Classification of Volatile Organic Compounds by Differential Mobility Spectrometry Based on Continuity of Alpha Curves
Authors:
Anton Rauhameri,
Angelo Robiños,
Osmo Anttalainen,
Timo Salpavaara,
Jussi Rantala,
Veikko Surakka,
Pasi Kallio,
Antti Vehkaoja,
Philipp Müller
Abstract:
Background: Classification of volatile organic compounds (VOCs) is of interest in many fields. Examples include but are not limited to medicine, detection of explosives, and food quality control. Measurements collected with electronic noses can be used for classification and analysis of VOCs. One type of electronic noses that has seen considerable development in recent years is Differential Mobili…
▽ More
Background: Classification of volatile organic compounds (VOCs) is of interest in many fields. Examples include but are not limited to medicine, detection of explosives, and food quality control. Measurements collected with electronic noses can be used for classification and analysis of VOCs. One type of electronic noses that has seen considerable development in recent years is Differential Mobility Spectrometry (DMS). DMS yields measurements that are visualized as dispersion plots that contain traces, also known as alpha curves. Current methods used for analyzing DMS dispersion plots do not usually utilize the information stored in the continuity of these traces, which suggests that alternative approaches should be investigated.
Results: In this work, for the first time, dispersion plots were interpreted as a series of measurements evolving sequentially. Thus, it was hypothesized that time-series classification algorithms can be effective for classification and analysis of dispersion plots. An extensive dataset of 900 dispersion plots for five chemicals measured at five flow rates and two concentrations was collected. The data was used to analyze the classification performance of six algorithms. According to our hypothesis, the highest classification accuracy of 88\% was achieved by a Long-Short Term Memory neural network, which supports our hypothesis.
Significance: A new concept for approaching classification tasks of dispersion plots is presented and compared with other well-known classification algorithms. This creates a new angle of view for analysis and classification of the dispersion plots. In addition, a new dataset of dispersion plots is openly shared to public.
△ Less
Submitted 13 March, 2024; v1 submitted 13 January, 2024;
originally announced January 2024.
-
A benchmark for computational analysis of animal behavior, using animal-borne tags
Authors:
Benjamin Hoffman,
Maddie Cusimano,
Vittorio Baglione,
Daniela Canestrari,
Damien Chevallier,
Dominic L. DeSantis,
Lorène Jeantet,
Monique A. Ladds,
Takuya Maekawa,
Vicente Mata-Silva,
Víctor Moreno-González,
Eva Trapote,
Outi Vainio,
Antti Vehkaoja,
Ken Yoda,
Katherine Zacarian,
Ari Friedlaender
Abstract:
Animal-borne sensors ('bio-loggers') can record a suite of kinematic and environmental data, which can elucidate animal ecophysiology and improve conservation efforts. Machine learning techniques are used for interpreting the large amounts of data recorded by bio-loggers, but there exists no common framework for comparing the different machine learning techniques in this domain. To address this, w…
▽ More
Animal-borne sensors ('bio-loggers') can record a suite of kinematic and environmental data, which can elucidate animal ecophysiology and improve conservation efforts. Machine learning techniques are used for interpreting the large amounts of data recorded by bio-loggers, but there exists no common framework for comparing the different machine learning techniques in this domain. To address this, we present the Bio-logger Ethogram Benchmark (BEBE), a collection of datasets with behavioral annotations, as well as a modeling task and evaluation metrics. BEBE is to date the largest, most taxonomically diverse, publicly available benchmark of this type, and includes 1654 hours of data collected from 149 individuals across nine taxa. In addition, using BEBE, we test a novel self-supervised learning approach to identifying animal behaviors based on bio-logger data, using a deep neural network pre-trained with self-supervision on data collected from human wrist-worn accelerometers. We show that this approach out-performs common alternatives, especially in a setting with a low amount of training data. Datasets, models, and evaluation code are made publicly available at https://github.com/earthspecies/BEBE, to enable community use of BEBE as a point of comparison in methods development.
△ Less
Submitted 10 April, 2024; v1 submitted 18 May, 2023;
originally announced May 2023.
-
Signal-to-noise ratio is more important than sampling rate in beat-to-beat interval estimation from optical sensors
Authors:
Sebastian Zaunseder,
Antti Vehkaoja,
Vincent Fleischhauer,
Christoph Hoog Antink
Abstract:
Photoplethysmographic Imaging (PPGI) allows the determination of pulse rate variability from sequential beat-to-beat intervals (BBI) and pulse wave velocity from spatially resolved recorded pulse waves. In either case, sufficient temporal accuracy is essential.
The presented work investigates the temporal accuracy of BBI estimation from photoplethysmographic signals. Within comprehensive numeric…
▽ More
Photoplethysmographic Imaging (PPGI) allows the determination of pulse rate variability from sequential beat-to-beat intervals (BBI) and pulse wave velocity from spatially resolved recorded pulse waves. In either case, sufficient temporal accuracy is essential.
The presented work investigates the temporal accuracy of BBI estimation from photoplethysmographic signals. Within comprehensive numerical simulation, we systematically assess the impact of sampling rate, signal-to-noise ratio (SNR), and beat-to-beat shape variations on the root mean square error (RMSE) between real and estimated BBI.
Our results show that at sampling rates beyond 14 Hz only small errors exist when interpolation is used. For example, the average RMSE is 3 ms for a sampling rate of 14 Hz and an SNR of 18 dB. Further increasing the sampling rate only results in marginal improvements, e.g. more than tripling the sampling rate to 50 Hz reduces the error by approx. 14%. The most important finding relates to the SNR, which is shown to have a much stronger influence on the error than the sampling rate. For example, increasing the SNR from 18 dB to 24 dB at 14 Hz sampling rate reduced the error by almost 50% to 1.5 ms. Subtle beat-to-beat shape variations, moreover, increase the error decisively by up to 800%.
Our results are highly relevant in three regards: first, they partially explain different results in the literature on minimum sampling rates. Second, they emphasize the importance to consider SNR and possibly shape variation in investigations on the minimal sampling rate. Third, they underline the importance of appropriate processing techniques to increase SNR. Importantly, though our motivation is PPGI, the presented work immediately applies to contact PPG and PPG in other settings such as wearables. To enable further investigations, we make the scripts used in modelling and simulation freely available.
△ Less
Submitted 28 February, 2022;
originally announced February 2022.
-
Detection of Beat-to-Beat Intervals from Wrist Photoplethysmography in Patients with Sinus Rhythm and Atrial Fibrillation after Surgery
Authors:
Adrian Tarniceriu,
Jarkko Harju,
Antti Vehkaoja,
Jakub Parak,
Ricard Delgado-Gonzalo,
Philippe Renevey,
Arvi Yli-Hankala,
Ilkka Korhonen
Abstract:
Wrist photoplethysmography (PPG) allows unobtrusive monitoring of the heart rate (HR). PPG is affected by the capillary blood perfusion and the pum** function of the heart, which generally deteriorate with age and due to presence of cardiac arrhythmia. The performance of wrist PPG in monitoring beat-to-beat HR in older patients with arrhythmia has not been reported earlier. We monitored PPG from…
▽ More
Wrist photoplethysmography (PPG) allows unobtrusive monitoring of the heart rate (HR). PPG is affected by the capillary blood perfusion and the pum** function of the heart, which generally deteriorate with age and due to presence of cardiac arrhythmia. The performance of wrist PPG in monitoring beat-to-beat HR in older patients with arrhythmia has not been reported earlier. We monitored PPG from wrist in 18 patients recovering from surgery in the post anesthesia care unit, and evaluated the inter-beat interval (IBI) detection accuracy against ECG based R-to-R intervals (RRI). Nine subjects had sinus rhythm (SR, 68.0y$\pm$10.2y, 6 males) and nine subjects had atrial fibrillation (AF, 71.3y$\pm$7.8y, 4 males) during the recording. For the SR group, 99.44% of the beats were correctly identified, 2.39% extra beats were detected, and the mean absolute error (MAE) was 7.34 ms. For the AF group, 97.49% of the heartbeats were correctly identified, 2.26% extra beats were detected, and the MAE was 14.31 ms. IBI from the PPG were hence in close agreement with the ECG reference in both groups. The results suggest that wrist PPG provides a comfortable alternative to ECG and can be used for long-term monitoring and screening of AF episodes.
△ Less
Submitted 8 November, 2017;
originally announced November 2017.