-
Testbeam Results of the Picosecond Avalanche Detector Proof-Of-Concept Prototype
Authors:
G. Iacobucci,
S. Zambito,
M. Milanesio,
T. Moretti,
J. Saidi,
L. Paolozzi,
M. Munker,
R. Cardella,
F. Martinelli,
A. Picardi,
H. Rücker,
A. Trusch,
P. Valerio,
F. Cadoux,
R. Cardarelli,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
Y. Gurimskaya,
R. Kotitsa,
C. Magliocca,
M. Nessi,
A. Pizarro-Medina
, et al. (2 additional authors not shown)
Abstract:
The proof-of-concept prototype of the Picosecond Avalanche Detector, a multi-PN junction monolithic silicon detector with continuous gain layer deep in the sensor depleted region, was tested with a beam of 180 GeV pions at the CERN SPS. The prototype features low noise and fast SiGe BiCMOS frontend electronics and hexagonal pixels with 100 μm pitch. At a sensor bias voltage of 125 V, the detector…
▽ More
The proof-of-concept prototype of the Picosecond Avalanche Detector, a multi-PN junction monolithic silicon detector with continuous gain layer deep in the sensor depleted region, was tested with a beam of 180 GeV pions at the CERN SPS. The prototype features low noise and fast SiGe BiCMOS frontend electronics and hexagonal pixels with 100 μm pitch. At a sensor bias voltage of 125 V, the detector provides full efficiency and average time resolution of 30, 25 and 17 ps in the overall pixel area for a power consumption of 0.4, 0.9 and 2.7 W/cm^2, respectively. In this first prototype the time resolution depends significantly on the distance from the center of the pixel, varying at the highest power consumption measured between 13 ps at the center of the pixel and 25 ps in the inter-pixel region.
△ Less
Submitted 23 August, 2022;
originally announced August 2022.
-
Picosecond Avalanche Detector -- working principle and gain measurement with a proof-of-concept prototype
Authors:
L. Paolozzi,
M. Munker,
R. Cardella,
M. Milanesio,
Y. Gurimskaya,
F. Martinelli,
A. Picardi,
H. Rücker,
A. Trusch,
P. Valerio,
F. Cadoux,
R. Cardarelli,
S. Débieux,
Y. Favre,
C. A. Fenoglio,
D. Ferrere,
S. Gonzalez-Sevilla,
R. Kotitsa,
C. Magliocca,
T. Moretti,
M. Nessi,
A. Pizarro Medina,
J. Sabater Iglesias,
J. Saidi,
M. Vicente Barreto Pinto
, et al. (2 additional authors not shown)
Abstract:
The Picosecond Avalanche Detector is a multi-junction silicon pixel detector based on a $\mathrm{(NP)_{drift}(NP)_{gain}}$ structure, devised to enable charged-particle tracking with high spatial resolution and picosecond time-stamp capability. It uses a continuous junction deep inside the sensor volume to amplify the primary charge produced by ionizing radiation in a thin absorption layer. The si…
▽ More
The Picosecond Avalanche Detector is a multi-junction silicon pixel detector based on a $\mathrm{(NP)_{drift}(NP)_{gain}}$ structure, devised to enable charged-particle tracking with high spatial resolution and picosecond time-stamp capability. It uses a continuous junction deep inside the sensor volume to amplify the primary charge produced by ionizing radiation in a thin absorption layer. The signal is then induced by the secondary charges moving inside a thicker drift region. A proof-of-concept monolithic prototype, consisting of a matrix of hexagonal pixels with 100 $μ$m pitch, has been produced using the 130 nm SiGe BiCMOS process by IHP microelectronics. Measurements on probe station and with a $^{55}$Fe X-ray source show that the prototype is functional and displays avalanche gain up to a maximum electron gain of 23. A study of the avalanche characteristics, corroborated by TCAD simulations, indicates that space-charge effects due to the large primary charge produced by the conversion of X-rays from the $^{55}$Fe source limits the effective gain.
△ Less
Submitted 25 September, 2022; v1 submitted 16 June, 2022;
originally announced June 2022.
-
Efficiency and time resolution of monolithic silicon pixel detectors in SiGe BiCMOS technology
Authors:
G. Iacobucci,
L. Paolozzi,
P. Valerio,
T. Moretti,
F. Cadoux,
R. Cardarelli,
R. Cardella,
S. Débieux,
Y. Favre,
D. Ferrere,
S. Gonzalez-Sevilla,
Y. Gurimskaya,
R. Kotitsa,
C. Magliocca,
F. Martinelli,
M. Milanesio,
M. Münker,
M. Nessi,
A. Picardi,
J. Saidi,
H. Rücker,
M. Vicente Barreto Pinto,
S. Zambito
Abstract:
A monolithic silicon pixel detector prototype has been produced in the SiGe BiCMOS SG13G2 130 nm node technology by IHP. The ASIC contains a matrix of hexagonal pixels with pitch of approximately 100 $μ$m. Three analog pixels were calibrated in laboratory with radioactive sources and tested in a 180 GeV/c pion beamline at the CERN SPS. A detection efficiency of $\left(99.9^{+0.1}_{-0.2}\right)$% w…
▽ More
A monolithic silicon pixel detector prototype has been produced in the SiGe BiCMOS SG13G2 130 nm node technology by IHP. The ASIC contains a matrix of hexagonal pixels with pitch of approximately 100 $μ$m. Three analog pixels were calibrated in laboratory with radioactive sources and tested in a 180 GeV/c pion beamline at the CERN SPS. A detection efficiency of $\left(99.9^{+0.1}_{-0.2}\right)$% was measured together with a time resolution of $(36.4 \pm 0.8)$ps at the highest preamplifier bias current working point of 150 $μ$A and at a sensor bias voltage of 160 V. The ASIC was also characterized at lower bias voltage and preamplifier current.
△ Less
Submitted 21 January, 2022; v1 submitted 16 December, 2021;
originally announced December 2021.
-
Measurements and analysis of different front-end configurations for monolithic SiGe BiCMOS pixel detectors for HEP applications
Authors:
Fulvio Martinelli,
Chiara Magliocca,
Roberto Cardella,
Edoardo Charbon,
Giuseppe Iacobucci,
Marzio Nessi,
Lorenzo Paolozzi,
Holger Rücker,
Pierpaolo Valerio
Abstract:
This paper presents a small-area monolithic pixel detector ASIC designed in 130 nm SiGe BiCMOS technology for the upgrade of the pre-shower detector of the FASER experiment at CERN. The purpose of this prototype is to study the integration of fast front-end electronics inside the sensitive area of the pixels and to identify the configuration that could satisfy at best the specifications of the exp…
▽ More
This paper presents a small-area monolithic pixel detector ASIC designed in 130 nm SiGe BiCMOS technology for the upgrade of the pre-shower detector of the FASER experiment at CERN. The purpose of this prototype is to study the integration of fast front-end electronics inside the sensitive area of the pixels and to identify the configuration that could satisfy at best the specifications of the experiment. Self-induced noise, instabilities and cross-talk were minimised to cope with the several challenges associated to the integration of pre-amplifiers and discriminators inside the pixels. The methodology used in the characterisation and the design choices will also be described. Two of the variants studied here will be implemented in the pre-production ASIC of the FASER experiment pre-shower for further tests.
△ Less
Submitted 22 November, 2021;
originally announced November 2021.
-
A massively scalable Time-to-Digital Converter with a PLL-free calibration system in a commercial 130 nm process
Authors:
Fulvio Martinelli,
Pierpaolo Valerio,
Roberto Cardarelli,
Edoardo Charbon,
Giuseppe Iacobucci,
Marzio Nessi,
Lorenzo Paolozzi
Abstract:
A 33.6 ps LSB Time-to-Digital converter was designed in 130 nm BiCMOS technology. The core of the converter is a differential 9-stage ring oscillator, based on a multi-path architecture. A novel version of this design is proposed, along with an analytical model of linearity. The model allowed us to understand the source of the performance superiority (in terms of linearity) of our design and to pr…
▽ More
A 33.6 ps LSB Time-to-Digital converter was designed in 130 nm BiCMOS technology. The core of the converter is a differential 9-stage ring oscillator, based on a multi-path architecture. A novel version of this design is proposed, along with an analytical model of linearity. The model allowed us to understand the source of the performance superiority (in terms of linearity) of our design and to predict further improvements. The oscillator is integrated in a event-by-event self-calibration system that allows avoiding any PLL-based synchronization. For this reason and for the compactness and simplicity of the architecture, the proposed TDC is suitable for applications in which a large number of converters and a massive parallelization are required such as High-Energy Physics and medical imaging detector systems. A test chip for the TDC has been fabricated and tested. The TDC shows a DNL$\leq$1.3 LSB, an INL$\leq$2 LSB and a single-shot precision of 19.5 ps (0.58 LSB). The chip dissipates a power of 5.4 mW overall.
△ Less
Submitted 1 September, 2021; v1 submitted 21 July, 2021;
originally announced July 2021.
-
Time resolution and power consumption of a monolithic silicon pixel prototype in SiGe BiCMOS technology
Authors:
L. Paolozzi,
R. Cardarelli,
S. Débieux,
Y. Favre,
D. Ferrère,
S. Gonzalez-Sevilla,
G. Iacobucci,
M. Kaynak,
F. Martinelli,
M. Nessi,
H. Rücker,
I. Sanna,
DMS Sultan,
P. Valerio,
E. Zaffaroni
Abstract:
SiGe BiCMOS technology can be used to produce ultra-fast, low-power silicon pixel sensors that provide state-of-the-art time resolution even without an internal gain mechanism. The development of such sensors requires the identification of the main factors that may degrade the timing performance and the characterisation of the dependance of the sensor time resolution on the amplifier power consump…
▽ More
SiGe BiCMOS technology can be used to produce ultra-fast, low-power silicon pixel sensors that provide state-of-the-art time resolution even without an internal gain mechanism. The development of such sensors requires the identification of the main factors that may degrade the timing performance and the characterisation of the dependance of the sensor time resolution on the amplifier power consumption. Measurements with a $ \mathrm{^{90}Sr} $ source of a prototype sensor produced in SG13G2 technology from IHP Microelectronics, shows a time resolution of 140 ps at an amplifier current of 7 $ \mathrmμ $A and 45 ps at higher power consumption. A full simulation shows that the resolution on the measurement of the signal time-over-threshold, used to correct for time walk, is the main factor affecting the timing performance.
△ Less
Submitted 28 August, 2020; v1 submitted 28 May, 2020;
originally announced May 2020.
-
A 50 ps resolution monolithic active pixel sensor without internal gain in SiGe BiCMOS technology
Authors:
G. Iacobucci,
R. Cardarelli,
S. Débieux,
F. A. Di Bello,
Y. Favre,
D. Hayakawa,
M. Kaynak,
M. Nessi,
L. Paolozzi,
H. Rücker,
DMS Sultan,
P. Valerio
Abstract:
A monolithic pixelated silicon detector designed for high time resolution has been produced in the SG13G2 130 nm SiGe BiCMOS technology of IHP Mikroelektronik. This proof-of-concept chip contains hexagonal pixels of 65 μm and 130 μm side. The SiGe front-end electronics implemented provides an equivalent noise charge of 90 and 160 electrons for a pixel capacitance of 70 and 220 fF, respectively, an…
▽ More
A monolithic pixelated silicon detector designed for high time resolution has been produced in the SG13G2 130 nm SiGe BiCMOS technology of IHP Mikroelektronik. This proof-of-concept chip contains hexagonal pixels of 65 μm and 130 μm side. The SiGe front-end electronics implemented provides an equivalent noise charge of 90 and 160 electrons for a pixel capacitance of 70 and 220 fF, respectively, and a total time walk of less than 1 ns. Lab measurements with a 90Sr source show a time resolution of the order of 50 ps. This result is competitive with silicon technologies that integrate an avalanche gain mechanism.
△ Less
Submitted 26 August, 2019;
originally announced August 2019.
-
Detector Technologies for CLIC
Authors:
A. C. Abusleme Hoffman,
G. Parès,
T. Fritzsch,
M. Rothermund,
H. Jansen,
K. Krüger,
F. Sefkow,
A. Velyka,
J. Schwandt,
I. Perić,
L. Emberger,
C. Graf,
A. Macchiolo,
F. Simon,
M. Szalay,
N. van der Kolk,
H. Abramowicz,
Y. Benhammou,
O. Borysov,
M. Borysova,
A. Joffe,
S. Kananov,
A. Levy,
I. Levy,
G. Eigen
, et al. (107 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Stan…
▽ More
The Compact Linear Collider (CLIC) is a high-energy high-luminosity linear electron-positron collider under development. It is foreseen to be built and operated in three stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. It offers a rich physics program including direct searches as well as the probing of new physics through a broad set of precision measurements of Standard Model processes, particularly in the Higgs-boson and top-quark sectors. The precision required for such measurements and the specific conditions imposed by the beam dimensions and time structure put strict requirements on the detector design and technology. This includes low-mass vertexing and tracking systems with small cells, highly granular imaging calorimeters, as well as a precise hit-time resolution and power-pulsed operation for all subsystems. A conceptual design for the CLIC detector system was published in 2012. Since then, ambitious R&D programmes for silicon vertex and tracking detectors, as well as for calorimeters have been pursued within the CLICdp, CALICE and FCAL collaborations, addressing the challenging detector requirements with innovative technologies. This report introduces the experimental environment and detector requirements at CLIC and reviews the current status and future plans for detector technology R&D.
△ Less
Submitted 7 May, 2019;
originally announced May 2019.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
The TT-PET Data Acquisition and Trigger System
Authors:
Y. Bandi,
Y. Favre,
D. Ferrere,
D. Forshaw,
R. Hanni,
D. Hayakawa,
G. Iacobucci,
P. Lutz,
A. Miucci,
L. Paolozzi,
E. Ripiccini,
C. Tognina,
P. Valerio,
M. Weber
Abstract:
This paper describes the data acquisition and trigger system of the Thin Time-of-flight PET (TT-PET) scanner. The system is designed to read out in the order of 1000 pixel sensors used in the scanner and to provide a reference timing signal to each sensor in order to measure time differences of better than 30 ps. This clock distribution is measured to have a jitter of less than 4 ps at the sensors…
▽ More
This paper describes the data acquisition and trigger system of the Thin Time-of-flight PET (TT-PET) scanner. The system is designed to read out in the order of 1000 pixel sensors used in the scanner and to provide a reference timing signal to each sensor in order to measure time differences of better than 30 ps. This clock distribution is measured to have a jitter of less than 4 ps at the sensors. Collected data is locally processed before being forwarded to storage. Data flow as well as control, configuration and monitoring aspects are are also addressed.
△ Less
Submitted 10 December, 2018;
originally announced December 2018.
-
Module concept and thermo-mechanical studies of the silicon-based TT-PET small-animal scanner
Authors:
Didier Ferrere,
Yves Bandi,
Frank Cadoux,
Dean Forshaw,
Daiki Hayakawa,
Giuseppe Iacobucci,
Sebastien Michal,
Antonio Miucci,
Marzio Nessi,
Lorenzo Paolozzi,
Emanuele Ripiccini,
Pierpaolo Valerio,
Michele Weber
Abstract:
The TT-PET collaboration is develo** an MRI-compatible small animal PET scanner in which the sensitive element is a monolithic silicon pixel ASIC targeting 30 ps RMS time resolution. The photon-detection technique is based on a stack of alternating layers of high-Z photon converter and 100 $\mathrm{μm}$ silicon sensors, to produce a scanner with 0.5 $\mathrm{\times}$ 0.5 $\mathrm{\times}$ 0.2…
▽ More
The TT-PET collaboration is develo** an MRI-compatible small animal PET scanner in which the sensitive element is a monolithic silicon pixel ASIC targeting 30 ps RMS time resolution. The photon-detection technique is based on a stack of alternating layers of high-Z photon converter and 100 $\mathrm{μm}$ silicon sensors, to produce a scanner with 0.5 $\mathrm{\times}$ 0.5 $\mathrm{\times}$ 0.2 $\mathrm{mm^{3}}$ granularity for precise depth-of-interaction measurement. In this paper we present the results of simulation studies for the expected data rate, time-of-flight and spatial resolution, as well as the performance of image reconstruction with and without the use of timing information.
△ Less
Submitted 12 March, 2019; v1 submitted 29 November, 2018;
originally announced December 2018.
-
Expected performance of the TT-PET scanner
Authors:
Emanuele Ripiccini,
Daiki Hayakawa,
Giuseppe Iacobucci,
Marzio Nessi,
Elzbieta Nowak,
Lorenzo Paolozzi,
Osman Ratib,
Pierpaolo Valerio,
Daniele Vitturini
Abstract:
The TT-PET collaboration is develo** a small animal TOF-PET scanner based on silicon detectors featuring 30 ps RMS time resolution and intended to be inserted in an existing MRI scanner. The TT-PET scanner makes use of a stack of layers of high-Z photon-converter and 100 $\mathrm{μm}$ thick silicon sensors, to achieve a scanner with 0.5 $\mathrm{\times}$ 0.5 $\mathrm{\times}$ 0.2…
▽ More
The TT-PET collaboration is develo** a small animal TOF-PET scanner based on silicon detectors featuring 30 ps RMS time resolution and intended to be inserted in an existing MRI scanner. The TT-PET scanner makes use of a stack of layers of high-Z photon-converter and 100 $\mathrm{μm}$ thick silicon sensors, to achieve a scanner with 0.5 $\mathrm{\times}$ 0.5 $\mathrm{\times}$ 0.2 $\mathrm{mm^{3}}$ granularity, with precise depth-of-interaction measurement. In this paper we present the results of the Monte Carlo studies for the expected data rate, time resolution on the TOF measurements, spatial resolution and image reconstruction with and without the use of the timing information. Most of the studies have been performed according to the international standards used to assess the performance of small-animal PET system.
△ Less
Submitted 29 November, 2018;
originally announced November 2018.
-
Characterization of the demonstrator of the fast silicon monolithic ASIC for the TT-PET project
Authors:
Lorenzo Paolozzi,
Yves Bandi,
Roberto Cardarelli,
Stephane Debieux,
Yannick Favre,
Didier Ferrere,
Dean Forshaw,
Daiki Hayakawa,
Giuseppe Iacobucci,
Mehmet Kaynak,
Antonio Miucci,
Marzio Nessi,
Emanuele Ripiccini,
Holger Ruecker,
Pierpaolo Valerio,
Michele Weber
Abstract:
The TT-PET collaboration is develo** a small animal TOF-PET scanner based on monolithic silicon pixel sensors in SiGe BiCMOS technology. The demonstrator chip, a small-scale version of the final detector ASIC, consists of a 3 x 10 pixel matrix integrated with the front-end, a 50 ps binning TDC and read out logic. The chip, thinned down to 100 μm and backside metallized, was operated at a voltage…
▽ More
The TT-PET collaboration is develo** a small animal TOF-PET scanner based on monolithic silicon pixel sensors in SiGe BiCMOS technology. The demonstrator chip, a small-scale version of the final detector ASIC, consists of a 3 x 10 pixel matrix integrated with the front-end, a 50 ps binning TDC and read out logic. The chip, thinned down to 100 μm and backside metallized, was operated at a voltage of 180 V. The tests on a beam line of minimum ionizing particles show a detection efficiency greater than 99.9 % and a time resolution down to 110 ps.
△ Less
Submitted 27 November, 2018;
originally announced November 2018.
-
A monolithic ASIC demonstrator for the Thin Time-of-Flight PET scanner
Authors:
Pierpaolo Valerio,
Roberto Cardarelli,
Giuseppe Iacobucci,
Lorenzo Paolozzi,
Emanuele Ripiccini,
Daiki Hayakawa,
Salvatore Bruno,
Alessandro Caltabiano,
Mehmet Kaynak,
Holger Rueker,
Marzio Nessi
Abstract:
Time-of-flight measurement is an important advancement in PET scanners to improve image reconstruction with a lower delivered radiation dose. This article describes the monolithic ASIC for the TT-PET project, a novel idea for a high-precision PET scanner for small animals. The chip uses a SiGe Bi-CMOS process for timing measurements, integrating a fully-depleted pixel matrix with a low-power BJT-b…
▽ More
Time-of-flight measurement is an important advancement in PET scanners to improve image reconstruction with a lower delivered radiation dose. This article describes the monolithic ASIC for the TT-PET project, a novel idea for a high-precision PET scanner for small animals. The chip uses a SiGe Bi-CMOS process for timing measurements, integrating a fully-depleted pixel matrix with a low-power BJT-based front-end per channel, integrated on the same 100 $μ m$ thick die. The target timing resolution is 30 ps RMS for electrons from the conversion of 511 keV photons. A novel synchronization scheme using a patent-pending TDC is used to allow the synchronization of 1.6 million channels across almost 2000 different chips at picosecond-level. A full-featured demonstrator chip with a 3x10 matrix of 500x500 $μ m^{2}$ pixels was produced to validate each block. Its design and experimental results are presented here.
△ Less
Submitted 26 November, 2018;
originally announced November 2018.
-
Test beam measurement of the first prototype of the fast silicon pixel monolithic detector for the TT-PET project
Authors:
L. Paolozzi,
Y. Bandi,
M. Benoit,
R. Cardarelli,
S. Débieux,
D. Forshaw,
D. Hayakawa,
G. Iacobucci,
M. Kaynak,
A. Miucci,
M. Nessi,
O. Ratib,
E. Ripiccini,
H. Rücker,
P. Valerio,
M. Weber
Abstract:
The TT-PET collaboration is develo** a PET scanner for small animals with 30 ps time-of-flight resolution and sub-millimetre 3D detection granularity. The sensitive element of the scanner is a monolithic silicon pixel detector based on state-of-the-art SiGe BiCMOS technology. The first ASIC prototype for the TT-PET was produced and tested in the laboratory and with minimum ionizing particles. Th…
▽ More
The TT-PET collaboration is develo** a PET scanner for small animals with 30 ps time-of-flight resolution and sub-millimetre 3D detection granularity. The sensitive element of the scanner is a monolithic silicon pixel detector based on state-of-the-art SiGe BiCMOS technology. The first ASIC prototype for the TT-PET was produced and tested in the laboratory and with minimum ionizing particles. The electronics exhibit an equivalent noise charge below 600 e- RMS and a pulse rise time of less than 2 ns, in accordance with the simulations. The pixels with a capacitance of 0.8 pF were measured to have a detection efficiency greater than 99% and, although in the absence of the post-processing, a time resolution of approximately 200 ps.
△ Less
Submitted 6 February, 2018; v1 submitted 5 February, 2018;
originally announced February 2018.
-
Pappus Theorem, Schwartz Representations and Anosov Representations
Authors:
Thierry Barbot,
Gye-Seon Lee,
Viviane Pardini Valério
Abstract:
In the paper "Pappus's theorem and the modular group", R. Schwartz constructed a 2-dimensional family of faithful representations $ρ_Θ$ of the modular group $\mathrm{PSL}(2,\mathbb{Z})$ into the group $\mathscr{G}$ of projective symmetries of the projective plane via Pappus Theorem. The image of the unique index 2 subgroup $\mathrm{PSL}(2,\mathbb{Z})_o$ of $\mathrm{PSL}(2,\mathbb{Z})$ under each r…
▽ More
In the paper "Pappus's theorem and the modular group", R. Schwartz constructed a 2-dimensional family of faithful representations $ρ_Θ$ of the modular group $\mathrm{PSL}(2,\mathbb{Z})$ into the group $\mathscr{G}$ of projective symmetries of the projective plane via Pappus Theorem. The image of the unique index 2 subgroup $\mathrm{PSL}(2,\mathbb{Z})_o$ of $\mathrm{PSL}(2,\mathbb{Z})$ under each representation $ρ_Θ$ is in the subgroup $\mathrm{PGL}(3,\mathbb{R})$ of $\mathscr{G}$ and preserves a topological circle in the flag variety, but $ρ_Θ$ is not Anosov. In her PhD Thesis, V. P. Valério elucidated the Anosov-like feature of Schwartz representations: For every $ρ_Θ$, there exists a 1-dimensional family of Anosov representations $ρ^\varepsilon_Θ$ of $\mathrm{PSL}(2,\mathbb{Z})_o$ into $\mathrm{PGL}(3,\mathbb{R})$ whose limit is the restriction of $ρ_Θ$ to $\mathrm{PSL}(2,\mathbb{Z})_o$. In this paper, we improve her work: For each $ρ_Θ$, we build a 2-dimensional family of Anosov representations of $\mathrm{PSL}(2,\mathbb{Z})_o$ into $\mathrm{PGL}(3,\mathbb{R})$ containing $ρ^\varepsilon_Θ$ and a 1-dimensional subfamily of which can extend to representations of $\mathrm{PSL}(2,\mathbb{Z})$ into $\mathscr{G}$. Schwartz representations are therefore, in a sense, the limits of Anosov representations of $\mathrm{PSL}(2,\mathbb{Z})$ into $\mathscr{G}$.
△ Less
Submitted 2 February, 2018; v1 submitted 13 October, 2016;
originally announced October 2016.
-
Updated baseline for a staged Compact Linear Collider
Authors:
The CLIC,
CLICdp collaborations,
:,
M. J. Boland,
U. Felzmann,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
C. Balazs,
T. K. Charles,
K. Afanaciev,
I. Emeliantchik,
A. Ignatenko,
V. Makarenko,
N. Shumeiko,
A. Patapenka,
I. Zhuk,
A. C. Abusleme Hoffman,
M. A. Diaz Gutierrez,
M. Vogel Gonzalez,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu
, et al. (493 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-q…
▽ More
The Compact Linear Collider (CLIC) is a multi-TeV high-luminosity linear e+e- collider under development. For an optimal exploitation of its physics potential, CLIC is foreseen to be built and operated in a staged approach with three centre-of-mass energy stages ranging from a few hundred GeV up to 3 TeV. The first stage will focus on precision Standard Model physics, in particular Higgs and top-quark measurements. Subsequent stages will focus on measurements of rare Higgs processes, as well as searches for new physics processes and precision measurements of new states, e.g. states previously discovered at LHC or at CLIC itself. In the 2012 CLIC Conceptual Design Report, a fully optimised 3 TeV collider was presented, while the proposed lower energy stages were not studied to the same level of detail. This report presents an updated baseline staging scenario for CLIC. The scenario is the result of a comprehensive study addressing the performance, cost and power of the CLIC accelerator complex as a function of centre-of-mass energy and it targets optimal physics output based on the current physics landscape. The optimised staging scenario foresees three main centre-of-mass energy stages at 380 GeV, 1.5 TeV and 3 TeV for a full CLIC programme spanning 22 years. For the first stage, an alternative to the CLIC drive beam scheme is presented in which the main linac power is produced using X-band klystrons.
△ Less
Submitted 27 March, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
What is the Brightest Source for Dilepton Emissions at RHIC?
Authors:
David Fein,
Zheng Huang,
Peter Valerio,
Ina Sarcevic
Abstract:
We calculate the dilepton emissions as the decay product of the charm and bottom quarks produced in heavy-ion collisions at RHIC energy. We take into account the next-to-leading-order radiative corrections in perturbative QCD to the heavy quark production from both an initial hard parton-parton scattering and an ideal quark-gluon plasma. We find that the thermal charm decay dominates the dilepto…
▽ More
We calculate the dilepton emissions as the decay product of the charm and bottom quarks produced in heavy-ion collisions at RHIC energy. We take into account the next-to-leading-order radiative corrections in perturbative QCD to the heavy quark production from both an initial hard parton-parton scattering and an ideal quark-gluon plasma. We find that the thermal charm decay dominates the dilepton production in the low dilepton mass region ($<2$ GeV), while the heavy quark production from the initial scattering takes over the intermediate and high mass regions ($> 2$ GeV). Our result also indicates the importance of the bottom quark in the high mass region ($>4 $ GeV ) due to its large mass and cascade decay. If the initial scattering produced charm suffers a significant energy loss due to the secondary interaction, the bottom decay constitutes the major background for the thermal dileptons.
△ Less
Submitted 9 July, 1996;
originally announced July 1996.
-
Charm Production in Hadronic and Heavy-Ion Collisions at RHIC and LHC Energies to $O(α_s^3)$
Authors:
Ina Sarcevic,
Peter Valerio
Abstract:
We present results on rapidity and transverse momentum distributions of inclusive charm quark production in hadronic and heavy-ion collisions at RHIC and LHC energies, including the next-to-leading order, $O(α_s^3)$, radiative corrections and the nuclear shadowing effect. We determine the hadronic and the {\it effective} (in-medium) K-factor for the differential and total inclusive charm cross s…
▽ More
We present results on rapidity and transverse momentum distributions of inclusive charm quark production in hadronic and heavy-ion collisions at RHIC and LHC energies, including the next-to-leading order, $O(α_s^3)$, radiative corrections and the nuclear shadowing effect. We determine the hadronic and the {\it effective} (in-medium) K-factor for the differential and total inclusive charm cross sections. We find the fraction of central and inelastic events that contain at least one charm quark pair at LHC energies and obtain the effective $A$-dependence of the inclusive charm production in proton-nucleus and nucleus-nucleus collisions at RHIC and in nucleus-nucleus collisions at the LHC. We discuss theoretical uncertainties inherent in our calculation. In particular, we show how different extrapolations of gluon density in a nucleon {\em and} in a nucleus to the low-$x$ region introduce large theoretical uncertainty in the calculation of charm production at LHC energies.
△ Less
Submitted 16 November, 1994;
originally announced November 1994.
-
Charm Production at RHIC to O(\ALPHA_S^3)
Authors:
I. Sarcevic,
P. Valerio
Abstract:
We present results on rapidity and transverse momentum distributions of inclusive charm quark production in heavy-ion collisions at RHIC, including the next-to-leading order, $O(α_s^3)$, radiative corrections and the nuclear shadowing effect. We find the effective, nuclear K-factor to be $K(y)\approx 1.4$ for $\mid y\mid \leq 3$ in the rapidity distribution, while $1\leq K(p_{T}) \leq 3$ for…
▽ More
We present results on rapidity and transverse momentum distributions of inclusive charm quark production in heavy-ion collisions at RHIC, including the next-to-leading order, $O(α_s^3)$, radiative corrections and the nuclear shadowing effect. We find the effective, nuclear K-factor to be $K(y)\approx 1.4$ for $\mid y\mid \leq 3$ in the rapidity distribution, while $1\leq K(p_{T}) \leq 3$ for $1GeV\leq p_T \leq 6GeV$ in the $p_T$ distribution. We incorporate multiple parton scatterings in our calculation of the fraction of all central events that contain at least one charm quark pair. We obtain the effective $A$-dependence of the charm cross sections. Finally, we comment on the possibility of detecting the quark-gluon plasma signal as an enhanced charm production in heavy-ion collisions at RHIC.
△ Less
Submitted 3 October, 1994; v1 submitted 2 May, 1994;
originally announced May 1994.