-
Towards Measuring the Ground State Hyperfine Splitting of Antihydrogen -- A Progress Report
Authors:
C. Sauerzopf,
A. Capon,
M. Diermaier,
P. Dupré,
Y. Higashi,
C. Kaga,
B. Kolbinger,
M. Leali,
S. Lehner,
E. Lodi Rizzini,
C. Malbrunot,
V. Mascagna,
O. Massiczek,
D. J. Murtagh,
Y. Nagata,
B. Radics,
M. C. Simon,
K. Suzuki,
M. Tajima,
S. Ulmer,
S. Vamosi,
S. van Gorp,
J. Zmeskal,
H. Breuker,
H. Higaki
, et al. (6 additional authors not shown)
Abstract:
We report the successful commissioning and testing of a dedicated field-ioniser chamber for measuring principal quantum number distributions in antihydrogen as part of the ASACUSA hyperfine spectroscopy apparatus. The new chamber is combined with a beam normalisation detector that consists of plastic scintillators and a retractable passivated implanted planar silicon (PIPS) detector.
We report the successful commissioning and testing of a dedicated field-ioniser chamber for measuring principal quantum number distributions in antihydrogen as part of the ASACUSA hyperfine spectroscopy apparatus. The new chamber is combined with a beam normalisation detector that consists of plastic scintillators and a retractable passivated implanted planar silicon (PIPS) detector.
△ Less
Submitted 6 June, 2016;
originally announced June 2016.
-
BASE - The Baryon Antibaryon Symmetry Experiment
Authors:
C. Smorra,
K. Blaum,
L. Bojtar,
M. Borchert,
K. A. Franke,
T. Higuchi,
N. Leefer,
H. Nagahama,
Y. Matsuda,
A. Mooser,
M. Niemann,
C. Ospelkaus,
W. Quint,
G. Schneider,
S. Sellner,
T. Tanaka,
S. Van Gorp,
J. Walz,
Y. Yamazaki,
S. Ulmer
Abstract:
The Baryon Antibaryon Symmetry Experiment (BASE) aims at performing a stringent test of the combined charge parity and time reversal (CPT) symmetry by comparing the magnetic moments of the proton and the antiproton with high precision. Using single particles in a Penning trap, the proton/antiproton $g$-factors, i.e. the magnetic moment in units of the nuclear magneton, are determined by measuring…
▽ More
The Baryon Antibaryon Symmetry Experiment (BASE) aims at performing a stringent test of the combined charge parity and time reversal (CPT) symmetry by comparing the magnetic moments of the proton and the antiproton with high precision. Using single particles in a Penning trap, the proton/antiproton $g$-factors, i.e. the magnetic moment in units of the nuclear magneton, are determined by measuring the respective ratio of the spin-precession frequency to the cyclotron frequency. The spin precession frequency is measured by non-destructive detection of spin quantum transitions using the continuous Stern-Gerlach effect, and the cyclotron frequency is determined from the particle's motional eigenfrequencies in the Penning trap using the invariance theorem. By application of the double Penning-trap method we expect that in our measurements a fractional precision of $δg/g$ 10$^{-9}$ can be achieved. The successful application of this method to the antiproton will represent a factor 1000 improvement in the fractional precision of its magnetic moment. The BASE collaboration has constructed and commissioned a new experiment at the Antiproton Decelerator (AD) of CERN. This article describes and summarizes the physical and technical aspects of this new experiment.
△ Less
Submitted 29 April, 2016;
originally announced April 2016.
-
A reservoir trap for antiprotons
Authors:
Christian Smorra,
Andreas Mooser,
Kurt Franke,
Hiroki Nagahama,
Georg Schneider,
Takashi Higuchi,
Simon Van Gorp,
Klaus Blaum,
Yasuyuki Matsuda,
Wolfgang Quint,
Jochen Walz,
Yasunori Yamazaki,
Stefan Ulmer
Abstract:
We have developed techniques to extract arbitrary fractions of antiprotons from an accumulated reservoir, and to inject them into a Penning-trap system for high-precision measurements. In our trap-system antiproton storage times > 1.08 years are estimated. The device is fail-safe against power-cuts of up to 10 hours. This makes our planned comparisons of the fundamental properties of protons and a…
▽ More
We have developed techniques to extract arbitrary fractions of antiprotons from an accumulated reservoir, and to inject them into a Penning-trap system for high-precision measurements. In our trap-system antiproton storage times > 1.08 years are estimated. The device is fail-safe against power-cuts of up to 10 hours. This makes our planned comparisons of the fundamental properties of protons and antiprotons independent from accelerator cycles, and will enable us to perform experiments during long accelerator shutdown periods when background magnetic noise is low. The demonstrated scheme has the potential to be applied in many other precision Penning trap experiments dealing with exotic particles.
△ Less
Submitted 15 July, 2015;
originally announced July 2015.
-
The magnetic moments of the proton and the antiproton
Authors:
S. Ulmer,
A. Mooser,
K. Blaum,
S. Braeuninger,
K. Franke,
H. Kracke,
C. Leiteritz,
Y. Matsuda,
H. Nagahama,
C. Ospelkaus,
C. C. Rodegheri,
W. Quint,
G. Schneider,
C. Smorra,
S. Van Gorp,
J. Walz,
Y. Yamazaki
Abstract:
Recent exciting progress in the preparation and manipulation of the motional quantum states of a single trapped proton enabled the first direct detection of the particle's spin state. Based on this success the proton magnetic moment $μ_p$ was measured with ppm precision in a Penning trap with a superimposed magnetic field inhomogeneity. An improvement by an additional factor of 1000 in precision i…
▽ More
Recent exciting progress in the preparation and manipulation of the motional quantum states of a single trapped proton enabled the first direct detection of the particle's spin state. Based on this success the proton magnetic moment $μ_p$ was measured with ppm precision in a Penning trap with a superimposed magnetic field inhomogeneity. An improvement by an additional factor of 1000 in precision is possible by application of the so-called double Penning trap technique. In a recent paper we reported the first demonstration of this method with a single trapped proton, which is a major step towards the first direct high-precision measurement of $μ_p$. The techniques required for the proton can be directly applied to measure the antiproton magnetic moment $μ_{\bar{p}}$. An improvement in precision of $μ_{\bar{p}}$ by more than three orders of magnitude becomes possible, which will provide one of the most sensitive tests of CPT invariance. To achieve this research goal we are currently setting up the Baryon Antibaryon Symmetry Experiment (BASE) at the antiproton decelerator (AD) of CERN.
△ Less
Submitted 7 February, 2014;
originally announced February 2014.
-
Towards a high-precision measurement of the antiproton magnetic moment
Authors:
C. Smorra,
K. Blaum,
K. Franke,
Y. Matsuda,
A. Mooser,
H. Nagahama,
C. Ospelkaus,
W. Quint,
G. Schneider,
S. Van Gorp,
J. Walz,
Y. Yamazaki,
S. Ulmer
Abstract:
The recent observation of single spins flips with a single proton in a Penning trap opens the way to measure the proton magnetic moment with high precision. Based on this success, which has been achieved with our apparatus at the University of Mainz, we demonstrated recently the first application of the so called double Penning-trap method with a single proton. This is a major step towards a measu…
▽ More
The recent observation of single spins flips with a single proton in a Penning trap opens the way to measure the proton magnetic moment with high precision. Based on this success, which has been achieved with our apparatus at the University of Mainz, we demonstrated recently the first application of the so called double Penning-trap method with a single proton. This is a major step towards a measurement of the proton magnetic moment with ppb precision. To apply this method to a single trapped antiproton our collaboration is currently setting up a companion experiment at the antiproton decelerator of CERN. This effort is recognized as the Baryon Antibaryon Symmetry Experiment (BASE). A comparison of both magnetic moment values will provide a stringent test of CPT invariance with baryons.
△ Less
Submitted 9 January, 2014;
originally announced January 2014.
-
Electron shakeoff following the ?+ decay of trapped 35Ar+ ions
Authors:
C. Couratin,
X. Fabian,
B. Fabre,
B. Pons,
X. Fléchard,
E. Liénard,
G. Ban,
M. Breitenfeldt,
P. Delahaye,
D. Durand,
A. Méry,
O. Naviliat-Cuncic,
T. Porobic,
G. Quéméner,
D. Rodriguez,
N. Severijns,
J. C. Thomas,
S. Van Gorp
Abstract:
The electron shakeoff of $^{35}$Cl atoms resulting from the $β$$^+$ decay of $^{35}$Ar$^+$ ions has been investigated using a Paul trap coupled to a recoil-ion spectrometer. The charge-state distribution of the recoiling daughter nuclei is compared to theoretical calculations accounting for shakeoff and Auger processes. The calculations are in excellent agreement with the experimental results and…
▽ More
The electron shakeoff of $^{35}$Cl atoms resulting from the $β$$^+$ decay of $^{35}$Ar$^+$ ions has been investigated using a Paul trap coupled to a recoil-ion spectrometer. The charge-state distribution of the recoiling daughter nuclei is compared to theoretical calculations accounting for shakeoff and Auger processes. The calculations are in excellent agreement with the experimental results and enable to identify the ionization reaction routes leading to the formation of all charge states.
△ Less
Submitted 28 October, 2013; v1 submitted 11 October, 2013;
originally announced October 2013.
-
Hyperfine Field and Hyperfine Anomalies of Copper Impurities in Iron
Authors:
V. V. Golovko,
F. Wauters,
S. Cottenier,
M. Breitenfeldt,
V. De Leebeeck,
S. Roccia,
G. Soti,
M. Tandecki,
E. Traykov,
S. Van Gorp,
D. Zákoucký,
N. Severijns
Abstract:
A new value for the hyperfine magnetic field of copper impurities in iron is obtained by combining resonance frequencies from experiments involving β-NMR on oriented nuclei on 59-Cu, 69-Cu, and 71-Cu with magnetic moment values from collinear laser spectroscopy measurements on these isotopes. The resulting value, i.e., Bhf(CuFe) = -21.794(10) T, is in agreement with the value adopted until now but…
▽ More
A new value for the hyperfine magnetic field of copper impurities in iron is obtained by combining resonance frequencies from experiments involving β-NMR on oriented nuclei on 59-Cu, 69-Cu, and 71-Cu with magnetic moment values from collinear laser spectroscopy measurements on these isotopes. The resulting value, i.e., Bhf(CuFe) = -21.794(10) T, is in agreement with the value adopted until now but is an order of magnitude more precise. It is consistent with predictions from ab initio calculations. Comparing the hyperfine field values obtained for the individual isotopes, the hyperfine anomalies in Fe were determined to be 59Δ69=0.15(9)% and 71Δ69=0.07(11)%.
△ Less
Submitted 29 July, 2011;
originally announced July 2011.
-
The half-life of $^{221}$Fr in Si and Au at 4K and at mK temperatures
Authors:
F. Wauters,
B. Verstichel,
M. Breitenfeldt,
V. De Leebeeck,
V. Yu. Kozlov,
I. Kraev,
S. Roccia,
G. Soti,
M. Tandecki,
E. Traykov,
S. Van Gorp,
D. Z'akouck'y,
N. Severijns
Abstract:
The half-life of the $α$ decaying nucleus $^{221}$Fr was determined in different environments, i.e. embedded in Si at 4 K, and embedded in Au at 4 K and about 20 mK. No differences in half-life for these different conditions were observed within 0.1%. Furthermore, we quote a new value for the absolute half-life of $^{221}$Fr of t$_{1/2}$ = 286.1(10) s, which is of comparable precision to the mos…
▽ More
The half-life of the $α$ decaying nucleus $^{221}$Fr was determined in different environments, i.e. embedded in Si at 4 K, and embedded in Au at 4 K and about 20 mK. No differences in half-life for these different conditions were observed within 0.1%. Furthermore, we quote a new value for the absolute half-life of $^{221}$Fr of t$_{1/2}$ = 286.1(10) s, which is of comparable precision to the most precise value available in literature.
△ Less
Submitted 29 October, 2010;
originally announced October 2010.
-
First detection and energy measurement of recoil ions following beta decay in a Penning trap with the WITCH experiment
Authors:
M. Beck,
S. Coeck,
V. Yu. Kozlov,
M. Breitenfeld,
P. Delahaye,
P. Friedag,
M. Herbane,
A. Herlert,
I. S. Kraev,
J. Mader,
M. Tandecki,
S. Van Gorp,
F. Wauters,
Ch. Weinheimer,
F. Wenander,
N. Severijns
Abstract:
The WITCH experiment (Weak Interaction Trap for CHarged particles) will search for exotic interactions by investigating the beta-neutrino angular correlation via the measurement of the recoil energy spectrum after beta decay. As a first step the recoil ions from the beta-minus decay of 124In stored in a Penning trap have been detected. The evidence for the detection of recoil ions is shown and the…
▽ More
The WITCH experiment (Weak Interaction Trap for CHarged particles) will search for exotic interactions by investigating the beta-neutrino angular correlation via the measurement of the recoil energy spectrum after beta decay. As a first step the recoil ions from the beta-minus decay of 124In stored in a Penning trap have been detected. The evidence for the detection of recoil ions is shown and the properties of the ion cloud that forms the radioactive source for the experiment in the Penning trap are presented.
△ Less
Submitted 1 August, 2010;
originally announced August 2010.
-
Precision measurements of the $^{60}$Co $β$-asymmetry parameter in search for tensor currents in weak interactions
Authors:
F. Wauters,
I. S. Kraev,
D. Zákoucký,
M. Beck,
M. Breitenfeldt,
V. De Leebeeck,
V. V. Golovko,
V. Yu. Kozlov,
T. Phalet,
S. Roccia,
G. Soti,
M. Tandecki,
I. S. Towner,
E. Traykov,
S. Van Gorp,
N. Severijns
Abstract:
The $β$-asymmetry parameter $\widetilde{A}$ for the Gamow-Teller decay of $^{60}$Co was measured by polarizing the radioactive nuclei with the brute force low-temperature nuclear-orientation method. The $^{60}$Co activity was cooled down to milliKelvin temperatures in a $^3$He-$^4$He dilution refrigerator in an external 13 T magnetic field. The $β$ particles were observed by a 500 $μm$ thick Si PI…
▽ More
The $β$-asymmetry parameter $\widetilde{A}$ for the Gamow-Teller decay of $^{60}$Co was measured by polarizing the radioactive nuclei with the brute force low-temperature nuclear-orientation method. The $^{60}$Co activity was cooled down to milliKelvin temperatures in a $^3$He-$^4$He dilution refrigerator in an external 13 T magnetic field. The $β$ particles were observed by a 500 $μm$ thick Si PIN diode operating at a temperature of about 10 K in a magnetic field of 0.6 T. Extensive GEANT4 Monte-Carlo simulations were performed to gain control over the systematic effects. Our result, $\widetilde{A} = -1.014(12)_{stat}(16)_{syst}$, is in agreement with the Standard-Model value of $-0.987(9)$, which includes recoil-order corrections that were addressed for the first time for this isotope. Further, it enables limits to be placed on possible tensor-type charged weak currents as well as other physics beyond the Standard Model.
△ Less
Submitted 27 May, 2010;
originally announced May 2010.
-
A GEANT4 Monte-Carlo Simulation Code for precision beta spectroscopy
Authors:
F. Wauters,
I. Kraev,
D. Zakoucky,
M. Beck,
V. V. Golovko,
V. Yu. Kozlov,
T. Phalet,
M. Tandecki,
E. Traykov,
S. Van Gorp,
N. Severijns
Abstract:
The measurement of the beta asymmetry parameter in nuclear beta decay is a potentially very sensitive tool to search for non V-A components in the charge-changing weak interaction. To reach the required precision (percent level) all effects that modify the emission pattern of the beta radiation, i.e. the geometry of the setup, the effect of the magnetic field on the trajectories of beta particle…
▽ More
The measurement of the beta asymmetry parameter in nuclear beta decay is a potentially very sensitive tool to search for non V-A components in the charge-changing weak interaction. To reach the required precision (percent level) all effects that modify the emission pattern of the beta radiation, i.e. the geometry of the setup, the effect of the magnetic field on the trajectories of beta particles as well as (back)scattering in the source, on the sample holder and on the detector, have to be correctly taken into account in the analysis of the data. A thorough study of these effects and a new method based on detailed GEANT4 Monte-Carlo simulations that was developed for this purpose is presented here. The code was developed for beta asymmetry measurements by means of the Low Temperature Nuclear Orientation (LTNO) method, but can in principle be generalized to other experimental setups using other polarization techniques.
△ Less
Submitted 27 July, 2009;
originally announced July 2009.
-
Performance of silicon PIN photodiodes at low temperatures and in high magnetic fields
Authors:
F. Wauters,
I. S. Kraev,
M. Tandecki,
E. Traykov,
S. Van Gorp,
D. Zakoucky,
N. Severijns
Abstract:
The performance of a Si PIN diode (type Hamamatsu S3590-06) as an energy sen- sitive detector operating at cryogenic temperatures (~10 K) and in magnetic fields up to 11 T was investigated, using a 207Bi conversion electron source. It was found that the detector still performs well under these conditions, with small changes in the response function being observed in high magnetic fields, e.g. a…
▽ More
The performance of a Si PIN diode (type Hamamatsu S3590-06) as an energy sen- sitive detector operating at cryogenic temperatures (~10 K) and in magnetic fields up to 11 T was investigated, using a 207Bi conversion electron source. It was found that the detector still performs well under these conditions, with small changes in the response function being observed in high magnetic fields, e.g. a 30% to 50% decrease in energy resolution. A GEANT4 Monte Carlo simulation showed that the observed effects are mainly due to the modified trajectories of the electrons due to the influence of the magnetic field, which changes the scattering conditions, rather than to intrinsic changes of the performance of the detector itself.
△ Less
Submitted 31 December, 2008;
originally announced January 2009.
-
Beta asymmetry parameter in the decay of 114In
Authors:
F. Wauters,
V. De Leebeeck,
I. Kraev,
M. Tandecki,
E. Traykov,
S. Van Gorp,
N. Severijns,
D. Zakoucky
Abstract:
The beta asymmetry parameter A for the pure Gamow-Teller decay of 114In is reported. The low temperature nuclear orientation method was combined with a GEANT4 based simulation code allowing for the first time to address in detail the effects of scattering and of the magnetic field. The result, A = -0.994 +/- 0.010stat +/- 0.010syst, constitutes the most accurate value for the asymmetry parameter…
▽ More
The beta asymmetry parameter A for the pure Gamow-Teller decay of 114In is reported. The low temperature nuclear orientation method was combined with a GEANT4 based simulation code allowing for the first time to address in detail the effects of scattering and of the magnetic field. The result, A = -0.994 +/- 0.010stat +/- 0.010syst, constitutes the most accurate value for the asymmetry parameter of a nuclear beta transition to date. The value is in agreement with the Standard Model prediction of A = -1 and provides new limits on tensor type charged weak currents.
△ Less
Submitted 28 July, 2009; v1 submitted 31 December, 2008;
originally announced January 2009.
-
The WITCH experiment: Acquiring the first recoil ion spectrum
Authors:
V. Yu. Kozlov,
M. Beck,
S. Coeck,
P. Delahaye,
P. Friedag,
M. Herbane,
A. Herlert,
I. S. Kraev,
M. Tandecki,
S. Van Gorp,
F. Wauters,
Ch. Weinheimer,
F. Wenander,
D. Zakoucky,
N. Severijns
Abstract:
The standard model of the electroweak interaction describes beta-decay in the well-known V-A form. Nevertheless, the most general Hamiltonian of a beta-decay includes also other possible interaction types, e.g. scalar (S) and tensor (T) contributions, which are not fully ruled out yet experimentally. The WITCH experiment aims to study a possible admixture of these exotic interaction types in nuc…
▽ More
The standard model of the electroweak interaction describes beta-decay in the well-known V-A form. Nevertheless, the most general Hamiltonian of a beta-decay includes also other possible interaction types, e.g. scalar (S) and tensor (T) contributions, which are not fully ruled out yet experimentally. The WITCH experiment aims to study a possible admixture of these exotic interaction types in nuclear beta-decay by a precise measurement of the shape of the recoil ion energy spectrum. The experimental set-up couples a double Penning trap system and a retardation spectrometer. The set-up is installed in ISOLDE/CERN and was recently shown to be fully operational. The current status of the experiment is presented together with the data acquired during the 2006 campaign, showing the first recoil ion energy spectrum obtained. The data taking procedure and corresponding data acquisition system are described in more detail. Several further technical improvements are briefly reviewed.
△ Less
Submitted 22 July, 2008;
originally announced July 2008.