-
Lateral IBIC characterization of single crystal synthetic diamond detectors
Authors:
A. Lo Giudice,
P. Olivero,
C. Manfredotti,
M. Marinelli,
E. Milani,
F. Picollo,
G. Prestopino,
A. Re,
V. Rigato,
C. Verona,
G. Verona-Rinati,
E. Vittone
Abstract:
In order to evaluate the charge collection efficiency (CCE) profile of single-crystal diamond devices based on a p type/intrinsic/metal configuration, a lateral Ion Beam Induced Charge (IBIC) analysis was performed over their cleaved cross sections using a 2 MeV proton microbeam. CCE profiles in the depth direction were extracted from the cross-sectional maps at variable bias voltage. IBIC spectra…
▽ More
In order to evaluate the charge collection efficiency (CCE) profile of single-crystal diamond devices based on a p type/intrinsic/metal configuration, a lateral Ion Beam Induced Charge (IBIC) analysis was performed over their cleaved cross sections using a 2 MeV proton microbeam. CCE profiles in the depth direction were extracted from the cross-sectional maps at variable bias voltage. IBIC spectra relevant to the depletion region extending beneath the frontal Schottky electrode show a 100% CCE, with a spectral resolution of about 1.5%. The dependence of the width of the high efficiency region from applied bias voltage allows the constant residual do** concentration of the active region to be evaluated. The region where the electric field is absent shows an exponentially decreasing CCE profile, from which it is possible to estimate the diffusion length of the minority carriers by means of a drift-diffusion model.
△ Less
Submitted 25 August, 2016;
originally announced August 2016.
-
IBIC characterization of an ion-beam-micromachined multi-electrode diamond detector
Authors:
J. Forneris,
V. Grilj,
M. Jaksic,
A. Lo Giudice,
P. Olivero,
F. Picollo,
N. Skukan,
C. Verona,
G. Verona-Rinati,
E. Vittone
Abstract:
Deep Ion Beam Lithography (DIBL) has been used for the direct writing of buried graphitic regions in monocrystalline diamond with micrometric resolution. Aiming at the development and the characterization of a fully ion-beam-micromachined solid state ionization chamber, a device with interdigitated electrodes was fabricated by using a 1.8 MeV He+ ion microbeam scanning on a homoepitaxial, grown by…
▽ More
Deep Ion Beam Lithography (DIBL) has been used for the direct writing of buried graphitic regions in monocrystalline diamond with micrometric resolution. Aiming at the development and the characterization of a fully ion-beam-micromachined solid state ionization chamber, a device with interdigitated electrodes was fabricated by using a 1.8 MeV He+ ion microbeam scanning on a homoepitaxial, grown by chemical vapour deposition (CVD). In order to evaluate the ionizing-radiation-detection performance of the device, charge collection efficiency (CCE) maps were extracted from Ion Beam Induced Charge (IBIC) measurements carried out by probing different arrangements of buried microelectrodes. The analysis of the CCE maps allowed for an exhaustive evaluation of the detector features, in particular the individuation of the different role played by electrons and holes in the formation of the induced charge pulses. Finally, a comparison of the performances of the detector with buried graphitic electrodes with those relevant to conventional metallic surface electrodes evidenced the formation of a dead layer overlying the buried electrodes as a result of the fabrication process.
△ Less
Submitted 25 August, 2016;
originally announced August 2016.
-
Response of diamond detector sandwich to 14 MeV neutrons
Authors:
M. Osipenko,
M. Ripani,
G. Ricco,
B. Caiffi,
F. Pompili,
M. Pillon,
G. Verona-Rinati,
R. Cardarelli
Abstract:
In this paper we present the measurement of the response of 50 $μ$m thin diamond detectors to 14 MeV neutrons. Such neutrons are produced in fusion reactors and are of particular interest for ITER neutron diagnostics. Among semiconductor detectors diamond has properties most appropriate for harsh radiation and temperature conditions of a fusion reactor. However, 300-500 $μ$m thick diamond detector…
▽ More
In this paper we present the measurement of the response of 50 $μ$m thin diamond detectors to 14 MeV neutrons. Such neutrons are produced in fusion reactors and are of particular interest for ITER neutron diagnostics. Among semiconductor detectors diamond has properties most appropriate for harsh radiation and temperature conditions of a fusion reactor. However, 300-500 $μ$m thick diamond detectors suffer significant radiation damage already at neutron fluences of the order of $10^{14}$ n/cm$^2$. It is expected that a 50 $μ$m thick diamond will withstand a fluence of $>10^{16}$ n/cm$^2$. We tested two 50 $μ$m thick single crystal CVD diamonds, stacked to form a "sandwich" detector for coincidence measurements. The detector measured the conversion of 14 MeV neutrons, im**ing on one diamond, into $α$ particles which were detected in the second diamond in coincidence with nuclear recoil. For $^{12}C(n,α)^{9}Be$ reaction the total energy deposited in the detector gives access to the initial neutron energy value. The measured 14 MeV neutron detection sensitivity through this reaction by a detector of effective area 3$\times$3 mm$^2$ was $5\times 10^{-7}$ counts cm$^2$/n. This value is in good agreement with Geant4 simulations. The intrinsic energy resolution of the detector was found to be 240 keV FWHM which adds only 10 % to ITER's 14 MeV neutron energy spread.
△ Less
Submitted 2 November, 2015; v1 submitted 19 October, 2015;
originally announced October 2015.
-
Neutron spectrometer for fast nuclear reactors
Authors:
M. Osipenko,
M. Ripani,
G. Ricco,
B. Caiffi,
F. Pompili,
M. Pillon,
M. Angelone,
G. Verona-Rinati,
R. Cardarelli,
G. Mila,
S. Argiro
Abstract:
In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons im**ing on $^6$Li into $α$ and $t$ whose total energy comprises the initial neutron energy and the reaction $Q$-value. The $^6$LiF layer is sandwiched between two CVD diamo…
▽ More
In this paper we describe the development and first tests of a neutron spectrometer designed for high flux environments, such as the ones found in fast nuclear reactors. The spectrometer is based on the conversion of neutrons im**ing on $^6$Li into $α$ and $t$ whose total energy comprises the initial neutron energy and the reaction $Q$-value. The $^6$LiF layer is sandwiched between two CVD diamond detectors, which measure the two reaction products in coincidence. The spectrometer was calibrated at two neutron energies in well known thermal and 3 MeV neutron fluxes. The measured neutron detection efficiency varies from 4.2$\times 10^{-4}$ to 3.5$\times 10^{-8}$ for thermal and 3 MeV neutrons, respectively. These values are in agreement with Geant4 simulations and close to simple estimates based on the knowledge of the $^6$Li(n,$α$)$t$ cross section. The energy resolution of the spectrometer was found to be better than 100 keV when using 5 m cables between the detector and the preamplifiers.
△ Less
Submitted 25 May, 2015;
originally announced May 2015.
-
Test of a prototype neutron spectrometer based on diamond detectors in a fast reactor
Authors:
M. Osipenko,
F. Pompili,
M. Ripani,
M. Pillon,
G. Ricco,
B. Caiffi,
R. Cardarelli,
G. Verona-Rinati,
S. Argiro
Abstract:
A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a $^6$Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energ…
▽ More
A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a $^6$Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energy resolution. A fast coincidence between two crystals is used to reject background. The detector was read out using two different electronic chains connected to it by a few meters of cable. The first chain was based on conventional charge-sensitive amplifiers, the other used a custom fast charge amplifier developed for this purpose. The prototype has been tested at various neutron sources and showed its practicability. In particular, the detector was calibrated in a TRIGA thermal reactor (LENA laboratory, University of Pavia) with neutron fluxes of $10^8$ n/cm$^2$s and at the 3 MeV D-D monochromatic neutron source named FNG (ENEA, Rome) with neutron fluxes of $10^6$ n/cm$^2$s. The neutron spectrum measurement was performed at the TAPIRO fast research reactor (ENEA, Casaccia) with fluxes of 10$^9$ n/cm$^2$s. The obtained spectra were compared to Monte Carlo simulations, modeling detector response with MCNP and Geant4.
△ Less
Submitted 23 May, 2015;
originally announced May 2015.
-
Electroluminescence from a diamond device with ion-beam-micromachined buried graphitic electrodes
Authors:
J. Forneris,
A. Battiato,
D. Gatto Monticone,
F. Picollo,
G. Amato,
L. Boarino,
G. Brida,
I. P. Degiovanni,
E. Enrico,
M. Genovese,
E. Moreva,
P. Traina,
C. Verona,
G. Verona-Rinati,
P. Olivero
Abstract:
Focused MeV ion microbeams are suitable tools for the direct writing of conductive graphitic channels buried in an insulating diamond bulk, as demonstrated in previous works with the fabrication of multi-electrode ionizing radiation detectors and cellular biosensors. In this work we investigate the suitability of the fabrication method for the electrical excitation of colour centres in diamond. Di…
▽ More
Focused MeV ion microbeams are suitable tools for the direct writing of conductive graphitic channels buried in an insulating diamond bulk, as demonstrated in previous works with the fabrication of multi-electrode ionizing radiation detectors and cellular biosensors. In this work we investigate the suitability of the fabrication method for the electrical excitation of colour centres in diamond. Differently from photoluminescence, electroluminescence requires an electrical current flowing through the diamond sub-gap states for the excitation of the colour centres. With this purpose, buried graphitic electrodes with a spacing of 10 micrometers were fabricated in the bulk of a detector-grade CVD single-crystal diamond sample using a scanning 1.8 MeV He micro-beam. The current flowing in the gap region between the electrodes upon the application of a 250 V bias voltage was exploited as the excitation pump for the electroluminescence of different types of colour centres localized in the above-mentioned gap. The bright light emission was spatially mapped using a confocal optical microscopy setup. The spectral analysis of electroluminescence revealed the emission from neutrally-charged nitrogen-vacancy centres ($NV^0$, $λ_{ZPL}$ = 575 nm), as well as from cluster crystal dislocations (A-band, λ = 400-500 nm). Moreover, an electroluminescence signal with appealing spectral features (sharp emission at room temperature, low phonon sidebands) from He-related defects was detected ($λ_{ZPL}$ = 536.3 nm, $λ_{ZPL}$ = 560.5 nm); a low and broad peak around λ = 740 nm was also observed and tentatively ascribed to Si-V or GR1 centres. These results pose interesting future perspectives for the fabrication of electrically-stimulated single-photon emitters in diamond for applications in quantum optics and quantum cryptography.
△ Less
Submitted 29 July, 2014;
originally announced July 2014.
-
Measurement and modelling of anomalous polarity pulses in a multi-electrode diamond detector
Authors:
J. Forneris,
V. Grilj,
M. Jaksic,
P. Olivero,
F. Picollo,
N. Skukan,
C. Verona,
G. Verona-Rinati,
E. Vittone
Abstract:
In multi-electrode detectors, the motion of excess carriers generated by ionizing radiation induces charge pulses at the electrodes, whose intensities and polarities depend on the geometrical, electrostatic and carriers transport properties of the device. The resulting charge sharing effects may lead to bipolar currents, pulse height defects and anomalous polarity signals affecting the response of…
▽ More
In multi-electrode detectors, the motion of excess carriers generated by ionizing radiation induces charge pulses at the electrodes, whose intensities and polarities depend on the geometrical, electrostatic and carriers transport properties of the device. The resulting charge sharing effects may lead to bipolar currents, pulse height defects and anomalous polarity signals affecting the response of the device to ionizing radiation. This latter effect has recently attracted attention in commonly used detector materials, but different interpretations have been suggested, depending on the material, the geometry of the device and the nature of the ionizing radiation. In this letter, we report on the investigation in the formation of anomalous polarity pulses in a multi-electrode diamond detector with buried graphitic electrodes. In particular, we propose a purely electrostatic model based on the Shockley-Ramo-Gunn theory, providing a satisfactory description of anomalous pulses observed in charge collection efficiency maps measured by means of Ion Beam Induced Charge (IBIC) microscopy, and suitable for a general application in multi-electrode devices and detectors.
△ Less
Submitted 17 December, 2013;
originally announced December 2013.