Skip to main content

Showing 1–17 of 17 results for author: Van Esch, P

.
  1. arXiv:1703.03626  [pdf, other

    physics.ins-det nucl-ex

    Multi-Grid Detector for Neutron Spectroscopy: Results Obtained on Time-of-Flight Spectrometer CNCS

    Authors: M. Anastasopoulos, R. Bebb, K. Berry, J. Birch, T. Bryś, J. -C. Buffet, J. -F. Clergeau, P. P. Deen, G. Ehlers, P. van Esch, S. M. Everett, B. Guerard, R. Hall-Wilton, K. Herwig, L. Hultman, C. Höglund, I. Iruretagoiena, F. Issa, J. Jensen, A. Khaplanov, O. Kirstein, I. Lopez-Higuera, F. Piscitelli, L. Robinson, S. Schmidt , et al. (1 additional authors not shown)

    Abstract: The Multi-Grid detector technology has evolved from the proof-of-principle and characterisation stages. Here we report on the performance of the Multi-Grid detector, the MG.CNCS prototype, which has been installed and tested at the Cold Neutron Chopper Spectrometer, CNCS at SNS. This has allowed a side-by-side comparison to the performance of $^3$He detectors on an operational instrument. The demo… ▽ More

    Submitted 3 April, 2017; v1 submitted 10 March, 2017; originally announced March 2017.

    Comments: submitted to JINST

  2. arXiv:1510.01085  [pdf, ps, other

    cond-mat.mtrl-sci physics.ins-det

    Neutron reflectometry on highly absorbing films and its application to 10B4C-based neutron detectors

    Authors: F. Piscitelli, A. Khaplanov, A. Devishvili, S. Schmidt, C. Höglund, J. Birch, A. J. C. Dennison, P. Gutfreund, R. Hall-Wilton, P. Van Esch

    Abstract: Neutron reflectometry is a powerful tool used for studies of surfaces and interfaces. In general the absorption in the typical studied materials can be neglected and this technique is limited to the measurement of the reflectivity only. In the case of strongly absorbing nuclei the number of neutrons is not conserved and the absorption can be directly measured by using the neutron-induced fluoresce… ▽ More

    Submitted 5 October, 2015; originally announced October 2015.

    Comments: 13 pages, 6 figures

    Journal ref: Proc. R. Soc. A 472: 20150711 (2016)

  3. Investigation of background in large-area neutron detectors due to alpha emission from impurities in aluminium

    Authors: J. Birch, J. -C. Buffet, J. -F. Clergeau, P. van Esch, M. Ferraton, B. Guerard, R. Hall-Wilton, L. Hultman, C. Höglund, J. Jensen, A. Khaplanov, F. Piscitelli

    Abstract: Thermal neutron detector based on films of $^{10}$B$_4$C have been developed as an alternative to $^3$He detectors. In particular, The Multi-Grid detector concept is considered for future large area detectors for ESS and ILL instruments. An excellent signal-to-background ratio is essential to attain expected scientific results. Aluminium is the most natural material for the mechanical structure of… ▽ More

    Submitted 16 September, 2015; v1 submitted 2 July, 2015; originally announced July 2015.

    Comments: 14 pages, 8 figures. Submission to Journal of Instrumentation new version uploaded addressing referee comments (minor revision). Added discussion of radon contamination and more details on simulated spectra

  4. Study of a high spatial resolution 10B-based thermal neutron detector for application in neutron reflectometry: the Multi-Blade prototype

    Authors: F. Piscitelli, J. C. Buffet, J. F. Clergeau, S. Cuccaro, B. Guerard, A. Khaplanov, Q. La Manna, J. M. Rigal, P. Van Esch

    Abstract: Although for large area detectors it is crucial to find an alternative to detect thermal neutrons because of the 3He shortage, this is not the case for small area detectors. Neutron scattering science is still growing its instruments' power and the neutron flux a detector must tolerate is increasing. For small area detectors the main effort is to expand the detectors' performances. At Institut Lau… ▽ More

    Submitted 9 December, 2013; originally announced December 2013.

    Journal ref: 2014 JINST 9 P03007

  5. arXiv:1307.7507  [pdf, other

    physics.ins-det

    An Information-Theoretical Approach to Image Resolution Applied to Neutron Imaging Detectors based upon Individual Discriminator Signals

    Authors: Jean-François Clergeau, Matthieu Ferraton, Bruno Guérard, Anton Khaplanov, Francesco Piscitelli, Martin Platz, Jean-Marie Rigal, Patrick Van Esch, Thibault Daullé

    Abstract: 1D or 2D neutron imaging detectors with individual wire or strip readout using discriminators have the advantage of being able to treat several neutron impacts partially overlap** in time, hence reducing global dead time. A single neutron impact usually gives rise to several discriminator signals. In this paper, we introduce an information-theoretical definition of image resolution. Two point-li… ▽ More

    Submitted 29 July, 2013; originally announced July 2013.

    Comments: Article with poster number 1333 presented at the ANIMMA 2013 conference in Marseille. Corresponding author [email protected]

  6. Investigation of gamma-ray sensitivity of neutron detectors based on thin converter films

    Authors: Anton Khaplanov, Francesco Piscitelli, Jean-Claude Buffet, Jean-Francois Clergeau, Jonathan Correa, Patrick van Esch, Mathieu Ferraton, Bruno Guerard, Richard Hall-Wilton

    Abstract: Currently, many detector technologies for thermal neutron detection are in development in order to lower the demand for the rare 3He gas. Gas detectors with solid thin film neutron converters readout by gas proportional counter method have been proposed as an appropriate choice for applications where large area coverage is necessary. In this paper, we investigate the probability for gamma-rays to… ▽ More

    Submitted 26 June, 2013; originally announced June 2013.

    Comments: Submitted to Journal of Instrumentation

  7. arXiv:1302.3153  [pdf, ps, other

    physics.ins-det nucl-ex

    Analytical modeling of thin film neutron converters and its application to thermal neutron gas detectors

    Authors: Francesco Piscitelli, Patrick Van Esch

    Abstract: A simple model is explored mainly analytically to calculate and understand the PHS of single and multi-layer thermal neutron detectors and to help optimize the design in different circumstances. Several theorems are deduced that can help guide the design.

    Submitted 13 February, 2013; originally announced February 2013.

    Journal ref: 2013 JINST 8 P04020

  8. arXiv:1209.0566  [pdf, other

    physics.ins-det nucl-ex

    Multi-Grid Boron-10 detector for large area applications in neutron scattering science

    Authors: Ken Andersen, Thierry Bigault, Jens Birch, Jean-Claude Buffet, Jonathan Correa, Patrick van Esch, Bruno Guerard, Richard Hall-Wilton, Lars Hultman, Carina Höglund, Jens Jensen, Anton Khaplanov, Oliver Kirstein, Francesco Piscitelli, Christian Vettier

    Abstract: The present supply of 3He can no longer meet the detector demands of the upcoming ESS facility and continued detector upgrades at current neutron sources. Therefore viable alternative technologies are required to support the development of cutting-edge instrumentation for neutron scattering science. In this context, 10B-based detectors are being developed by collaboration between the ESS, ILL, and… ▽ More

    Submitted 4 September, 2012; originally announced September 2012.

    Comments: Presented at the ICANS-XX conference, March 2012

  9. Multiple hits in wire chambers and other particle detectors

    Authors: Patrick Van Esch

    Abstract: We propose an analysis of the dead time losses in counting imaging detectors such as MWPC which can resolve $k$ simultaneous hits, and analyze in more detail an $X-Y$ detector which has a third wire set which allows for the recognition of simultaneous impacts.

    Submitted 8 June, 2007; originally announced June 2007.

    Comments: 15 pages, 4 figures

    Journal ref: JINST2:P09004,2007

  10. arXiv:physics/0611034  [pdf, ps, other

    physics.ins-det

    Effects of ion drift on time-over-threshold charge estimates using first-order integrators in thermal neutron MWPC

    Authors: Patrick Van Esch, Thomas Durand

    Abstract: Time-over-threshold measurements of the output of a first order integration amplifier can be used as a cheap way to estimate the charge deposited on a wire in an MWPC. Even if the time scale of the first order system is seemingly much larger than the signal development time, we noticed experimentally a significant deviation from the relationship of time-over-threshold and the charge, as would be… ▽ More

    Submitted 3 November, 2006; originally announced November 2006.

    Comments: 8 pages, 5 figures

  11. An Electrostatic Lens to Reduce Parallax in Banana Gas Detectors

    Authors: Patrick Van Esch, Jean-Francois Clergeau, Kadda Medjoubi

    Abstract: Cylindrical "banana" gas detectors are often used in fixed-target experiments, because they are free of parallax effects in the equatorial plane. However, there is a growing demand to increase the height of these detectors in order to be more efficient or to cover more solid angle, and hence a parallax effect starts to limit the resolution in that direction. In this paper we propose a hardware c… ▽ More

    Submitted 4 August, 2006; originally announced August 2006.

    Journal ref: Nucl.Instrum.Meth.A540:361-367,2005

  12. arXiv:physics/0608048  [pdf, ps, other

    physics.ins-det

    An Optimal Lookup Table Construction for Charge Division with respect to Efficiency Flatness

    Authors: Patrick Van Esch, Frederic Millier

    Abstract: Static lookup tables as often used in the position calculation electronics in position sensitive detectors suffer from the well known problem that the propagation of digitization errors in the division leads to unequal efficiencies for the different output channels. In this paper we present a solution to the construction of such a lookup table which is optimal in the sense that the least possibl… ▽ More

    Submitted 4 August, 2006; originally announced August 2006.

    Journal ref: Rev.Sci.Instrum.74:5058,2003

  13. Off line Parallax Correction for Neutral Particle Gas Detectors

    Authors: Patrick Van Esch

    Abstract: In a neutral particle gas detector, the parallax error resulting from the perpendicular projection on the detection plane or wire of the radial particle trajectories emanating from a point like source (such as a scattering sample) can significantly spoil the apparent angular resolution of the detector. However, as we will show, the information is not lost. We propose an off line data treatment t… ▽ More

    Submitted 4 August, 2006; originally announced August 2006.

    Journal ref: Nucl.Instrum.Meth.A530:440-445,2004

  14. Design guide for electronics for resistive charge division in thermal neutron detection

    Authors: Patrick Van Esch, Thomas Gahl, Bruno Guerard

    Abstract: An amplifier has been designed for optimal use of position sensitive thermal neutron detectors using the principle of resistive charge division. The important points in this optimization are: high counting rates and good spatial resolution. This amplifier is built as a hybrid circuit and is now used on several new instruments at the ILL. It consists of a fast low noise current pre-amplifier, a g… ▽ More

    Submitted 4 August, 2006; originally announced August 2006.

    Comments: This is a longer version of a shorter publication, under the title: "Design criteria for electronics for charge division in thermal neutron detection"

    Journal ref: Nucl.Instrum.Meth.A526:493-500,2004

  15. Capacity formulas in MWPC: some critical reflexions

    Authors: Patrick Van Esch

    Abstract: An approximate analytical expression for "capacitance" of MWPC configurations circulates in the literature since decades and is copied over and over again. In this paper we will try to show that this formula corresponds to a physical quantity that is different from what it is usually thought to stand for.

    Submitted 2 August, 2006; originally announced August 2006.

  16. arXiv:quant-ph/0505059  [pdf, ps, other

    quant-ph

    On the Everett programme and the Born rule

    Authors: Patrick Van Esch

    Abstract: Proponents of the Everett interpretation of Quantum Theory have made efforts to show that to an observer in a branch, everything happens as if the projection postulate were true without postulating it. In this paper, we will indicate that it is only possible to deduce this rule if one introduces another postulate that is logically equivalent to introducing the projection postulate as an extra as… ▽ More

    Submitted 9 May, 2005; originally announced May 2005.

    Comments: 7 pages, no figures

  17. The H1 Forward Proton Spectrometer at HERA

    Authors: P. van Esch, M. Kapichine, A. Morozov, V. Spaskov, W. Bartel, B. List, H. Mahlke-Krueger, V. Schroeder, T. Wilksen, F. W. Buesser, K. Geske, O. Karschnik, F. Niebergall, H. Riege, J. Schuett, R. van Staa, C. Wittek, D. Dau, D. Newton, S. K. Kotelnikov, A. Lebedev, S. Rusakov, A. Astvatsatourov, J. Baehr, U. Harder , et al. (4 additional authors not shown)

    Abstract: The forward proton spectrometer is part of the H1 detector at the HERA collider. Protons with energies above 500 GeV and polar angles below 1 mrad can be detected by this spectrometer. The main detector components are scintillating fiber detectors read out by position-sensitive photo-multipliers. These detectors are housed in so-called Roman Pots which allow them to be moved close to the circula… ▽ More

    Submitted 20 January, 2000; originally announced January 2000.

    Comments: 20 pages, 10 figures, submitted to Nucl.Instr.and Methods

    Report number: DESY 99-158

    Journal ref: Nucl.Instrum.Meth.A446:409-425,2000