-
Bond-Selective Full-Field Optical Coherence Tomography
Authors:
Haonan Zong,
Celalettin Yurdakul,
Jian Zhao,
Zian Wang,
Fukai Chen,
M. Selim Ünlü,
Ji-Xin Cheng
Abstract:
Optical coherence tomography (OCT) is a label-free, non-invasive 3D imaging tool widely used in both biological research and clinical diagnosis. Current OCT modalities can only visualize specimen tomography without chemical information. Here, we report a bondselective full-field OCT (BS-FF-OCT), in which a pulsed mid-infrared laser is used to modulate the OCT signal through the photothermal effect…
▽ More
Optical coherence tomography (OCT) is a label-free, non-invasive 3D imaging tool widely used in both biological research and clinical diagnosis. Current OCT modalities can only visualize specimen tomography without chemical information. Here, we report a bondselective full-field OCT (BS-FF-OCT), in which a pulsed mid-infrared laser is used to modulate the OCT signal through the photothermal effect, achieving label-free bond-selective 3D sectioned imaging of highly scattering samples. We first demonstrate BS-FF-OCT imaging of 1 μm PMMA beads embedded in agarose gel. Next, we then show 3D hyperspectral imaging of polypropylene fiber mattress from a standard surgical mask. We then demonstrate BS-FFOCT imaging on biological samples, including cancer cell spheroids and C. elegans. Using an alternative pulse timing configuration, we finally demonstrate the capability of BS-FF-OCT on a bulky and highly scattering 150 μm thick mouse brain slice.
△ Less
Submitted 30 January, 2023;
originally announced January 2023.
-
Single virus fingerprinting by widefield interferometric defocus-enhanced mid-infrared photothermal microscopy
Authors:
Qing Xia,
Zhongyue Guo,
Haonan Zong,
Scott Seitz,
Celalettin Yurdakul,
M. Selim Unlu,
Le Wang,
John H. Connor,
Ji-Xin Cheng
Abstract:
Clinical identification and fundamental study of viruses rely on the detection of viral proteins or viral nucleic acids. Yet, amplification-based and antigen-based methods are not able to provide precise compositional information of individual virions due to small particle size and low-abundance chemical contents (e.g., ~ 5000 proteins in a vesicular stomatitis virus). Here, we report a widefield…
▽ More
Clinical identification and fundamental study of viruses rely on the detection of viral proteins or viral nucleic acids. Yet, amplification-based and antigen-based methods are not able to provide precise compositional information of individual virions due to small particle size and low-abundance chemical contents (e.g., ~ 5000 proteins in a vesicular stomatitis virus). Here, we report a widefield interferometric defocus-enhanced mid-infrared photothermal (WIDE-MIP) microscope for high-throughput fingerprinting of single viruses. With the identification of feature absorption peaks, WIDE-MIP reveals the contents of viral proteins and nucleic acids in single DNA vaccinia viruses and RNA vesicular stomatitis viruses. Different nucleic acids signatures of thymine and uracil residue vibrations are obtained to differentiate DNA and RNA viruses. WIDE-MIP imaging further reveals an enriched \b{eta} sheet components in DNA varicella-zoster virus proteins. Together, these advances open a new avenue for compositional analysis of viral vectors and elucidating protein function in an assembled virion.
△ Less
Submitted 4 August, 2023; v1 submitted 20 December, 2022;
originally announced December 2022.
-
A spatially uniform illumination source for widefield multi-spectral optical microscopy
Authors:
Iris Celebi,
Mete Aslan,
M. Selim Unlu
Abstract:
Illumination uniformity is a critical parameter for excitation and data extraction quality in widefield biological imaging applications. However, typical imaging systems suffer from spatial and spectral non-uniformity due to non-ideal optical elements, thus require complex solutions for illumination corrections. We present Effective Uniform Color-Light Integration Device (EUCLID), a simple and cos…
▽ More
Illumination uniformity is a critical parameter for excitation and data extraction quality in widefield biological imaging applications. However, typical imaging systems suffer from spatial and spectral non-uniformity due to non-ideal optical elements, thus require complex solutions for illumination corrections. We present Effective Uniform Color-Light Integration Device (EUCLID), a simple and cost-effective illumination source for uniformity corrections. EUCLID employs a diffuse-reflective, adjustable hollow cavity that allows for uniform mixing of light from discrete light sources and modifies the source field distribution to compensate for spatial non-uniformity introduced by optical components in the imaging system. In this study, we characterize the light coupling efficiency of the proposed design and compare the uniformity performance with the conventional method. EUCLID demonstrates a remarkable illumination improvement for multi-spectral imaging in both Nelsonian and Koehler alignment with a maximum spatial deviation of ~1% across a wide field-of-view.
△ Less
Submitted 12 December, 2022;
originally announced December 2022.
-
Bond-selective interferometric scattering microscopy
Authors:
Celalettin Yurdakul,
Haonan Zong,
Yeran Bai,
Ji-Xin Cheng,
M. Selim Unlu
Abstract:
Interferometric scattering microscopy has been a very promising technology for highly sensitive label-free imaging of a broad spectrum of biological nanoparticles from proteins to viruses in a high-throughput manner. Although it can reveal the specimen's size and shape information, the chemical composition is inaccessible in interferometric measurements. Infrared spectroscopic imaging provides che…
▽ More
Interferometric scattering microscopy has been a very promising technology for highly sensitive label-free imaging of a broad spectrum of biological nanoparticles from proteins to viruses in a high-throughput manner. Although it can reveal the specimen's size and shape information, the chemical composition is inaccessible in interferometric measurements. Infrared spectroscopic imaging provides chemical specificity based on inherent chemical bond vibrations of specimens but lacks the ability to image and resolve individual nanoparticles due to long infrared wavelengths. Here, we describe a bond-selective interferometric scattering microscope where the mid-infrared induced photothermal signal is detected by a visible beam in a wide-field common-path interferometry configuration. A thin film layered substrate is utilized to reduce the reflected light and provide a reference field for the interferometric detection of the weakly scattered field. A pulsed mid-IR laser is employed to modulate the interferometric signal. Subsequent demodulation via a virtual lock-in camera offers simultaneous chemical information about tens of micro- or nano-particles. The chemical contrast arises from a minute change in the particle's scattered field in consequence of the vibrational absorption at the target molecule. We characterize the system with sub-wavelength polymer beads and highlight biological applications by chemically imaging several microorganisms including Staphylococcus aureus, Escherichia coli, and Candida albicans. A theoretical framework is established to extend bond-selective interferometric scattering microscopy to a broad range of biological micro- and nano-particles.
△ Less
Submitted 5 June, 2021;
originally announced June 2021.
-
Background-Suppressed High-Throughput Mid-Infrared Photothermal Microscopy via Pupil Engineering
Authors:
Haonan Zong,
Celalettin Yurdakul,
Yeran Bai,
Meng Zhang,
M. Selim Unlu,
Ji-Xin Cheng
Abstract:
Mid-infrared photothermal (MIP) microscopy has been a promising label-free chemical imaging technique for functional characterization of specimens owing to its enhanced spatial resolution and high specificity. Recently developed wide-field MIP imaging modalities have drastically improved speed and enabled high-throughput imaging of micron-scale subjects. However, the weakly scattered signal from s…
▽ More
Mid-infrared photothermal (MIP) microscopy has been a promising label-free chemical imaging technique for functional characterization of specimens owing to its enhanced spatial resolution and high specificity. Recently developed wide-field MIP imaging modalities have drastically improved speed and enabled high-throughput imaging of micron-scale subjects. However, the weakly scattered signal from sub-wavelength particles becomes indistinguishable from the shot-noise as a consequence of the strong background light, leading to limited sensitivity. Here, we demonstrate background-suppressed chemical fingerprinting at a single nanoparticle level by selectively attenuating the reflected light through pupil engineering in the collection path. Our technique provides over three orders of magnitude background suppression by quasi-darkfield illumination in epi-configuration without sacrificing lateral resolution. We demonstrate 6-fold signal-to-background noise ratio improvement, allowing for simultaneous detection and discrimination of hundreds of nanoparticles across a field of view of 70 um x 70 um. A comprehensive theoretical framework for photothermal image formation is provided and experimentally validated with 300 and 500~nm PMMA beads. The versatility and utility of our technique are demonstrated via hyperspectral dark-field MIP imaging of S. aureus and E. coli bacteria.
△ Less
Submitted 13 April, 2021;
originally announced April 2021.
-
Highly Sensitive and Label-free Digital Detection of Whole Cell E. coli with Interferometric Reflectance Imaging
Authors:
Negin Zaraee,
Fulya Ekiz kanik,
Abdul Muyeed Bhuiya,
Emily S. Gong,
Matthew T. Geib,
Nese Lortlar Ünlü,
Ayca Yalcin Ozkumur,
Julia R. Dupuis,
M. Selim Ünlü
Abstract:
Bacterial infectious diseases are a major threat to human health. Timely and sensitive pathogenic bacteria detection is crucial in identifying the bacterial contaminations and preventing the spread of infectious diseases. Due to limitations of conventional bacteria detection techniques there have been concerted research efforts towards development of new biosensors. Biosensors offering label free,…
▽ More
Bacterial infectious diseases are a major threat to human health. Timely and sensitive pathogenic bacteria detection is crucial in identifying the bacterial contaminations and preventing the spread of infectious diseases. Due to limitations of conventional bacteria detection techniques there have been concerted research efforts towards development of new biosensors. Biosensors offering label free, whole bacteria detection are highly desirable over those relying on label based or pathogenic molecular components detection. The major advantage is eliminating the additional time and cost required for labeling or extracting the desired bacterial components. Here, we demonstrate rapid, sensitive and label free E. coli detection utilizing interferometric reflectance imaging enhancement allowing for visualizing individual pathogens captured on the surface. Enabled by our ability to count individual bacteria on a large sensor surface, we demonstrate a limit of detection of 2.2 CFU/ml from a buffer solution with no sample preparation. To the best of our knowledge, this high level of sensitivity for whole E. coli detection is unprecedented in label free biosensing. The specificity of our biosensor is validated by comparing the response to target bacteria E. coli and non target bacteria S. aureus, K. pneumonia and P. aeruginosa. The biosensor performance in tap water also proves that its detection capability is unaffected by the sample complexity. Furthermore, our sensor platform provides high optical magnification imaging and thus validation of recorded detection events as the target bacteria based on morphological characterization. Therefore, our sensitive and label free detection method offers new perspectives for direct bacterial detection in real matrices and clinical samples.
△ Less
Submitted 15 November, 2019;
originally announced November 2019.
-
Beating the reaction limits of biosensor sensitivity with dynamic tracking of single binding events
Authors:
Derin Sevenler,
Jacob Trueb,
M. Selim Ünlü
Abstract:
The clinical need for ultra-sensitive molecular analysis has motivated the development of several endpoint assay technologies capable of single molecule readout. These endpoint assays are now primarily limited by the affinity and specificity of the molecular recognition agents for the analyte of interest. In contrast, a kinetic assay with single molecule readout could distinguish between low abund…
▽ More
The clinical need for ultra-sensitive molecular analysis has motivated the development of several endpoint assay technologies capable of single molecule readout. These endpoint assays are now primarily limited by the affinity and specificity of the molecular recognition agents for the analyte of interest. In contrast, a kinetic assay with single molecule readout could distinguish between low abundance, high affinity (specific analyte) and high abundance, low affinity (nonspecific background) binding by measuring the duration of individual binding events at equilibrium. Here we describe such a kinetic assay, in which individual binding events are detected and monitored during sample incubation. This method uses plasmonic gold nanorods and interferometric reflectance imaging to detect thousands of individual binding events across a multiplex solid phase sensor with a large area approaching that of leading bead-based endpoint assay technologies. A dynamic tracking procedure is used to measure the duration of each event. From this, the total rates of binding and de-binding as well as the distribution of binding event durations are determined. We observe a limit of detection of 15 femtomolar for a proof-of-concept synthetic DNA analyte in a 12-plex assay format.
△ Less
Submitted 12 September, 2018; v1 submitted 5 September, 2018;
originally announced September 2018.
-
A digital microarray using interferometric detection of plasmonic nanorod labels
Authors:
Derin Sevenler,
George Daaboul,
Fulya Ekiz-Kanik,
M. Selim Unlu
Abstract:
DNA and protein microarrays are a high-throughput technology that allow the simultaneous quantification of tens of thousands of different biomolecular species. The mediocre sensitivity and dynamic range of traditional fluorescence microarrays compared to other techniques have been the technology's Achilles' Heel, and prevented their adoption for many biomedical and clinical diagnostic applications…
▽ More
DNA and protein microarrays are a high-throughput technology that allow the simultaneous quantification of tens of thousands of different biomolecular species. The mediocre sensitivity and dynamic range of traditional fluorescence microarrays compared to other techniques have been the technology's Achilles' Heel, and prevented their adoption for many biomedical and clinical diagnostic applications. Previous work to enhance the sensitivity of microarray readout to the single-molecule ('digital') regime have either required signal amplifying chemistry or sacrificed throughput, nixing the platform's primary advantages. Here, we report the development of a digital microarray which extends both the sensitivity and dynamic range of microarrays by about three orders of magnitude. This technique uses functionalized gold nanorods as single-molecule labels and an interferometric scanner which can rapidly enumerate individual nanorods by imaging them with a 10x objective lens. This approach does not require any chemical enhancement such as silver deposition, and scans arrays with a throughput similar to commercial fluorescence devices. By combining single-nanoparticle enumeration and ensemble measurements of spots when the particles are very dense, this system achieves a dynamic range of about one million directly from a single scan.
△ Less
Submitted 23 January, 2018;
originally announced January 2018.
-
Nanoparticle Classification in Wide-field Interferometric Microscopy by Supervised Learning from Model
Authors:
Oguzhan Avci,
Celalettin Yurdakul,
M. Selim Unlu
Abstract:
Interference enhanced wide-field nanoparticle imaging is a highly sensitive technique that has found numerous applications in labeled and label-free sub-diffraction-limited pathogen detection. It also provides unique opportunities for nanoparticle classification upon detection. More specif- ically, the nanoparticle defocus images result in a particle-specific response that can be of great utility…
▽ More
Interference enhanced wide-field nanoparticle imaging is a highly sensitive technique that has found numerous applications in labeled and label-free sub-diffraction-limited pathogen detection. It also provides unique opportunities for nanoparticle classification upon detection. More specif- ically, the nanoparticle defocus images result in a particle-specific response that can be of great utility for nanoparticle classification, particularly based on type and size. In this work, we com- bine a model based supervised learning algorithm with a wide-field common-path interferometric microscopy method to achieve accurate nanoparticle classification. We verify our classification schemes experimentally by using gold and polystyrene nanospheres.
△ Less
Submitted 8 March, 2017;
originally announced March 2017.
-
Rapid map** of digital integrated circuit logic gates via multi-spectral backside imaging
Authors:
Ronen Adato,
Aydan Uyar,
Mahmoud Zangeneh,
Boyou Zhou,
Ajay Joshi,
Bennett Goldberg,
M Selim Unlu
Abstract:
Modern semiconductor integrated circuits are increasingly fabricated at untrusted third party foundries. There now exist myriad security threats of malicious tampering at the hardware level and hence a clear and pressing need for new tools that enable rapid, robust and low-cost validation of circuit layouts. Optical backside imaging offers an attractive platform, but its limited resolution and thr…
▽ More
Modern semiconductor integrated circuits are increasingly fabricated at untrusted third party foundries. There now exist myriad security threats of malicious tampering at the hardware level and hence a clear and pressing need for new tools that enable rapid, robust and low-cost validation of circuit layouts. Optical backside imaging offers an attractive platform, but its limited resolution and throughput cannot cope with the nanoscale sizes of modern circuitry and the need to image over a large area. We propose and demonstrate a multi-spectral imaging approach to overcome these obstacles by identifying key circuit elements on the basis of their spectral response. This obviates the need to directly image the nanoscale components that define them, thereby relaxing resolution and spatial sampling requirements by 1 and 2 - 4 orders of magnitude respectively. Our results directly address critical security needs in the integrated circuit supply chain and highlight the potential of spectroscopic techniques to address fundamental resolution obstacles caused by the need to image ever shrinking feature sizes in semiconductor integrated circuits.
△ Less
Submitted 30 May, 2016;
originally announced May 2016.
-
Scaling of exciton binding energy with external dielectric function in carbon nanotubes
Authors:
Andrew G. Walsh,
A. Nickolas Vamivakas,
Yan Yin,
Stephen B. Cronin,
M. Selim Unlu,
Bennett B. Goldberg,
Anna K. Swan
Abstract:
We develop a scaling relationship between the exciton binding energy and the external dielectric function in carbon nanotubes. We show that the electron-electron and electron-hole interaction energies are strongly affected by screening yet largely counteract each other, resulting in much smaller changes in the optical transition energy. The model indicates that the relevant particle interaction…
▽ More
We develop a scaling relationship between the exciton binding energy and the external dielectric function in carbon nanotubes. We show that the electron-electron and electron-hole interaction energies are strongly affected by screening yet largely counteract each other, resulting in much smaller changes in the optical transition energy. The model indicates that the relevant particle interaction energies are reduced by as much as 50 percent upon screening by water and that the unscreened electron-electron interaction energy is larger than the unscreened electron-hole interaction energy, in agreement with explanations of the "ratio problem." We apply the model to measurements of the changes in the optical transistion energies in single, suspended carbon nanotubes as the external dielectric environment is altered.
△ Less
Submitted 12 July, 2007;
originally announced July 2007.
-
Strong extinction of a far-field laser beam by a single quantum dot
Authors:
A. N. Vamivakas,
M. Atature,
J. Dreiser,
S. T. Yilmaz,
A. Badolato,
A. K. Swan,
B. B. Goldberg,
A. Imamoglu,
M. S. Unlu
Abstract:
Through the utilization of index-matched GaAs immersion lens techniques we demonstrate a record extinction (12%) of a far-field focused laser by a single InAs/GaAs quantum dot. This contrast level enables us to report for the first time resonant laser transmission spectroscopy on a single InAs/GaAs quantum dot without the need for phase-sensitive lock-in detection.
Through the utilization of index-matched GaAs immersion lens techniques we demonstrate a record extinction (12%) of a far-field focused laser by a single InAs/GaAs quantum dot. This contrast level enables us to report for the first time resonant laser transmission spectroscopy on a single InAs/GaAs quantum dot without the need for phase-sensitive lock-in detection.
△ Less
Submitted 20 June, 2007;
originally announced June 2007.
-
Screening of Excitons in Single, Suspended Carbon Nanotubes
Authors:
Andrew G. Walsh,
A. Nickolas Vamivakas,
Yan Yin,
Stephen B. Cronin,
M. Selim Unlu,
Bennett B. Goldberg,
Anna K. Swan
Abstract:
Resonant Raman spectroscopy of single carbon nanotubes suspended across trenches displays red shifts of up to 30 meV of the electronic transition energies as a function of the surrounding dielectric environment. We develop a simple scaling relationship between the exciton binding energy and the external dielectric function and thus quantify the effect of screening. Our results imply that the und…
▽ More
Resonant Raman spectroscopy of single carbon nanotubes suspended across trenches displays red shifts of up to 30 meV of the electronic transition energies as a function of the surrounding dielectric environment. We develop a simple scaling relationship between the exciton binding energy and the external dielectric function and thus quantify the effect of screening. Our results imply that the underlying particle interaction energies change by hundreds of meV.
△ Less
Submitted 19 April, 2007;
originally announced April 2007.
-
Phase sensitive detection of dipole radiation in a fiber-based high numerical aperture optical system
Authors:
A. N. Vamivakas,
M. Dogan,
S. B. Ippolito,
E. R. Behringer,
A. K. Swan,
B. B. Goldberg,
M. S. Unlu
Abstract:
We theoretically study the problem of detecting dipole radiation in an optical system of high numerical aperture in which the detector is sensitive to \textit{field amplitude}. In particular, we model the phase sensitive detector as a single-mode cylindrical optical fiber. We find that the maximum in collection efficiency of the dipole radiation does not coincide with the optimum resolution for…
▽ More
We theoretically study the problem of detecting dipole radiation in an optical system of high numerical aperture in which the detector is sensitive to \textit{field amplitude}. In particular, we model the phase sensitive detector as a single-mode cylindrical optical fiber. We find that the maximum in collection efficiency of the dipole radiation does not coincide with the optimum resolution for the light gathering instrument. The calculated results are important for analyzing fiber-based confocal microscope performance in fluorescence and spectroscopic studies of single molecules and/or quantum dots.
△ Less
Submitted 20 September, 2006;
originally announced September 2006.
-
Chirality dependence of the radial breathing phonon mode density in single wall carbon nanotubes
Authors:
A. N. Vamivakas,
Y. Yin,
A. G. Walsh,
M. S. Unlu,
B. B. Goldberg,
A. K. Swan
Abstract:
A mass and spring model is used to calculate the phonon mode dispersion for single wall carbon nanotubes (SWNTs) of arbitrary chirality. The calculated dispersions are used to determine the chirality dependence of the radial breathing phonon mode (RBM) density. Van Hove singularities, usually discussed in the context of the single particle electronic excitation spectrum, are found in the RBM den…
▽ More
A mass and spring model is used to calculate the phonon mode dispersion for single wall carbon nanotubes (SWNTs) of arbitrary chirality. The calculated dispersions are used to determine the chirality dependence of the radial breathing phonon mode (RBM) density. Van Hove singularities, usually discussed in the context of the single particle electronic excitation spectrum, are found in the RBM density of states with distinct qualitative differences for zig zag, armchair and chiral SWNTs. The influence the phonon mode density has on the two phonon resonant Raman scattering cross-section is discussed.
△ Less
Submitted 8 September, 2006;
originally announced September 2006.
-
Tunable Resonant Raman Scattering from Singly Resonant Single Wall Carbon Nanotubes
Authors:
Y. Yin,
A. G. Walsh,
A. N. Vamivakas,
S. Cronin,
A. M. Stolyarov,
M. Tinkham,
W. Bacsa,
M. S. Unlu,
B. B. Goldberg,
A. K. Swan
Abstract:
We perform tunable resonant Raman scattering on 17 semiconducting and 7 metallic singly resonant single wall carbon nanotubes. The measured scattering cross-section as a function laser energy provides information about a tube's electronic structure, the lifetime of intermediate states involved in the scattering process and also energies of zone center optical phonons. Recording the scattered Ram…
▽ More
We perform tunable resonant Raman scattering on 17 semiconducting and 7 metallic singly resonant single wall carbon nanotubes. The measured scattering cross-section as a function laser energy provides information about a tube's electronic structure, the lifetime of intermediate states involved in the scattering process and also energies of zone center optical phonons. Recording the scattered Raman signal as a function of tube location in the microscope focal plane allows us to construct two-dimensional spatial maps of singly resonant tubes. We also describe a spectral nanoscale artifact we have coined the "nano-slit effect".
△ Less
Submitted 1 June, 2006;
originally announced June 2006.
-
Optical Determination of Electron-Phonon Coupling in Carbon Nanotubes
Authors:
Y. Yin,
A. Vamivakas,
A. Walsh,
S. Cronin,
M. S. Unlu,
B. B Goldberg,
A. K. Swan
Abstract:
We report on an optical method to directly measure electron-phonon coupling in carbon nanotubes by correlating the first and second harmonic of the resonant Raman excitation profile. The method is applicable to 1D and 0D systems and is not limited to materials that exhibit photoluminescence. Experimental results for electron-phonon coupling with the radial breathing mode in 5 different nanotubes…
▽ More
We report on an optical method to directly measure electron-phonon coupling in carbon nanotubes by correlating the first and second harmonic of the resonant Raman excitation profile. The method is applicable to 1D and 0D systems and is not limited to materials that exhibit photoluminescence. Experimental results for electron-phonon coupling with the radial breathing mode in 5 different nanotubes show coupling strengths from 3-11 meV, depending on chirality. The results are in good agreement with the chirality and diameter dependence calculated by Goupalov et al.
△ Less
Submitted 11 June, 2006; v1 submitted 26 May, 2006;
originally announced May 2006.
-
Exciton mediated one phonon resonant Raman scattering from one-dimensional systems
Authors:
A. N. Vamivakas,
A. Walsh,
Y. Yin,
M. S. Unlu,
B. B. Goldberg,
A. K. Swan
Abstract:
We use the Kramers-Heisenberg approach to derive a general expression for the resonant Raman scattering cross section from a one-dimensional (1D) system explicitly accounting for excitonic effects. The result should prove useful for analyzing the Raman resonance excitation profile lineshapes for a variety of 1D systems including carbon nanotubes and semiconductor quantum wires. We apply this for…
▽ More
We use the Kramers-Heisenberg approach to derive a general expression for the resonant Raman scattering cross section from a one-dimensional (1D) system explicitly accounting for excitonic effects. The result should prove useful for analyzing the Raman resonance excitation profile lineshapes for a variety of 1D systems including carbon nanotubes and semiconductor quantum wires. We apply this formalism to a simple 1D model system to illustrate the similarities and differences between the free electron and correlated electron-hole theories.
△ Less
Submitted 21 April, 2006;
originally announced April 2006.
-
Intrinsic Optical Transition Energies in Carbon Nanotubes
Authors:
Yan Yin,
Stephen Cronin,
Andrew Walsh,
Alexander Stolyarov,
Michael Tinkham,
Anthony Vamivakas,
Wolfgang Bacsa,
M. Selim Unlu,
Bennett B Goldberg,
Anna K. Swan
Abstract:
Intrinsic optical transition energies for isolated and individual single wall carbon nanotubes grown over trenches are measured using tunable resonant Raman scattering. Previously measured E22_S optical transitions from nanotubes in surfactants are blue shifted 70-90 meV with respect to our measurements of nanotubes in air. This large shift in the exciton energy is attributed to a larger change…
▽ More
Intrinsic optical transition energies for isolated and individual single wall carbon nanotubes grown over trenches are measured using tunable resonant Raman scattering. Previously measured E22_S optical transitions from nanotubes in surfactants are blue shifted 70-90 meV with respect to our measurements of nanotubes in air. This large shift in the exciton energy is attributed to a larger change of the exciton binding energy than the band-gap renormalization as the surrounding dielectric constant increases.
△ Less
Submitted 31 May, 2006; v1 submitted 29 April, 2005;
originally announced May 2005.