-
Single-exposure elemental differentiation and texture-sensitive phase-retrieval imaging with a neutron counting micro-channel plate detector
Authors:
Benedicta D. Arhatari,
David M. Paganin,
Henry Kirkwood,
Anton S. Tremsin,
Timur E. Gureyev,
Alexander M. Korsunsky,
Winfried Kockelmann,
Felix Hofmann,
Eric Huwald,
Shu-Yan Zhang,
Joe Kelleher,
Brian Abbey
Abstract:
Micro-channel plate (MCP) detectors, when used at pulsed-neutron-source instruments, offer the possibility of high spatial resolution and high contrast imaging with pixel-level spectroscopic information. Here we demonstrate the possibility of multimodal analysis including total neutron cross-section spectra measurements, quantitative material differentiation imaging and texture-sensitive in-line p…
▽ More
Micro-channel plate (MCP) detectors, when used at pulsed-neutron-source instruments, offer the possibility of high spatial resolution and high contrast imaging with pixel-level spectroscopic information. Here we demonstrate the possibility of multimodal analysis including total neutron cross-section spectra measurements, quantitative material differentiation imaging and texture-sensitive in-line phase imaging, from a single exposure using an MCP detector. This multimodal approach operates in full-field imaging mode, with the neutron transmission spectra acquired at each individual detector pixel. Due to the polychromatic nature of the beam and spectroscopic resolving capability of the detector, no energy scanning is required. Good agreement with the library reference data is demonstrated for neutron cross-section spectra measurements. Two different images corresponding to two selected energy bandwidths are used for elemental differentiation imaging. Moreover, the presence of changes in texture, i.e., preferred grain orientation, in the sample is identified from our phase-retrieval imaging results.
△ Less
Submitted 27 April, 2024; v1 submitted 8 November, 2023;
originally announced November 2023.
-
Needs, trends, and advances in scintillators for radiographic imaging and tomography
Authors:
Zhehui Wang,
Christophe Dujardin,
Matthew S. Freeman,
Amanda E. Gehring,
James F. Hunter,
Paul Lecoq,
Wei Liu,
Charles L. Melcher,
C. L. Morris,
Martin Nikl,
Ghanshyam Pilania,
Reeju Pokharel,
Daniel G. Robertson,
Daniel J. Rutstrom,
Sky K. Sjue,
Anton S. Tremsin,
S. A. Watson,
Brenden W. Wiggins,
Nicola M. Winch,
Mariya Zhuravleva
Abstract:
Scintillators are important materials for radiographic imaging and tomography (RadIT), when ionizing radiations are used to reveal internal structures of materials. Since its invention by Röntgen, RadIT now come in many modalities such as absorption-based X-ray radiography, phase contrast X-ray imaging, coherent X-ray diffractive imaging, high-energy X- and $γ-$ray radiography at above 1 MeV, X-ra…
▽ More
Scintillators are important materials for radiographic imaging and tomography (RadIT), when ionizing radiations are used to reveal internal structures of materials. Since its invention by Röntgen, RadIT now come in many modalities such as absorption-based X-ray radiography, phase contrast X-ray imaging, coherent X-ray diffractive imaging, high-energy X- and $γ-$ray radiography at above 1 MeV, X-ray computed tomography (CT), proton imaging and tomography (IT), neutron IT, positron emission tomography (PET), high-energy electron radiography, muon tomography, etc. Spatial, temporal resolution, sensitivity, and radiation hardness, among others, are common metrics for RadIT performance, which are enabled by, in addition to scintillators, advances in high-luminosity accelerators and high-power lasers, photodetectors especially CMOS pixelated sensor arrays, and lately data science. Medical imaging, nondestructive testing, nuclear safety and safeguards are traditional RadIT applications. Examples of growing or emerging applications include space, additive manufacturing, machine vision, and virtual reality or `metaverse'. Scintillator metrics such as light yield and decay time are correlated to RadIT metrics. More than 160 kinds of scintillators and applications are presented during the SCINT22 conference. New trends include inorganic and organic scintillator heterostructures, liquid phase synthesis of perovskites and $μ$m-thick films, use of multiphysics models and data science to guide scintillator development, structural innovations such as photonic crystals, nanoscintillators enhanced by the Purcell effect, novel scintillator fibers, and multilayer configurations. Opportunities exist through optimization of RadIT with reduced radiation dose, data-driven measurements, photon/particle counting and tracking methods supplementing time-integrated measurements, and multimodal RadIT.
△ Less
Submitted 20 December, 2022;
originally announced December 2022.
-
Spectroscopic Neutron Imaging for Resolving Hydrogen Dynamics Changes in Battery Electrolytes
Authors:
E. R. Carreón Ruiz,
J. Lee,
J. I. Márquez Damián,
M. Strobl,
G. Burca,
R. Woracek,
M. Cochet,
M. -O. Ebert,
L. Höltschi,
P. M. Kadletz,
A. S. Tremsin,
E. Winter,
M. Zlobinski,
L. Gubler,
P. Boillat
Abstract:
We present spectroscopic neutron imaging (SNI), a bridge between imaging and scattering techniques, for the analysis of hydrogenated molecules in lithium-ion cells. The scattering information of CHn-based organic solvents and electrolytes was mapped in two-dimensional space by investigating the wavelength-dependent property of hydrogen atoms through time-of-flight imaging. Our investigation demons…
▽ More
We present spectroscopic neutron imaging (SNI), a bridge between imaging and scattering techniques, for the analysis of hydrogenated molecules in lithium-ion cells. The scattering information of CHn-based organic solvents and electrolytes was mapped in two-dimensional space by investigating the wavelength-dependent property of hydrogen atoms through time-of-flight imaging. Our investigation demonstrates a novel approach to detect physical and chemical changes in hydrogenated liquids, which extends, but not limits, the use of SNI to relevant applications in electrochemical devices, e.g., the study of electrolytes in Li-ion batteries.
△ Less
Submitted 18 July, 2022;
originally announced July 2022.
-
Antiferromagnetic real-space configuration probed by dichroism in scattered x-ray beams with orbital angular momentum
Authors:
Margaret R. McCarter,
Ahmad I. U. Saleheen,
Arnab Singh,
Ryan Tumbleson,
Justin S. Woods,
Anton S. Tremsin,
Andreas Scholl,
Lance E. De Long,
J. Todd Hastings,
Sophie A. Morley,
Sujoy Roy
Abstract:
X-ray beams with orbital angular momentum (OAM) are a promising tool for x-ray characterization techniques. Beams with OAM have a helicity--an azimuthally varying phase--which leads to a gradient of the light field. New material properties can be probed by utilizing the helicity of an OAM beam. Here, we demonstrate a novel dichroic effect in resonant diffraction from an artificial antiferromagnet…
▽ More
X-ray beams with orbital angular momentum (OAM) are a promising tool for x-ray characterization techniques. Beams with OAM have a helicity--an azimuthally varying phase--which leads to a gradient of the light field. New material properties can be probed by utilizing the helicity of an OAM beam. Here, we demonstrate a novel dichroic effect in resonant diffraction from an artificial antiferromagnet with a topological defect. We found that the scattered OAM beam has circular dichroism at the antiferromagnetic Bragg peak whose sign is coupled to its helicity, which reveals the real-space configuration of the antiferromagnetic ground state. Thermal cycling of the artificial antiferromagnet can change the ground state, as indicated by reversal of the sign of circular dichroism. This result is one of the first demonstrations of a soft x-ray spectroscopy characterization technique utilizing the OAM of x-rays. This helicity-dependent circular dichroism exemplifies the potential to utilize OAM beams to probe matter in a way that is inaccessible using currently available x-ray techniques.
△ Less
Submitted 12 June, 2023; v1 submitted 6 May, 2022;
originally announced May 2022.
-
A multimodal operando neutron study of the phase evolution in a graphite electrode
Authors:
Monica-Elisabeta Lăcătuşu,
Luise Theil Kuhn,
Rune E. Johnsen,
Patrick K. M. Tung,
Søren Schmidt,
Takenao Shinohara,
Ryoji Kiyanagi,
Anton S. Tremsin,
Nancy Elewa,
Robin Woracek,
Markus Strobl
Abstract:
Obtaining a complete picture of local processes still poses a significant challenge in battery research. Here we demonstrate an in-situ combination of multimodal neutron imaging with neutron diffraction for spatially resolved operando observations of the lithiation-delithiation of a graphite electrode in a Li-ion battery cell. Throughout the lithiation-delithiation process we image the Li distribu…
▽ More
Obtaining a complete picture of local processes still poses a significant challenge in battery research. Here we demonstrate an in-situ combination of multimodal neutron imaging with neutron diffraction for spatially resolved operando observations of the lithiation-delithiation of a graphite electrode in a Li-ion battery cell. Throughout the lithiation-delithiation process we image the Li distribution based on the local beam attenuation. Simultaneously, we observe the development of the lithiated graphite phases as a function of cycling time and electrode thickness and integral throughout its volume by diffraction contrast imaging and diffraction, respectively. While the conventional imaging data allows to observe the Li uptake in graphite already during the formation of the solid electrolyte interphase, diffraction indicates the onset and development of the Li insertion/extraction globally, which supports the local structural transformation observations by diffraction contrast imaging.
△ Less
Submitted 8 April, 2021;
originally announced April 2021.
-
Synchrotron Microtomography and Neutron Radiography Characterization of the Microstruture and Water Absorption of Concrete from Pompeii
Authors:
Ke Xu,
Anton S. Tremsin,
Jiaqi Li,
Daniela M. Ushizima,
Catherine A. Davy,
Amine Bouterf,
Ying Tsun Su,
Milena Marroccoli,
Anna Maria Mauro,
Massimo Osanna,
Antonio Telesca,
Paulo J. M. Monteiro
Abstract:
There is renewed interest in using advanced techniques to characterize ancient Roman concrete. In the present work, samples were drilled from the "Hospitium" in Pompeii and were analyzed by synchrotron microtomography (uCT) and neutron radiography to study how the microstructure, including the presence of induced cracks, affects their water adsorption. The water distribution and absorptivity were…
▽ More
There is renewed interest in using advanced techniques to characterize ancient Roman concrete. In the present work, samples were drilled from the "Hospitium" in Pompeii and were analyzed by synchrotron microtomography (uCT) and neutron radiography to study how the microstructure, including the presence of induced cracks, affects their water adsorption. The water distribution and absorptivity were quantified by neutron radiography. The 3D crack propagation, pore size distribution and orientation, tortuosity, and connectivity were analyzed from uCT results using advanced imaging methods. The concrete characterization also included classical methods (e.g., differential thermal-thermogravimetric, X-ray diffractometry, and scanning electron microscopy). Ductile fracture patterns were observed once cracks were introduced. When compared to Portland cement mortar/concrete, Pompeii samples had relatively high porosity, low connectivity, and similar coefficient of capillary penetration. In addition, the permeability was predicted from models based on percolation theory and the pore structure data to evaluate the fluid transport properties.
△ Less
Submitted 2 December, 2020; v1 submitted 26 May, 2020;
originally announced May 2020.
-
Tomographic Reconstruction of Triaxial Strain Fields from Bragg-Edge Neutron Imaging
Authors:
J. N. Hendriks,
A. W. T. Gregg,
R. R. Jackson,
C. M. Wensrich,
A. Wills,
A. S. Tremsin,
T. Shinohara,
V. Luzin,
O. Kirstein
Abstract:
This paper presents a proof-of-concept demonstration of triaxial strain tomography from Bragg-edge neutron imaging within a three-dimensional sample. Bragg-edge neutron transmission can provide high-resolution images of the average through thickness strain within a polycrystalline material. This poses an associated rich tomography problem which seeks to reconstruct the full triaxial strain field f…
▽ More
This paper presents a proof-of-concept demonstration of triaxial strain tomography from Bragg-edge neutron imaging within a three-dimensional sample. Bragg-edge neutron transmission can provide high-resolution images of the average through thickness strain within a polycrystalline material. This poses an associated rich tomography problem which seeks to reconstruct the full triaxial strain field from these images. The presented demonstration is an important step towards solving this problem, and towards a technique capable of studying the residual strain and stress within engineering components. A Gaussian process based approach is used that ensures the reconstruction satisfies equilibrium and known boundary conditions. This approach is demonstrated experimentally on a non-trivial steel sample with use of the RADEN instrument at the Japan Proton Accelerator Research Complex. Validation of the reconstruction is provided by comparison with conventional strain scans from the KOWARI constant-wavelength strain diffractometer at the Australian Nuclear Science and Technology Organisation and simulations via finite element analysis.
△ Less
Submitted 28 November, 2019; v1 submitted 20 June, 2019;
originally announced June 2019.
-
Bragg-Edge Elastic Strain Tomography for in situ Systems from Energy-Resolved Neutron Transmission Imaging
Authors:
J. N. Hendriks,
A. W. T. Gregg,
C. M. Wensrich,
A. S. Tremsin,
T. Shinohara,
M. Meylan,
E. H. Kisi,
V. Luzin,
O. Kirsten
Abstract:
Technological developments in high resolution time-of-flight neutron detectors have raised the prospect of tomographic reconstruction of elastic strain fields from Bragg-edge strain images. This approach holds the potential to provide a unique window into the full triaxial stress field within solid samples. While general tomographic reconstruction from these images has been shown to be ill-posed,…
▽ More
Technological developments in high resolution time-of-flight neutron detectors have raised the prospect of tomographic reconstruction of elastic strain fields from Bragg-edge strain images. This approach holds the potential to provide a unique window into the full triaxial stress field within solid samples. While general tomographic reconstruction from these images has been shown to be ill-posed, an injective link between measurements and boundary deformations exists for systems subject to in situ applied loads in the absence of residual stress. Recent work has provided an algorithm to achieve tomographic reconstruction for this class of mechanical system. This letter details an experimental proof-of-concept for this algorithm involving the full reconstruction of a biaxial strain field within a non-trivial steel sample. This work was carried out on the RADEN energy resolved neutron imaging instrument within the Japan Proton Accelerator Research Complex, with validation through Digital Image Correlation and constant wavelength neutron strain scans.
△ Less
Submitted 7 July, 2019; v1 submitted 11 August, 2017;
originally announced August 2017.
-
Time-resolved neutron imaging at ANTARES cold neutron beamline
Authors:
A. S. Tremsin,
V. Dangendorf,
K. Tittelmeier,
B. Schillinger,
M. Schulz,
M. Lerche,
W. B. Feller
Abstract:
In non-destructive evaluation with X-rays light elements embedded in dense, heavy (or high-Z) matrices show little contrast and their structural details can hardly be revealed. Neutron radiography, on the other hand, provides a solution for those cases, in particular for hydrogenous materials, owing to the large neutron scattering cross section of hydrogen and uncorrelated dependency of neutron cr…
▽ More
In non-destructive evaluation with X-rays light elements embedded in dense, heavy (or high-Z) matrices show little contrast and their structural details can hardly be revealed. Neutron radiography, on the other hand, provides a solution for those cases, in particular for hydrogenous materials, owing to the large neutron scattering cross section of hydrogen and uncorrelated dependency of neutron cross section on the atomic number. The majority of neutron imaging experiments at the present time is conducted with static objects mainly due to the limited flux intensity of neutron beamline facilities and sometimes due to the limitations of the detectors. However, some applications require the studies of dynamic phenomena and can now be conducted at several high intensity beamlines such as the recently rebuilt ANTARES beam line at the FRM-II reactor. In this paper we demonstrate the capabilities of time resolved imaging for repetitive processes, where different phases of the process can be imaged simultaneously and integrated over multiple cycles. A fast MCP/Timepix neutron counting detector was used to image the water distribution within a model steam engine operating at 10 Hz frequency. Within <10 minutes integration the amount of water was measured as a function of cycle time with a sub-mm spatial resolution, thereby demonstrating the capabilities of time-resolved neutron radiography for the future applications. The neutron spectrum of the ANTARES beamline as well as transmission spectra of a Fe sample were also measured with the Time Of Flight (TOF) technique in combination with a high resolution beam chopper. The energy resolution of our setup was found to be ~0.8% at 5 meV and ~1.7% at 25 meV.
△ Less
Submitted 31 January, 2015;
originally announced February 2015.