Dielectric properties of Poly(vinylidene fluoride) / CaCu3Ti4O12 composites
Authors:
P. Thomasa,
K. T. Varughese,
K. Dwarakanath,
K. B. R. Varma
Abstract:
The possibility of obtaining relatively high dielectric constant polymer-ceramic composite by incorporating the giant dielectric constant material, CaCu3Ti4O12 (CCTO) in a Poly(vinylidene fluoride) (PVDF) polymer matrix by melt mixing and hot pressing process was demonstrated. The structure, morphology and dielectric properties of the composites were characterized using X ray diffraction, Thermal…
▽ More
The possibility of obtaining relatively high dielectric constant polymer-ceramic composite by incorporating the giant dielectric constant material, CaCu3Ti4O12 (CCTO) in a Poly(vinylidene fluoride) (PVDF) polymer matrix by melt mixing and hot pressing process was demonstrated. The structure, morphology and dielectric properties of the composites were characterized using X ray diffraction, Thermal analysis, Scanning Electron Microscope, and Impedance analyzer. The effective dielectric constant of the composite increased with increase in the volume fraction of CCTO at all the frequencies (100 Hz to 1MHz) under study. The dielectric loss did not show any variation upto 40 % loading of CCTO, but showed an increasing trend beyond 40%. The room temperature dielectric constant as high as 95 at 100Hz has been realized for the composite with 55 Vol % of CCTO, which has increased to about 190 at 150oC. Theoretical models like Maxwells Clausius Mossotti, Effective medium theory, logarithmic law and Yamada were employed to rationalize the dielectric behaviour of the composite and discussed. Keywords: A. Ceramic; A. Polymer matrix composite
△ Less
Submitted 17 January, 2013;
originally announced January 2013.
Astrophysical S_{17}(0) factor from a measurement of d(7Be,8B)n reaction at E_{c.m.} = 4.5 MeV
Authors:
J. J. Das,
V. M. Datar,
P. Sugathan,
N. Madhavan,
P. V. Madhusudhana Rao,
A. Jhingan,
A. Navin,
S. K. Dhiman,
S. Barua,
S. Nath,
T. Varughese,
A. K. Sinha,
R. Singh,
A. Ray,
D. L. Sastry,
R. G. Kulkarni,
R. Shyam
Abstract:
Angular distribution measurements of $^2$H($^7$Be,$^7$Be)$^2$H and $^2$H($^7$Be,$^8$B)$n$ reactions at $E_{c.m.}\sim$~4.5 MeV were performed to extract the astrophysical $S_{17}(0)$ factor using the asymptotic normalization coefficient (ANC) method. For this purpose a pure, low emittance $^7$Be beam was separated from the primary $^7$Li beam by a recoil mass spectrometer operated in a novel mode…
▽ More
Angular distribution measurements of $^2$H($^7$Be,$^7$Be)$^2$H and $^2$H($^7$Be,$^8$B)$n$ reactions at $E_{c.m.}\sim$~4.5 MeV were performed to extract the astrophysical $S_{17}(0)$ factor using the asymptotic normalization coefficient (ANC) method. For this purpose a pure, low emittance $^7$Be beam was separated from the primary $^7$Li beam by a recoil mass spectrometer operated in a novel mode. A beam stopper at 0$^{\circ}$ allowed the use of a higher $^7$Be beam intensity. Measurement of the elastic scattering in the entrance channel using kinematic coincidence, facilitated the determination of the optical model parameters needed for the analysis of the transfer data. The present measurement significantly reduces errors in the extracted $^7$Be(p,$γ$) cross section using the ANC method. We get $S_{17}$~(0)~=~20.7~$\pm$~2.4 eV~b.
△ Less
Submitted 23 February, 2006; v1 submitted 21 September, 2004;
originally announced September 2004.