isotopes in materials is an hazard for experiments demanding ultra-low background conditions. Although NaI(Tl) scintillators have been used in this context for a long time, very few activation data were available. We present results from two 12.5 kg NaI(Tl) detectors, developed within the ANAIS project and installed at the Canfranc Underground Laboratory. The prompt data taking starting made possible a reliable quantification of production of some I, Te and Na isotopes with half-lives larger than ten days. Initial activities underground were measured and then production rates at sea level were estimated following the history of detectors; a comparison of these rates with calculations using typical cosmic neutron flux at sea level and a selected description of excitation functions was also carried out. After including the contribution from the identified cosmogenic products in the detector background model, we found that the presence of 3H in the crystal bulk would help to fit much better our background model and experimental data. We have analyzed the cosmogenic production of 3H in NaI, and although precise quantification has not been attempted, we can conclude that it could imply a very relevant contribution to the total background below 15 keV in NaI detectors.
△ Less
Submitted 22 May, 2015;
originally announced May 2015.
-
Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atmospheres
Authors:
Diego Gonzalez-Diaz,
V. Alvarez,
F. I. G. Borges,
M. Camargo,
S. Carcel,
S. Cebrian,
A. Cervera,
C. A. N. Conde,
T. Dafni,
J. Diaz,
R. Esteve,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
J. J. Gomez-Cadenas,
R. M. Gutierrez,
J. Hauptman,
J. A. Hernando Morata,
D. C. Herrera,
I. G. Irastorza,
L. Labarga,
A. Laing
, et al. (58 additional authors not shown)
Abstract:
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in 1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3 +-0.13 mm-sigma (longitudinal)…
▽ More
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in 1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3 +-0.13 mm-sigma (longitudinal), 0.8 +-0.15 mm-sigma (transverse) along 1 m drift) besides forming a convenient Penning-Fluorescent mixture. The TPC, that houses 1.1 kg of gas in its active volume, operated continuously for 100 live-days in charge amplification mode. The readout was performed through the recently introduced microbulk Micromegas technology and the AFTER chip, providing a 3D voxelization of 8mm x 8mm x 1.2mm for approximately 10 cm/MeV-long electron tracks. This work was developed as part of the R&D program of the NEXT collaboration for future detector upgrades in the search of the 0bbnu decay in 136Xe, specifically those based on novel gas mixtures. Therefore we ultimately focus on the calorimetric and topological properties of the reconstructed MeV-electron tracks.
△ Less
Submitted 17 June, 2015; v1 submitted 14 April, 2015;
originally announced April 2015.
-
Search for chameleons with CAST
Authors:
V. Anastassopoulos,
M. Arik,
S. Aune,
K. Barth,
A. Belov,
H. Bräuninger,
G. Cantatore,
J. M. Carmona,
S. A. Cetin,
F. Christensen,
J. I. Collar,
T. Dafni,
M. Davenport,
K. Desch,
A. Dermenev,
C. Eleftheriadis,
G. Fanourakis,
E. Ferrer-Ribas,
P. Friedrich,
J. Galán,
J. A. García,
A. Gardikiotis,
J. G. Garza,
E. N. Gazis,
T. Geralis
, et al. (39 additional authors not shown)
Abstract:
In this work we present a search for (solar) chameleons with the CERN Axion Solar Telescope (CAST). This novel experimental technique, in the field of dark energy research, exploits both the chameleon coupling to matter ($β_{\rm m}$) and to photons ($β_γ$) via the Primakoff effect. By reducing the X-ray detection energy threshold used for axions from 1$\,$keV to 400$\,$eV CAST became sensitive to…
▽ More
In this work we present a search for (solar) chameleons with the CERN Axion Solar Telescope (CAST). This novel experimental technique, in the field of dark energy research, exploits both the chameleon coupling to matter ($β_{\rm m}$) and to photons ($β_γ$) via the Primakoff effect. By reducing the X-ray detection energy threshold used for axions from 1$\,$keV to 400$\,$eV CAST became sensitive to the converted solar chameleon spectrum which peaks around 600$\,$eV. Even though we have not observed any excess above background, we can provide a 95% C.L. limit for the coupling strength of chameleons to photons of $β_γ\!\lesssim\!10^{11}$ for $1<β_{\rm m}<10^6$.
△ Less
Submitted 18 March, 2016; v1 submitted 16 March, 2015;
originally announced March 2015.
-
ANAIS: Status and prospects
Authors:
Julio Amaré,
Susana Cebrián,
Clara Cuesta,
Eduardo García,
Carlos Ginestra,
María Martínez,
Miguel A. Oliván,
Ysrael Ortigoza,
Alfonso Ortíz de Solórzano,
Carlos Pobes,
Jorge Puimedón,
María Luisa Sarsa,
José Ángel Villar,
Patricia Villar
Abstract:
ANAIS experiment will look for dark matter annual modulation with large mass of ultra-pure NaI(Tl) scintillators at the Canfranc Underground Laboratory (LSC), aiming to confirm the DAMA/LIBRA positive signal in a model-independent way. Two 12.5 kg each NaI(Tl) crystals provided by Alpha Spectra are currently taking data at the LSC. Present status of ANAIS detectors background and general performan…
▽ More
ANAIS experiment will look for dark matter annual modulation with large mass of ultra-pure NaI(Tl) scintillators at the Canfranc Underground Laboratory (LSC), aiming to confirm the DAMA/LIBRA positive signal in a model-independent way. Two 12.5 kg each NaI(Tl) crystals provided by Alpha Spectra are currently taking data at the LSC. Present status of ANAIS detectors background and general performance is summarized; in particular, thanks to the high light collection efficiency prospects of lowering the threshold down to 1 keVee are reachable. Crystal radiopurity goals are fulfilled for $^{232}$Th and $^{238}$U chains and $^{40}$K activity, although higher than original goal, could be accepted; however, high $^{210}$Pb contamination out-of-equilibrium has been identified. More radiopure detectors are being built by Alpha Spectra. The ongoing high quantum efficiency PMT tests and muon veto characterization are also presented. Finally, the sensitivity of the experiment for the annual modulation in the WIMP signal, assuming the already achieved threshold and background in ANAIS-25 is shown. Further improvement should be achieved by reducing both threshold and background, as expected.
△ Less
Submitted 31 December, 2014;
originally announced January 2015.
-
An improved measurement of electron-ion recombination in high-pressure xenon gas
Authors:
NEXT Collaboration,
L. Serra,
M. Sorel,
V. Álvarez,
F. I. G. Borges,
M. Camargo,
S. Cárcel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
J. Díaz,
R. Esteve,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez,
J. Hauptman,
J. A. Hernando Morata,
D. C. Herrera
, et al. (42 additional authors not shown)
Abstract:
We report on results obtained with the NEXT-DEMO prototype of the NEXT-100 high-pressure xenon gas time projection chamber (TPC), exposed to an alpha decay calibration source. Compared to our previous measurements with alpha particles, an upgraded detector and improved analysis techniques have been used. We measure event-by-event correlated fluctuations between ionization and scintillation due to…
▽ More
We report on results obtained with the NEXT-DEMO prototype of the NEXT-100 high-pressure xenon gas time projection chamber (TPC), exposed to an alpha decay calibration source. Compared to our previous measurements with alpha particles, an upgraded detector and improved analysis techniques have been used. We measure event-by-event correlated fluctuations between ionization and scintillation due to electron-ion recombination in the gas, with correlation coeffcients between -0.80 and -0.56 depending on the drift field conditions. By combining the two signals, we obtain a 2.8 % FWHM energy resolution for 5.49 MeV alpha particles and a measurement of the optical gain of the electroluminescent TPC. The improved energy resolution also allows us to measure the specific activity of the radon in the gas due to natural impurities. Finally, we measure the average ratio of excited to ionized atoms produced in the xenon gas by alpha particles to be $0.561\pm 0.045$, translating into an average energy to produce a primary scintillation photon of $W_{\rm ex}=(39.2\pm 3.2)$ eV.
△ Less
Submitted 3 February, 2015; v1 submitted 11 December, 2014;
originally announced December 2014.
-
Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment
Authors:
S. Cebrián,
J. Pérez,
I. Bandac,
L. Labarga,
V. Álvarez,
A. I. Barrado,
A. Bettini,
F. I. G. M. Borges,
M. Camargo,
S. Cárcel,
A. Cervera,
C. A. N. Conde,
E. Conde,
T. Dafni,
J. Díaz,
R. Esteve,
L. M. P. Fernandes,
M. Fernández,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
J. J. Gómez-Cadenas,
D. González-Díaz
, et al. (46 additional authors not shown)
Abstract:
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radiopurity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the…
▽ More
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radiopurity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. Separate energy and tracking readout planes are based on different sensors: photomultiplier tubes for calorimetry and silicon multi-pixel photon counters for tracking. The design of a radiopure tracking plane, in direct contact with the gas detector medium, was specially challenging since the needed components like printed circuit boards, connectors, sensors or capacitors have typically, according to available information in databases and in the literature, activities too large for experiments requiring ultra-low background conditions. Here, the radiopurity assessment of tracking readout components based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterraneo de Canfranc (Spain) is described. According to the obtained results, radiopure enough printed circuit boards made of kapton and copper, silicon photomultipliers and other required components, fulfilling the requirement of an overall background level in the region of interest of at most 8 10-4 counts keV-1 kg-1 y-1, have been identified.
△ Less
Submitted 15 June, 2015; v1 submitted 5 November, 2014;
originally announced November 2014.
-
Results of the material screening program of the NEXT experiment
Authors:
T. Dafni,
V. Alvarez,
I. Bandac,
A. Bettini,
F. I. G. M. Borges,
M. Camargo,
S. Carcel,
S. Cebrian,
A. Cervera,
C. A. N. Conde,
J. Diaz,
R. Esteve,
L. M. P. Fernandes,
M. Fernandez,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Goldschmidt,
H. Gomez,
J. J. Gomez-Cadenas,
D. Gonzalez-Diaz,
R. M. Gutierrez,
J. Hauptman,
J. A. Hernando Morata
, et al. (45 additional authors not shown)
Abstract:
The 'Neutrino Experiment with a Xenon TPC (NEXT)', intended to investigate neutrinoless double beta decay, requires extremely low background levels. An extensive material screening and selection process to assess the radioactivity of components is underway combining several techniques, including germanium gamma-ray spectrometry performed at the Canfranc Underground Laboratory; recent results of th…
▽ More
The 'Neutrino Experiment with a Xenon TPC (NEXT)', intended to investigate neutrinoless double beta decay, requires extremely low background levels. An extensive material screening and selection process to assess the radioactivity of components is underway combining several techniques, including germanium gamma-ray spectrometry performed at the Canfranc Underground Laboratory; recent results of this material screening program are presented here.
△ Less
Submitted 5 November, 2014;
originally announced November 2014.
-
Cosmogenic radionuclide production in NaI(Tl) crystals
Authors:
J. Amaré,
S. Cebrián,
C. Cuesta,
E. García,
C. Ginestra,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
C. Pobes,
J. Puimedón,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
The production of long-lived radioactive isotopes in materials due to the exposure to cosmic rays on Earth surface can be an hazard for experiments demanding ultra-low background conditions, typically performed deep underground. Production rates of cosmogenic isotopes in all the materials present in the experimental set-up, as well as the corresponding cosmic rays exposure history, must be both we…
▽ More
The production of long-lived radioactive isotopes in materials due to the exposure to cosmic rays on Earth surface can be an hazard for experiments demanding ultra-low background conditions, typically performed deep underground. Production rates of cosmogenic isotopes in all the materials present in the experimental set-up, as well as the corresponding cosmic rays exposure history, must be both well known in order to assess the relevance of this effect in the achievable sensitivity of a given experiment. Although NaI(Tl) scintillators are being used in experiments aiming at the direct detection of dark matter since the first nineties of the last century, very few data about cosmogenic isotopes production rates have been published up to date. In this work we present data from two 12.5 kg NaI(Tl) detectors, developed in the frame of the ANAIS project, which were installed inside a convenient shielding at the Canfranc Underground Laboratory just after finishing surface exposure to cosmic rays. The very fast start of data taking allowed to identify and quantify isotopes with half-lives of the order of tens of days. Initial activities underground have been measured and then production rates at sea level have been estimated following the history of detectors; values of about a few tens of nuclei per kg and day for Te isotopes and 22Na and of a few hundreds for I isotopes have been found. These are the first direct estimates of production rates of cosmogenic nuclides in NaI crystals. A comparison of the so deduced rates with calculations using typical cosmic neutron flux at sea level and a carefully selected description of excitation functions will be also presented together with an estimate of the corresponding contribution to the background at low and high energies, which can be relevant for experiments aiming at rare events searches.
△ Less
Submitted 16 January, 2015; v1 submitted 1 November, 2014;
originally announced November 2014.
-
ANAIS: Status and prospects
Authors:
J. Amare,
S. Cebrian,
C. Cuesta,
E. Garcia,
C. Ginestra,
M. Martinez,
M. A. Olivan,
Y. Ortigoza,
A. Ortiz de Solorzano,
C. Pobes,
J. Puimedon,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
ANAIS (Annual modulation with NAI Scintillators) experiment aims to look for dark matter annual modulation with 250 kg of ultrapure NaI(Tl) scintillators at the Canfranc Underground Laboratory (LSC), in order to confirm the DAMA/LIBRA positive signal in a model-independent way. The detector will consist in an array of close-packed single modules, each of them coupled to two high efficiency Hamamat…
▽ More
ANAIS (Annual modulation with NAI Scintillators) experiment aims to look for dark matter annual modulation with 250 kg of ultrapure NaI(Tl) scintillators at the Canfranc Underground Laboratory (LSC), in order to confirm the DAMA/LIBRA positive signal in a model-independent way. The detector will consist in an array of close-packed single modules, each of them coupled to two high efficiency Hamamatsu photomultipliers. Two 12.5 kg each NaI(Tl) crystals provided by Alpha Spectra are currently taking data at the LSC. These modules have shown an outstanding light collection efficiency (12-16 phe/keV), about the double of that from DAMA/LIBRA phase 1 detectors, which could enable reducing the energy threshold down to 1 keVee. ANAIS crystal radiopurity goals are fulfilled for 232Th and 238U chains, assuming equilibrium, and in the case of 40K, present crystals activity (although not at the required 20 ppb level) could be acceptable. However, a 210Pb contamination out-of-equilibrium has been identified and its origin traced back, so we expect it will be avoided in next prototypes. Finally, current status and prospects of the experiment considering several exposure and background scenarios are presented.
△ Less
Submitted 22 October, 2014;
originally announced October 2014.
-
Ionization and scintillation of nuclear recoils in gaseous xenon
Authors:
J. Renner,
V. M. Gehman,
A. Goldschmidt,
H. S. Matis,
T. Miller,
Y. Nakajima,
D. Nygren,
C. A. B. Oliveira,
D. Shuman,
V. Álvarez,
F. I. G. Borges,
S. Cárcel,
J. Castel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas
, et al. (53 additional authors not shown)
Abstract:
Ionization and scintillation produced by nuclear recoils in gaseous xenon at approximately 14 bar have been simultaneously observed in an electroluminescent time projection chamber. Neutrons from radioisotope $α$-Be neutron sources were used to induce xenon nuclear recoils, and the observed recoil spectra were compared to a detailed Monte Carlo employing estimated ionization and scintillation yiel…
▽ More
Ionization and scintillation produced by nuclear recoils in gaseous xenon at approximately 14 bar have been simultaneously observed in an electroluminescent time projection chamber. Neutrons from radioisotope $α$-Be neutron sources were used to induce xenon nuclear recoils, and the observed recoil spectra were compared to a detailed Monte Carlo employing estimated ionization and scintillation yields for nuclear recoils. The ability to discriminate between electronic and nuclear recoils using the ratio of ionization to primary scintillation is demonstrated. These results encourage further investigation on the use of xenon in the gas phase as a detector medium in dark matter direct detection experiments.
△ Less
Submitted 9 September, 2014;
originally announced September 2014.
-
Bulk NaI(Tl) scintillation low energy events selection with the ANAIS-0 module
Authors:
C. Cuesta,
J. Amaré,
S. Cebrián,
E. García,
C. Ginestra,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
C. Pobes,
J. Puimedón,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
Dark matter particles scattering off some target nuclei are expected to deposit very small energies in form of nuclear recoils (below 100 keV). Because of the low scintillation efficiency for nuclear recoils vs. electron recoils, in most of the scintillating targets considered in the search for dark matter, the region below 10 keVee concentrates most of the expected dark matter signal. For this re…
▽ More
Dark matter particles scattering off some target nuclei are expected to deposit very small energies in form of nuclear recoils (below 100 keV). Because of the low scintillation efficiency for nuclear recoils vs. electron recoils, in most of the scintillating targets considered in the search for dark matter, the region below 10 keVee concentrates most of the expected dark matter signal. For this reason, very low energy threshold (at or below 2 keVee) and very low background are required. This is the case of the ANAIS (Annual modulation with NaI Scintillators) experiment. A good knowledge of the detector response function for real scintillation events, a good characterization of other anomalous or noise event populations contributing in that energy range, and the development of convenient filtering procedures for the latter are mandatory to achieve the required low background at such a low energy. In this work we will present the specific protocols developed to select bulk scintillation events in NaI(Tl), and its application to data obtained with the ANAIS-0 prototype. Slight differences in time constants are expected in scintillation pulses produced by nuclear or electron recoils in NaI(Tl), so in order to analyze the effect of these filtering procedures in the case of a recoil population attributable to dark matter, data from a neutron calibration have been used.
△ Less
Submitted 17 December, 2014; v1 submitted 18 July, 2014;
originally announced July 2014.
-
From ANAIS-25 towards ANAIS-250
Authors:
J. Amaré,
S. Cebrián,
C. Cuesta,
E. García,
C. Ginestra,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
C. Pobes,
J. Puimedón,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA signal using the same target and technique at the Canfranc Underground Laboratory (LSC). 250 kg of ultra pure NaI(Tl) crystals will be used as target, divided into 20 modules, 12.5 kg mass each, and coupled to two high efficiency photomultiplier tubes from Hamamatsu. The ANAIS-25 set-up a…
▽ More
The ANAIS (Annual modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA signal using the same target and technique at the Canfranc Underground Laboratory (LSC). 250 kg of ultra pure NaI(Tl) crystals will be used as target, divided into 20 modules, 12.5 kg mass each, and coupled to two high efficiency photomultiplier tubes from Hamamatsu. The ANAIS-25 set-up at the LSC consists of two prototypes, amounting 25 kg NaI(Tl), grown from a powder having a potassium level under the limit of our analytical techniques, and installed in a convenient shielding at the LSC. The background has been carefully analyzed and main results will be summarized in this paper, focusing on the alpha contamination identified in the prototypes and the related background contributions. Status of fulfillment of ANAIS experimental goals and prospects for the building of ANAIS-250 experiment will be also revised.
△ Less
Submitted 28 April, 2014; v1 submitted 14 April, 2014;
originally announced April 2014.
-
Analysis of the 40K contamination in NaI(Tl) crystals from different providers in the frame of the ANAIS project
Authors:
Clara Cuesta,
Julio Amaré,
Susana Cebrián,
Eduardo García,
Carlos Ginestra,
María Martínez,
Miguel A. Oliván,
Ysrael Ortigoza,
Alfonso Ortíz de Solórzano,
Carlos Pobes,
Jorge Puimedón,
María Luisa Sarsa,
José Ángel Villar,
Patricia Villar
Abstract:
NaI(Tl) large crystals are applied in the search for galactic dark matter particles through their elastic scattering off the target nuclei in the detector by measuring the scintillation signal produced. However, energies deposited in the form of nuclear recoils are small, which added to the low efficiency to convert that energy into scintillation, makes that events at or very near the energy thres…
▽ More
NaI(Tl) large crystals are applied in the search for galactic dark matter particles through their elastic scattering off the target nuclei in the detector by measuring the scintillation signal produced. However, energies deposited in the form of nuclear recoils are small, which added to the low efficiency to convert that energy into scintillation, makes that events at or very near the energy threshold, attributed either to radioactive backgrounds or to spurious noise (non-bulk NaI(Tl) scintillation events), can compromise the sensitivity goals of such an experiment. DAMA/LIBRA experiment, using 250 kg NaI(Tl) target, reported first evidence of the presence of an annual modulation in the detection rate compatible with that expected for a dark matter signal just in the region below 6 keVee (electron equivalent energy). In the frame of the ANAIS (Annual modulation with NaI Scintillators) dark matter search project a large and long effort has been carried out in order to understand the origin of events at very low energy in large sodium iodide detectors and develop convenient filters to reject those non attributable to scintillation in the bulk NaI(Tl) crystal. 40K is probably the most relevant radioactive contaminant in the bulk for NaI(Tl) detectors because of its important contribution to the background at very low energy. ANAIS goal is to achieve levels at or below 20 ppb natural potassium. In this paper we will report on our effort to determine the 40K contamination in several NaI(Tl) crystals, by measuring in coincidence between two (or more) of them. Results obtained for the 40K content of crystals from different providers will be compared and prospects of the ANAIS dark matter search experiment will be briefly reviewed.
△ Less
Submitted 14 March, 2014;
originally announced March 2014.
-
Conceptual Design of the International Axion Observatory (IAXO)
Authors:
E. Armengaud,
F. T. Avignone,
M. Betz,
P. Brax,
P. Brun,
G. Cantatore,
J. M. Carmona,
G. P. Carosi,
F. Caspers,
S. Caspi,
S. A. Cetin,
D. Chelouche,
F. E. Christensen,
A. Dael,
T. Dafni,
M. Davenport,
A. V. Derbin,
K. Desch,
A. Diago,
B. Döbrich,
I. Dratchnev,
A. Dudarev,
C. Eleftheriadis,
G. Fanourakis,
E. Ferrer-Ribas
, et al. (63 additional authors not shown)
Abstract:
The International Axion Observatory (IAXO) will be a forth generation axion helioscope. As its primary physics goal, IAXO will look for axions or axion-like particles (ALPs) originating in the Sun via the Primakoff conversion of the solar plasma photons. In terms of signal-to-noise ratio, IAXO will be about 4-5 orders of magnitude more sensitive than CAST, currently the most powerful axion heliosc…
▽ More
The International Axion Observatory (IAXO) will be a forth generation axion helioscope. As its primary physics goal, IAXO will look for axions or axion-like particles (ALPs) originating in the Sun via the Primakoff conversion of the solar plasma photons. In terms of signal-to-noise ratio, IAXO will be about 4-5 orders of magnitude more sensitive than CAST, currently the most powerful axion helioscope, reaching sensitivity to axion-photon couplings down to a few $\times 10^{-12}$ GeV$^{-1}$ and thus probing a large fraction of the currently unexplored axion and ALP parameter space. IAXO will also be sensitive to solar axions produced by mechanisms mediated by the axion-electron coupling $g_{ae}$ with sensitivity $-$for the first time$-$ to values of $g_{ae}$ not previously excluded by astrophysics. With several other possible physics cases, IAXO has the potential to serve as a multi-purpose facility for generic axion and ALP research in the next decade. In this paper we present the conceptual design of IAXO, which follows the layout of an enhanced axion helioscope, based on a purpose-built 20m-long 8-coils toroidal superconducting magnet. All the eight 60cm-diameter magnet bores are equipped with focusing x-ray optics, able to focus the signal photons into $\sim 0.2$ cm$^2$ spots that are imaged by ultra-low-background Micromegas x-ray detectors. The magnet is built into a structure with elevation and azimuth drives that will allow for solar tracking for $\sim$12 h each day.
△ Less
Submitted 14 January, 2014;
originally announced January 2014.
-
Study of scintillation in natural and synthetic quartz and methacrylate
Authors:
J. Amare,
S. Borjabad,
S. Cebrian,
C. Cuesta,
D. Fortuno,
E. Garcia,
C. Ginestra,
H. Gomez,
D. C. Herrera,
M. Martinez,
M. A. Olivan,
Y. Ortigoza,
A. Ortiz de Solorzano,
C. Pobes,
J. Puimedon,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
Samples from different materials typically used as optical windows or light guides in scintillation detectors were studied in a very low background environment, at the Canfranc Underground Laboratory, searching for scintillation. A positive result can be confirmed for natural quartz: two distinct scintillation components have been identified, not being excited by an external gamma source. Although…
▽ More
Samples from different materials typically used as optical windows or light guides in scintillation detectors were studied in a very low background environment, at the Canfranc Underground Laboratory, searching for scintillation. A positive result can be confirmed for natural quartz: two distinct scintillation components have been identified, not being excited by an external gamma source. Although similar effect has not been observed neither for synthetic quartz nor for methacrylate, a fast light emission excited by intense gamma flux is evidenced for all the samples in our measurements. These results could affect the use of these materials in low energy applications of scintillation detectors requiring low radioactive background conditions, as they entail a source of background.
△ Less
Submitted 27 March, 2014; v1 submitted 14 January, 2014;
originally announced January 2014.
-
Characterization of a medium size Xe/TMA TPC instrumented with microbulk Micromegas, using low-energy $γ$-rays
Authors:
The NEXT collaboration,
V. Alvarez,
F. I. G. M. Borges,
S. Carcel,
J. Castel,
S. Cebrian,
A. Cervera,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Diaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Gil,
A. Goldschmidt,
H. Gomez,
J. J. Gomez-Cadenas,
D. Gonzalez-Diaz,
R. M. Gutierrez
, et al. (65 additional authors not shown)
Abstract:
NEXT-MM is a general-purpose high pressure (10 bar, $\sim25$ l active volume) Xenon-based TPC, read out in charge mode with an 8 cm $\times$8 cm-segmented 700 cm$^2$ plane (1152 ch) of the latest microbulk-Micromegas technology. It has been recently commissioned at University of Zaragoza as part of the R&D of the NEXT $0νββ$ experiment, although the experiment's first stage is currently being buil…
▽ More
NEXT-MM is a general-purpose high pressure (10 bar, $\sim25$ l active volume) Xenon-based TPC, read out in charge mode with an 8 cm $\times$8 cm-segmented 700 cm$^2$ plane (1152 ch) of the latest microbulk-Micromegas technology. It has been recently commissioned at University of Zaragoza as part of the R&D of the NEXT $0νββ$ experiment, although the experiment's first stage is currently being built based on a SiPM/PMT-readout concept relying on electroluminescence. Around 2 million events were collected during the last months, stemming from the low energy $γ$-rays emitted by a $^{241}$Am source when interacting with the Xenon gas ($ε$ = 26, 30, 59.5 keV). The localized nature of such events above atmospheric pressure, the long drift times, as well as the possibility to determine their production time from the associated $α$ particle in coincidence, allow the extraction of primordial properties of the TPC filling gas, namely the drift velocity, diffusion and attachment coefficients. In this work we focus on the little explored combination of Xe and trimethylamine (TMA) for which, in particular, such properties are largely unknown. This gas mixture offers potential advantages over pure Xenon when aimed at Rare Event Searches, mainly due to its Penning characteristics, wave-length shifting properties and reduced diffusion, and it is being actively investigated by our collaboration. The chamber is currently operated at 2.7 bar, as an intermediate step towards the envisaged 10 bar. We report here its performance as well as a first implementation of the calibration procedures that have allowed the extension of the previously reported energy resolution to the whole readout plane (10.6%FWHM@30keV).
△ Less
Submitted 17 November, 2013; v1 submitted 14 November, 2013;
originally announced November 2013.
-
Description and commissioning of NEXT-MM prototype: first results from operation in a Xenon-Trimethylamine gas mixture
Authors:
NEXT Collaboration,
V. Álvarez,
F. Aznar,
F. I. G. M. Borges,
D. Calvet,
S. Cárcel,
J. Castel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
F. Druillole,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. Ferrer-Ribas,
E. D. C. Freitas,
V. M. Gehman,
A. Gil,
I. Giomataris
, et al. (60 additional authors not shown)
Abstract:
A technical description of NEXT-MM and its commissioning and first performance is reported. Having an active volume of ~35 cm drift $\times$ 28 cm diameter, it constitutes the largest Micromegas-read TPC operated in Xenon ever constructed, made by a sectorial arrangement of the 4 largest single wafers manufactured with the Microbulk technique to date. It is equipped with a suitably pixelized reado…
▽ More
A technical description of NEXT-MM and its commissioning and first performance is reported. Having an active volume of ~35 cm drift $\times$ 28 cm diameter, it constitutes the largest Micromegas-read TPC operated in Xenon ever constructed, made by a sectorial arrangement of the 4 largest single wafers manufactured with the Microbulk technique to date. It is equipped with a suitably pixelized readout and with a sufficiently large sensitive volume (~23 l) so as to contain long (~20 cm) electron tracks. First results obtained at 1 bar for Xenon and trimethylamine (Xe-(2 %)TMA) mixture are presented. The TPC can accurately reconstruct extended background tracks. An encouraging full-width half-maximum of 11.6 % was obtained for ~29 keV gammas without resorting to any data post-processing.
△ Less
Submitted 27 November, 2013; v1 submitted 13 November, 2013;
originally announced November 2013.
-
Preliminary results of ANAIS-25
Authors:
J. Amaré,
S. Cebrián,
C. Cuesta,
E. García,
C. Ginestra,
M. Martínez,
M. A. Oliván,
Y. Ortigoza,
A. Ortiz de Solórzano,
C. Pobes,
J. Puimedón,
M. L. Sarsa,
P. Villar,
J. A. Villar
Abstract:
The ANAIS (Annual Modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA signal using the same target and technique at the Canfranc Underground Laboratory. 250 kg of ultrapure NaI(Tl) crystals will be used as a target, divided into 20 modules, each coupled to two photomultipliers. Two NaI(Tl) crystals of 12.5 kg each, grown by Alpha Spectra from a powder havin…
▽ More
The ANAIS (Annual Modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA signal using the same target and technique at the Canfranc Underground Laboratory. 250 kg of ultrapure NaI(Tl) crystals will be used as a target, divided into 20 modules, each coupled to two photomultipliers. Two NaI(Tl) crystals of 12.5 kg each, grown by Alpha Spectra from a powder having a potassium level under the limit of our analytical techniques, form the ANAIS-25 set-up. The background contributions are being carefully studied and preliminary results are presented: their natural potassium content in the bulk has been quantified, as well as the uranium and thorium radioactive chains presence in the bulk through the discrimination of the corresponding alpha events by PSA, and due to the fast commissioning, the contribution from cosmogenic activated isotopes is clearly identified and their decay observed along the first months of data taking. Following the procedures established with ANAIS-0 and previous prototypes, bulk NaI(Tl) scintillation events selection and light collection efficiency have been also studied in ANAIS-25.
△ Less
Submitted 15 August, 2013;
originally announced August 2013.
-
Present status and future perspectives of the NEXT experiment
Authors:
The NEXT Collaboration,
J. J. Gómez-Cadenas,
V. Álvarez,
F. I. G. M. Borges,
S. Cárcel,
J. Castel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Gil,
A. Goldschmidt,
H. Gómez,
D. González-Díaz,
R. M. Gutiérrez
, et al. (52 additional authors not shown)
Abstract:
NEXT is an experiment dedicated to neutrinoless double beta decay searches in xenon. The detector is a TPC, holding 100 kg of high-pressure xenon enriched in the $^{136}$Xe isotope. It is under construction in the Laboratorio Subterráneo de Canfranc in Spain, and it will begin operations in 2015. The NEXT detector concept provides an energy resolution better than 1% FWHM and a topological signal t…
▽ More
NEXT is an experiment dedicated to neutrinoless double beta decay searches in xenon. The detector is a TPC, holding 100 kg of high-pressure xenon enriched in the $^{136}$Xe isotope. It is under construction in the Laboratorio Subterráneo de Canfranc in Spain, and it will begin operations in 2015. The NEXT detector concept provides an energy resolution better than 1% FWHM and a topological signal that can be used to reduce the background. Furthermore, the NEXT technology can be extrapolated to a 1-ton scale experiment.
△ Less
Submitted 29 July, 2013; v1 submitted 15 July, 2013;
originally announced July 2013.
-
Slow scintillation time constants in NaI(Tl) for different interacting particles
Authors:
C. Cuesta,
M. A. Oliván,
J. Amaré,
S. Cebrián,
E. García,
C. Ginestra,
M. Martínez,
Y. Ortigoza,
A. Ortiz de Solórzano,
C. Pobes,
J. Puimedón,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
Very large thallium doped sodium iodide crystals operated underground and in very low background environment in the context of a dark matter search experiment have been used to determine scintillation components in the tens of ms range in the light pulse induced by different interacting particles: gammas/muons and alphas.
Very large thallium doped sodium iodide crystals operated underground and in very low background environment in the context of a dark matter search experiment have been used to determine scintillation components in the tens of ms range in the light pulse induced by different interacting particles: gammas/muons and alphas.
△ Less
Submitted 4 July, 2013;
originally announced July 2013.
-
Operation and first results of the NEXT-DEMO prototype using a silicon photomultiplier tracking array
Authors:
The NEXT Collaboration,
V. Álvarez,
F. I. G. Borges,
S. Cárcel,
J. Castel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Gil,
A. Goldschmidt,
H. Gómez,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez
, et al. (53 additional authors not shown)
Abstract:
NEXT-DEMO is a high-pressure xenon gas TPC which acts as a technological test-bed and demonstrator for the NEXT-100 neutrinoless double beta decay experiment. In its current configuration the apparatus fully implements the NEXT-100 design concept. This is an asymmetric TPC, with an energy plane made of photomultipliers and a tracking plane made of silicon photomultipliers (SiPM) coated with TPB. T…
▽ More
NEXT-DEMO is a high-pressure xenon gas TPC which acts as a technological test-bed and demonstrator for the NEXT-100 neutrinoless double beta decay experiment. In its current configuration the apparatus fully implements the NEXT-100 design concept. This is an asymmetric TPC, with an energy plane made of photomultipliers and a tracking plane made of silicon photomultipliers (SiPM) coated with TPB. The detector in this new configuration has been used to reconstruct the characteristic signature of electrons in dense gas. Demonstrating the ability to identify the MIP and "blob" regions. Moreover, the SiPM tracking plane allows for the definition of a large fiducial region in which an excellent energy resolution of 1.82% FWHM at 511 keV has been measured (a value which extrapolates to 0.83% at the xenon Qbetabeta).
△ Less
Submitted 7 June, 2013; v1 submitted 3 June, 2013;
originally announced June 2013.
-
CAST constraints on the axion-electron coupling
Authors:
K. Barth,
A. Belov,
B. Beltran,
H. Brauninger,
J. M. Carmona,
J. I. Collar,
T. Dafni,
M. Davenport,
L. Di Lella,
C. Eleftheriadis,
J. Englhauser,
G. Fanourakis,
E. Ferrer Ribas,
H. Fischer,
J. Franz,
P. Friedrich,
J. Galan,
J. A. Garcia,
T. Geralis,
I. Giomataris,
S. Gninenko,
H. Gomez,
M. D. Hassinoff,
F. H. Heinsius,
D. H. H. Hoffmann
, et al. (31 additional authors not shown)
Abstract:
In non-hadronic axion models, which have a tree-level axion-electron interaction, the Sun produces a strong axion flux by bremsstrahlung, Compton scattering, and axio-recombination, the "BCA processes." Based on a new calculation of this flux, including for the first time axio-recombination, we derive limits on the axion-electron Yukawa coupling g_ae and axion-photon interaction strength g_ag usin…
▽ More
In non-hadronic axion models, which have a tree-level axion-electron interaction, the Sun produces a strong axion flux by bremsstrahlung, Compton scattering, and axio-recombination, the "BCA processes." Based on a new calculation of this flux, including for the first time axio-recombination, we derive limits on the axion-electron Yukawa coupling g_ae and axion-photon interaction strength g_ag using the CAST phase-I data (vacuum phase). For m_a < 10 meV/c2 we find g_ag x g_ae< 8.1 x 10^-23 GeV^-1 at 95% CL. We stress that a next-generation axion helioscope such as the proposed IAXO could push this sensitivity into a range beyond stellar energy-loss limits and test the hypothesis that white-dwarf cooling is dominated by axion emission.
△ Less
Submitted 19 April, 2013; v1 submitted 25 February, 2013;
originally announced February 2013.
-
IAXO - The International Axion Observatory
Authors:
J. K. Vogel,
F. T. Avignone,
G. Cantatore,
J. M. Carmona,
S. Caspi,
S. A. Cetin,
F. E. Christensen,
A. Dael,
T. Dafni,
M. Davenport,
A. V. Derbin,
K. Desch,
A. Diago,
A. Dudarev,
C. Eleftheriadis,
G. Fanourakis,
E. Ferrer-Ribas,
J. Galan,
J. A. Garcia,
J. G. Garza,
T. Geralis,
B. Gimeno,
I. Giomataris,
S. Gninenko,
H. Gomez
, et al. (39 additional authors not shown)
Abstract:
The International Axion Observatory (IAXO) is a next generation axion helioscope aiming at a sensitivity to the axion-photon coupling of a few 10^{-12} GeV^{-1}, i.e. 1-1.5 orders of magnitude beyond sensitivities achieved by the currently most sensitive axion helioscope, the CERN Axion Solar Telescope (CAST). Crucial factors in improving the sensitivity for IAXO are the increase of the magnetic f…
▽ More
The International Axion Observatory (IAXO) is a next generation axion helioscope aiming at a sensitivity to the axion-photon coupling of a few 10^{-12} GeV^{-1}, i.e. 1-1.5 orders of magnitude beyond sensitivities achieved by the currently most sensitive axion helioscope, the CERN Axion Solar Telescope (CAST). Crucial factors in improving the sensitivity for IAXO are the increase of the magnetic field volume together with the extensive use of x-ray focusing optics and low background detectors, innovations already successfully tested at CAST. Electron-coupled axions invoked to explain the white dwarf cooling, relic axions, and a large variety of more generic axion-like particles (ALPs) along with other novel excitations at the low-energy frontier of elementary particle physics could provide additional physics motivation for IAXO.
△ Less
Submitted 13 February, 2013;
originally announced February 2013.
-
Initial results of NEXT-DEMO, a large-scale prototype of the NEXT-100 experiment
Authors:
NEXT Collaboration,
V. Álvarez,
F. I. G. M. Borges,
S. Cárcel,
J. Castel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Gil,
A. Goldschmidt,
H. Gómez,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez
, et al. (53 additional authors not shown)
Abstract:
NEXT-DEMO is a large-scale prototype of the NEXT-100 detector, an electroluminescent time projection chamber that will search for the neutrinoless double beta decay of Xe-136 using 100 to 150 kg of enriched xenon gas. NEXT-DEMO was built to prove the expected performance of NEXT-100, namely, energy resolution better than 1% FWHM at 2.5 MeV and event topological reconstruction. In this paper we des…
▽ More
NEXT-DEMO is a large-scale prototype of the NEXT-100 detector, an electroluminescent time projection chamber that will search for the neutrinoless double beta decay of Xe-136 using 100 to 150 kg of enriched xenon gas. NEXT-DEMO was built to prove the expected performance of NEXT-100, namely, energy resolution better than 1% FWHM at 2.5 MeV and event topological reconstruction. In this paper we describe the prototype and its initial results. A resolution of 1.75% FWHM at 511 keV (which extrapolates to 0.8% FWHM at 2.5 MeV) was obtained at 10 bar pressure using a gamma-ray calibration source. Also, a basic study of the event topology along the longitudinal coordinate is presented, proving that it is possible to identify the distinct dE/dx of electron tracks in high-pressure xenon using an electroluminescence TPC.
△ Less
Submitted 8 March, 2013; v1 submitted 20 November, 2012;
originally announced November 2012.
-
Near-Intrinsic Energy Resolution for 30 to 662 keV Gamma Rays in a High Pressure Xenon Electroluminescent TPC
Authors:
NEXT Collaboration,
V. Álvarez,
F. I. G. M. Borges,
S. Cárcel,
J. Castel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Gil,
A. Goldschmidt,
H. Gómez,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez
, et al. (53 additional authors not shown)
Abstract:
We present the design, data and results from the NEXT prototype for Double Beta and Dark Matter (NEXT-DBDM) detector, a high-pressure gaseous natural xenon electroluminescent time projection chamber (TPC) that was built at the Lawrence Berkeley National Laboratory. It is a prototype of the planned NEXT-100 $^{136}$Xe neutrino-less double beta decay ($0νββ$) experiment with the main objectives of d…
▽ More
We present the design, data and results from the NEXT prototype for Double Beta and Dark Matter (NEXT-DBDM) detector, a high-pressure gaseous natural xenon electroluminescent time projection chamber (TPC) that was built at the Lawrence Berkeley National Laboratory. It is a prototype of the planned NEXT-100 $^{136}$Xe neutrino-less double beta decay ($0νββ$) experiment with the main objectives of demonstrating near-intrinsic energy resolution at energies up to 662 keV and of optimizing the NEXT-100 detector design and operating parameters. Energy resolutions of $\sim$1% FWHM for 662 keV gamma rays were obtained at 10 and 15 atm and $\sim$5% FWHM for 30 keV fluorescence xenon X-rays. These results demonstrate that 0.5% FWHM resolutions for the 2,459 keV hypothetical neutrino-less double beta decay peak are realizable. This energy resolution is a factor 7 to 20 better than that of the current leading $0νββ$ experiments using liquid xenon and thus represents a significant advancement. We present also first results from a track imaging system consisting of 64 silicon photo-multipliers recently installed in NEXT-DBDM that, along with the excellent energy resolution, demonstrates the key functionalities required for the NEXT-100 $0νββ$ search.
△ Less
Submitted 19 November, 2012;
originally announced November 2012.
-
In-situ calibration of a PMT inside a scintillation detector by means of primary scintillation detection
Authors:
NEXT Collaboration,
V. Álvarez,
F. I. G. M. Borges,
S. Cárcel,
J. Castel,
S. Cebrián,
A. Cervera,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Gil,
A. Goldschmidt,
H. Gómez,
J. J. Gómez-Cadenas,
D. González-Díaz,
R. M. Gutiérrez
, et al. (53 additional authors not shown)
Abstract:
We have investigated the possibility of calibrating the PMTs of scintillation detectors, using the primary scintillation produced by X-rays to induce single photoelectron response of the PMT. The high-energy tail of this response, can be approximated to an exponential function, under some conditions. In these cases, it is possible to determine the average gain for each PMT biasing voltage from the…
▽ More
We have investigated the possibility of calibrating the PMTs of scintillation detectors, using the primary scintillation produced by X-rays to induce single photoelectron response of the PMT. The high-energy tail of this response, can be approximated to an exponential function, under some conditions. In these cases, it is possible to determine the average gain for each PMT biasing voltage from the inverse of the exponent of the exponential fit to the tail, which can be done even if the background and/or noise cover-up most of the distribution. We have compared our results with those obtained by the commonly used single electron response (SER) method, which uses a LED to induce a single photoelectron response of the PMT and determines the peak position of such response, relative to the pedestal peak (the electronic noise peak, which corresponds to 0 photoelectrons). The results of the exponential fit method agree with those obtained by the SER method when the average number of photoelectrons reaching the first dynode per light/scintillation pulse is around 1.0. The SER method has higher precision, while the exponential fit method has the advantage of being useful in situations where the PMT is already in situ, being difficult or even impossible to apply the SER method, e.g. in sealed scintillator/PMT devices.
△ Less
Submitted 19 November, 2012;
originally announced November 2012.
-
Radiopurity control in the NEXT-100 double beta decay experiment: procedures and initial measurements
Authors:
V. Alvarez,
I. Bandac,
A. Bettini,
F. I. G. M. Borges,
S. Carcel,
J. Castel,
S. Cebrian,
A. Cervera,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Diaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. D. C. Freitas,
V. M. Gehman,
A. Gil,
A. Goldschmidt,
H. Gomez,
J. J. Gomez-Cadenas,
D. Gonzalez-Diaz
, et al. (55 additional authors not shown)
Abstract:
The Neutrino Experiment with a Xenon TPC (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds. An extensive screening and material selection process is underway for NEXT since the control of the radiopurity levels of the materials to be used in the experimental set-up is a must for rare event searches. First mea…
▽ More
The Neutrino Experiment with a Xenon TPC (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds. An extensive screening and material selection process is underway for NEXT since the control of the radiopurity levels of the materials to be used in the experimental set-up is a must for rare event searches. First measurements based on Glow Discharge Mass Spectrometry and gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterráneo de Canfranc (Spain) are described here. Activity results for natural radioactive chains and other common radionuclides are summarized, being the values obtained for some materials like copper and stainless steel very competitive. The implications of these results for the NEXT experiment are also discussed.
△ Less
Submitted 25 January, 2013; v1 submitted 16 November, 2012;
originally announced November 2012.
-
Design and characterization of the SiPM tracking system of NEXT-DEMO, a demonstrator prototype of the NEXT-100 experiment
Authors:
NEXT Collaboration,
V. Álvarez,
M. Ball,
F. I. G. M. Borges,
S. Cárcel,
J. M. Carmona,
J. Castel,
J. M. Catalá,
S. Cebrián,
A. Cervera,
D. Chan,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. Ferrer-Ribas,
E. D. C. Freitas,
A. N. C. Garcia,
V. M. Gehman
, et al. (64 additional authors not shown)
Abstract:
NEXT-100 experiment aims at searching the neutrinoless double-beta decay of the Xe-136 isotope using a TPC filled with a 100 kg of high-pressure gaseous xenon, with 90% isotopic enrichment. The experiment will take place at the Laboratorio Subterráneo de Canfranc (LSC), Spain. NEXT-100 uses electroluminescence (EL) technology for energy measurement with a resolution better than 1% FWHM. The gaseou…
▽ More
NEXT-100 experiment aims at searching the neutrinoless double-beta decay of the Xe-136 isotope using a TPC filled with a 100 kg of high-pressure gaseous xenon, with 90% isotopic enrichment. The experiment will take place at the Laboratorio Subterráneo de Canfranc (LSC), Spain. NEXT-100 uses electroluminescence (EL) technology for energy measurement with a resolution better than 1% FWHM. The gaseous xenon in the TPC additionally allows the tracks of the two beta particles to be recorded, which are expected to have a length of up to 30 cm at 10 bar pressure. The ability to record the topological signature of the neutrinoless double-beta events provides a powerful background rejection factor for the double-beta experiment.
In this paper, we present a novel 3D imaging concept using SiPMs coated with tetraphenyl butadiene (TPB) for the EL read out and its first implementation in NEXT-DEMO, a large-scale prototype of the NEXT-100 experiment. The design and the first characterization measurements of the NEXT-DEMO SiPM tracking system are presented. The SiPM response uniformity over the tracking plane drawn from its gain map is shown to be better than 4%. An automated active control system for the stabilization of the SiPMs gain was developed, based on the voltage supply compensation of the gain drifts. The gain is shown to be stabilized within 0.2% relative variation around its nominal value, provided by Hamamatsu, in a temperature range of 10 degree C. The noise level from the electronics and the SiPM dark noise is shown to lay typically below the level of 10 photoelectrons (pe) in the ADC. Hence, a detection threshold at 10 pe is set for the acquisition of the tracking signals. The ADC full dynamic range (4096 channels) is shown to be adequate for signal levels of up to 200 pe/microsecond, which enables recording most of the tracking signals.
△ Less
Submitted 22 February, 2013; v1 submitted 27 June, 2012;
originally announced June 2012.
-
NEXT-100 Technical Design Report (TDR). Executive Summary
Authors:
NEXT Collaboration,
V. Álvarez,
F. I. G. M. Borges,
S. Cárcel,
J. M. Carmona,
J. Castel,
J. M. Catalá,
S. Cebrián,
A. Cervera,
D. Chan,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
M. Egorov,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira,
E. Ferrer-Ribas,
E. D. C. Freitas,
V. M. Gehman,
A. Gil,
I. Giomataris
, et al. (62 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the NEXT-100 detector that will search for neutrinoless double beta decay (bbonu) in Xe-136 at the Laboratorio Subterraneo de Canfranc (LSC), in Spain. The document formalizes the design presented in our Conceptual Design Report (CDR): an electroluminescence time projection chamber, with separate readout planes for calorimetry and tracking, located…
▽ More
In this Technical Design Report (TDR) we describe the NEXT-100 detector that will search for neutrinoless double beta decay (bbonu) in Xe-136 at the Laboratorio Subterraneo de Canfranc (LSC), in Spain. The document formalizes the design presented in our Conceptual Design Report (CDR): an electroluminescence time projection chamber, with separate readout planes for calorimetry and tracking, located, respectively, behind cathode and anode. The detector is designed to hold a maximum of about 150 kg of xenon at 15 bar, or 100 kg at 10 bar. This option builds in the capability to increase the total isotope mass by 50% while kee** the operating pressure at a manageable level.
The readout plane performing the energy measurement is composed of Hamamatsu R11410-10 photomultipliers, specially designed for operation in low-background, xenon-based detectors. Each individual PMT will be isolated from the gas by an individual, pressure resistant enclosure and will be coupled to the sensitive volume through a sapphire window. The tracking plane consists in an array of Hamamatsu S10362-11-050P MPPCs used as tracking pixels. They will be arranged in square boards holding 64 sensors (8 times8) with a 1-cm pitch. The inner walls of the TPC, the sapphire windows and the boards holding the MPPCs will be coated with tetraphenyl butadiene (TPB), a wavelength shifter, to improve the light collection.
△ Less
Submitted 16 April, 2012; v1 submitted 3 February, 2012;
originally announced February 2012.
-
The International Axion Observatory (IAXO)
Authors:
I. G. Irastorza,
F. T. Avignone,
G. Cantatore,
S. Caspi,
J. M. Carmona,
T. Dafni,
M. Davenport,
A. Dudarev,
G. Fanourakis,
E. Ferrer-Ribas,
J. Galan,
J. A. Garcia,
T. Geralis,
I. Giomataris,
S. Gninenko,
H. Gomez,
D. H. H. Hoffmann,
F. J. Iguaz,
K. Jakovcic,
M. Krcmar,
B. Lakic,
G. Luzon,
A. Lindner,
M. Pivovaroff,
T. Papaevangelou
, et al. (14 additional authors not shown)
Abstract:
The International Axion Observatory (IAXO) is a new generation axion helioscope aiming at a sensitivity to the axion-photon coupling of a few 10$^{12}$ GeV$^{-1}$, i.e. 1 - 1.5 orders of magnitude beyond the one currently achieved by CAST. The project relies on improvements in magnetic field volume together with extensive use of x-ray focusing optics and low background detectors, innovations alrea…
▽ More
The International Axion Observatory (IAXO) is a new generation axion helioscope aiming at a sensitivity to the axion-photon coupling of a few 10$^{12}$ GeV$^{-1}$, i.e. 1 - 1.5 orders of magnitude beyond the one currently achieved by CAST. The project relies on improvements in magnetic field volume together with extensive use of x-ray focusing optics and low background detectors, innovations already successfully tested in CAST. Additional physics cases of IAXO could include the detection of electron-coupled axions invoked to solve the white dwarfs anomaly, relic axions, and a large variety of more generic axion-like particles (ALPs) and other novel excitations at the low-energy frontier of elementary particle physics. This contribution is a summary of our paper [1] to which we refer for further details.
△ Less
Submitted 18 January, 2012;
originally announced January 2012.
-
SiPMs coated with TPB : coating protocol and characterization for NEXT
Authors:
V. Álvarez,
J. Agramunt,
M. Ball,
M. Batallé,
J. Bayarri,
F. I. G. Borges,
H. Bolink,
H. Brine,
S. Cárcel,
J. M. Carmona,
J. Castel,
J. M. Catalá,
S. Cebrián,
A. Cervera,
D. Chan,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
R. Esteve,
P. Evtoukhovitch,
J. Ferrando,
L. M. P. Fernandes,
P. Ferrario,
A. L. Ferreira
, et al. (69 additional authors not shown)
Abstract:
Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless ββ decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of event track and topology in this gaseous detector is a key handle for background rejection. Among the commercially available sensors that can be used for tracking, SiPMs off…
▽ More
Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless ββ decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of event track and topology in this gaseous detector is a key handle for background rejection. Among the commercially available sensors that can be used for tracking, SiPMs offer important advantages, mainly high gain, ruggedness, cost-effectiveness and radio-purity. Their main drawback, however, is their non sensitivity in the emission spectrum of the xenon scintillation (peak at 175 nm). This is overcome by coating these sensors with the organic wavelength shifter tetraphenyl butadienne (TPB). In this paper we describe the protocol developed for coating the SiPMs with TPB and the measurements performed for characterizing the coatings as well as the performance of the coated sensors in the UV-VUV range.
△ Less
Submitted 10 January, 2012;
originally announced January 2012.
-
The NEXT-100 experiment for neutrinoless double beta decay searches (Conceptual Design Report)
Authors:
NEXT Collaboration,
V. Álvarez,
M. Ball,
M. Batallé,
J. Bayarri,
F. I. G. Borges,
S. Cárcel,
J. M. Carmona,
J. Castel,
J. M. Catalá,
S. Cebrián,
A. Cervera-Villanueva,
D. Chan,
C. A. N. Conde,
T. Dafni,
T. H. V. T. Dias,
J. Díaz,
R. Esteve,
P. Evtoukhovitch,
L. M. P. Fernandes,
P. Ferrario,
E. Ferrer-Ribas,
A. L. Ferreira,
E. D. C. Freitas,
A. Gil
, et al. (58 additional authors not shown)
Abstract:
We propose an EASY (Electroluminescent ApparatuS of high Yield) and SOFT (Separated Optimized FuncTion) time-projection chamber for the NEXT experiment, that will search for neutrinoless double beta decay (bb0nu) in Xe-136. Our experiment must be competitive with the new generation of bb0nu searches already in operation or in construction. This requires a detector with very good energy resolution…
▽ More
We propose an EASY (Electroluminescent ApparatuS of high Yield) and SOFT (Separated Optimized FuncTion) time-projection chamber for the NEXT experiment, that will search for neutrinoless double beta decay (bb0nu) in Xe-136. Our experiment must be competitive with the new generation of bb0nu searches already in operation or in construction. This requires a detector with very good energy resolution (<1%), very low background con- tamination (1E-4 counts/(keV \bullet kg \bullet y)) and large target mass. In addition, it needs to be operational as soon as possible. The design described here optimizes energy resolution thanks to the use of proportional electroluminescent amplification (EL); it is compact, as the Xe gas is under high pressure; and it allows the measurement of the topological signature of the event to further reduce the background contamination. The SOFT design uses different sensors for tracking and calorimetry. We propose the use of SiPMs (MPPCs) coated with a suitable wavelength shifter for the tracking, and the use of radiopure photomultipliers for the measurement of the energy and the primary scintillation needed to estimate the t0. This design provides the best possible energy resolution compared with other NEXT designs based on avalanche gain devices. The baseline design is an Asymmetric Neutrino Gas EL apparatus (ANGEL), which was already outlined in the NEXT LOI. ANGEL is conceived to be easy to fabricate. It requires very little R&D and most of the proposed solutions have already been tested in the NEXT-1 prototypes. Therefore, the detector can be ready by 2013. In this Conceptual Design Report (CDR) we discuss first the physics case, present a full design of the detector, describe the NEXT-1 EL prototypes and their initial results, and outline a project to build a detector with 100 kg of enriched xenon to be installed in the Canfranc Underground Laboratory in 2013.
△ Less
Submitted 18 June, 2011;
originally announced June 2011.