-
Pixelated silicon detector for radiation beam profile measurements
Authors:
Joonas Tikkanen,
Stefanie Kirschenmann,
Nikita Kramarenko,
Erik Brücken,
Pirkitta Koponen,
Panja Luukka,
Teemu Siiskonen,
Raimo Turpeinen,
Jennifer Ott
Abstract:
A pixelated silicon detector, developed originally for particle physics experiments, was used for a beam profile measurement of a Co-60 irradiator in a water phantom. The beam profile was compared to a profile measured with a pinpoint ionization chamber. The differences in the pixel detector and pinpoint chamber relative profiles were within approximately 0.02, and after calculating correction fac…
▽ More
A pixelated silicon detector, developed originally for particle physics experiments, was used for a beam profile measurement of a Co-60 irradiator in a water phantom. The beam profile was compared to a profile measured with a pinpoint ionization chamber. The differences in the pixel detector and pinpoint chamber relative profiles were within approximately 0.02, and after calculating correction factors with Monte Carlo simulations for the pixel detector, the differences were decreased to almost less than 0.005. The detector's capability to measure pulse-height was used to record an electron pulse-height spectrum in water in the Co-60 beam, and the results agreed well with simulations.
△ Less
Submitted 9 December, 2022;
originally announced December 2022.
-
Quality assessment of Cadmium Telluride as a detector material for multispectral medical imaging
Authors:
S. Kirschenmann,
M. Bezak,
S. Bharthuar,
E. Brücken,
M. Golovleva,
A. Gädda,
M. Kalliokoski,
A. Karadzhinova-Ferrer,
P. Koponen,
N. Kramarenko,
P. Luukka,
J. Ott,
J. Tikkanen,
R. Turpeinen,
A. Winkler
Abstract:
Cadmium Telluride (CdTe) is a high-Z material with excellent photon radiation absorption properties, making it a promising material to include in radiation detection technologies. However, the brittleness of CdTe crystals as well as their varying concentration of defects necessitate a thorough quality assessment before the complex detector processing procedure. We present our quality assessment of…
▽ More
Cadmium Telluride (CdTe) is a high-Z material with excellent photon radiation absorption properties, making it a promising material to include in radiation detection technologies. However, the brittleness of CdTe crystals as well as their varying concentration of defects necessitate a thorough quality assessment before the complex detector processing procedure. We present our quality assessment of CdTe as a detector material for multispectral medical imaging, a research which is conducted as part of the Consortium Project Multispectral Photon-counting for Medical Imaging and Beam characterization (MPMIB). The aim of the project is to develop novel CdTe detectors and obtain spectrum-per-pixel information that make the distinction between different radiation types and tissues possible. To evaluate the defect density inside the crystals -- which can deteriorate the detector performance -- we employ infrared microscopy (IRM). Posterior data analysis allows us to visualise the defect distributions as 3D defect maps. Additionally, we investigate front and backside differences of the material with current-voltage (IV) measurements to determine the preferred surface for the pixelisation of the crystal, and perform test measurements with the prototypes to provide feedback for further processing. We present the different parts of our quality assessment chain and will close with first experimental results obtained with one of our prototype PC detectors in a small tomographic setup.
△ Less
Submitted 26 January, 2022;
originally announced January 2022.
-
Hole Misalignment and Gain Performance of Gaseous Electron Multipliers
Authors:
Erik Brücken,
Jouni Heino,
Timo Hildén,
Matti Kalliokoski,
Vladyslav Litichevskyi,
Raimo Turpeinen,
Dezső Varga
Abstract:
It is well known and has been shown that the gain performance of Gaseous Electron Multipliers (GEM) depends on the size of the holes. With an optical scanner it is possible to measure the dimensions of the holes, and to predict the performance of GEMs. However, the gain prediction of GEMs that are manufactured with a double mask etching technique is not straightforward. With the hole size informat…
▽ More
It is well known and has been shown that the gain performance of Gaseous Electron Multipliers (GEM) depends on the size of the holes. With an optical scanner it is possible to measure the dimensions of the holes, and to predict the performance of GEMs. However, the gain prediction of GEMs that are manufactured with a double mask etching technique is not straightforward. With the hole size information alone, it is not possible to make precise prediction of the gain. We show that the alignment of the photo-masks between the two sides of the GEM foils plays a crucial role. A misalignment of a few microns can lower the gain substantially. The study is performed by using the Helsinki high definition optical scanner for quality control of GEM foils, and this will show its true potential.
△ Less
Submitted 14 March, 2021;
originally announced March 2021.
-
The upgrade of the ALICE TPC with GEMs and continuous readout
Authors:
J. Adolfsson,
M. Ahmed,
S. Aiola,
J. Alme,
T. Alt,
W. Amend,
F. Anastasopoulos,
C. Andrei,
M. Angelsmark,
V. Anguelov,
A. Anjam,
H. Appelshäuser,
V. Aprodu,
O. Arnold,
M. Arslandok,
D. Baitinger,
M. Ball,
G. G. Barnaföldi,
E. Bartsch,
P. Becht,
R. Bellwied,
A. Berdnikova,
M. Berger,
N. Bialas,
P. Bialas
, et al. (210 additional authors not shown)
Abstract:
The upgrade of the ALICE TPC will allow the experiment to cope with the high interaction rates foreseen for the forthcoming Run 3 and Run 4 at the CERN LHC. In this article, we describe the design of new readout chambers and front-end electronics, which are driven by the goals of the experiment. Gas Electron Multiplier (GEM) detectors arranged in stacks containing four GEMs each, and continuous re…
▽ More
The upgrade of the ALICE TPC will allow the experiment to cope with the high interaction rates foreseen for the forthcoming Run 3 and Run 4 at the CERN LHC. In this article, we describe the design of new readout chambers and front-end electronics, which are driven by the goals of the experiment. Gas Electron Multiplier (GEM) detectors arranged in stacks containing four GEMs each, and continuous readout electronics based on the SAMPA chip, an ALICE development, are replacing the previous elements. The construction of these new elements, together with their associated quality control procedures, is explained in detail. Finally, the readout chamber and front-end electronics cards replacement, together with the commissioning of the detector prior to installation in the experimental cavern, are presented. After a nine-year period of R&D, construction, and assembly, the upgrade of the TPC was completed in 2020.
△ Less
Submitted 25 March, 2021; v1 submitted 17 December, 2020;
originally announced December 2020.
-
Twin GEM-TPC Prototype (HGB4) Beam Test at GSI and Jyväskylä - a Development for the Super-FRS at FAIR
Authors:
F. García,
R. Turpeinen,
J. Äystö,
T. Grahn,
S. Rinta-Antila,
A. Jokinen,
J. Kunkel,
V. Kleipa,
A. Gromliuk,
H. Risch,
C. Caesar,
C. Simons,
C. J. Schmidt,
A. Prochazka,
J. Hoffmann,
I. Rusanov,
N. Kurz,
H. Heggen,
P. Strmen,
M. Pikna,
B. Sitar
Abstract:
The FAIR[1] facility is an international accelerator centre for research with ion and antiproton beams. It is being built at Darmstadt, Germany as an extension to the current GSI research institute. One major part of the facility will be the Super-FRS[2] separator, which will be include in phase one of the project construction. The NUSTAR experiments will benefit from the Super-FRS, which will d…
▽ More
The FAIR[1] facility is an international accelerator centre for research with ion and antiproton beams. It is being built at Darmstadt, Germany as an extension to the current GSI research institute. One major part of the facility will be the Super-FRS[2] separator, which will be include in phase one of the project construction. The NUSTAR experiments will benefit from the Super-FRS, which will deliver an unprecedented range of radioactive ion beams (RIB). These experiments will use beams of different energies and characteristics in three different branches; the high-energy which utilizes the RIB at relativistic energies 300-1500 MeV/u as created in the production process, the low-energy branch aims to use beams in the range of 0-150 MeV/u whereas the ring branch will cool and store beams in the NESR ring. The main tasks for the Super-FRS beam diagnostics chambers will be for the set up and adjustment of the separator as well as to provide tracking and event-by-event particle identification. The Helsinki Institute of Physics, and the Detector Laboratory and Experimental Electronics at GSI are in a joint R&D of a GEM-TPC detector which could satisfy the requirements of such tracking detectors, in terms of tracking efficiency, space resolution, count rate capability and momenta resolution. The current prototype, which is the generation four of this type, is two GEM-TPCs in twin configuration inside the same vessel. This means that one of the GEM-TPC is flipped on the middle plane w.r.t. the other one. This chamber was tested at Jyväskylä accelerator with protons projectiles and at GSI with Uranium, fragments and Carbon beams during this year 2016.
△ Less
Submitted 22 November, 2017;
originally announced November 2017.
-
Optical quality assurance of GEM foils
Authors:
T. Hildén,
E. Brücken,
J. Heino,
M. Kalliokoski,
A. Karadzhinova,
R. Lauhakangas,
E. Tuominen,
R. Turpeinen
Abstract:
An analysis software was developed for the high aspect ratio optical scanning system in the Detec- tor Laboratory of the University of Helsinki and the Helsinki Institute of Physics. The system is used e.g. in the quality assurance of the GEM-TPC detectors being developed for the beam diagnostics system of the SuperFRS at future FAIR facility. The software was tested by analyzing five CERN standar…
▽ More
An analysis software was developed for the high aspect ratio optical scanning system in the Detec- tor Laboratory of the University of Helsinki and the Helsinki Institute of Physics. The system is used e.g. in the quality assurance of the GEM-TPC detectors being developed for the beam diagnostics system of the SuperFRS at future FAIR facility. The software was tested by analyzing five CERN standard GEM foils scanned with the optical scanning system. The measurement uncertainty of the diameter of the GEM holes and the pitch of the hole pattern was found to be 0.5 μm and 0.3 μm, respectively. The software design and the performance are discussed. The correlation between the GEM hole size distribution and the corresponding gain variation was studied by comparing them against a detailed gain map** of a foil and a set of six lower precision control measurements. It can be seen that a qualitative estimation of the behavior of the local variation in gain across the GEM foil can be made based on the measured sizes of the outer and inner holes.
△ Less
Submitted 21 April, 2017;
originally announced April 2017.
-
Super-FRS GEM-TPC Prototype Development Based on n-Xyter Asic for the FAIR Facility
Authors:
F. Garcia,
R. Turpeinen,
R. Lauhakangas,
E. Tuominen,
R. Janik,
P. Strmen,
M. Pikna,
B. Sitar,
B. Voss,
J. Kunkel,
V. Kleipa,
A. Prochazka,
J. Hoffmann,
I. Rusanov,
N. Kurz,
S. Minami
Abstract:
The FAIR facility is an international accelerator centre for research with ion and antiproton beams. It is being built at Darmstadt, Germany as an extension to the current GSI research institute. One major part of the facility will be the Super-FRS separator, which will be include in phase one of the project construction. The NUSTAR experiments will benefit from the Super-FRS, which will deliver…
▽ More
The FAIR facility is an international accelerator centre for research with ion and antiproton beams. It is being built at Darmstadt, Germany as an extension to the current GSI research institute. One major part of the facility will be the Super-FRS separator, which will be include in phase one of the project construction. The NUSTAR experiments will benefit from the Super-FRS, which will deliver an unprecedented range of radioactive ion beams (RIB). These experiments will use beams of different energies and characteristics in three different branches; the high-energy which utilizes the RIB at relativistic energies 300-1500 MeV /u as created in the production process, the low energy branch aims to use beams in the range of 0-150 MeV/u whereas the ring branch will cool and store beams in the NESR ring. The main tasks for the Super-FRS beam diagnostics chambers will be for the set up and adjustment of the separator as well as to provide tracking and event-by-event particle identification. The Helsinki Institute of Physics, the Comenius University, and the Detector Laboratory and Experimental electronics at GSI are in a joint R&D phase of a GEM-TPC detector which could satisfy the requirements of such diagnostics and tracking chambers in terms of tracking efficiency, space resolution, count rate capability and momenta resolution. The current status of the first prototype and the preliminary results from the test beam campaign S417 using the n-Xyter chips mounted on GEMEX cards will be shown.
△ Less
Submitted 16 December, 2016;
originally announced January 2017.
-
Twin GEM-TPC Prototype (HGB4) Beam Test at GSI - a Development for the Super-FRS at FAIR
Authors:
F. Garcia,
R. Turpeinen,
R. Lauhakangas,
E. Tuominen,
J. Heino,
J. Äystö,
T. Grahn,
S. Rinta-Antilla,
A. Jokinen,
R. Janik,
P. Strmen,
M. Pikna,
B. Sitar,
B. Voss,
J. Kunkel,
V. Kleipa,
A. Gromliuk,
H. Risch,
I. Kaufeld,
C. Caesar,
C. Simon,
M. kìs,
A. Prochazka,
C. Nociforo,
S. Pietri
, et al. (8 additional authors not shown)
Abstract:
The GEM-TPC detector will be part of the standard Super-FRS detection system, as tracker detectors at several focal stations along the separator and its three branches.
The GEM-TPC detector will be part of the standard Super-FRS detection system, as tracker detectors at several focal stations along the separator and its three branches.
△ Less
Submitted 16 December, 2016;
originally announced December 2016.