Skip to main content

Showing 1–9 of 9 results for author: Velissaris, C

.
  1. Search for the Rare Decays KL->pi0pi0mu+mu- and KL->pi0pi0X0->pi0pi0mu+mu-

    Authors: KTeV Collaboration, E. Abouzaid, M. Arenton, A. R. Barker, L. Bellantoni, E. Blucher, G. J. Bock, E. Cheu, R. Coleman, M. D. Corcoran, B. Cox, A. R. Erwin, C. O. Escobar, A. Glazov, A. Golossanov, R. A. Gomes, P. Gouffon, Y. B. Hsiung, D. A. Jensen, R. Kessler, K. Kotera, A. Ledovskoy, P. L. McBride, E. Monnier, H. Nguyen , et al. (25 additional authors not shown)

    Abstract: The KTeV E799 experiment has conducted a search for the rare decays KL->pi0pi0mu+mu- and KL->pi0pi0X0->pi0pi0mu+mu-, where the X0 is a possible new neutral boson that was reported by the HyperCP experiment with a mass of (214.3 pm 0.5) MeV/c^{2}. We find no evidence for either decay. We obtain upper limits of Br(KL->pi0pi0X0->pi0pi0mu+mu-) < 1.0 x 10^{-10} and Br(KL->pi0pi0mu+mu-) < 9.2 x 10^{-11}… ▽ More

    Submitted 14 September, 2011; v1 submitted 24 May, 2011; originally announced May 2011.

    Report number: FERMILAB-PUB-11-224-PPD

    Journal ref: Phys.Rev.Lett107:201803,2011

  2. Search for the Rare Decay K_{L}\toπ^{0}π^{0}γ

    Authors: KTeV Collaboration, E. Abouzaid, M. Arenton, A. R. Barker, L. Bellantoni, E. Blucher, G. J. Bock, E. Cheu, R. Coleman, M. D. Corcoran, G. Corti, B. Cox, A. R. Erwin, C. O. Escobar, A. Glazov, A. Golossanov, R. A. Gomes, P. Gouffon, Y. B. Hsiung, D. A. Jensen, R. Kessler, K. Kotera, A. Ledovskoy, P. L. McBride, E. Monnier , et al. (27 additional authors not shown)

    Abstract: The KTeV E799 experiment has conducted a search for the rare decay $K_{L}\toπ^{0}π^{0}γ$ via the topology $K_{L}\toπ^{0}π^{0}_Dγ$ (where $π^0_D\toγe^+e^-$). Due to Bose statistics of the $π^0$ pair and the real nature of the photon, the $K_{L}\toπ^{0}π^{0}γ$ decay is restricted to proceed at lowest order by the CP conserving direct emission (DE) of an E2 electric quadrupole photon. The rate of t… ▽ More

    Submitted 6 October, 2008; v1 submitted 21 August, 2007; originally announced August 2007.

    Comments: six pages and six figures in the submission. Reformatted for Physics Review D

    Report number: FERMILAB-PUB-07-427-E

    Journal ref: Phys.Rev.D78:032014,2008

  3. Measurement of the Decay KL -> pi0 e+ e- gamma

    Authors: KTeV Collaboration, E. Abouzaid, M. Arenton, A. R. Barker, L. Bellantoni, E. Blucher, G. J. Bock, E. Cheu, R. Coleman, B. Cox, A. R. Erwin, C. O. Escobar, A. Glazov, A. Golossanov, R. A. Gomes, P. Gouffon, Y. B. Hsiung, D. A. Jensen, R. Kessler, Y. J. Kim, K. Kotera, A. Ledovskoy, P. L. McBride, E. Monnier, K. S. Nelson , et al. (26 additional authors not shown)

    Abstract: We report on a new measurement of the branching ratio B(KL -> pi0 e+ e- gamma) using the KTeV detector. This analysis uses the full KTeV data set collected from 1997 to 2000. We reconstruct 139 events over a background of 14, which results in B(KL -> pi0 e+ e- gamma) = (1.62 +/- 0.14 (stat) +/- 0.09 (syst)) x 10^{-8}. This result supersedes the earlier KTeV measurement of this branching ratio.

    Submitted 25 July, 2007; v1 submitted 27 June, 2007; originally announced June 2007.

    Comments: 6 pages, 7 figures, Submitted to Phys. Rev. D

    Journal ref: Phys.Rev.D76:052001,2007

  4. arXiv:physics/0506193  [pdf

    physics.ins-det hep-ex physics.acc-ph

    Ion Chamber Arrays for the Numi Beam at Fermilab

    Authors: D. Indurthy, Z. Pavlovic, R. Zwaska, R. Keisler, S. Mendoza, S. Kopp, M. Proga, D. Harris, A. Marchionni, J. Morfin, A. Erwin, H. **, C. Velissaris, M. Bishai, M. Diwan, B. Viren, D. Naples, D. Northacker, J. McDonald

    Abstract: The Neutrinos at the Main Injector (NuMI) beamline will deliver an intense muon neutrino beam by focusing a beam of mesons into a long evacuated decay volume. We have built 4 arrays of ionization chambers to monitor the neutrino beam direction and quality. The arrays are located at 4 stations downstream of the decay volume, and measure the remnant hadron beam and tertiary muons produced along wi… ▽ More

    Submitted 26 June, 2005; originally announced June 2005.

    Report number: Fermilab-05-108-AD

    Journal ref: Conf.Proc.C0505161:3892,2005

  5. Observation of the Decay Xi^0 --> Sigma^+ mu^- nu(bar)

    Authors: KTeV Collaboration, E. Abouzaid, T. Alexopoulos, M. Arenton, R. F. Barbosa, A. R. Barker, L. Bellantoni, A. Bellavance, E. Blucher, G. J. Bock, E. Cheu, R. Coleman, M. D. Corcoran, B. Cox, A. R. Erwin, C. O. Escobar, A. Glazov, A. Golossanov, R. A. Gomes, P. Gouffon, K. Hanagaki, Y. B. Hsiung, H. Huang, D. A. Jensen, R. Kessler , et al. (35 additional authors not shown)

    Abstract: The Xi^0 muon semi-leptonic decay has been observed for the first time with nine identified events using the KTeV beam line and detector at Fermilab. The decay is normalized to the Xi^0 beta decay mode and yields a value for the ratio of decay rates of $(1.8^{+0.7}_{-0.5}(stat.)\pm0.2(syst.))\times 10^{-2}$. This is in agreement with the SU(3) flavor symmetric quark model.

    Submitted 3 June, 2008; v1 submitted 27 April, 2005; originally announced April 2005.

    Comments: 4 pages, 4 figures; changed authors list, figure added

    Journal ref: Phys.Rev.Lett.95:081801,2005

  6. arXiv:physics/0501085  [pdf, ps, other

    physics.ins-det physics.gen-ph

    A time dependent solution for the operation of ion chambers in a high ionization background

    Authors: Christos Velissaris

    Abstract: We have derived a time dependent solution describing the development of space charge inside an ion chamber subjected to an externally caused ionization rate N. The solution enables the derivation of a formula that the operational parameters of the chamber must satisfy for saturation free operation. This formula contains a correction factor to account for the finite duration of the ionization rat… ▽ More

    Submitted 17 January, 2005; originally announced January 2005.

    Comments: 12 pages, 2 figures

  7. arXiv:physics/0405022  [pdf

    physics.acc-ph hep-ex physics.ins-det

    Ion Chambers for Monitoring the NuMI Neutrino Beam at FNAL

    Authors: D. Indurthy, R. Keisler, S. Kopp, S. Mendoza, M. Proga, Z. Pavlovich, R. Zwaska, D. Harris, A. Marchionni, J. Morfin, A. Erwin, H. **, C. Velissaris, D. Naples, D. Northacker, J. McDonald, M. Diwan, B. Viren

    Abstract: The Neutrinos at the Main Injector (NuMI) beamline will deliver an intense muon neutrino beam by focusing a beam of mesons into a long evacuated decay volume. The beam must be steered with 1 mRad angular accuracy toward the Soudan Underground Laboratory in northern Minnesota. We have built 4 arrays of ionization chambers to monitor the neutrino beam direction and quality. The arrays are located… ▽ More

    Submitted 5 May, 2004; originally announced May 2004.

    Comments: paper to appear in the proceedings of the 11th Beam Instrumentation Workshop, Oak Ridge, TN

    Journal ref: AIP Conf.Proc.732:332-340,2004

  8. Beam Tests of Ionization Chambers for the NuMI Neutrino Beam

    Authors: R. M. Zwaska, James Hall, Sacha E. Kopp, Marek Proga, Albert R. Erwin, Huican **, Christos Velissaris, Deborah A. Harris, Donna Naples, Jeffrey McDonald, David Northacker, Milind Diwan, Brett Viren

    Abstract: We have conducted tests at the Fermilab Booster of ionization chambers to be used as monitors of the NuMI neutrino beamline. The chambers were exposed to proton fluxes of up to 10$^{12}$ particles/cm$^2$/1.56$μ$s. We studied space charge effects which can reduce signal collection from the chambers at large charged particle beam intensities.

    Submitted 5 December, 2002; originally announced December 2002.

    Comments: submitted to IEEE Trans Nucl. Sci

    Journal ref: IEEETrans.Nucl.Sci.50:1129-1135,2003

  9. Ionization Chambers for Monitoring in High-Intensity Charged Particle Beams

    Authors: J. McDonald, D. Naples, C. Velissaris, A. Erwin, H. **, B. Viren, M. Diwan

    Abstract: Radiation-hard ionization chambers were tested using an intense electron beam from the accelerator test facility (ATF) at the Brookhaven National Laboratory (BNL). The detectors were designed to be used as the basic element for monitoring muons in the Main Injector Neutrino beamline (NuMI) at the Fermi National Accelerator Laboratory (FNAL). Measurements of linearity of response, voltage depende… ▽ More

    Submitted 30 May, 2002; v1 submitted 14 May, 2002; originally announced May 2002.

    Comments: 11 pages, 13 figures