Skip to main content

Showing 1–8 of 8 results for author: Turpeinen, R

.
  1. arXiv:2212.04773  [pdf, other

    physics.ins-det physics.med-ph

    Pixelated silicon detector for radiation beam profile measurements

    Authors: Joonas Tikkanen, Stefanie Kirschenmann, Nikita Kramarenko, Erik Brücken, Pirkitta Koponen, Panja Luukka, Teemu Siiskonen, Raimo Turpeinen, Jennifer Ott

    Abstract: A pixelated silicon detector, developed originally for particle physics experiments, was used for a beam profile measurement of a Co-60 irradiator in a water phantom. The beam profile was compared to a profile measured with a pinpoint ionization chamber. The differences in the pixel detector and pinpoint chamber relative profiles were within approximately 0.02, and after calculating correction fac… ▽ More

    Submitted 9 December, 2022; originally announced December 2022.

  2. Quality assessment of Cadmium Telluride as a detector material for multispectral medical imaging

    Authors: S. Kirschenmann, M. Bezak, S. Bharthuar, E. Brücken, M. Golovleva, A. Gädda, M. Kalliokoski, A. Karadzhinova-Ferrer, P. Koponen, N. Kramarenko, P. Luukka, J. Ott, J. Tikkanen, R. Turpeinen, A. Winkler

    Abstract: Cadmium Telluride (CdTe) is a high-Z material with excellent photon radiation absorption properties, making it a promising material to include in radiation detection technologies. However, the brittleness of CdTe crystals as well as their varying concentration of defects necessitate a thorough quality assessment before the complex detector processing procedure. We present our quality assessment of… ▽ More

    Submitted 26 January, 2022; originally announced January 2022.

    Comments: This is the Accepted Manuscript version of an article accepted for publication in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at https://doi.org/10.1088/1748-0221/17/01/C01070

    Journal ref: JINST 17 C01070 (2022)

  3. arXiv:2103.07944  [pdf, other

    physics.ins-det hep-ex

    Hole Misalignment and Gain Performance of Gaseous Electron Multipliers

    Authors: Erik Brücken, Jouni Heino, Timo Hildén, Matti Kalliokoski, Vladyslav Litichevskyi, Raimo Turpeinen, Dezső Varga

    Abstract: It is well known and has been shown that the gain performance of Gaseous Electron Multipliers (GEM) depends on the size of the holes. With an optical scanner it is possible to measure the dimensions of the holes, and to predict the performance of GEMs. However, the gain prediction of GEMs that are manufactured with a double mask etching technique is not straightforward. With the hole size informat… ▽ More

    Submitted 14 March, 2021; originally announced March 2021.

    Comments: 14 pages, 39 figures, submitted to Nuclear Instruments and Methods in Physics Research Section A

  4. The upgrade of the ALICE TPC with GEMs and continuous readout

    Authors: J. Adolfsson, M. Ahmed, S. Aiola, J. Alme, T. Alt, W. Amend, F. Anastasopoulos, C. Andrei, M. Angelsmark, V. Anguelov, A. Anjam, H. Appelshäuser, V. Aprodu, O. Arnold, M. Arslandok, D. Baitinger, M. Ball, G. G. Barnaföldi, E. Bartsch, P. Becht, R. Bellwied, A. Berdnikova, M. Berger, N. Bialas, P. Bialas , et al. (210 additional authors not shown)

    Abstract: The upgrade of the ALICE TPC will allow the experiment to cope with the high interaction rates foreseen for the forthcoming Run 3 and Run 4 at the CERN LHC. In this article, we describe the design of new readout chambers and front-end electronics, which are driven by the goals of the experiment. Gas Electron Multiplier (GEM) detectors arranged in stacks containing four GEMs each, and continuous re… ▽ More

    Submitted 25 March, 2021; v1 submitted 17 December, 2020; originally announced December 2020.

    Comments: 88 pages, 60 figures

    Journal ref: JINST 16 (2021) P03022

  5. Twin GEM-TPC Prototype (HGB4) Beam Test at GSI and Jyväskylä - a Development for the Super-FRS at FAIR

    Authors: F. García, R. Turpeinen, J. Äystö, T. Grahn, S. Rinta-Antila, A. Jokinen, J. Kunkel, V. Kleipa, A. Gromliuk, H. Risch, C. Caesar, C. Simons, C. J. Schmidt, A. Prochazka, J. Hoffmann, I. Rusanov, N. Kurz, H. Heggen, P. Strmen, M. Pikna, B. Sitar

    Abstract: The FAIR[1] facility is an international accelerator centre for research with ion and antiproton beams. It is being built at Darmstadt, Germany as an extension to the current GSI research institute. One major part of the facility will be the Super-FRS[2] separator, which will be include in phase one of the project construction. The NUSTAR experiments will benefit from the Super-FRS, which will d… ▽ More

    Submitted 22 November, 2017; originally announced November 2017.

    Comments: 5 pages, 8 figures

    ACM Class: F.2.2; I.2.7

    Journal ref: Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD), 2016

  6. arXiv:1704.06691  [pdf, other

    physics.ins-det hep-ex

    Optical quality assurance of GEM foils

    Authors: T. Hildén, E. Brücken, J. Heino, M. Kalliokoski, A. Karadzhinova, R. Lauhakangas, E. Tuominen, R. Turpeinen

    Abstract: An analysis software was developed for the high aspect ratio optical scanning system in the Detec- tor Laboratory of the University of Helsinki and the Helsinki Institute of Physics. The system is used e.g. in the quality assurance of the GEM-TPC detectors being developed for the beam diagnostics system of the SuperFRS at future FAIR facility. The software was tested by analyzing five CERN standar… ▽ More

    Submitted 21 April, 2017; originally announced April 2017.

    Comments: 12 pages, 29 figures

    Journal ref: Nucl.Instrum.Meth. A770 (2015) 113-122

  7. Super-FRS GEM-TPC Prototype Development Based on n-Xyter Asic for the FAIR Facility

    Authors: F. Garcia, R. Turpeinen, R. Lauhakangas, E. Tuominen, R. Janik, P. Strmen, M. Pikna, B. Sitar, B. Voss, J. Kunkel, V. Kleipa, A. Prochazka, J. Hoffmann, I. Rusanov, N. Kurz, S. Minami

    Abstract: The FAIR facility is an international accelerator centre for research with ion and antiproton beams. It is being built at Darmstadt, Germany as an extension to the current GSI research institute. One major part of the facility will be the Super-FRS separator, which will be include in phase one of the project construction. The NUSTAR experiments will benefit from the Super-FRS, which will deliver… ▽ More

    Submitted 16 December, 2016; originally announced January 2017.

  8. Twin GEM-TPC Prototype (HGB4) Beam Test at GSI - a Development for the Super-FRS at FAIR

    Authors: F. Garcia, R. Turpeinen, R. Lauhakangas, E. Tuominen, J. Heino, J. Äystö, T. Grahn, S. Rinta-Antilla, A. Jokinen, R. Janik, P. Strmen, M. Pikna, B. Sitar, B. Voss, J. Kunkel, V. Kleipa, A. Gromliuk, H. Risch, I. Kaufeld, C. Caesar, C. Simon, M. kìs, A. Prochazka, C. Nociforo, S. Pietri , et al. (8 additional authors not shown)

    Abstract: The GEM-TPC detector will be part of the standard Super-FRS detection system, as tracker detectors at several focal stations along the separator and its three branches.

    Submitted 16 December, 2016; originally announced December 2016.