-
Numerical Analysis of a Highly Sensitive Surface Plasmon Resonance Sensor for SARS-CoV-2 Detection
Authors:
Syed Mohammad Ashab Uddin,
Sayeed Shafayet Chowdhury,
Ehsan Kabir
Abstract:
In this paper, we propose a surface plasmon resonance (SPR) structure based on Kretschmann configuration incorporating layers of Silicon and BaTiO$_3$ on top of Ag for real-time detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using thiol tethered DNA as a ligand. Extensive numerical analysis based on transfer matrix theory as well as finite-difference time-domain (FDTD) t…
▽ More
In this paper, we propose a surface plasmon resonance (SPR) structure based on Kretschmann configuration incorporating layers of Silicon and BaTiO$_3$ on top of Ag for real-time detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using thiol tethered DNA as a ligand. Extensive numerical analysis based on transfer matrix theory as well as finite-difference time-domain (FDTD) technique has been performed to characterize the sensor response considering sensitivity, full width at half maxima, and minimum reflection. About 7.6 times enhanced sensitivity has been obtained using the proposed architecture for SARS-CoV-2 detection, compared to the basic Kretschmann configuration. Notably, the structure provides consistent enhancement over other competitive SPR structures for both angular and wavelength interrogations with a figure-of-merit of 692.28. Additionally, we repeated simulations for various ligate-ligand pairs to assess the range of applicability and robust performance improvement has been observed. As a result, the proposed sensor design provides a suitable configuration for highly sensitive, rapid, non-invasive biosensing which can be useful if adopted in experimental sensing protocols.
△ Less
Submitted 15 August, 2020;
originally announced August 2020.
-
Optimization of Surface Plasmon Resonance Biosensor for Analysis of Lipid Molecules
Authors:
Ehsan Kabir,
Syed Mohammad Ashab Uddin,
Sayeed Shafayet Chowdhury
Abstract:
Surface Plasmon Resonance (SPR) is an important bio-sensing technique for real-time label-free detection. However, it is pivotal to optimize various parameters of the sensor configuration for efficient and highly sensitive sensing. To that effect, we focus on optimizing two different SPR structures -- the basic Kretschmann configuration and narrow groove grating. Our analysis aims to detect two di…
▽ More
Surface Plasmon Resonance (SPR) is an important bio-sensing technique for real-time label-free detection. However, it is pivotal to optimize various parameters of the sensor configuration for efficient and highly sensitive sensing. To that effect, we focus on optimizing two different SPR structures -- the basic Kretschmann configuration and narrow groove grating. Our analysis aims to detect two different types of lipids known as phospholipid and eggyolk, which are used as analyte (sensing layer) and two different types of proteins namely tryptophan and bovine serum albumin (BSA) are used as ligand (binding site). For both the configurations, we investigate all possible lipid-protein combinations to understand the effect of various parameters on sensitivity, minimum reflectivity and full width half maximum (FWHM). Lipids are the structural building block of cell membranes and mutation of these layers by virus and bacteria is one the prime reasons of many diseases in our body. Hence, improving the performance of a SPR sensor to detect very small change in lipid holds immense significance. We use finite-difference time-domain (FDTD) technique to perform quantitative analysis to get an optimized structure. We find that sensitivity increases when lipid concentration is increased and it is the highest (21.95 degree/RIU) for phospholipid and tryptophan combination when metal and lipid layer thickness are 45 nm and 30 nm respectively. However, metal layer thickness does not cause any significant variation in sensitivity, but as it increases to 50 nm, minimum reflectivity and full width half maximum (FWHM) decreases to the lowest. In case of narrow groove grating structure, broad range of wavelengths can generate SPR and the sensitivity is highest (900nm/RIU) for a configuration of 10 nm groove width and 70 nm groove height at a resonance wavelength of 1411 nm.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
-
Numerical Analysis of Sensitivity Enhancement of Surface Plasmon Resonance Biosensors Using a Mirrored Bilayer Structure
Authors:
Sayeed Shafayet Chowdhury,
Syed Mohammad Ashab Uddin
Abstract:
A mirrored bilayer structure incorporating layers of Graphene and MoS2 is proposed here for Surface Plasmon Resonance (SPR) biosensing and its performance is evaluated numerically. Starting from the basic configuration, the structure with graphene and MoS2 layers is gradually developed for enhanced performance. Reflectance is the main considered parameter for performance analysis. A theoretical fr…
▽ More
A mirrored bilayer structure incorporating layers of Graphene and MoS2 is proposed here for Surface Plasmon Resonance (SPR) biosensing and its performance is evaluated numerically. Starting from the basic configuration, the structure with graphene and MoS2 layers is gradually developed for enhanced performance. Reflectance is the main considered parameter for performance analysis. A theoretical framework based on Fresnel's equations is presented and by measuring reflectance versus angle of incidence, sensitivity is calculated from the displacement of SPR angle using finite-difference time-domain (FDTD) technique. Our numerical analysis shows that using the proposed approach, about 4.2 times enhanced sensitivity can be achieved compared to the basic Kretschmann configuration. Notably, the structure provides an enhancement for both angular and wavelength interrogations. Furthermore, simulations have been repeated for various ligate-ligand pairs and consistent enhancement has been observed which proves the robustness of the structure. So, the proposed sensor architecture clearly provides pronounced improvement in sensitivity which can be significant in various practical applications.
△ Less
Submitted 29 December, 2019;
originally announced February 2020.
-
Observation of Nanoscale Opto-Mechanical Molecular Dam**; Origin of Spectroscopic Contrast in Photo Induced Force Microscopy
Authors:
Mohammad A. Almajhadi,
Syed Mohammad Ashab Uddin,
H. Kumar Wickramasinghe
Abstract:
We experimentally investigated the contrast mechanism of infrared photoinduced force microscopy (PiFM) for recording vibrational resonances. Extensive experiments have demonstrated that spectroscopic contrast in PiFM is mediated by opto-mechanical dam** of the cantilever oscillation as the optical wavelength is scanned through optical resonance. To our knowledge, this is the first time opto-mech…
▽ More
We experimentally investigated the contrast mechanism of infrared photoinduced force microscopy (PiFM) for recording vibrational resonances. Extensive experiments have demonstrated that spectroscopic contrast in PiFM is mediated by opto-mechanical dam** of the cantilever oscillation as the optical wavelength is scanned through optical resonance. To our knowledge, this is the first time opto-mechanical dam** has been observed in the AFM. We hypothesize that this dam** force is a consequence of the dissipative interaction between the sample and the vibrating tip; the modulated light source in PiFM modulates the effective dam** constant of the 2nd eigenmode of the cantilever which in turn generate side-band signals producing the PiFM signal at the 1st eigenmode. A series of experiments have eliminated other mechanisms of contrast. By tracking the frequency shift of the PiFM signal at the 1st cantilever eigenmode as the excitation wavenumber is tuned through a mid-infrared absorption band, we showed that the near-field optical interaction is attractive. By using a vibrating piezoelectric crystal to mimic sample thermal expansion in a PiFM operating in mixing mode, we determined that the minimum thermal expansion our system can detect is 30 pm limited by system noise. We have confirmed that van der Waal mediated thermal-expansion forces have negligible effect on PiFM signals by detecting the resonant response of a 4-methylbenzenethiol mono molecular layer deposited on template-stripped gold, where thermal expansion was expected to be < 3 pm, i.e., 10 times lower than our system noise level. Finally, the basic theory for dissipative tip-sample interactions was introduced to model the photoinduced opto-mechanical dam**. Theoretical simulations are in excellent agreement with experiment.
△ Less
Submitted 5 November, 2019;
originally announced November 2019.