Showing 1–2 of 2 results for author: Twisha, M
-
Calculation of true coincidence summing correction factor for clover detector in add-back and direct mode
Authors:
Ashish Gupta,
M. Shareef,
Munmun Twisha,
Saikat Bhattacharjee,
A. Mukherjee
Abstract:
The true coincidence summing effect on the full-energy peak efficiency calibration of an unsuppressed clover HPGe detector has been studied. Standard multi-energetic and mono-energetic gamma-ray sources were used to determine the full-energy peak efficiency of the detector as a function of the gamma-ray energies at different source-to-detector distances. The true coincidence summing correction fac…
▽ More
The true coincidence summing effect on the full-energy peak efficiency calibration of an unsuppressed clover HPGe detector has been studied. Standard multi-energetic and mono-energetic gamma-ray sources were used to determine the full-energy peak efficiency of the detector as a function of the gamma-ray energies at different source-to-detector distances. The true coincidence summing correction factors for the full-energy peak efficiency of the detector has been determined, in the add-back and direct modes of the detector, using both experimental and analytical methods. Geant4 simulations were performed to obtain the full-energy peak efficiency and total efficiency of the detector for different gamma-ray energies. The simulated efficiencies were used to calculate the correction factors using the analytical method. The correction factors obtained from both analytical and experimental methods were found to be in good agreement with each other. The clover detector in add-back mode exhibits larger summing corrections compared to the direct mode for the same source-to-detector distances. For the add-back mode, the coincidence summing effect is not significant for source-to-detector distances ~ 13 cm or above, whereas, for the direct mode, measurements can be performed for source-to-detector distances ~ 5 cm or above without considering the coincidence summing effect.
△ Less
Submitted 3 September, 2023;
originally announced September 2023.
-
Calculation of true coincidence summing correction factor for a Broad Energy Germanium (BEGe) detector using standard and fabricated sources
Authors:
Ashish Gupta,
M. Shareef,
Munmun Twisha,
Saikat Bhattacharjee,
Gopal Mukherjee,
Satya Samiran Nayak,
Sansaptak Basu,
S. Dasgupta,
J. Datta,
S. Bhattacharyya,
A. Mukherjee
Abstract:
The true coincidence summing (TCS) correction factor for a Broad Energy Germanium (BEGe) detector has been calculated at far and close geometry measurement using multi-energetic radioactive $γ$-ray sources $^{60}$Co, $^{133}$Ba and $^{152}$Eu. The correction factors were calculated using experimental method and analytical method. Photopeak efficiency and total efficiency required to calculate the…
▽ More
The true coincidence summing (TCS) correction factor for a Broad Energy Germanium (BEGe) detector has been calculated at far and close geometry measurement using multi-energetic radioactive $γ$-ray sources $^{60}$Co, $^{133}$Ba and $^{152}$Eu. The correction factors were calculated using experimental method and analytical method. Photopeak efficiency and total efficiency required to calculate the correction factor were obtained using Geant4 Monte Carlo simulation code. A few standard as well as fabricated mono-energetic sources were also included in the $γ$-ray efficiency measurements. The simulated efficiencies of mono-energetic $γ$-ray sources were matched to experimental $γ$-ray efficiencies by optimizing the detector parameters. The same parameters were used to obtain the photopeak and total efficiency for $γ$-ray of our interest and coincident $γ$-ray. Analytical correction factors and experimental correction factors were found in good agreement with each other.
△ Less
Submitted 6 February, 2023;
originally announced February 2023.