Speeding up Photoacoustic Imaging using Diffusion Models
Authors:
Irem Loc,
Mehmet Burcin Unlu
Abstract:
Background: Photoacoustic Microscopy (PAM) integrates optical and acoustic imaging, offering enhanced penetration depth for detecting optical-absorbing components in tissues. Nonetheless, challenges arise in scanning large areas with high spatial resolution. With speed limitations imposed by laser pulse repetition rates, the potential role of computational methods is highlighted in accelerating PA…
▽ More
Background: Photoacoustic Microscopy (PAM) integrates optical and acoustic imaging, offering enhanced penetration depth for detecting optical-absorbing components in tissues. Nonetheless, challenges arise in scanning large areas with high spatial resolution. With speed limitations imposed by laser pulse repetition rates, the potential role of computational methods is highlighted in accelerating PAM imaging. Purpose: We are proposing a novel and highly adaptable DiffPam algorithm that utilizes diffusion models for speeding up the photoacoustic imaging process. Method: We leveraged a diffusion model trained exclusively on natural images, comparing its performance with an in-domain trained U-Net model using a dataset focused on PAM images of mice brain microvasculature. Results: Our findings indicate that DiffPam achieves comparable performance to a dedicated U-Net model, without the need for a large dataset or training a deep learning model. The study also introduces the efficacy of shortened diffusion processes for reducing computing time without compromising accuracy. Conclusion: This study underscores the significance of DiffPam as a practical algorithm for reconstructing undersampled PAM images, particularly for researchers with limited AI expertise and computational resources.
△ Less
Submitted 14 December, 2023;
originally announced December 2023.
-
Calibration of scanning acoustic microscopy for the differentiation between unstable and stable atherosclerotic plaques by X-ray fluorescence imaging
Authors:
Peter Modregger,
Mallika Khosla,
Prerana Chakrabarti,
Özgül Öztürk,
Kathryn M. Spiers,
Mehmet Burcin Unlu,
Bükem Tanören
Abstract:
Although cardiovascular diseases are the leading cause of death globally, non-invasive and inexpensive diagnostic tools for the identification of associated unstable atherosclerotic plaques are not yet available. Scanning acoustic microscopy offers a high potential to fill this critical gap in patient care. However, convincing validation and calibration of this technique requires high resolution m…
▽ More
Although cardiovascular diseases are the leading cause of death globally, non-invasive and inexpensive diagnostic tools for the identification of associated unstable atherosclerotic plaques are not yet available. Scanning acoustic microscopy offers a high potential to fill this critical gap in patient care. However, convincing validation and calibration of this technique requires high resolution maps of Ca concentrations of atherosclerotic plaques. Here, we demonstrate that synchrotron radiation-based X-ray fluorescence imaging with micrometer spatial resolution can provide such a gold standard.
△ Less
Submitted 4 May, 2022; v1 submitted 14 April, 2022;
originally announced April 2022.
-
Evaluation of Adjoint Methods in Photoacoustic Tomography with Under-Sampled Sensors
Authors:
Hongxiang Lin,
Takashi Azuma,
Mehmet Burcin Unlu,
Shu Takagi
Abstract:
Photo-Acoustic Tomography (PAT) can reconstruct a distribution of optical absorbers acting as instantaneous sound sources in subcutaneous microvasculature of a human breast. Adjoint methods for PAT, typically Time-Reversal (TR) and Back-Projection (BP), are ways to refocus time-reversed acoustic signals on sources by wave propagation from the position of sensors. TR and BP have different treatment…
▽ More
Photo-Acoustic Tomography (PAT) can reconstruct a distribution of optical absorbers acting as instantaneous sound sources in subcutaneous microvasculature of a human breast. Adjoint methods for PAT, typically Time-Reversal (TR) and Back-Projection (BP), are ways to refocus time-reversed acoustic signals on sources by wave propagation from the position of sensors. TR and BP have different treatments for received signals, but they are equivalent under continuously sampling on a closed circular sensor array in two dimensions. Here, we analyze image quality with discrete under-sampled sensors in the sense of the Shannon sampling theorem. We investigate resolution and contrast of TR and BP, respectively in one source-sensor pair configuration and the frequency domain. With Hankel's asymptotic expansion to the integrands of imaging functions, our main contribution is to demonstrate that TR and BP have better performance on contrast and resolution, respectively. We also show that the integrand of TR includes additional side lobes which degrade axial resolution whereas that of BP conversely has relatively small amplitudes. Moreover, omnidirectional resolution is improved if more sensors are employed to collect the received signals. Nevertheless, for the under-sampled sensors, we propose the Truncated Back-Projection (TBP) method to enhance the contrast of BP using removing higher frequency components in the received signals. We conduct numerical experiments on the two-dimensional projected phantom model extracted from OA-Breast Database. The experiments verify our theories and show that the proposed TBP possesses better omnidirectional resolution as well as contrast compared with TR and BP with under-sampled sensors.
△ Less
Submitted 22 June, 2018;
originally announced June 2018.
-
Simple analytic model for radiotherapeutic X-ray induced acoustic signal as a function of absorption parameters
Authors:
Canberk Sanli,
Esra Aytac Kipergil,
Mehmet Burcin Unlu
Abstract:
It is possible to make image reconstruction based on the dose dependence of the therapeutic XA (X-ray induced acoustic signal) amplitude which is then used to make dose map**. We give further explicit parametrization for the acoustic signal in terms of the absorption parameters based on a physical model of the absorption process. The first step is to obtain pressure waveform due to a point dose…
▽ More
It is possible to make image reconstruction based on the dose dependence of the therapeutic XA (X-ray induced acoustic signal) amplitude which is then used to make dose map**. We give further explicit parametrization for the acoustic signal in terms of the absorption parameters based on a physical model of the absorption process. The first step is to obtain pressure waveform due to a point dose absorption by solving the thermo-acoustic equation governing the heat absorption-pressure induction process based on the analytic integration technique. Then, clinically relevant XA signal profile at the detection point is obtained by generalizing point-dose-gradient induced acoustic signal to surface-dose-gradient of a uniform spherical 3D dose distribution based on the reciprocity principle for pressure waves in fluid media. Therapeutic XA signal induced from the surface of the uniform spherical dose distribution due to X-ray irradiation onto $5x5$ $cm^2$ field of the water surface by $1~μs$ pulses delivering $1.7$ mGy/pulse is simulated in time and frequency domain. XA waves obtained in previous empirical studies are simulated and compared by means of shape and relative amplitude. Considering the previous studies on this subject, we believe that the significance of this study is the foundation of a novel and self-contained analytic approach to simulate the therapeutic X-ray acoustic waves based on the physical parametrization of the energy transfer process. This not only provides a better understanding of the physical phenomena underlying the medical technique in terms of the medically relevant parameters such as field size, pulse duration, absorbed dose per pulse etc. together with the physical assumptions used to obtain a solution to the photo-acoustic equation, but also brings consistent simulation results with previous experimental and k-Wave results.
△ Less
Submitted 18 January, 2018;
originally announced January 2018.
-
Wigner Function Formalism for Zero Magnetic Field Spin Dependent Resonant Tunneling Structures
Authors:
Mehmet Burcin Unlu,
Hong-Liang Cui
Abstract:
We develop a Wigner function representation of the quantum transport theory of the conduction band electrons in Rashba effect resonant tunneling structures with a phonon bath. In narrow band gap heterostructures, spin splitting occurs mainly as a result of inversion asymmetry in the spatial dependence of the potential or as a result of external electric field. This "zero magnetic field spin spli…
▽ More
We develop a Wigner function representation of the quantum transport theory of the conduction band electrons in Rashba effect resonant tunneling structures with a phonon bath. In narrow band gap heterostructures, spin splitting occurs mainly as a result of inversion asymmetry in the spatial dependence of the potential or as a result of external electric field. This "zero magnetic field spin splitting" is due to the Rashba term in the effective mass Hamiltonian. The quantum transport equations are derived using multi-band non-equilibrium Green's function formulation in generalized Kadanoff-Baym ansatz.
△ Less
Submitted 23 September, 2004; v1 submitted 22 September, 2004;
originally announced September 2004.
-
Multi-band Wigner Function Formulation of Quantum Transport
Authors:
Mehmet Burcin Unlu,
Bernard Rosen,
Hong-Liang Cui,
Peiji Zhao
Abstract:
A Wigner function representation of multi-band quantum transport theory is developed in this paper. The equations are derived using non-equilibrium Green's function formulation with the generalized Kadanoff-Baym ansatz and the multi-band $\bf{k.p}$ Hamiltonian including spin. The results are applied to a two-band resonant inter-band tunneling structure.
A Wigner function representation of multi-band quantum transport theory is developed in this paper. The equations are derived using non-equilibrium Green's function formulation with the generalized Kadanoff-Baym ansatz and the multi-band $\bf{k.p}$ Hamiltonian including spin. The results are applied to a two-band resonant inter-band tunneling structure.
△ Less
Submitted 8 July, 2004;
originally announced July 2004.