Comparative Analysis of Information Theoretic and Statistical Methods for Line Parameter Estimation
Authors:
Anushka Sharma,
Antos Cheeramban Varghese,
Anamitra Pal
Abstract:
Recent studies indicate that the noise characteristics of phasor measurement units (PMUs) can be more accurately described by non-Gaussian distributions. Consequently, estimation techniques based on Gaussian noise assumptions may produce poor results with PMU data. This paper considers the PMU based line parameter estimation (LPE) problem, and investigates the performance of four state-of-the-art…
▽ More
Recent studies indicate that the noise characteristics of phasor measurement units (PMUs) can be more accurately described by non-Gaussian distributions. Consequently, estimation techniques based on Gaussian noise assumptions may produce poor results with PMU data. This paper considers the PMU based line parameter estimation (LPE) problem, and investigates the performance of four state-of-the-art techniques in solving this problem in presence of non-Gaussian measurement noise. The rigorous comparative analysis highlights the merits and demerits of each technique w.r.t. the LPE problem, and identifies conditions under which they are expected to give good results.
△ Less
Submitted 24 April, 2024;
originally announced April 2024.
-
Time-Synchronized Full System State Estimation Considering Practical Implementation Challenges
Authors:
Antos Cheeramban Varghese,
Hritik Shah,
Behrouz Azimian,
Anamitra Pal,
Evangelos Farantatos
Abstract:
As the phasor measurement unit (PMU) placement problem involves a cost-benefit trade-off, more PMUs get placed on the higher voltage buses. However, this causes many of the lower voltage levels of the bulk power system to not be observed by PMUs. This lack of visibility then makes time-synchronized state estimation of the full system a challenging problem. We propose a Deep Neural network-based St…
▽ More
As the phasor measurement unit (PMU) placement problem involves a cost-benefit trade-off, more PMUs get placed on the higher voltage buses. However, this causes many of the lower voltage levels of the bulk power system to not be observed by PMUs. This lack of visibility then makes time-synchronized state estimation of the full system a challenging problem. We propose a Deep Neural network-based State Estimator (DeNSE) to overcome this problem. The DeNSE employs a Bayesian framework to indirectly combine inferences drawn from slow timescale but widespread supervisory control and data acquisition (SCADA) data with fast timescale but select PMU data to attain sub-second situational awareness of the entire system. The practical utility of the proposed approach is demonstrated by considering topology changes, non-Gaussian measurement noise, and bad data detection and correction. The results obtained using the IEEE 118-bus system show the superiority of the DeNSE over a purely SCADA state estimator and a PMU-only linear state estimator from a techno-economic viability perspective. Lastly, scalability of the DeNSE is proven by estimating the states of a large and realistic 2000-bus Synthetic Texas system.
△ Less
Submitted 21 March, 2024; v1 submitted 3 December, 2022;
originally announced December 2022.
-
Transmission Line Parameter Estimation Under Non-Gaussian Measurement Noise
Authors:
Antos Cheeramban Varghese,
Anamitra Pal,
Gautam Dasarathy
Abstract:
Accurate knowledge of transmission line parameters is essential for a variety of power system monitoring, protection, and control applications. The use of phasor measurement unit (PMU) data for transmission line parameter estimation (TLPE) is well-documented. However, existing literature on PMU-based TLPE implicitly assumes the measurement noise to be Gaussian. Recently, it has been shown that the…
▽ More
Accurate knowledge of transmission line parameters is essential for a variety of power system monitoring, protection, and control applications. The use of phasor measurement unit (PMU) data for transmission line parameter estimation (TLPE) is well-documented. However, existing literature on PMU-based TLPE implicitly assumes the measurement noise to be Gaussian. Recently, it has been shown that the noise in PMU measurements (especially in the current phasors) is better represented by Gaussian mixture models (GMMs), i.e., the noises are non-Gaussian. We present a novel approach for TLPE that can handle non-Gaussian noise in the PMU measurements. The measurement noise is expressed as a GMM, whose components are identified using the expectation-maximization (EM) algorithm. Subsequently, noise and parameter estimation is carried out by solving a maximum likelihood estimation problem iteratively until convergence. The superior performance of the proposed approach over traditional approaches such as least squares and total least squares as well as the more recently proposed minimum total error entropy approach is demonstrated by performing simulations using the IEEE 118-bus system as well as proprietary PMU data obtained from a U.S. power utility.
△ Less
Submitted 27 August, 2022;
originally announced August 2022.
-
Statistical Characterization of Random Errors Present in Synchrophasor Measurements
Authors:
Demetra Salls,
Jairo RamÃrez Torres,
Antos Cheeramban Varghese,
John Patterson,
Anamitra Pal
Abstract:
The statistical characterization of the measurement errors of a phasor measurement unit (PMU) is currently receiving considerable interest in the power systems community. This paper focuses on the characteristics of the errors in magnitude and angle measurements introduced only by the PMU device (called random errors in this paper), during ambient conditions, using a high-precision calibrator. The…
▽ More
The statistical characterization of the measurement errors of a phasor measurement unit (PMU) is currently receiving considerable interest in the power systems community. This paper focuses on the characteristics of the errors in magnitude and angle measurements introduced only by the PMU device (called random errors in this paper), during ambient conditions, using a high-precision calibrator. The experimental results indicate that the random errors follow a non-Gaussian distribution. They also show that the M-class and P-class PMUs have distinct error characteristics. The results of this analysis will help researchers design algorithms that account for the non-Gaussian nature of the errors in synchrophasor measurements, thereby improving the practical utility of the said-algorithms in addition to building on precedence for using high-precision calibrators to perform accurate error tests.
△ Less
Submitted 16 March, 2021;
originally announced March 2021.