CLARION2-TRINITY: a Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions
Authors:
T. J. Gray,
J. M. Allmond,
D. T. Dowling,
M. Febbraro,
T. T. King,
S. D. Pain,
D. W. Stracener,
S. Ajayi,
J. Aragon,
L. Baby,
P. Barber,
C. Benetti,
S. Bhattacharya,
R. Boisseau,
J. Gibbons,
S. L. Tabor,
V. Tripathi,
C. Wibisono,
I. Wiedenhoever,
L. Bignell,
M. S. M. Gerathy,
G. Lane,
L. J. McKie,
A. J. Mitchell,
J. Pope
, et al. (4 additional authors not shown)
Abstract:
The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminium Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7-54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with mi…
▽ More
The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminium Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7-54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $γ$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors ($\approx4\%$ efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Finally, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from $^{16}$O + $^{18}$O fusion-evaporation, and PID and Doppler-corrected $γ$-ray spectra from $^{48}$Ti + $^{12}$C Coulomb excitation.
△ Less
Submitted 10 August, 2022;
originally announced August 2022.
-
Conceptual design and first results for a neutron detector with interaction localization capabilities
Authors:
J. Heideman,
D. Perez-Loureiro,
R. Grzywacz,
C. R. Thornsberry,
J. Chan,
L. H. Heilbronn,
S. K. Neupane,
K. Schmitt,
M. M. Rajabali,
A. R. Engelhardt,
C. W. Howell,
L. D. Mostella,
J. S. Owens,
S. C. Shadrick,
E. E. Peters,
A. P. D. Ramirez,
S. W. Yates,
K. Vaigneur
Abstract:
A new high-precision detector for studying neutrons from beta-delayed neutron emission and direct reaction studies is proposed. The Neutron dEtector with Xn Tracking (NEXT) array is designed to maintain high intrinsic neutron detection efficiency while reducing uncertainties in neutron energy measurements. A single NEXT module is composed of thin segments of plastic scintillator, each optically se…
▽ More
A new high-precision detector for studying neutrons from beta-delayed neutron emission and direct reaction studies is proposed. The Neutron dEtector with Xn Tracking (NEXT) array is designed to maintain high intrinsic neutron detection efficiency while reducing uncertainties in neutron energy measurements. A single NEXT module is composed of thin segments of plastic scintillator, each optically separated, capable of neutron-gamma discrimination. Each segmented module is coupled to position sensitive photodetectors enabling the high-precision determination of neutron time of arrival and interaction position within the active volume. A design study has been conducted based on simulations and experimental tests leading to the construction of prototype units. First results from measurements using a $^{252}$Cf neutron source and accelerator-produced monoenergetic neutrons are presented.
△ Less
Submitted 5 June, 2019; v1 submitted 31 March, 2019;
originally announced April 2019.
-
Segmented YSO scintillation detectors as a new ${\rm β}$-implant detection tool for decay spectroscopy in fragmentation facilities
Authors:
R. Yokoyama,
M. Singh,
R. Grzywacz,
A. Keeler,
T. T. King,
J. Agramunt,
N. T. Brewer,
S. Go,
J. Heideman,
J. Liu,
S. Nishimura,
P. Parkhurst,
V. H. Phong,
M. M. Rajabali,
B. C. Rasco,
K. P. Rykaczewski,
D. W. Stracener,
J. L. Tain,
A. Tolosa-Delgado,
K. Vaigneur,
M. Wolińska-Cichocka
Abstract:
A newly developed segmented YSO scintillator detector was implemented for the first time at the RI-beam Factory at RIKEN Nishina Center as an implantation-decay counter. The results from the experiment demonstrate that the detector is a viable alternative to conventional silicon-strip detectors with its good timing resolution and high detection efficiency for ${\rm β}$ particles. A Position-Sensit…
▽ More
A newly developed segmented YSO scintillator detector was implemented for the first time at the RI-beam Factory at RIKEN Nishina Center as an implantation-decay counter. The results from the experiment demonstrate that the detector is a viable alternative to conventional silicon-strip detectors with its good timing resolution and high detection efficiency for ${\rm β}$ particles. A Position-Sensitive Photo-Multiplier Tube (PSPMT) is coupled with a $48\times48$ segmented YSO crystal. To demonstrate its capabilities, a known short-lived isomer in $^{76}$Ni and the ${\rm β}$ decay of $^{74}$Co were measured by implanting those ions into the YSO detector. The half-lives and ${\rm γ}$-rays observed in this work are consistent with the known values. The ${\rm β}$-ray detection efficiency is more than 80~\% for the decay of $^{74}$Co.
△ Less
Submitted 7 May, 2019; v1 submitted 8 March, 2019;
originally announced March 2019.