-
Analysis of neutron time-of-flight spectra with a Bayesian unfolding methodology
Authors:
A. Pérez de Rada Fiol,
D. Cano-Ott,
T. Martínez,
V. Alcayne,
E. Mendoza,
J. Plaza,
A. Sanchez-Caballero,
D. Villamarín
Abstract:
We have developed an innovative methodology for obtaining the neutron energy distribution from a time-of-flight (TOF) measurement based on the iterative Bayesian unfolding method and accurate Monte Carlo simulations. This methodology has been validated through the analysis of a realistic virtual $β$-decay experiment, including the most relevant systematic effects in a real experiment. The proposed…
▽ More
We have developed an innovative methodology for obtaining the neutron energy distribution from a time-of-flight (TOF) measurement based on the iterative Bayesian unfolding method and accurate Monte Carlo simulations. This methodology has been validated through the analysis of a realistic virtual $β$-decay experiment, including the most relevant systematic effects in a real experiment. The proposed methodology allowed for obtaining accurate results over the energy range above the neutron detection threshold.
△ Less
Submitted 26 June, 2024; v1 submitted 30 January, 2024;
originally announced January 2024.
-
Commissioning of miniBELEN-10A, a moderated neutron counter with a flat efficiency for thick-target neutron yields measurements
Authors:
N Mont-Geli,
A Tarifeño-Saldivia,
L M Fraile,
S Viñals,
A Perea,
M Pallàs,
G Cortés,
G Garcia,
E Nácher,
J L Tain,
V Alcayne,
O Alonso-Sañudo,
A Algora,
J Balibrea-Correa,
J Benito,
M J G Borge,
J A Briz,
F Calviño,
D Cano-Ott,
A De Blas,
C Domingo-Pardo,
B Fernández,
R Garcia,
J Gómez-Camacho,
E M González-Romero
, et al. (18 additional authors not shown)
Abstract:
miniBELEN-10A is a modular and transportable moderated neutron counter with a nearly flat detection efficiency up to 8 MeV. The detector was designed to carry out measurements of (alpha, n) reactions in the context of the Measurement of Alpha Neutron Yields (MANY) project. In this work we present the results of the commissioning of miniBELEN-10A using the relatively well-known thick-target neutron…
▽ More
miniBELEN-10A is a modular and transportable moderated neutron counter with a nearly flat detection efficiency up to 8 MeV. The detector was designed to carry out measurements of (alpha, n) reactions in the context of the Measurement of Alpha Neutron Yields (MANY) project. In this work we present the results of the commissioning of miniBELEN-10A using the relatively well-known thick-target neutron yields from 27Al(alpha, n)30P.
△ Less
Submitted 14 April, 2023;
originally announced April 2023.
-
miniBELEN: a modular neutron counter for (alpha,n) reactions
Authors:
N Mont-Geli,
A Tarifeño-Saldivia,
L M Fraile,
S Viñals,
A Perea,
M Pallàs,
G Cortés,
E Nácher,
J L Tain,
V Alcayne,
A Algora,
J Balibrea-Correa,
J Benito,
M J G Borge,
J A Briz,
F Calviño,
D Cano-Ott,
A De Blas,
C Domingo-Pardo,
B Fernández,
R Garcia,
G García,
J Gómez-Camacho,
E M González-Romero,
C Guerrero
, et al. (16 additional authors not shown)
Abstract:
miniBELEN is a modular and transportable neutron moderated counter with a nearly flat neutron detection efficiency up to 10 MeV. Modularity implies that the moderator can be reassembled in different ways in order to obtain different types of response. The detector has been developed in the context of the Measurement of Alpha Neutron Yields (MANY) collaboration, which is a scientific effort aiming…
▽ More
miniBELEN is a modular and transportable neutron moderated counter with a nearly flat neutron detection efficiency up to 10 MeV. Modularity implies that the moderator can be reassembled in different ways in order to obtain different types of response. The detector has been developed in the context of the Measurement of Alpha Neutron Yields (MANY) collaboration, which is a scientific effort aiming to carry out measurements of (alpha,n) production yields, reaction cross-sections and neutron energy spectra. In this work we present and discuss several configurations of the miniBELEN detector. The experimental validation of the efficiency calculations using 252Cf sources and the measurement of the 27Al(alpha,n)30P reaction is also presented.
△ Less
Submitted 14 April, 2023;
originally announced April 2023.
-
Characterization of a CLYC detector for underground experiments
Authors:
T. Martinez,
A. Pérez de Rada,
D. Cano-Ott,
R. Santorelli,
I. Bandac,
P. Garcia Abia,
A. R. Garcia,
A. Ianni,
B. Montes,
L. Romero,
D. Villamarin
Abstract:
Large size detectors based on Cs2LiYCl6:Ce (CLYC) are capable of performing a combined $γ$-ray and neutron spectrometry and constitute a promising technology for a wide range of applications in nuclear and high energy physics. Due to their novelty, the comprehensive characterization of the performance of individual CLYC detectors is of great importance for determining their range of applicability.…
▽ More
Large size detectors based on Cs2LiYCl6:Ce (CLYC) are capable of performing a combined $γ$-ray and neutron spectrometry and constitute a promising technology for a wide range of applications in nuclear and high energy physics. Due to their novelty, the comprehensive characterization of the performance of individual CLYC detectors is of great importance for determining their range of applicability. In this work we report on a wide series measurements performed with a commercial 2"x2" CLYC crystal. Good energy and timing resolution values of 4.7% (@ 662 keV) and 1340 ps (FWHM), respectively, were achieved, and a neutron/$γ$ separation figure of merit value of 4.2 was obtained. A dedicated measurement for investigating the intrinsic background of the detector was performed at the Laboratorio Subterráneo de Canfranc (Spain). It evidenced a sizeable contamination in the detector materials which poses limits in the use of CLYC in low background experiments. In addition, detailed Monte Carlo simulations with the GEANT4 toolkit were performed for modeling the response function of the CLYC detector to gamma-rays. An excellent agreement with the experimental data has been achieved.
△ Less
Submitted 6 October, 2017;
originally announced October 2017.
-
Measurement and analysis of the Am-243 neutron capture cross section at the n_TOF facility at CERN
Authors:
n_TOF Collaboration,
:,
E. Mendoza,
D. Cano-Ott,
C. Guerrero,
E. Berthoumieux,
U. Abbondanno,
G. Aerts,
F. Alvarez-Velarde,
S. Andriamonje,
J. Andrzejewski,
P. Assimakopoulos,
L. Audouin,
G. Badurek,
J. Balibrea,
P. Baumann,
F. Becvar,
F. Belloni,
F. Calvino,
M. Calviani,
R. Capote,
C. Carrapico,
A. Carrillo de Albornoz,
P. Cennini,
V. Chepel
, et al. (108 additional authors not shown)
Abstract:
Background:The design of new nuclear reactors and transmutation devices requires to reduce the present neutron cross section uncertainties of minor actinides. Purpose: Reduce the $^{243}$Am(n,$γ$) cross section uncertainty. Method: The $^{243}$Am(n,$γ$) cross section has been measured at the n_TOF facility at CERN with a BaF$_{2}$ Total Absorption Calorimeter, in the energy range between 0.7 eV an…
▽ More
Background:The design of new nuclear reactors and transmutation devices requires to reduce the present neutron cross section uncertainties of minor actinides. Purpose: Reduce the $^{243}$Am(n,$γ$) cross section uncertainty. Method: The $^{243}$Am(n,$γ$) cross section has been measured at the n_TOF facility at CERN with a BaF$_{2}$ Total Absorption Calorimeter, in the energy range between 0.7 eV and 2.5 keV. Results: The $^{243}$Am(n,$γ$) cross section has been successfully measured in the mentioned energy range. The resolved resonance region has been extended from 250 eV up to 400 eV. In the unresolved resonance region our results are compatible with one of the two incompatible capture data sets available below 2.5 keV. The data available in EXFOR and in the literature has been used to perform a simple analysis above 2.5 keV. Conclusions: The results of this measurement contribute to reduce the $^{243}$Am(n,$γ$) cross section uncertainty and suggest that this cross section is underestimated up to 25% in the neutron energy range between 50 eV and a few keV in the present evaluated data libraries.
△ Less
Submitted 4 December, 2014;
originally announced December 2014.
-
Reactivity monitoring using the area method for the subcritic al VENUS-F core within the framework of the FREYA Project
Authors:
N. Marie,
G. Lehaut,
J. L. Lecouey,
A. Billebaud,
S. Chabod,
X. Doligez,
F. R. Lecolley,
A. Kochetkov,
W. Uyttenhove,
G. Vittiglio,
J. Wagemans,
F. Mellier,
G. Ban,
H. E. Thyébault,
D. Villamarin
Abstract:
Accelerator-Driven Systems (ADS) could be employed to incinerate minor actinides and so partly contribute to answer the problem of nuclear waste management. An ADS consists of the coupling of a subcritical fast reactor to a particle accelerator via a heavy material spallation target. The on-line reactivity monitoring of such an ADS is a serious issue regarding its safety. In order to study the met…
▽ More
Accelerator-Driven Systems (ADS) could be employed to incinerate minor actinides and so partly contribute to answer the problem of nuclear waste management. An ADS consists of the coupling of a subcritical fast reactor to a particle accelerator via a heavy material spallation target. The on-line reactivity monitoring of such an ADS is a serious issue regarding its safety. In order to study the methodology of this monitoring, zero-power experimentswere undertaken at the GUINEVERE facility within the framework of the FP6-IP-EUROTRANS programme. Such experiments have been under completion within the FREYA FP7 project. The GUINEVERE facility is hosted at the SCK-CEN site in Mol (Belgium). It couples the VENUS-F subcritical fast core with the GENEPI-3C accelerator. The latter delivers a beam of deuterons, which are converted into 14-MeV neutrons via fusion reactions on a tritiated target. This paper presents one of the investigated methods for ADS on-line reactivity monitoring which has to be validated in the program of the FREYA project. It describes the results obtained when Pulsed Neutron Source experiments are analysed using the so called Area Method, in order to estimate the reactivity of a few sub-critical configurations of the VENUS-F reactor, around keff= 0.96. First the GUINEVERE facility is described. Then, following general considerations on the Area method, the results of its application to the neutron population time decrease spectra measured after a pulse by several fission chambers spread out over the whole reactor are discussed. Finally the reactivity values extracted are compared to the static reactivity values obtained using the Modified Source Multiplication (MSM) method.
△ Less
Submitted 5 June, 2013;
originally announced June 2013.