-
Few-electron highly charged muonic Ar atoms verified by electronic $K$ x rays
Authors:
T. Okumura,
T. Azuma,
D. A. Bennett,
W. B. Doriese,
M. S. Durkin,
J. W. Fowler,
J. D. Gard,
T. Hashimoto,
R. Hayakawa,
Y. Ichinohe,
P. Indelicato,
T. Isobe,
S. Kanda,
D. Kato,
M. Katsuragawa,
N. Kawamura,
Y. Kino,
N. Kominato,
Y. Miyake,
K. M. Morgan,
H. Noda,
G. C. O'Neil,
S. Okada,
K. Okutsu,
N. Paul
, et al. (18 additional authors not shown)
Abstract:
Electronic $K$ x rays emitted by muonic Ar atoms in the gas phase were observed using a superconducting transition-edge-sensor microcalorimeter. The high-precision energy spectra provided a clear signature of the presence of muonic atoms accompanied by a few electrons, which have never been observed before. One-, two-, and three-electron bound, i.e., H-like, He-like, and Li-like, muonic Ar atoms w…
▽ More
Electronic $K$ x rays emitted by muonic Ar atoms in the gas phase were observed using a superconducting transition-edge-sensor microcalorimeter. The high-precision energy spectra provided a clear signature of the presence of muonic atoms accompanied by a few electrons, which have never been observed before. One-, two-, and three-electron bound, i.e., H-like, He-like, and Li-like, muonic Ar atoms were identified from electronic $K$ x rays and hyper-satellite $K$ x rays. These $K$ x rays are emitted after the charge transfer process by the collisions with surrounding Ar atoms. With the aid of theoretical calculations, we confirmed that the peak positions are consistent with the x-ray energies from highly charged Cl ions, and the intensities reflecting deexcitation dynamics were successfully understood by taking into account the interaction between the muon and bound electrons.
△ Less
Submitted 10 July, 2024;
originally announced July 2024.
-
Kinetic inductance current sensor for visible to near-infrared wavelength transition-edge sensor readout
Authors:
Paul Szypryt,
Douglas A. Bennett,
Ian Fogarty Florang,
Joseph W. Fowler,
Andrea Giachero,
Ruslan Hummatov,
Adriana E. Lita,
John A. B. Mates,
Sae Woo Nam,
Galen C. O'Neil,
Daniel S. Swetz,
Joel N. Ullom,
Michael R. Vissers,
Jordan Wheeler,
Jiansong Gao
Abstract:
Single-photon detectors based on the superconducting transition-edge sensor (TES) are used in a number of visible to near-infrared (VNIR) applications, particularly for photon-number-resolving measurements in quantum information science. To be practical for large-scale photonic quantum computing or for future spectroscopic imaging applications in astronomy, the size of VNIR TES arrays must be incr…
▽ More
Single-photon detectors based on the superconducting transition-edge sensor (TES) are used in a number of visible to near-infrared (VNIR) applications, particularly for photon-number-resolving measurements in quantum information science. To be practical for large-scale photonic quantum computing or for future spectroscopic imaging applications in astronomy, the size of VNIR TES arrays must be increased from a few pixels to many thousands. Historically, TES arrays have been read out with multiplexed superconducting quantum interference devices (SQUIDs), but the microsecond-duration pulse signals of VNIR TESs are notoriously difficult to multiplex. In this manuscript, we introduce the kinetic inductance current sensor (KICS), a more readily scalable readout technology that exploits the nonlinear kinetic inductance in a superconducting resonator to make sensitive current measurements. KICS devices can replace SQUIDs for many applications because of their ability to measure fast, high slew-rate signals, their compatibility with standard microwave frequency-division multiplexing techniques, and their relatively simple fabrication. Here, we demonstrate the readout of a VNIR TES using a KICS with $3.7$ $\text{MHz}$ of bandwidth. We measure a readout noise of $1.4$ $\text{pA}/\sqrt{\text{Hz}}$, considerably below the TES noise at frequencies of interest, and a TES energy resolution of $(0.137 \pm 0.001)$ $\text{eV}$ at $0.8$ $\text{eV}$, comparable to resolutions observed with non-multiplexed SQUID readouts.
△ Less
Submitted 23 May, 2024;
originally announced May 2024.
-
Simons Observatory: Pre-deployment Performance of a Large Aperture Telescope Optics Tube in the 90 and 150 GHz Spectral Bands
Authors:
Carlos E. Sierra,
Kathleen Harrington,
Shreya Sutariya,
Thomas Alford,
Anna M. Kofman,
Grace E. Chesmore,
Jason E. Austermann,
Andrew Bazarko,
James A. Beall,
Tanay Bhandarkar,
Mark J. Devlin,
Simon R. Dicker,
Peter N. Dow,
Shannon M. Duff,
Daniel Dutcher,
Nicholas Galitzki,
Joseph E. Golec,
John C. Groh,
Jon E. Gudmundsson,
Saianeesh K. Haridas,
Erin Healy,
Johannes Hubmayr,
Jeffrey Iuliano,
Bradley R. Johnson,
Claire S. Lessler
, et al. (20 additional authors not shown)
Abstract:
The Simons Observatory will map the temperature and polarization over half of the sky, at millimeter wavelengths in six spectral bands from the Atacama Desert in Chile. These data will provide new insights into the genesis, content, and history of our Universe; the astrophysics of galaxies and galaxy clusters; objects in our solar system; and time-varying astrophysical phenomena. This ambitious ne…
▽ More
The Simons Observatory will map the temperature and polarization over half of the sky, at millimeter wavelengths in six spectral bands from the Atacama Desert in Chile. These data will provide new insights into the genesis, content, and history of our Universe; the astrophysics of galaxies and galaxy clusters; objects in our solar system; and time-varying astrophysical phenomena. This ambitious new instrument suite, initially comprising three 0.5 m small-aperture telescopes and one 6 m large aperture telescope, is designed using a common combination of new technologies and new implementations to realize an observatory significantly more capable than the previous generation. In this paper, we present the pre-deployment performance of the first mid-frequency "optics tube" which will be fielded on the large aperture telescope with sensitivity to the 90 and 150 GHz spectral bands. This optics tube contains lenses, filters, detectors, and readout components, all of which operate at cryogenic temperatures. It is one of seven that form the core of the large aperture telescope receiver in its initial deployment. We describe this optics tube, including details of comprehensive testing methods, new techniques for beam and passband characterization, and its measured performance. The performance metrics include beams, optical efficiency, passbands, and forecasts for the on-sky performance of the system. We forecast a sensitivity that exceeds the requirements of the large aperture telescope with greater than 30% margin in each spectral band, and predict that the instrument will realize diffraction-limited performance and the expected detector passbands.
△ Less
Submitted 10 May, 2024;
originally announced May 2024.
-
The Simons Observatory: Design, integration, and testing of the small aperture telescopes
Authors:
Nicholas Galitzki,
Tran Tsan,
Jake Spisak,
Michael Randall,
Max Silva-Feaver,
Joseph Seibert,
Jacob Lashner,
Shunsuke Adachi,
Sean M. Adkins,
Thomas Alford,
Kam Arnold,
Peter C. Ashton,
Jason E. Austermann,
Carlo Baccigalupi,
Andrew Bazarko,
James A. Beall,
Sanah Bhimani,
Bryce Bixler,
Gabriele Coppi,
Lance Corbett,
Kevin D. Crowley,
Kevin T. Crowley,
Samuel Day-Weiss,
Simon Dicker,
Peter N. Dow
, et al. (55 additional authors not shown)
Abstract:
The Simons Observatory (SO) is a cosmic microwave background (CMB) survey experiment that includes small-aperture telescopes (SATs) observing from an altitude of 5,200 m in the Atacama Desert in Chile. The SO SATs will cover six spectral bands between 27 and 280 GHz to search for primordial B-modes to a sensitivity of $σ(r)=0.002$, with quantified systematic errors well below this value. Each SAT…
▽ More
The Simons Observatory (SO) is a cosmic microwave background (CMB) survey experiment that includes small-aperture telescopes (SATs) observing from an altitude of 5,200 m in the Atacama Desert in Chile. The SO SATs will cover six spectral bands between 27 and 280 GHz to search for primordial B-modes to a sensitivity of $σ(r)=0.002$, with quantified systematic errors well below this value. Each SAT is a self-contained cryogenic telescope with a 35$^\circ$ field of view, 42 cm diameter optical aperture, 40 K half-wave plate, 1 K refractive optics, and $<0.1$ K focal plane that holds $>12,000$ TES detectors. We describe the nominal design of the SATs and present details about the integration and testing for one operating at 93 and 145 GHz.
△ Less
Submitted 10 May, 2024; v1 submitted 9 May, 2024;
originally announced May 2024.
-
Spectroscopic measurements and models of energy deposition in the substrate of quantum circuits by natural ionizing radiation
Authors:
Joseph W. Fowler,
Paul Szypryt,
Raymond Bunker,
Ellen R. Edwards,
Ian Fogarty Florang,
Jiansong Gao,
Andrea Giachero,
Shannon F. Hoogerheide,
Ben Loer,
H. Pieter Mumm,
Nathan Nakamura,
Galen C. O'Neil,
John L. Orrell,
Elizabeth M. Scott,
Jason Stevens,
Daniel S. Swetz,
Brent A. VanDevender,
Michael Vissers,
Joel N. Ullom
Abstract:
Naturally occurring background radiation is a source of correlated decoherence events in superconducting qubits that will challenge error-correction schemes. To characterize the radiation environment in an unshielded laboratory, we performed broadband, spectroscopic measurements of background events in silicon substrates located inside a millikelvin refrigerator, an environment representative of s…
▽ More
Naturally occurring background radiation is a source of correlated decoherence events in superconducting qubits that will challenge error-correction schemes. To characterize the radiation environment in an unshielded laboratory, we performed broadband, spectroscopic measurements of background events in silicon substrates located inside a millikelvin refrigerator, an environment representative of superconducting qubit systems. We measured the background spectra in silicon substrates of two thicknesses, 0.5 mm and 1.5 mm, and obtained the average event rate and the integrated power deposition. In a 25 mm^2 area and the thinner substrate, these values are 0.023 events per second and 4.9 keV/s, counting events that deposit at least 40 keV. We find the background spectrum to be nearly featureless. Its intensity decreases by a factor of 40,000 between 100 keV and 3 MeV for silicon substrates 0.5 mm thick. We find the cryogenic measurements to be in good agreement with predictions based on measurements of the terrestrial gamma-ray flux, published models of cosmic-ray fluxes, a crude model of the cryostat, and radiation-transport simulations. No free parameters are required to predict the background spectra in the silicon substrates. The good agreement between measurements and predictions allow assessment of the relative contributions of terrestrial and cosmic background sources and their dependence on substrate thickness. Our spectroscopic measurements are performed with superconducting microresonators that transduce deposited energy to a readily detectable electrical signal. We find that gamma-ray emissions from radioisotopes are responsible for the majority of events depositing E<1.5 MeV, while nucleons among the cosmic-ray secondary particles cause most events that deposit more energy. These results suggest several paths to reducing the impact of background radiation on quantum circuits.
△ Less
Submitted 16 April, 2024;
originally announced April 2024.
-
Characterization of NbTiN films with thicknesses below 20 nm for low power kinetic inductance amplifiers
Authors:
A. Giachero,
M. R. Vissers,
J. D. Wheeler,
M. Malnou,
J. E. Austermann,
J. Hubmayr,
A. Nucciotti,
J. N. Ullom,
J. Gao
Abstract:
A quantum-limited amplification chain is a fundamental advantage for any application that may benefit from the detection of very faint signals. Reading out arrays of superconducting detectors (TESs or MKIDs), resonant cavities, or qubits, calls for large bandwidth amplifiers in addition to having the lowest possible noise. At millikelvin temperatures, Kinetic Inductance Traveling-Wave Parametric A…
▽ More
A quantum-limited amplification chain is a fundamental advantage for any application that may benefit from the detection of very faint signals. Reading out arrays of superconducting detectors (TESs or MKIDs), resonant cavities, or qubits, calls for large bandwidth amplifiers in addition to having the lowest possible noise. At millikelvin temperatures, Kinetic Inductance Traveling-Wave Parametric Amplifiers (KI-TWPAs) working in 3-wave-mixing (3WM) and fabricated from a 20 nm thick NbTiN film have shown promising noise performances, as they can operate close to the quantum limit. However, they still require fairly high pump power. Devices that would require lower pump power would be easier to implement in readout chains, could reach the quantum limit and they would be compatible with qubit readout. A possible solution for obtaining this optimal configuration is to use a thinner superconducting film. In this work we explore the properties of NbTiN films with a thickness less than 20 nm and we report the obtained experimental characterizations in terms of critical temperature, normal resistivity, and kinetic inductance. A new design for a 3WM KI-TWPA amplifier, based on these developed superconducting films, is introduced and discussed.
△ Less
Submitted 18 February, 2024;
originally announced February 2024.
-
The BLAST Observatory: A Sensitivity Study for Far-IR Balloon-borne Polarimeters
Authors:
The BLAST Observatory Collaboration,
Gabriele Coppi,
Simon Dicker,
James E. Aguirre,
Jason E. Austermann,
James A. Beall,
Susan E. Clark,
Erin G. Cox,
Mark J. Devlin,
Laura M. Fissel,
Nicholas Galitzki,
Brandon S. Hensley,
Johannes Hubmayr,
Sergio Molinari,
Federico Nati,
Giles Novak,
Eugenio Schisano,
Juan D. Soler,
Carole E. Tucker,
Joel N. Ullom,
Anna Vaskuri,
Michael R. Vissers,
Jordan D. Wheeler,
Mario Zannoni
Abstract:
Sensitive wide-field observations of polarized thermal emission from interstellar dust grains will allow astronomers to address key outstanding questions about the life cycle of matter and energy driving the formation of stars and the evolution of galaxies. Stratospheric balloon-borne telescopes can map this polarized emission at far-infrared wavelengths near the peak of the dust thermal spectrum…
▽ More
Sensitive wide-field observations of polarized thermal emission from interstellar dust grains will allow astronomers to address key outstanding questions about the life cycle of matter and energy driving the formation of stars and the evolution of galaxies. Stratospheric balloon-borne telescopes can map this polarized emission at far-infrared wavelengths near the peak of the dust thermal spectrum - wavelengths that are inaccessible from the ground. In this paper we address the sensitivity achievable by a Super Pressure Balloon (SPB) polarimetry mission, using as an example the Balloon-borne Large Aperture Submillimeter Telescope (BLAST) Observatory. By launching from Wanaka, New Zealand, BLAST Observatory can obtain a 30-day flight with excellent sky coverage - overcoming limitations of past experiments that suffered from short flight duration and/or launch sites with poor coverage of nearby star-forming regions. This proposed polarimetry mission will map large regions of the sky at sub-arcminute resolution, with simultaneous observations at 175, 250, and 350 $μm$, using a total of 8274 microwave kinetic inductance detectors. Here, we describe the scientific motivation for the BLAST Observatory, the proposed implementation, and the forecasting methods used to predict its sensitivity. We also compare our forecasted experiment sensitivity with other facilities.
△ Less
Submitted 23 May, 2024; v1 submitted 25 January, 2024;
originally announced January 2024.
-
The Atacama Cosmology Telescope: Mitigating the impact of extragalactic foregrounds for the DR6 CMB lensing analysis
Authors:
Niall MacCrann,
Blake D. Sherwin,
Frank J. Qu,
Toshiya Namikawa,
Mathew S. Madhavacheril,
Irene Abril-Cabezas,
Rui An,
Jason E. Austermann,
Nicholas Battaglia,
Elia S. Battistelli,
James A. Beall,
Boris Bolliet,
J. Richard Bond,
Hongbo Cai,
Erminia Calabrese,
William R. Coulton,
Omar Darwish,
Shannon M. Duff,
Adriaan J. Duivenvoorden,
Jo Dunkley,
Gerrit S. Farren,
Simone Ferraro,
Joseph E. Golec,
Yilun Guan,
Dongwon Han
, et al. (25 additional authors not shown)
Abstract:
We investigate the impact and mitigation of extragalactic foregrounds for the CMB lensing power spectrum analysis of Atacama Cosmology Telescope (ACT) data release 6 (DR6) data. Two independent microwave sky simulations are used to test a range of mitigation strategies. We demonstrate that finding and then subtracting point sources, finding and then subtracting models of clusters, and using a prof…
▽ More
We investigate the impact and mitigation of extragalactic foregrounds for the CMB lensing power spectrum analysis of Atacama Cosmology Telescope (ACT) data release 6 (DR6) data. Two independent microwave sky simulations are used to test a range of mitigation strategies. We demonstrate that finding and then subtracting point sources, finding and then subtracting models of clusters, and using a profile bias-hardened lensing estimator, together reduce the fractional biases to well below statistical uncertainties, with the inferred lensing amplitude, $A_{\mathrm{lens}}$, biased by less than $0.2σ$. We also show that another method where a model for the cosmic infrared background (CIB) contribution is deprojected and high frequency data from Planck is included has similar performance. Other frequency-cleaned options do not perform as well, incurring either a large noise cost, or resulting in biased recovery of the lensing spectrum. In addition to these simulation-based tests, we also present null tests performed on the ACT DR6 data which test for sensitivity of our lensing spectrum estimation to differences in foreground levels between the two ACT frequencies used, while nulling the CMB lensing signal. These tests pass whether the nulling is performed at the map or bandpower level. The CIB-deprojected measurement performed on the DR6 data is consistent with our baseline measurement, implying contamination from the CIB is unlikely to significantly bias the DR6 lensing spectrum. This collection of tests gives confidence that the ACT DR6 lensing measurements and cosmological constraints presented in companion papers to this work are robust to extragalactic foregrounds.
△ Less
Submitted 11 April, 2023;
originally announced April 2023.
-
Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier
Authors:
M. Malnou,
J. A. B. Mates,
M. R. Vissers,
L. R. Vale,
D. R. Schmidt,
D. A. Bennett,
J. Gao,
J. N. Ullom
Abstract:
We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (umux). This umux is designed to multiplex signals from arrays of low temperature detectors such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodi…
▽ More
We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (umux). This umux is designed to multiplex signals from arrays of low temperature detectors such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from $1.6$ $μΦ_0/\sqrt{\mathrm{Hz}}$ with the KITWPA off, to $0.77$ $μΦ_0/\sqrt{\mathrm{Hz}}$ with the KITWPA on. When statically biasing the umux to the maximally flux-sensitive point, the flux noise drops from $0.45$ $μΦ_0/\sqrt{\mathrm{Hz}}$ to $0.2$ $μΦ_0/\sqrt{\mathrm{Hz}}$. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the umux and detecting background radiation. The combination of umux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.
△ Less
Submitted 7 March, 2023;
originally announced March 2023.
-
G4CMP: Condensed Matter Physics Simulation Using the Geant4 Toolkit
Authors:
M. H. Kelsey,
R. Agnese,
Y. F. Alam,
I. Ataee Langroudy,
E. Azadbakht,
D. Brandt,
R. Bunker,
B. Cabrera,
Y. -Y. Chang,
H. Coombes,
R. M. Cormier,
M. D. Diamond,
E. R. Edwards,
E. Figueroa-Feliciano,
J. Gao,
P. M. Harrington,
Z. Hong,
M. Hui,
N. A. Kurinsky,
R. E. Lawrence,
B. Loer,
M. G. Masten,
E. Michaud,
E. Michielin,
J. Miller
, et al. (22 additional authors not shown)
Abstract:
G4CMP simulates phonon and charge transport in cryogenic semiconductor crystals using the Geant4 toolkit. The transport code is capable of simulating the propagation of acoustic phonons as well as electron and hole charge carriers. Processes for anisotropic phonon propagation, oblique charge-carrier propagation, and phonon emission by accelerated charge carriers are included. The simulation reprod…
▽ More
G4CMP simulates phonon and charge transport in cryogenic semiconductor crystals using the Geant4 toolkit. The transport code is capable of simulating the propagation of acoustic phonons as well as electron and hole charge carriers. Processes for anisotropic phonon propagation, oblique charge-carrier propagation, and phonon emission by accelerated charge carriers are included. The simulation reproduces theoretical predictions and experimental observations such as phonon caustics, heat-pulse propagation times, and mean charge-carrier drift velocities. In addition to presenting the physics and features supported by G4CMP, this report outlines example applications from the dark matter and quantum information science communities. These communities are applying G4CMP to model and design devices for which the energy transported by phonons and charge carriers is germane to the performance of superconducting instruments and circuits placed on silicon and germanium substrates. The G4CMP package is available to download from GitHub: github.com/kelseymh/G4CMP.
△ Less
Submitted 12 February, 2023;
originally announced February 2023.
-
A tabletop x-ray tomography instrument for nanometer-scale imaging: demonstration of the 1,000-element transition-edge sensor subarray
Authors:
Paul Szypryt,
Nathan Nakamura,
Daniel T. Becker,
Douglas A. Bennett,
Amber L. Dagel,
W. Bertrand Doriese,
Joseph W. Fowler,
Johnathon D. Gard,
J. Zachariah Harris,
Gene C. Hilton,
Jozsef Imrek,
Edward S. Jimenez,
Kurt W. Larson,
Zachary H. Levine,
John A. B. Mates,
D. McArthur,
Luis Miaja-Avila,
Kelsey M. Morgan,
Galen C. O'Neil,
Nathan J. Ortiz,
Christine G. Pappas,
Daniel R. Schmidt,
Kyle R. Thompson,
Joel N. Ullom,
Leila Vale
, et al. (6 additional authors not shown)
Abstract:
We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial resolution scanning electron microscope (SEM) with a highly efficient and pixelated TES spectrometer to reconstruct three-dimensional maps of nanoscale integrated circuits (ICs). A 240-pixel prototype spectrometer was recent…
▽ More
We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial resolution scanning electron microscope (SEM) with a highly efficient and pixelated TES spectrometer to reconstruct three-dimensional maps of nanoscale integrated circuits (ICs). A 240-pixel prototype spectrometer was recently used to reconstruct ICs at the 130 nm technology node, but to increase imaging speed to more practical levels, the detector efficiency needs to be improved. For this reason, we are building a spectrometer that will eventually contain 3,000 TES microcalorimeters read out with microwave superconducting quantum interference device (SQUID) multiplexing, and we currently have commissioned a 1,000 TES subarray. This still represents a significant improvement from the 240-pixel system and allows us to begin characterizing the full spectrometer performance. Of the 992 maximimum available readout channels, we have yielded 818 devices, representing the largest number of TES x-ray microcalorimeters simultaneously read out to date. These microcalorimeters have been optimized for pulse speed rather than purely energy resolution, and we measure a FWHM energy resolution of 14 eV at the 8.0 keV Cu K$α$ line.
△ Less
Submitted 22 December, 2022;
originally announced December 2022.
-
Nanoscale Three-Dimensional Imaging of Integrated Circuits using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer
Authors:
Nathan Nakamura,
Paul Szypryt,
Amber L. Dagel,
Bradley K. Alpert,
Douglas A. Bennett,
W. Bertrand Doriese,
Malcolm Durkin,
Joseph W. Fowler,
Dylan T. Fox,
Johnathon D. Gard,
Ryan N. Goodner,
J. Zachariah Harris,
Gene C. Hilton,
Edward S. Jimenez,
Burke L. Kernen,
Kurt W. Larson,
Zachary H. Levine,
Daniel McArthur,
Kelsey M. Morgan,
Galen C. O'Neil,
Nathan J. Ortiz,
Christine G. Pappas,
Carl D. Reintsema,
Daniel R. Schmidt,
Peter A. Schultz
, et al. (8 additional authors not shown)
Abstract:
X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but is difficult to implement due to competing requirements on X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial res…
▽ More
X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but is difficult to implement due to competing requirements on X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while changing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot in a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with high signal-to-noise. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enable nanoscale, element-specific X-ray imaging in a compact footprint. The proof-of-concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in 6 layers of a Cu-SiO2 integrated circuit, and a path towards finer resolution and enhanced imaging capabilities is discussed.
△ Less
Submitted 4 March, 2024; v1 submitted 20 December, 2022;
originally announced December 2022.
-
Design of a 3000-pixel transition-edge sensor x-ray spectrometer for microcircuit tomography
Authors:
Paul Szypryt,
Douglas A. Bennett,
William J. Boone,
Amber L. Dagel,
Gabriella Dalton,
W. Bertrand Doriese,
Joseph W. Fowler,
Edward J. Garboczi,
Johnathon D. Gard,
Gene C. Hilton,
Jozsef Imrek,
Edward S. Jimenez,
Vincent Y. Kotsubo,
Kurt Larson,
Zachary H. Levine,
John A. B. Mates,
Daniel McArthur,
Kelsey M. Morgan,
Nathan Nakamura,
Galen C. O'Neil,
Nathan J. Ortiz,
Christine G. Pappas,
Carl D. Reintsema,
Daniel R. Schmidt,
Daniel S. Swetz
, et al. (6 additional authors not shown)
Abstract:
Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development, defect analysis, and detection of unexpected structures in externally sourced chips, among other applications. Here, we report on a non-destructive, tabletop approa…
▽ More
Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development, defect analysis, and detection of unexpected structures in externally sourced chips, among other applications. Here, we report on a non-destructive, tabletop approach that addresses this imaging problem through x-ray tomography, which we uniquely realize with an instrument that combines a scanning electron microscope (SEM) with a transition-edge sensor (TES) x-ray spectrometer. Our approach uses the highly focused SEM electron beam to generate a small x-ray generation region in a carefully designed target layer that is placed over the sample being tested. With the high collection efficiency and resolving power of a TES spectrometer, we can isolate x-rays generated in the target from background and trace their paths through regions of interest in the sample layers, providing information about the various materials along the x-ray paths through their attenuation functions. We have recently demonstrated our approach using a 240 Mo/Cu bilayer TES prototype instrument on a simplified test sample containing features with sizes of $\sim$1 $μ$m. Currently, we are designing and building a 3000 Mo/Au bilayer TES spectrometer upgrade, which is expected to improve the imaging speed by factor of up to 60 through a combination of increased detector number and detector speed.
△ Less
Submitted 14 December, 2022;
originally announced December 2022.
-
A 50 mK test bench for demonstration of the readout chain of Athena/X-IFU
Authors:
Florent Castellani,
Sophie Beaumont,
François Pajot,
Gilles Roudil,
Joseph Adams,
Simon Bandler,
James Chervenak,
Christophe Daniel,
Edward V Denison,
W Bertrand Doriese,
Michel Dupieux,
Malcolm Durkin,
Hervé Geoffray,
Gene C Hilton,
David Murat,
Yann Parot,
Philippe Peille,
Damien Prêle,
Laurent Ravera,
Carl D Reintsema,
Kazuhiro Sakai,
Robert W Stevens,
Joel N Ullom,
Leila R Vale,
Nicholas Wakeham
Abstract:
The X-IFU (X-ray Integral Field Unit) onboard the large ESA mission Athena (Advanced Telescope for High ENergy Astrophysics), planned to be launched in the mid 2030s, will be a cryogenic X-ray imaging spectrometer operating at 55 mK. It will provide unprecedented spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) in the 0.2-12 keV energy range thanks to its array of TES (Tra…
▽ More
The X-IFU (X-ray Integral Field Unit) onboard the large ESA mission Athena (Advanced Telescope for High ENergy Astrophysics), planned to be launched in the mid 2030s, will be a cryogenic X-ray imaging spectrometer operating at 55 mK. It will provide unprecedented spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) in the 0.2-12 keV energy range thanks to its array of TES (Transition Edge Sensors) microcalorimeters of more than 2k pixel. The detection chain of the instrument is developed by an international collaboration: the detector array by NASA/GSFC, the cold electronics by NIST, the cold amplifier by VTT, the WFEE (Warm Front-End Electronics) by APC, the DRE (Digital Readout Electronics) by IRAP and a focal plane assembly by SRON. To assess the operation of the complete readout chain of the X-IFU, a 50 mK test bench based on a kilo-pixel array of microcalorimeters from NASA/GSFC has been developed at IRAP in collaboration with CNES. Validation of the test bench has been performed with an intermediate detection chain entirely from NIST and Goddard. Next planned activities include the integration of DRE and WFEE prototypes in order to perform an end-to-end demonstration of a complete X-IFU detection chain.
△ Less
Submitted 9 September, 2022;
originally announced September 2022.
-
The potential of microcalorimeter x-ray spectrometers for measurement of relative fluorescence-line intensities
Authors:
J. W. Fowler,
L. Miaja-Avila,
G. C. O'Neil,
J. N. Ullom,
H. Whitelock,
D. S. Swetz
Abstract:
We have previously used an array of cryogenic microcalorimeters with 4 eV energy resolution to measure emission-line profiles and energies of the characteristic L-shell x rays of four elements of the lanthanide series: praseodymium, neodymium, terbium, and holmium. We consider the power of the same data set for the estimation of the lines' relative intensities. Intensities must be corrected for de…
▽ More
We have previously used an array of cryogenic microcalorimeters with 4 eV energy resolution to measure emission-line profiles and energies of the characteristic L-shell x rays of four elements of the lanthanide series: praseodymium, neodymium, terbium, and holmium. We consider the power of the same data set for the estimation of the lines' relative intensities. Intensities must be corrected for detector efficiency and self-absorption, and we estimate uncertainties on the corrections. These data represent one of the first uses of cryogenic energy-dispersive sensors to estimate the relative intensities of x-ray fluorescence lines. They show that a future measurement of thin-film samples with microcalorimeter detectors could achieve systematic uncertainties below 1% on relative line intensities over a broad energy range.
△ Less
Submitted 16 August, 2022;
originally announced August 2022.
-
Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV
Authors:
Daikang Yan,
Joel C. Weber,
Tejas Guruswamy,
Kelsey M. Morgan,
Galen C. O'Neil,
Abigail L. Wessels,
Douglas A. Bennett,
Christine G. Pappas,
John A. Mates,
Johnathon D. Gard,
Daniel T. Becker,
Joseph W. Fowler,
Daniel S. Swetz,
Daniel R. Schmidt,
Joel N. Ullom,
Takuma Okumura,
Tadaaki Isobe,
Toshiyuki Azuma,
Shinji Okada,
Shinya Yamada,
Tadashi Hashimoto,
Orlando Quaranta,
Antonino Miceli,
Lisa M. Gades,
Umeshkumar M. Patel
, et al. (3 additional authors not shown)
Abstract:
Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard x-ray TESs to measure the absolute energies of muonic-argon ($μ$-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers…
▽ More
Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this work, we develop hard x-ray TESs to measure the absolute energies of muonic-argon ($μ$-Ar) transition lines around 44 keV and 20 keV. TESs with sidecar absorbers of different heat capacities were fabricated and characterized for their energy resolution and calibration uncertainty. We achieved ~ 1 eV absolute energy measurement accuracy at 44 keV, and < 12 eV energy resolution at 17.5 keV.
△ Less
Submitted 21 July, 2022;
originally announced July 2022.
-
Bandwidth and Aliasing in the Microwave SQUID Multiplexer
Authors:
Cyndia Yu,
Zeeshan Ahmed,
Jake A. Connors,
J. Mitch D'Ewart,
Bradley Dober,
Josef C. Frisch,
Shawn W. Henderson,
Gene C. Hilton,
Johannes Hubmayr,
Stephen E. Kuenstner,
J. A. Ben Mates,
Maximiliano Silva-Feaver,
Joel N. Ullom,
Leila R. Vale,
Dan Van Winkle,
Edward Young
Abstract:
The microwave SQUID multiplexer (umux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial availability of microwave components and warm electronics readout systems make it an attractive candidate for systems requiring large cryogenic detector counts.…
▽ More
The microwave SQUID multiplexer (umux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial availability of microwave components and warm electronics readout systems make it an attractive candidate for systems requiring large cryogenic detector counts. Since the multiplexer is considered for both bolometric and calorimetric applications across several orders of magnitude of signal frequencies, understanding the bandwidth of the device and its interaction with readout electronics is key to appropriately designing and engineering systems. Here we discuss several important factors contributing to the bandwidth properties of umux systems, including the intrinsic device bandwidth, interactions with warm electronics readout systems, and aliasing. We present simulations and measurements of umux devices coupled with SLAC Microresonator RF (SMuRF) tone-tracking electronics and discuss several implications for future experimental design.
△ Less
Submitted 17 June, 2022;
originally announced June 2022.
-
Energy calibration of nonlinear microcalorimeters with uncertainty estimates from Gaussian process regression
Authors:
J. W. Fowler,
B. K. Alpert,
G. C. O'Neil,
D. S. Swetz,
J. N. Ullom
Abstract:
The nonlinear energy response of cryogenic microcalorimeters is usually corrected through an empirical calibration. X-ray or gamma-ray emission lines of known shape and energy anchor a smooth function that generalizes the calibration data and converts detector measurements to energies. We argue that this function should be an approximating spline. The theory of Gaussian process regression makes a…
▽ More
The nonlinear energy response of cryogenic microcalorimeters is usually corrected through an empirical calibration. X-ray or gamma-ray emission lines of known shape and energy anchor a smooth function that generalizes the calibration data and converts detector measurements to energies. We argue that this function should be an approximating spline. The theory of Gaussian process regression makes a case for this functional form. It also provides an important benefit previously absent from our calibration method: a quantitative uncertainty estimate for the calibrated energies, with lower uncertainty near the best-constrained calibration points.
△ Less
Submitted 13 April, 2022;
originally announced April 2022.
-
Quantification of 242Pu with a Microcalorimeter Gamma Spectrometer
Authors:
David J. Mercer,
Ryan Winkler,
Katrina E. Koehler,
Daniel T. Becker,
Douglas A. Bennett,
Matthew H. Carpenter,
Mark P. Croce,
Krystal I. de Castro,
Eric A. Feissle,
Joseph W. Fowler,
Johnathon D. Gard,
John A. B. Mates,
Daniel G. McNeel,
Nathan J. Ortiz,
Daniel Schmidt,
Katherine A. Schreiber,
Daniel S. Swetz,
Joel N. Ullom,
Leila R. Vale,
Sophie L. Weidenbenner,
Abigail L. Wessels
Abstract:
We report measurements of the 103-keV and 159-keV gamma ray signatures of 242Pu using microcalorimetry. This is the first observation of these gamma rays in a non-destructive measurement of an unprepared sample, and so represents an important advance in nuclear material accountancy. The measurement campaign also serves as the first demonstration of a field campaign with a portable microcalorimeter…
▽ More
We report measurements of the 103-keV and 159-keV gamma ray signatures of 242Pu using microcalorimetry. This is the first observation of these gamma rays in a non-destructive measurement of an unprepared sample, and so represents an important advance in nuclear material accountancy. The measurement campaign also serves as the first demonstration of a field campaign with a portable microcalorimeter gamma-ray spectrometer. For the 103-keV gamma ray we report an improved centroid energy and emission probability.
△ Less
Submitted 8 July, 2022; v1 submitted 6 February, 2022;
originally announced February 2022.
-
Performance of a Kinetic-Inductance Traveling-Wave Parametric Amplifier at 4 Kelvin: Toward an Alternative to Semiconductor Amplifiers
Authors:
M. Malnou,
J. Aumentado,
M. R. Vissers,
J. D. Wheeler,
J. Hubmayr,
J. N. Ullom,
J. Gao
Abstract:
Most microwave readout architectures in quantum computing or sensing rely on a semiconductor amplifier at 4 K, typically a high-electron mobility transistor (HEMT). Despite its remarkable noise performance, a conventional HEMT dissipates several milliwatts of power, posing a practical challenge to scale up the number of qubits or sensors addressed in these architectures. As an alternative, we pres…
▽ More
Most microwave readout architectures in quantum computing or sensing rely on a semiconductor amplifier at 4 K, typically a high-electron mobility transistor (HEMT). Despite its remarkable noise performance, a conventional HEMT dissipates several milliwatts of power, posing a practical challenge to scale up the number of qubits or sensors addressed in these architectures. As an alternative, we present an amplification chain consisting of a kinetic-inductance traveling-wave parametric amplifier (KI-TWPA) placed at 4 K, followed by a HEMT placed at 70 K, and demonstrate a chain-added noise $T_Σ= 6.3\pm0.5$ K between 3.5 and 5.5 GHz. While, in principle, any parametric amplifier can be quantum limited even at 4 K, in practice we find the KI-TWPA's performance limited by the temperature of its inputs, and by an excess of noise $T_\mathrm{ex} = 1.9$ K. The dissipation of the KI-TWPA's rf pump constitutes the main power load at 4 K and is about one percent that of a HEMT. These combined noise and power dissipation values pave the way for the KI-TWPA's use as a replacement for semiconductor amplifiers.
△ Less
Submitted 15 October, 2021;
originally announced October 2021.
-
CCAT-prime Collaboration: Science Goals and Forecasts with Prime-Cam on the Fred Young Submillimeter Telescope
Authors:
CCAT-Prime collaboration,
M. Aravena,
J. E. Austermann,
K. Basu,
N. Battaglia,
B. Beringue,
F. Bertoldi,
F. Bigiel,
J. R. Bond,
P. C. Breysse,
C. Broughton,
R. Bustos,
S. C. Chapman,
M. Charmetant,
S. K. Choi,
D. T. Chung,
S. E. Clark,
N. F. Cothard,
A. T. Crites,
A. Dev,
K. Douglas,
C. J. Duell,
R. Dunner,
H. Ebina,
J. Erler
, et al. (62 additional authors not shown)
Abstract:
We present a detailed overview of the science goals and predictions for the Prime-Cam direct detection camera/spectrometer being constructed by the CCAT-prime collaboration for dedicated use on the Fred Young Submillimeter Telescope (FYST). The FYST is a wide-field, 6-m aperture submillimeter telescope being built (first light in mid-2024) by an international consortium of institutions led by Corn…
▽ More
We present a detailed overview of the science goals and predictions for the Prime-Cam direct detection camera/spectrometer being constructed by the CCAT-prime collaboration for dedicated use on the Fred Young Submillimeter Telescope (FYST). The FYST is a wide-field, 6-m aperture submillimeter telescope being built (first light in mid-2024) by an international consortium of institutions led by Cornell University and sited at more than 5600 meters on Cerro Chajnantor in northern Chile. Prime-Cam is one of two instruments planned for FYST and will provide unprecedented spectroscopic and broadband measurement capabilities to address important astrophysical questions ranging from Big Bang cosmology through reionization and the formation of the first galaxies to star formation within our own Milky Way galaxy. Prime-Cam on the FYST will have a map** speed that is over ten times greater than existing and near-term facilities for high-redshift science and broadband polarimetric imaging at frequencies above 300 GHz. We describe details of the science program enabled by this system and our preliminary survey strategies.
△ Less
Submitted 8 August, 2022; v1 submitted 21 July, 2021;
originally announced July 2021.
-
A high-resolution view of the filament of gas between Abell 399 and Abell 401 from the Atacama Cosmology Telescope and MUSTANG-2
Authors:
Adam D. Hincks,
Federico Radiconi,
Charles Romero,
Mathew S. Madhavacheril,
Tony Mroczkowski,
Jason E. Austermann,
Eleonora Barbavara,
Nicholas Battaglia,
Elia Battistelli,
J. Richard Bond,
Erminia Calabrese,
Paolo de Bernardis,
Mark J. Devlin,
Simon R. Dicker,
Shannon M. Duff,
Adriaan J. Duivenvoorden,
Jo Dunkley,
Rolando Dünner,
Patricio A. Gallardo,
Federica Govoni,
J. Colin Hill,
Matt Hilton,
Johannes Hubmayr,
John P. Hughes,
Luca Lamagna
, et al. (21 additional authors not shown)
Abstract:
We report a significant detection of the hot intergalactic medium in the filamentary bridge connecting the galaxy clusters Abell 399 and Abell 401. This result is enabled by a low-noise, high-resolution map of the thermal Sunyaev-Zeldovich signal from the Atacama Cosmology Telescope (ACT) and Planck satellite. The ACT data provide the $1.65'$ resolution that allows us to clearly separate the profi…
▽ More
We report a significant detection of the hot intergalactic medium in the filamentary bridge connecting the galaxy clusters Abell 399 and Abell 401. This result is enabled by a low-noise, high-resolution map of the thermal Sunyaev-Zeldovich signal from the Atacama Cosmology Telescope (ACT) and Planck satellite. The ACT data provide the $1.65'$ resolution that allows us to clearly separate the profiles of the clusters, whose centres are separated by $37'$, from the gas associated with the filament. A model that fits for only the two clusters is ruled out compared to one that includes a bridge component at $>5σ$. Using a gas temperature determined from Suzaku X-ray data, we infer a total mass of $(3.3\pm0.7)\times10^{14}\,\mathrm{M}_{\odot}$ associated with the filament, comprising about $8\%$ of the entire Abell 399-Abell 401 system. We fit two phenomenological models to the filamentary structure; the favoured model has a width transverse to the axis joining the clusters of ${\sim}1.9\,\mathrm{Mpc}$. When combined with the Suzaku data, we find a gas density of $(0.88\pm0.24)\times10^{-4}\,\mathrm{cm}^{-3}$, considerably lower than previously reported. We show that this can be fully explained by a geometry in which the axis joining Abell 399 and Abell 401 has a large component along the line of sight, such that the distance between the clusters is significantly greater than the $3.2\,\mathrm{Mpc}$ projected separation on the plane of the sky. Finally, we present initial results from higher resolution ($12.7"$ effective) imaging of the bridge with the MUSTANG-2 receiver on the Green Bank Telescope.
△ Less
Submitted 26 November, 2021; v1 submitted 9 July, 2021;
originally announced July 2021.
-
The Simons Observatory microwave SQUID multiplexing detector module design
Authors:
Heather McCarrick,
Erin Healy,
Zeeshan Ahmed,
Kam Arnold,
Zachary Atkins,
Jason E. Austermann,
Tanay Bhandarkar,
Jim A. Beall,
Sarah Marie Bruno,
Steve K. Choi,
Jake Connors,
Nicholas F. Cothard,
Kevin D. Crowley,
Simon Dicker,
Bradley Dober,
Cody J. Duell,
Shannon M. Duff,
Daniel Dutcher,
Josef C. Frisch,
Nicholas Galitzki,
Megan B. Gralla,
Jon E. Gudmundsson,
Shawn W. Henderson,
Gene C. Hilton,
Shuay-Pwu Patty Ho
, et al. (34 additional authors not shown)
Abstract:
Advances in cosmic microwave background (CMB) science depend on increasing the number of sensitive detectors observing the sky. New instruments deploy large arrays of superconducting transition-edge sensor (TES) bolometers tiled densely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers and simplify their design. We present the design of…
▽ More
Advances in cosmic microwave background (CMB) science depend on increasing the number of sensitive detectors observing the sky. New instruments deploy large arrays of superconducting transition-edge sensor (TES) bolometers tiled densely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers and simplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexing factor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, which employs microwave SQUID multiplexing ($μ$mux). Simons Observatory will use 49 modules containing 60,000 bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design, presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a $95\%$ yield and a 910 multiplexing factor. The median white noise of each readout channel is 65 $\mathrm{pA/\sqrt{Hz}}$. This impacts the projected SO map** speed by $< 8\%$, which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. We discuss the measured performance in the context of SO science requirements, which are exceeded.
△ Less
Submitted 16 September, 2021; v1 submitted 28 June, 2021;
originally announced June 2021.
-
New Experimentally Observable Gamma-ray Emissions from 241Am Nuclear Decay
Authors:
Katrina E. Koehler,
Michael D. Yoho,
Matthew H. Carpenter,
Mark P. Croce,
David J. Mercer,
Chandler M. Smith,
Aidan D. Tollefson,
Duc T. Vo,
Michael A. Famiano,
Daniel T. Becker,
Johnathon D. Gard,
J. A. B. Mates,
Nathan J. Ortiz,
Joel N. Ullom,
Abigail L. Wessels,
Douglas A. Bennett,
Daniel R. Schmidt,
Daniel S. Swetz,
Leila R. Vale
Abstract:
With the high resolution of microcalorimeter detectors, previously unresolvable gamma-ray lines are now clearly resolvable. A careful measurement of 241Am decay with a large microcalorimeter array has yielded never before seen or predicted gamma lines at 207.72 +/- 0.02 keV and 208.21 +/- 0.01 keV. These have been made possible because of new microwave-multiplexing readout and improved analysis al…
▽ More
With the high resolution of microcalorimeter detectors, previously unresolvable gamma-ray lines are now clearly resolvable. A careful measurement of 241Am decay with a large microcalorimeter array has yielded never before seen or predicted gamma lines at 207.72 +/- 0.02 keV and 208.21 +/- 0.01 keV. These have been made possible because of new microwave-multiplexing readout and improved analysis algorithms for microcalorimeters.
△ Less
Submitted 29 March, 2021;
originally announced March 2021.
-
First Measurements of Nuclear Detonation Debris with Decay Energy Spectroscopy
Authors:
Mark P. Croce,
Katrina E. Koehler,
Veronika Mocko,
Andrew S. Hoover,
Stosh A. Kozimor,
Daniel R. Schmidt,
Joel N. Ullom
Abstract:
We report the first isotopic composition measurements of trinitite, nuclear detonation debris from the Trinity test, using the novel forensics technique of decay energy spectroscopy (DES). DES measures the unique total decay energy (Q value) of each alpha-decaying isotope in a small radioactive sample embedded in a microcalorimeter detector. We find that DES can measure the major alpha-decaying is…
▽ More
We report the first isotopic composition measurements of trinitite, nuclear detonation debris from the Trinity test, using the novel forensics technique of decay energy spectroscopy (DES). DES measures the unique total decay energy (Q value) of each alpha-decaying isotope in a small radioactive sample embedded in a microcalorimeter detector. We find that DES can measure the major alpha-decaying isotopes in small particles of trinitite with no dissolution or chemical processing. These first measurements demonstrate the potential of DES to provide a radiometric isotopic characterization method with sensitivity and precision to complement traditional forensics techniques.
△ Less
Submitted 22 March, 2021;
originally announced March 2021.
-
The Atacama Cosmology Telescope: Summary of DR4 and DR5 Data Products and Data Access
Authors:
Maya Mallaby-Kay,
Zachary Atkins,
Simone Aiola,
Stefania Amodeo,
Jason E. Austermann,
James A. Beall,
Daniel T. Becker,
J. Richard Bond,
Erminia Calabrese,
Grace E. Chesmore,
Steve K. Choi,
Kevin T. Crowley,
Omar Darwish,
Edwawd V. Denison,
Mark J. Devlin,
Shannon M. Duff,
Adriaan J. Duivenvoorden,
Jo Dunkley,
Simone Ferraro,
Kyra Fichman,
Patricio A. Gallardo,
Joseph E. Golec,
Yilun Guan,
Dongwon Han,
Matthew Hasselfield
, et al. (35 additional authors not shown)
Abstract:
Two recent large data releases for the Atacama Cosmology Telescope (ACT), called DR4 and DR5, are available for public access. These data include temperature and polarization maps that cover nearly half the sky at arcminute resolution in three frequency bands; lensing maps and component-separated maps covering ~ 2,100 deg^2 of sky; derived power spectra and cosmological likelihoods; a catalog of o…
▽ More
Two recent large data releases for the Atacama Cosmology Telescope (ACT), called DR4 and DR5, are available for public access. These data include temperature and polarization maps that cover nearly half the sky at arcminute resolution in three frequency bands; lensing maps and component-separated maps covering ~ 2,100 deg^2 of sky; derived power spectra and cosmological likelihoods; a catalog of over 4,000 galaxy clusters; and supporting ancillary products including beam functions and masks. The data and products are described in a suite of ACT papers; here we provide a summary. In order to facilitate ease of access to these data we present a set of Jupyter IPython notebooks developed to introduce users to DR4, DR5, and the tools needed to analyze these data. The data products (excluding simulations) and the set of notebooks are publicly available on the NASA Legacy Archive for Microwave Background Data Analysis (LAMBDA); simulation products are available on the National Energy Research Scientific Computing Center (NERSC).
△ Less
Submitted 29 April, 2021; v1 submitted 4 March, 2021;
originally announced March 2021.
-
Measurement of Ac227 Impurity in Ac225 using Decay Energy Spectroscopy
Authors:
Aidan D. Tollefson,
Chandler M. Smith,
Matthew H. Carpenter,
Mark P. Croce,
Michael E. Fassbender,
Katrina E. Koehler,
Laura M. Lilley,
Ellen M. O'Brien,
Daniel R. Schmidt,
Benjamin W. Stein,
Joel N. Ullom,
Michael D. Yoho,
David J. Mercer
Abstract:
225Ac is a valuable medical radionuclide for targeted alpha therapy, but 227Ac is an undesirable byproduct of an accelerator-based synthesis method under investigation. Sufficient detector sensitivity is critical for quantifying the trace impurity of 227Ac, with the 227Ac/225Ac activity ratio predicted to be approximately 0.15% by end-of-bombardment (EOB). Superconducting transition edge sensor (T…
▽ More
225Ac is a valuable medical radionuclide for targeted alpha therapy, but 227Ac is an undesirable byproduct of an accelerator-based synthesis method under investigation. Sufficient detector sensitivity is critical for quantifying the trace impurity of 227Ac, with the 227Ac/225Ac activity ratio predicted to be approximately 0.15% by end-of-bombardment (EOB). Superconducting transition edge sensor (TES) microcalorimeters offer high resolution energy spectroscopy using the normal-to-superconducting phase transition to measure small change in temperature. By embedding 225Ac production samples in a gold foil thermally coupled to a TES microcalorimeter we can measure the decay energies of the radionuclides embedded with high resolution and efficiency. This technique, known as decay energy spectroscopy (DES), collapses several peaks from alpha decays into single Q-value peaks. In practice there are more complex factors in the interpretation of data using DES, which we will discuss herein. Using this technique we measured the EOB 227Ac impurity to be (0.142 +/- 0.005)% for a single production sample. This demonstration has shown that DES can distinguish closely related isotopic features and is a useful tool for quantitative measures.
△ Less
Submitted 3 February, 2021;
originally announced February 2021.
-
The design of the Ali CMB Polarization Telescope receiver
Authors:
Maria Salatino,
Jason E. Austermann,
Keith L. Thompson,
Peter A. R. Ade,
Xiran Bai,
James A. Beall,
Dan T. Becker,
Yifu Cai,
Zhi Chang,
Ding Chen,
Pisin Chen,
Jake Connors,
Jacques Delabrouille,
Bradley Dober,
Shannon M. Duff,
Guanhua Gao,
Shamik Ghosh,
Richard C. Givhan,
Gene C. Hilton,
Bin Hu,
Johannes Hubmayr,
Ethan D. Karpel,
Chao-Lin Kuo,
Hong Li,
Mingzhe Li
, et al. (50 additional authors not shown)
Abstract:
Ali CMB Polarization Telescope (AliCPT-1) is the first CMB degree-scale polarimeter to be deployed on the Tibetan plateau at 5,250m above sea level. AliCPT-1 is a 90/150 GHz 72 cm aperture, two-lens refracting telescope cooled down to 4 K. Alumina lenses, 800mm in diameter, image the CMB in a 33.4° field of view on a 636mm wide focal plane. The modularized focal plane consists of dichroic polariza…
▽ More
Ali CMB Polarization Telescope (AliCPT-1) is the first CMB degree-scale polarimeter to be deployed on the Tibetan plateau at 5,250m above sea level. AliCPT-1 is a 90/150 GHz 72 cm aperture, two-lens refracting telescope cooled down to 4 K. Alumina lenses, 800mm in diameter, image the CMB in a 33.4° field of view on a 636mm wide focal plane. The modularized focal plane consists of dichroic polarization-sensitive Transition-Edge Sensors (TESes). Each module includes 1,704 optically active TESes fabricated on a 150mm diameter silicon wafer. Each TES array is read out with a microwave multiplexing readout system capable of a multiplexing factor up to 2,048. Such a large multiplexing factor has allowed the practical deployment of tens of thousands of detectors, enabling the design of a receiver that can operate up to 19 TES arrays for a total of 32,376 TESes. AliCPT-1 leverages the technological advancements in the detector design from multiple generations of previously successful feedhorn-coupled polarimeters, and in the instrument design from BICEP-3, but applied on a larger scale. The cryostat receiver is currently under integration and testing. During the first deployment year, the focal plane will be populated with up to 4 TES arrays. Further TES arrays will be deployed in the following years, fully populating the focal plane with 19 arrays on the fourth deployment year. Here we present the AliCPT-1 receiver design, and how the design has been optimized to meet the experimental requirements.
△ Less
Submitted 23 January, 2021;
originally announced January 2021.
-
The Atacama Cosmology Telescope: Detection of the Pairwise Kinematic Sunyaev-Zel'dovich Effect with SDSS DR15 Galaxies
Authors:
Victoria Calafut,
Patricio A. Gallardo,
Eve M. Vavagiakis,
Stefania Amodeo,
Simone Aiola,
Jason E. Austermann,
Nicholas Battaglia,
Elia S. Battistelli,
James A. Beall,
Rachel Bean,
J. Richard Bond,
Erminia Calabrese,
Steve K. Choi,
Nicholas F. Cothard,
Mark J. Devlin,
Cody J. Duell,
S. M. Duff,
Adriaan J. Duivenvoorden,
Jo Dunkley,
Rolando Dunner,
Simone Ferraro,
Yilun Guan,
J. Colin Hill,
Matt Hilton,
Renee Hlozek
, et al. (27 additional authors not shown)
Abstract:
We present a 5.4$σ$ detection of the pairwise kinematic Sunyaev-Zel'dovich (kSZ) effect using Atacama Cosmology Telescope (ACT) and $\it{Planck}$ CMB observations in combination with Luminous Red Galaxy samples from the Sloan Digital Sky Survey (SDSS) DR15 catalog. Results are obtained using three ACT CMB maps: co-added 150 GHz and 98 GHz maps, combining observations from 2008-2018 (ACT DR5), whic…
▽ More
We present a 5.4$σ$ detection of the pairwise kinematic Sunyaev-Zel'dovich (kSZ) effect using Atacama Cosmology Telescope (ACT) and $\it{Planck}$ CMB observations in combination with Luminous Red Galaxy samples from the Sloan Digital Sky Survey (SDSS) DR15 catalog. Results are obtained using three ACT CMB maps: co-added 150 GHz and 98 GHz maps, combining observations from 2008-2018 (ACT DR5), which overlap with SDSS DR15 over 3,700 sq. deg., and a component-separated map using night-time only observations from 2014-2015 (ACT DR4), overlap** with SDSS DR15 over 2,089 sq. deg. Comparisons of the results from these three maps provide consistency checks in relation to potential frequency-dependent foreground contamination. A total of 343,647 galaxies are used as tracers to identify and locate galaxy groups and clusters from which the kSZ signal is extracted using aperture photometry. We consider the impact of various aperture photometry assumptions and covariance estimation methods on the signal extraction. Theoretical predictions of the pairwise velocities are used to obtain best-fit, mass-averaged, optical depth estimates for each of five luminosity-selected tracer samples. A comparison of the kSZ-derived optical depth measurements obtained here to those derived from the thermal SZ effect for the same sample is presented in a companion paper.
△ Less
Submitted 24 August, 2021; v1 submitted 20 January, 2021;
originally announced January 2021.
-
The Atacama Cosmology Telescope: Probing the Baryon Content of SDSS DR15 Galaxies with the Thermal and Kinematic Sunyaev-Zel'dovich Effects
Authors:
Eve M. Vavagiakis,
Patricio A. Gallardo,
Victoria Calafut,
Stefania Amodeo,
Simone Aiola,
Jason E. Austermann,
Nicholas Battaglia,
Elia S. Battistelli,
James A. Beall,
Rachel Bean,
J. Richard Bond,
Erminia Calabrese,
Steve K. Choi,
Nicholas F. Cothard,
Mark J. Devlin,
Cody J. Duell,
S. M. Duff,
Adriaan J. Duivenvoorden,
Jo Dunkley,
Rolando Dunner,
Simone Ferraro,
Yilun Guan,
J. Colin Hill,
Matt Hilton,
Renee Hlozek
, et al. (27 additional authors not shown)
Abstract:
We present high signal-to-noise measurements (up to 12$σ$) of the average thermal Sunyaev Zel'dovich (tSZ) effect from optically selected galaxy groups and clusters and estimate their baryon content within a 2.1$^\prime$ radius aperture. Sources from the Sloan Digital Sky Survey (SDSS) Baryon Oscillation Spectroscopic Survey (BOSS) DR15 catalog overlap with 3,700 sq. deg. of sky observed by the At…
▽ More
We present high signal-to-noise measurements (up to 12$σ$) of the average thermal Sunyaev Zel'dovich (tSZ) effect from optically selected galaxy groups and clusters and estimate their baryon content within a 2.1$^\prime$ radius aperture. Sources from the Sloan Digital Sky Survey (SDSS) Baryon Oscillation Spectroscopic Survey (BOSS) DR15 catalog overlap with 3,700 sq. deg. of sky observed by the Atacama Cosmology Telescope (ACT) from 2008 to 2018 at 150 and 98 GHz (ACT DR5), and 2,089 sq. deg. of internal linear combination component-separated maps combining ACT and $\it{Planck}$ data (ACT DR4). The corresponding optical depths, $\barτ$, which depend on the baryon content of the halos, are estimated using results from cosmological hydrodynamic simulations assuming an AGN feedback radiative cooling model. We estimate the mean mass of the halos in multiple luminosity bins, and compare the tSZ-based $\barτ$ estimates to theoretical predictions of the baryon content for a Navarro-Frenk-White profile. We do the same for $\barτ$ estimates extracted from fits to pairwise baryon momentum measurements of the kinematic Sunyaev-Zel'dovich effect (kSZ) for the same data set obtained in a companion paper. We find that the $\barτ$ estimates from the tSZ measurements in this work and the kSZ measurements in the companion paper agree within $1σ$ for two out of the three disjoint luminosity bins studied, while they differ by 2-3$σ$ in the highest luminosity bin. The optical depth estimates account for one third to all of the theoretically predicted baryon content in the halos across luminosity bins. Potential systematic uncertainties are discussed. The tSZ and kSZ measurements provide a step towards empirical Compton-$\bar{y}$-$\barτ$ relationships to provide new tests of cluster formation and evolution models.
△ Less
Submitted 24 August, 2021; v1 submitted 20 January, 2021;
originally announced January 2021.
-
In situ Performance of the Low Frequency Arrayfor Advanced ACTPol
Authors:
Yaqiong Li,
Jason E. Austermann,
James A. Beall,
Sarah Marie Bruno,
Steve K. Choi,
Nicholas F. Cothard,
Kevin T. Crowley,
Shannon M. Duff,
Shuay-Pwu Patty Ho,
Joseph E. Golec,
Gene C. Hilton,
Matthew Hasselfield,
Johannes Hubmay,
Brian J. Koopman,
Marius Lungu,
Jeff McMahon,
Michael D. Niemack,
LymanA. Page,
Maria Salatino,
Sara M. Simon,
Suzanne T. Staggs,
Jason R. Stevens,
Joel N. Ullom,
Eve M. Vavagiakis,
Yuhan Wang
, et al. (2 additional authors not shown)
Abstract:
The Advanced Atacama Cosmology Telescope Polarimeter (AdvACT) \cite{thornton} is an upgrade for the Atacama Cosmology Telescope using Transition Edge Sensor (TES) detector arrays to measure cosmic microwave background (CMB) temperature and polarization anisotropies in multiple frequencies. The low frequency (LF) array was deployed early 2020. It consists of 292 TES bolometers observing in two band…
▽ More
The Advanced Atacama Cosmology Telescope Polarimeter (AdvACT) \cite{thornton} is an upgrade for the Atacama Cosmology Telescope using Transition Edge Sensor (TES) detector arrays to measure cosmic microwave background (CMB) temperature and polarization anisotropies in multiple frequencies. The low frequency (LF) array was deployed early 2020. It consists of 292 TES bolometers observing in two bands centered at 27 GHz and 39 GHz. At these frequencies, it is sensitive to synchrotron radiation from our galaxy as well as to the CMB, and complements the AdvACT arrays operating at 90, 150 and 230 GHz. We present the initial LF array on-site characterization, including the time constant, optical efficiency and array sensitivity.
△ Less
Submitted 12 January, 2021; v1 submitted 7 January, 2021;
originally announced January 2021.
-
Progress in the development of TES microcalorimeter detectors suitable for neutrino mass measurement
Authors:
A. Giachero,
B. Alpert,
D. T. Becker,
D. A. Bennett,
M. Borghesi,
M. De Gerone,
M. Faverzani,
M. Fedkevych,
E. Ferri,
G. Gallucci,
J. D. Gard,
F. Gatti,
G. C. Hilton,
J. A. B. Mates,
A. Nucciotti,
G. Pessina,
A. Puiu,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
L. R. Vale
Abstract:
The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final configuration, HOLMES will deploy 1000 detectors of low-temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Tran…
▽ More
The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutrino mass with a sensitivity below 2 eV. In its final configuration, HOLMES will deploy 1000 detectors of low-temperature microcalorimeters with implanted 163Ho nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Transition Edge Sensors) on SiNx membrane with gold absorbers. Considering the large number of pixels and an event rate of about 300 Hz/pixel, a large multiplexing factor and a large bandwidth are needed. To fulfill this requirement, HOLMES will exploit recent advances in microwave multiplexing. In this contribution, we present the status of the activities in development, the performances of the developed microwave-multiplexed readout system, and the results obtained with the detectors specifically designed for HOLMES in terms of noise, time, and energy resolutions
△ Less
Submitted 7 January, 2021;
originally announced January 2021.
-
Absolute energies and emission line shapes of the L x-ray transitions of lanthanide metals
Authors:
Joseph W. Fowler,
Galen C. O'Neil,
Bradley K. Alpert,
Douglas A. Bennett,
Ed V. Denison,
W. B. Doriese,
Gene C. Hilton,
Lawrence T. Hudson,
Young-Il Joe,
Kelsey M. Morgan,
Daniel R. Schmidt,
Daniel S. Swetz,
Csilla I. Szabo,
Joel N. Ullom
Abstract:
We use an array of transition-edge sensors, cryogenic microcalorimeters with 4 eV energy resolution, to measure L x-ray emission-line profiles of four elements of the lanthanide series: praseodymium, neodymium, terbium, and holmium. The spectrometer also surveys numerous x-ray standards in order to establish an absolute-energy calibration traceable to the International System of Units for the ener…
▽ More
We use an array of transition-edge sensors, cryogenic microcalorimeters with 4 eV energy resolution, to measure L x-ray emission-line profiles of four elements of the lanthanide series: praseodymium, neodymium, terbium, and holmium. The spectrometer also surveys numerous x-ray standards in order to establish an absolute-energy calibration traceable to the International System of Units for the energy range 4 keV to 10 keV. The new results include emission line profiles for 97 lines, each expressed as a sum of one or more Voigt functions; improved absolute energy uncertainty on 71 of these lines relative to existing reference data; a median uncertainty on the peak energy of 0.24 eV, four to ten times better than the median of prior work; and 6 lines that lack any measured values in existing reference tables. The 97 lines comprise nearly all of the most intense L lines from these elements under broad-band x-ray excitation. The work improves on previous measurements made with a similar cryogenic spectrometer by the use of sensors with better linearity in the absorbed energy and a gold x-ray absorbing layer that has a Gaussian energy-response function. It also employs a novel sample holder that enables rapid switching between science targets and calibration targets with excellent gain balancing. Most of the results for peak energy values shown here should be considered as replacements for the currently tabulated standard reference values, while the line shapes given here represent a significant expansion of the scope of available reference data.
△ Less
Submitted 30 November, 2020;
originally announced December 2020.
-
Sub-Kelvin Thermometer for On-Chip Measurements of Microwave Devices Utilizing Two-Level Systems in Superconducting Microresonators
Authors:
J. Wheeler,
M. R. Vissers,
M. Malnou,
J. Hubmayr,
J. N. Ullom,
J. Gao
Abstract:
We present a superconducting microresonator thermometer based on two-level systems (TLS) that is drop-in compatible with cryogenic microwave systems. The operational temperature range is 50-1000~mK (which may be extended to 5~mK), and the sensitivity (50-75~$μ$K/$\sqrt{\mathrm{Hz}}$) is relatively uniform across this range. The miniature footprint that conveniently attaches to the feedline of a cr…
▽ More
We present a superconducting microresonator thermometer based on two-level systems (TLS) that is drop-in compatible with cryogenic microwave systems. The operational temperature range is 50-1000~mK (which may be extended to 5~mK), and the sensitivity (50-75~$μ$K/$\sqrt{\mathrm{Hz}}$) is relatively uniform across this range. The miniature footprint that conveniently attaches to the feedline of a cryogenic microwave device facilitates the measurement of on-chip device temperature and requires no additional thermometry wiring or readout electronics. We demonstrate the practical use of these TLS thermometers to investigate static and transient chip heating in a kinetic inductance traveling-wave parametric amplifier operated with a strong pump tone. TLS thermometry may find broad application in cryogenic microwave devices such as superconducting qubits and detectors.
△ Less
Submitted 13 November, 2020;
originally announced November 2020.
-
A Microwave SQUID Multiplexer Optimized for Bolometric Applications
Authors:
B. Dober,
Z. Ahmed,
K. Arnold,
D. T. Becker,
D. A. Bennett,
J. A. Connors,
A. Cukierman,
J. M. D'Ewart,
S. M. Duff,
J. E. Dusatko,
J. C. Frisch,
J. D. Gard,
S. W. Henderson,
R. Herbst,
G. C. Hilton,
J. Hubmayr,
Y. Li,
J. A. B. Mates,
H. McCarrick,
C. D Reintsema,
M. Silva-Feaver,
L. Ruckman,
J. N. Ullom,
L. R. Vale,
D. D. Van Winkle
, et al. (5 additional authors not shown)
Abstract:
A microwave SQUID multiplexer ($μ$MUX) has been optimized for coupling to large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design in a 1820-channel multiplexer configuration for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4…
▽ More
A microwave SQUID multiplexer ($μ$MUX) has been optimized for coupling to large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design in a 1820-channel multiplexer configuration for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4-5 GHz. The median white-noise level is 45 pA/$\sqrt{\textrm{Hz}}$, evaluated at 2 Hz, with a 1/f knee $\leq$ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is $\leq$ 0.3%.
△ Less
Submitted 19 January, 2021; v1 submitted 15 October, 2020;
originally announced October 2020.
-
The Atacama Cosmology Telescope: A Catalog of > 4000 Sunyaev-Zel'dovich Galaxy Clusters
Authors:
M. Hilton,
C. Sifón,
S. Naess,
M. Madhavacheril,
M. Oguri,
E. Rozo,
E. Rykoff,
T. M. C. Abbott,
S. Adhikari,
M. Aguena,
S. Aiola,
S. Allam,
S. Amodeo,
A. Amon,
J. Annis,
B. Ansarinejad,
C. Aros-Bunster,
J. E. Austermann,
S. Avila,
D. Bacon,
N. Battaglia,
J. A. Beall,
D. T. Becker,
G. M. Bernstein,
E. Bertin
, et al. (124 additional authors not shown)
Abstract:
We present a catalog of 4195 optically confirmed Sunyaev-Zel'dovich (SZ) selected galaxy clusters detected with signal-to-noise > 4 in 13,211 deg$^2$ of sky surveyed by the Atacama Cosmology Telescope (ACT). Cluster candidates were selected by applying a multi-frequency matched filter to 98 and 150 GHz maps constructed from ACT observations obtained from 2008-2018, and confirmed using deep, wide-a…
▽ More
We present a catalog of 4195 optically confirmed Sunyaev-Zel'dovich (SZ) selected galaxy clusters detected with signal-to-noise > 4 in 13,211 deg$^2$ of sky surveyed by the Atacama Cosmology Telescope (ACT). Cluster candidates were selected by applying a multi-frequency matched filter to 98 and 150 GHz maps constructed from ACT observations obtained from 2008-2018, and confirmed using deep, wide-area optical surveys. The clusters span the redshift range 0.04 < z < 1.91 (median z = 0.52). The catalog contains 222 z > 1 clusters, and a total of 868 systems are new discoveries. Assuming an SZ-signal vs. mass scaling relation calibrated from X-ray observations, the sample has a 90% completeness mass limit of M500c > 3.8 x 10$^{14}$ MSun, evaluated at z = 0.5, for clusters detected at signal-to-noise ratio > 5 in maps filtered at an angular scale of 2.4'. The survey has a large overlap with deep optical weak-lensing surveys that are being used to calibrate the SZ-signal mass-scaling relation, such as the Dark Energy Survey (4566 deg$^2$), the Hyper Suprime-Cam Subaru Strategic Program (469 deg$^2$), and the Kilo Degree Survey (825 deg$^2$). We highlight some noteworthy objects in the sample, including potentially projected systems; clusters with strong lensing features; clusters with active central galaxies or star formation; and systems of multiple clusters that may be physically associated. The cluster catalog will be a useful resource for future cosmological analyses, and studying the evolution of the intracluster medium and galaxies in massive clusters over the past 10 Gyr.
△ Less
Submitted 2 December, 2020; v1 submitted 23 September, 2020;
originally announced September 2020.
-
The Atacama Cosmology Telescope: Weighing distant clusters with the most ancient light
Authors:
Mathew S. Madhavacheril,
Cristóbal Sifón,
Nicholas Battaglia,
Simone Aiola,
Stefania Amodeo,
Jason E. Austermann,
James A. Beall,
Daniel T. Becker,
J. Richard Bond,
Erminia Calabrese,
Steve K. Choi,
Edward V. Denison,
Mark J. Devlin,
Simon R. Dicker,
Shannon M. Duff,
Adriaan J. Duivenvoorden,
Jo Dunkley,
Rolando Dünner,
Simone Ferraro,
Patricio A. Gallardo,
Yilun Guan,
Dongwon Han,
J. Colin Hill,
Gene C. Hilton,
Matt Hilton
, et al. (36 additional authors not shown)
Abstract:
We use gravitational lensing of the cosmic microwave background (CMB) to measure the mass of the most distant blindly-selected sample of galaxy clusters on which a lensing measurement has been performed to date. In CMB data from the the Atacama Cosmology Telescope (ACT) and the Planck satellite, we detect the stacked lensing effect from 677 near-infrared-selected galaxy clusters from the Massive a…
▽ More
We use gravitational lensing of the cosmic microwave background (CMB) to measure the mass of the most distant blindly-selected sample of galaxy clusters on which a lensing measurement has been performed to date. In CMB data from the the Atacama Cosmology Telescope (ACT) and the Planck satellite, we detect the stacked lensing effect from 677 near-infrared-selected galaxy clusters from the Massive and Distant Clusters of WISE Survey (MaDCoWS), which have a mean redshift of $ \langle z \rangle = 1.08$. There are no current optical weak lensing measurements of clusters that match the distance and average mass of this sample. We detect the lensing signal with a significance of $4.2 σ$. We model the signal with a halo model framework to find the mean mass of the population from which these clusters are drawn. Assuming that the clusters follow Navarro-Frenk-White density profiles, we infer a mean mass of $\langle M_{500c}\rangle = \left(1.7 \pm 0.4 \right)\times10^{14}\,\mathrm{M}_\odot$. We consider systematic uncertainties from cluster redshift errors, centering errors, and the shape of the NFW profile. These are all smaller than 30% of our reported uncertainty. This work highlights the potential of CMB lensing to enable cosmological constraints from the abundance of distant clusters populating ever larger volumes of the observable Universe, beyond the capabilities of optical weak lensing measurements.
△ Less
Submitted 1 November, 2020; v1 submitted 16 September, 2020;
originally announced September 2020.
-
The Atacama Cosmology Telescope: Modeling the Gas Thermodynamics in BOSS CMASS galaxies from Kinematic and Thermal Sunyaev-Zel'dovich Measurements
Authors:
Stefania Amodeo,
Nicholas Battaglia,
Emmanuel Schaan,
Simone Ferraro,
Emily Moser,
Simone Aiola,
Jason E. Austermann,
James A. Beall,
Rachel Bean,
Daniel T. Becker,
Richard J. Bond,
Erminia Calabrese,
Victoria Calafut,
Steve K. Choi,
Edward V. Denison,
Mark Devlin,
Shannon M. Duff,
Adriaan J. Duivenvoorden,
Jo Dunkley,
Rolando Dünner,
Patricio A. Gallardo,
Kirsten R. Hall,
Dongwon Han,
J. Colin Hill,
Gene C. Hilton
, et al. (30 additional authors not shown)
Abstract:
The thermal and kinematic Sunyaev-Zel'dovich effects (tSZ, kSZ) probe the thermodynamic properties of the circumgalactic and intracluster medium (CGM and ICM) of galaxies, groups, and clusters, since they are proportional, respectively, to the integrated electron pressure and momentum along the line-of-sight. We present constraints on the gas thermodynamics of CMASS galaxies in the Baryon Oscillat…
▽ More
The thermal and kinematic Sunyaev-Zel'dovich effects (tSZ, kSZ) probe the thermodynamic properties of the circumgalactic and intracluster medium (CGM and ICM) of galaxies, groups, and clusters, since they are proportional, respectively, to the integrated electron pressure and momentum along the line-of-sight. We present constraints on the gas thermodynamics of CMASS galaxies in the Baryon Oscillation Spectroscopic Survey (BOSS) using new measurements of the kSZ and tSZ signals obtained in a companion paper. Combining kSZ and tSZ measurements, we measure within our model the amplitude of energy injection $εM_\star c^2$, where $M_\star$ is the stellar mass, to be $ε=(40\pm9)\times10^{-6}$, and the amplitude of the non-thermal pressure profile to be $α_{\rm Nth}<0.2$ (2$σ$), indicating that less than 20% of the total pressure within the virial radius is due to a non-thermal component. We estimate the effects of including baryons in the modeling of weak-lensing galaxy cross-correlation measurements using the best-fit density profile from the kSZ measurement. Our estimate reduces the difference between the original theoretical model and the weak-lensing galaxy cross-correlation measurements in arXiv:1611.08606 by half but does not fully reconcile it. Comparing the tSZ measurements to cosmological simulations, we find that simulations underestimate the CGM pressure at large radii while they fare better in comparison with the kSZ measurements. This suggests that the energy injected via feedback models in the simulations that we compared against does not sufficiently heat the gas at these radii. We do not find significant disagreement at smaller radii. These measurements provide novel tests of current and future simulations. This work demonstrates the power of joint, high signal-to-noise kSZ and tSZ observations, upon which future cross-correlation studies will improve.
△ Less
Submitted 9 February, 2023; v1 submitted 11 September, 2020;
originally announced September 2020.
-
The Atacama Cosmology Telescope: Combined kinematic and thermal Sunyaev-Zel'dovich measurements from BOSS CMASS and LOWZ halos
Authors:
Emmanuel Schaan,
Simone Ferraro,
Stefania Amodeo,
Nick Battaglia,
Simone Aiola,
Jason E. Austermann,
James A. Beall,
Rachel Bean,
Daniel T. Becker,
Richard J. Bond,
Erminia Calabrese,
Victoria Calafut,
Steve K. Choi,
Edward V. Denison,
Mark J. Devlin,
Shannon M. Duff,
Adriaan J. Duivenvoorden,
Jo Dunkley,
Rolando Dünner,
Patricio A. Gallardo,
Yilun Guan,
Dongwon Han,
J. Colin Hill,
Gene C. Hilton,
Matt Hilton
, et al. (33 additional authors not shown)
Abstract:
The scattering of cosmic microwave background (CMB) photons off the free-electron gas in galaxies and clusters leaves detectable imprints on high resolution CMB maps: the thermal and kinematic Sunyaev-Zel'dovich effects (tSZ and kSZ respectively). We use combined microwave maps from the Atacama Cosmology Telescope (ACT) DR5 and Planck in combination with the CMASS and LOWZ galaxy catalogs from the…
▽ More
The scattering of cosmic microwave background (CMB) photons off the free-electron gas in galaxies and clusters leaves detectable imprints on high resolution CMB maps: the thermal and kinematic Sunyaev-Zel'dovich effects (tSZ and kSZ respectively). We use combined microwave maps from the Atacama Cosmology Telescope (ACT) DR5 and Planck in combination with the CMASS and LOWZ galaxy catalogs from the Baryon Oscillation Spectroscopic Survey (BOSS DR10 and DR12), to study the gas associated with these galaxy groups. Using individual reconstructed velocities, we perform a stacking analysis and reject the no-kSZ hypothesis at 6.5$σ$, the highest significance to date. This directly translates into a measurement of the electron number density profile, and thus of the gas density profile. Despite the limited signal to noise, the measurement shows at high significance that the gas density profile is more extended than the dark matter density profile, for any reasonable baryon abundance (formally $>90σ$ for the cosmic baryon abundance). We simultaneously measure the tSZ signal, i.e. the electron thermal pressure profile of the same CMASS objects, and reject the no-tSZ hypothesis at 10$σ$. We combine tSZ and kSZ measurements to estimate the electron temperature to 20% precision in several aperture bins, and find it comparable to the virial temperature. In a companion paper, we analyze these measurements to constrain the gas thermodynamics and the properties of feedback inside galaxy groups. We present the corresponding LOWZ measurements in this paper, ruling out a null kSZ (tSZ) signal at 2.9 (13.9)$σ$, and leave their interpretation to future work. Our stacking software ThumbStack is publicly available at https://github.com/EmmanuelSchaan/ThumbStack and directly applicable to future Simons Observatory and CMB-S4 data.
△ Less
Submitted 16 February, 2021; v1 submitted 11 September, 2020;
originally announced September 2020.
-
Probing galaxy evolution in massive clusters using ACT and DES: splashback as a cosmic clock
Authors:
Susmita Adhikari,
Tae-hyeon Shin,
Bhuvnesh Jain,
Matt Hilton,
Eric Baxter,
Chihway Chang,
Risa H. Wechsler,
Nick Battaglia,
J. Richard Bond,
Sebastian Bocquet,
Joseph DeRose,
Steve K. Choi,
Mark Devlin,
Jo Dunkley,
August E. Evrard,
Simone Ferraro,
J. Colin Hill,
John P. Hughes,
Patricio A. Gallardo,
Martine Lokken,
Amanda MacInnis,
Jeffrey McMahon,
Mathew S. Madhavacheril,
Frederico Nati,
Laura B. Newburgh
, et al. (91 additional authors not shown)
Abstract:
We measure the projected number density profiles of galaxies and the splashback feature in clusters selected by the Sunyaev--Zeldovich (SZ) effect from the Advanced Atacama Cosmology Telescope (AdvACT) survey using galaxies observed by the Dark Energy Survey (DES). The splashback radius for the complete galaxy sample is consistent with theoretical measurements from CDM-only simulations, and is loc…
▽ More
We measure the projected number density profiles of galaxies and the splashback feature in clusters selected by the Sunyaev--Zeldovich (SZ) effect from the Advanced Atacama Cosmology Telescope (AdvACT) survey using galaxies observed by the Dark Energy Survey (DES). The splashback radius for the complete galaxy sample is consistent with theoretical measurements from CDM-only simulations, and is located at $2.4^{+0.3}_{-0.4}$ Mpc $h^{-1}$. We split the sample based on galaxy color and find significant differences in the profile shapes. Red galaxies and those in the green valley show a splashback-like minimum in their slope profile consistent with theoretical predictions, while the bluest galaxies show a weak feature that appears at a smaller radius. We develop a map** of galaxies to subhalos in $N$-body simulations by splitting subhalos based on infall time onto the cluster halos. We find that the location of the steepest slope and differences in the shapes of the profiles can be mapped to differences in the average time of infall of galaxies of different colors. The minima of the slope in the galaxy profiles trace a discontinuity in the phase space of dark matter halos. By relating spatial profiles to infall time for galaxies of different colours, we can use splashback as a clock to understand galaxy quenching. We find that red galaxies have on average been in their clusters for over $3.2 ~\rm Gyrs$, green galaxies about $2.2 ~\rm Gyrs$, while blue galaxies have been accreted most recently and have not reached apocenter. Using the information from the complete radial profiles, we fit a simple quenching model and find that the onset of galaxy quenching in clusters occurs after a delay of about a gigayear, and that galaxies quench rapidly thereafter with an exponential timescale of $0.6$ Gyr.
△ Less
Submitted 26 August, 2020;
originally announced August 2020.
-
The Atacama Cosmology Telescope: DR5 maps of 18,000 square degrees of the microwave sky from ACT 2008-2018 data
Authors:
Sigurd Naess,
Simone Aiola,
Jason E. Austermann,
Nick Battaglia,
James A. Beall,
Daniel T. Becker,
Richard J. Bond,
Erminia Calabrese,
Steve K. Choi,
Nicholas F. Cothard,
Kevin T. Crowley,
Omar Darwish,
Rahul Datta,
Edward V. Denison,
Mark Devlin,
Cody J. Duell,
Shannon M. Duff,
Adriaan J. Duivenvoorden,
Jo Dunkley,
Rolando Dünner,
Anna E. Fox,
Patricio A. Gallardo,
Mark Halpern,
Dongwon Han,
Matthew Hasselfield
, et al. (37 additional authors not shown)
Abstract:
This paper presents a maximum-likelihood algorithm for combining sky maps with disparate sky coverage, angular resolution and spatially varying anisotropic noise into a single map of the sky. We use this to merge hundreds of individual maps covering the 2008-2018 ACT observing seasons, resulting in by far the deepest ACT maps released so far. We also combine the maps with the full Planck maps, res…
▽ More
This paper presents a maximum-likelihood algorithm for combining sky maps with disparate sky coverage, angular resolution and spatially varying anisotropic noise into a single map of the sky. We use this to merge hundreds of individual maps covering the 2008-2018 ACT observing seasons, resulting in by far the deepest ACT maps released so far. We also combine the maps with the full Planck maps, resulting in maps that have the best features of both Planck and ACT: Planck's nearly white noise on intermediate and large angular scales and ACT's high-resolution and sensitivity on small angular scales. The maps cover over 18,000 square degrees, nearly half the full sky, at 100, 150 and 220 GHz. They reveal 4,000 optically-confirmed clusters through the Sunyaev Zel'dovich effect (SZ) and 18,500 point source candidates at $> 5σ$, the largest single collection of SZ clusters and millimeter wave sources to date. The multi-frequency maps provide millimeter images of nearby galaxies and individual Milky Way nebulae, and even clear detections of several nearby stars. Other anticipated uses of these maps include, for example, thermal SZ and kinematic SZ cluster stacking, CMB cluster lensing and galactic dust science. The method itself has negligible bias. However, due to the preliminary nature of some of the component data sets, we caution that these maps should not be used for precision cosmological analysis. The maps are part of ACT DR5, and are available on LAMBDA at https://lambda.gsfc.nasa.gov/product/act/actpol_prod_table.cfm. There is also a web atlas at https://phy-act1.princeton.edu/public/snaess/actpol/dr5/atlas.
△ Less
Submitted 17 February, 2021; v1 submitted 14 July, 2020;
originally announced July 2020.
-
A three-wave mixing kinetic inductance traveling-wave amplifier with near-quantum-limited noise performance
Authors:
M. Malnou,
M. R. Vissers,
J. D. Wheeler,
J. Aumentado,
J. Hubmayr,
J. N. Ullom,
J. Gao
Abstract:
We present a theoretical model and experimental characterization of a microwave kinetic inductance traveling-wave amplifier (KIT), whose noise performance, measured by a shot-noise tunnel junction (SNTJ), approaches the quantum limit. Biased with a dc current, the KIT operates in a three-wave mixing fashion, thereby reducing by several orders of magnitude the power of the microwave pump tone and a…
▽ More
We present a theoretical model and experimental characterization of a microwave kinetic inductance traveling-wave amplifier (KIT), whose noise performance, measured by a shot-noise tunnel junction (SNTJ), approaches the quantum limit. Biased with a dc current, the KIT operates in a three-wave mixing fashion, thereby reducing by several orders of magnitude the power of the microwave pump tone and associated parasitic heating compared to conventional four-wave mixing KIT devices. It consists of a 50 Ohms artificial transmission line whose dispersion allows for a controlled amplification bandwidth. We measure $16.5^{+1}_{-1.3}$ dB of gain across a 2 GHz bandwidth with an input 1 dB compression power of -63 dBm, in qualitative agreement with theory. Using a theoretical framework that accounts for the SNTJ-generated noise entering both the signal and idler ports of the KIT, we measure the system-added noise of an amplification chain that integrates the KIT as the first amplifier. This system-added noise, $3.1\pm0.6$ quanta (equivalent to $0.66\pm0.15$ K) between 3.5 and 5.5 GHz, is the one that a device replacing the SNTJ in that chain would see. This KIT is therefore suitable to read large arrays of microwave kinetic inductance detectors and promising for multiplexed superconducting qubit readout.
△ Less
Submitted 2 November, 2020; v1 submitted 1 July, 2020;
originally announced July 2020.
-
Improved Plutonium and Americium Photon Branching Ratios from Microcalorimeter Gamma Spectroscopy
Authors:
Michael D. Yoho,
Katrina E. Koehler,
Daniel T. Becker,
Douglas A. Bennett,
Matthew H. Carpenter,
Mark P. Croce,
Johnathon D. Gard,
J. A. Ben Mates,
David J. Mercer,
Nathan J. Ortiz,
Daniel R. Schmidt,
Chandler M. Smith,
Daniel S. Swetz,
Aidan D. Tollefson,
Joel N. Ullom,
Leila R. Vale,
Abigail L. Wessels,
Duc T. Vo
Abstract:
Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution (~60-70eV full-width-at-h…
▽ More
Photon branching ratios are critical input data for activities such as nuclear materials protection and accounting because they allow material compositions to be extracted from measurements of gamma-ray intensities. Uncertainties in these branching ratios are often a limiting source of uncertainty in composition determination. Here, we use high statistics, high resolution (~60-70eV full-width-at-half-maximum at 100 keV) gamma-ray spectra acquired using microcalorimeter sensors to substantially reduce the uncertainties for 11 plutonium (238Pu,239Pu,241Pu) and 241Am branching ratios important for material control and accountability and nuclear forensics in the energy range of 125 keV to 208 keV. We show a reduction in uncertainty of over a factor of three for one branching ratio and a factor of 2{3 for four branching ratios.
△ Less
Submitted 22 June, 2020; v1 submitted 20 May, 2020;
originally announced May 2020.
-
A Transition-edge Sensor-based X-ray Spectrometer for the Study of Highly Charged Ions at the National Institute of Standards and Technology Electron Beam Ion Trap
Authors:
P. Szypryt,
G. C. O'Neil,
E. Takacs,
J. N. Tan,
S. W. Buechele,
A. S. Naing,
D. A. Bennett,
W. B. Doriese,
M. Durkin,
J. W. Fowler,
J. D. Gard,
G. C. Hilton,
K. M. Morgan,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
Yu. Ralchenko
Abstract:
We report on the design, commissioning, and initial measurements of a Transition-edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at the National Institute of Standards and Technology (NIST). Over the past few decades, the NIST EBIT has produced numerous studies of highly charged ions in diverse fields such as atomic physics, plasma spectroscopy, and laboratory astrophysi…
▽ More
We report on the design, commissioning, and initial measurements of a Transition-edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at the National Institute of Standards and Technology (NIST). Over the past few decades, the NIST EBIT has produced numerous studies of highly charged ions in diverse fields such as atomic physics, plasma spectroscopy, and laboratory astrophysics. The newly commissioned NIST EBIT TES Spectrometer (NETS) improves the measurement capabilities of the EBIT through a combination of high x-ray collection efficiency and resolving power. NETS utilizes 192 individual TES x-ray microcalorimeters (166/192 yield) to improve upon the collection area by a factor of ~30 over the 4-pixel neutron transmutation doped germanium-based microcalorimeter spectrometer previously used at the NIST EBIT. The NETS microcalorimeters are optimized for the x-ray energies from roughly 500 eV to 8,000 eV and achieve an energy resolution of 3.7 eV to 5.0 eV over this range, a more modest (<2X) improvement over the previous microcalorimeters. Beyond this energy range NETS can operate with various trade-offs, the most significant of which are reduced efficiency at lower energies and being limited to a subset of the pixels at higher energies. As an initial demonstration of the capabilities of NETS, we measured transitions in He-like and H-like O, Ne, and Ar as well as Ni-like W. We detail the energy calibration and data analysis techniques used to transform detector counts into x-ray spectra, a process that will be the basis for analyzing future data.
△ Less
Submitted 11 May, 2020;
originally announced May 2020.
-
On low-energy tail distortions in the detector responsefunction of x-ray microcalorimeter spectrometers
Authors:
G. C. O'Neil,
P. Szypryt,
E. Takacs,
J. N. Tan,
S. W. Buechele,
A. S. Naing,
Y. I. Joe,
D. Swetz,
D. R. Schmidt,
W. B. Doriese,
J. D. Gard,
C. D. Reintsema,
J. N. Ullom,
J. S. Villarrubia,
Yu. Ralchenko
Abstract:
We use narrow spectral lines from the x-ray spectra of various highlycharged ions to measure low-energy tail-like deviations from a Gaussian responsefunction in a microcalorimter x-ray spectrometer with Au absorbers at energiesfrom 650 eV to 3320 eV. We review the literature on low energy tails in othermicrocalorimter x-ray spectrometers and present a model that explains all thereviewed tail fract…
▽ More
We use narrow spectral lines from the x-ray spectra of various highlycharged ions to measure low-energy tail-like deviations from a Gaussian responsefunction in a microcalorimter x-ray spectrometer with Au absorbers at energiesfrom 650 eV to 3320 eV. We review the literature on low energy tails in othermicrocalorimter x-ray spectrometers and present a model that explains all thereviewed tail fraction measurements. In this model a low energy tail arises fromthe combination of electron escape and energy trap** associated with Bi x-rayabsorbers.
△ Less
Submitted 11 May, 2020;
originally announced May 2020.
-
A robust principal component analysis for outlier identification in messy microcalorimeter data
Authors:
J. W. Fowler,
B. K. Alpert,
Y. -I. Joe,
G. C. O'Neil,
D. S. Swetz,
J. N. Ullom
Abstract:
A principal component analysis (PCA) of clean microcalorimeter pulse records can be a first step beyond statistically optimal linear filtering of pulses towards a fully non-linear analysis. For PCA to be practical on spectrometers with hundreds of sensors, an automated identification of clean pulses is required. Robust forms of PCA are the subject of active research in machine learning. We examine…
▽ More
A principal component analysis (PCA) of clean microcalorimeter pulse records can be a first step beyond statistically optimal linear filtering of pulses towards a fully non-linear analysis. For PCA to be practical on spectrometers with hundreds of sensors, an automated identification of clean pulses is required. Robust forms of PCA are the subject of active research in machine learning. We examine a version known as coherence pursuit that is simple, fast, and well matched to the automatic identification of outlier records, as needed for microcalorimeter pulse analysis.
△ Less
Submitted 1 November, 2019;
originally announced November 2019.
-
Tuning Excited State Electron Transfer in Fe Tetracyano-Polypyridyl Complexes
Authors:
Kristjan Kunnus,
Lin Li,
Charles J. Titus,
Sang Jun Lee,
Marco E. Reinhard,
Sergey Koroidov,
Kasper S. Kjær,
Kiryong Hong,
Kathryn Ledbetter,
William B. Doriese,
Galen C. O'Neil,
Daniel S. Swetz,
Joel N. Ullom,
Dale Li,
Kent Irwin,
Dennis Nordlund,
Amy A. Cordones,
Kelly J. Gaffney
Abstract:
We have investigated photoinduced intramolecular electron transfer dynamics following metal-to-ligand charge-transfer (MLCT) excitation of [Fe(CN)$_4$(2,2'-bipyridine)]$^{2-}$ (1), [Fe(CN)$_4$(2,3-bis(2-pyridyl)pyrazine)]$^{2-}$ (2) and [Fe(CN)$_4$(2,2'-bipyrimidine)]$^{2-}$ (3) complexes in various solvents with static and time-resolved UV-visible absorption spectroscopy and Fe 2p3d resonant inel…
▽ More
We have investigated photoinduced intramolecular electron transfer dynamics following metal-to-ligand charge-transfer (MLCT) excitation of [Fe(CN)$_4$(2,2'-bipyridine)]$^{2-}$ (1), [Fe(CN)$_4$(2,3-bis(2-pyridyl)pyrazine)]$^{2-}$ (2) and [Fe(CN)$_4$(2,2'-bipyrimidine)]$^{2-}$ (3) complexes in various solvents with static and time-resolved UV-visible absorption spectroscopy and Fe 2p3d resonant inelastic X-ray scattering. We observe $^3$MLCT lifetimes from 180 fs to 67 ps over a wide range of MLCT energies in different solvents by utilizing the strong solvatochromism of the complexes. Intramolecular electron transfer lifetimes governing $^3$MLCT relaxation increase monotonically and (super)exponentially as the $^3$MLCT energy is decreased in 1 and 2 by changing the solvent. This behavior can be described with non-adiabatic classical Marcus electron transfer dynamics along the indirect $^3$MLCT->$^3$MC pathway, where the $^3$MC is the lowest energy metal-centered (MC) excited state. In contrast, the $^3$MLCT lifetime in 3 changes non-monotonically and exhibits a maximum. This qualitatively different behaviour results from direct electron transfer from the $^3$MLCT to the electronic ground state (GS). This pathway involves nuclear tunnelling for the high-frequency polypyridyl skeleton mode ($\hbarω$ = 1530 cm$^{-1}$), which is more displaced for 3 than for either 1 or 2, therefore making the direct pathway significantly more efficient in 3. To our knowledge, this is the first observation of an efficient $^3$MLCT->GS relaxation pathway in an Fe polypyridyl complex. Our study suggests that further extending the MLCT state lifetime requires (1) lowering the $^3$MLCT state energy with respect to the $^3$MC state and (2) suppressing the intramolecular distortion of the electron-accepting ligand in the $^3$MLCT excited state to suppress the rate of direct $^3$MLCT->GS electron transfer.
△ Less
Submitted 30 October, 2019;
originally announced October 2019.
-
Working principle and demonstrator of microwave-multiplexing for the HOLMES experiment microcalorimeters
Authors:
D. T. Becker,
D. A. Bennett,
M. Biasotti,
M. Borghesi,
V. Ceriale,
M. De Gerone,
M. Faverzani,
E. Ferri,
J. W. Fowler,
G. Gallucci,
J. D. Gard,
A. Giachero,
J. P. Hays-Wehle,
G. C. Hilton,
J. A. B Mates,
A. Nucciotti,
A. Orlando,
G. Pessina,
A. Puiu,
C. D. Reintsema,
D. R. Schmidt,
D. S. Swetz,
J. N. Ullom,
L. R Vale
Abstract:
The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to measure the end-point energy of the electron capture (EC) decay of $^{163}$Ho with a statistical sensitivity on the neutrino mass as low as $\sim 1$ eV/c$^2$. In…
▽ More
The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capable to probe such quantity. The HOLMES experiment aims to measure the end-point energy of the electron capture (EC) decay of $^{163}$Ho with a statistical sensitivity on the neutrino mass as low as $\sim 1$ eV/c$^2$. In order to acquire the large needed statistics, by kee** the pile-up contribution as low as possible, 1024 transition edge sensors (TESs) with high energy and time resolutions will be employed. Microcalorimeter and bolometer arrays based on transition edge sensor with thousands of pixels are under development for several space-based and ground-based applications, including astrophysics, nuclear and particle physics, and materials science. The common necessary challenge is to develop pratical multiplexing techniques in order to simplify the cryogenics and readout systems. Despite the various multiplexing variants which are being developed have been successful, new approaches are needed to enable scaling to larger pixel counts and faster sensors, as requested for HOLMES, reducing also the cost and complexity of readout. A very novel technique that meets all of these requirements is based on superconducting microwave resonators coupled to radio-frequency Superconducting Quantum Interference Devices, in which the the changes in the TES input current is tranduced to a change in phase of a microwave signal. In this work we introduce the basics of this technique, the design and development of the first two-channel read out system and its performances with the first TES detectors specifically designed for HOLMES. In the last part we explain how to extend this approach scaling to 1024 pixels.
△ Less
Submitted 11 October, 2019;
originally announced October 2019.
-
Demonstration of 220/280 GHz Multichroic Feedhorn-Coupled TES Polarimeter
Authors:
Samantha Walker,
Carlos E. Sierra,
Jason E. Austermann,
James A. Beall,
Daniel T. Becker,
Bradley J. Dober,
Shannon M. Duff,
Gene C. Hilton,
Johannes Hubmayr,
Jeffrey L. Van Lanen,
Jeffrey J. McMahon,
Sara M. Simon,
Joel N. Ullom,
Michael R. Vissers
Abstract:
We describe the design and measurement of feedhorn-coupled, transition-edge sensor (TES) polarimeters with two passbands centered at 220 GHz and 280 GHz, intended for observations of the cosmic microwave background. Each pixel couples polarized light in two linear polarizations by use of a planar orthomode transducer and senses power via four TES bolometers, one for each band in each linear polari…
▽ More
We describe the design and measurement of feedhorn-coupled, transition-edge sensor (TES) polarimeters with two passbands centered at 220 GHz and 280 GHz, intended for observations of the cosmic microwave background. Each pixel couples polarized light in two linear polarizations by use of a planar orthomode transducer and senses power via four TES bolometers, one for each band in each linear polarization. Previous designs of this detector architecture incorporated passbands from 27 GHz to 220 GHz; we now demonstrate this technology at frequencies up to 315 GHz. Observational passbands are defined with an on-chip diplexer, and Fourier-transform-spectrometer measurements are in excellent agreement with simulations. We find coupling from feedhorn to TES bolometer using a cryogenic, temperature-controlled thermal source. We determine the optical efficiency of our device is $η$ = 77%$\pm$6% (75%$\pm$5%) for 220 (280) GHz, relative to the designed passband shapes. Lastly, we compare two power-termination schemes commonly used in wide-bandwidth millimeter-wave polarimeters and find equal performance in terms of optical efficiency and passband shape.
△ Less
Submitted 26 December, 2019; v1 submitted 25 September, 2019;
originally announced September 2019.
-
Microwave multiplexing on the Keck Array
Authors:
Ari Cukierman,
Zeeshan Ahmed,
Shawn Henderson,
Edward Young,
Cyndia Yu,
Denis Barkats,
David Brown,
Saptarshi Chaudhuri,
James Cornelison,
John M. D'Ewart,
Marion Dierickx,
Bradley J. Dober,
John Dusatko,
Sofia Fatigoni,
Jeff P. Filippini,
Josef C. Frisch,
Gunther Haller,
Mark Halpern,
Gene C. Hilton,
Johannes Hubmayr,
Kent D. Irwin,
Kirit S. Karkare,
Ethan Karpel,
Sarah A. Kernasovskiy,
John M. Kovac
, et al. (60 additional authors not shown)
Abstract:
We describe an on-sky demonstration of a microwave-multiplexing readout system in one of the receivers of the Keck Array, a polarimetry experiment observing the cosmic microwave background at the South Pole. During the austral summer of 2018-2019, we replaced the time-division multiplexing readout system with microwave-multiplexing components including superconducting microwave resonators coupled…
▽ More
We describe an on-sky demonstration of a microwave-multiplexing readout system in one of the receivers of the Keck Array, a polarimetry experiment observing the cosmic microwave background at the South Pole. During the austral summer of 2018-2019, we replaced the time-division multiplexing readout system with microwave-multiplexing components including superconducting microwave resonators coupled to radio-frequency superconducting quantum interference devices at the sub-Kelvin focal plane, coaxial-cable plumbing and amplification between room temperature and the cold stages, and a SLAC Microresonator Radio Frequency system for the warm electronics. In the range 5-6 GHz, a single coaxial cable reads out 528 channels. The readout system is coupled to transition-edge sensors, which are in turn coupled to 150-GHz slot-dipole phased-array antennas. Observations began in April 2019, and we report here on an initial characterization of the system performance.
△ Less
Submitted 17 January, 2020; v1 submitted 3 September, 2019;
originally announced September 2019.