Low background measurement in CANDLES-III for studying the neutrino-less double beta decay of $^{48}$Ca
Authors:
S. Ajimura,
W. M. Chan,
K. Ichimura,
T. Ishikawa,
K. Kanagawa,
B. T. Khai,
T. Kishimoto,
H. Kino,
T. Maeda,
K. Matsuoka,
N. Nakatani,
M. Nomachi,
M. Saka,
K. Seki,
Y. Takemoto,
Y. Takihira,
D. Tanaka,
M. Tanaka,
K. Tetsuno,
V. T. T. Trang,
M. Tsuzuki,
S. Umehara,
K. Akutagawa,
T. Batpurev,
M. Doihara
, et al. (44 additional authors not shown)
Abstract:
We developed a CANDLES-III system to study the neutrino-less double beta (0$νββ$) decay of $^{48}$Ca. The proposed system employs 96 CaF$_{2}$ scintillation crystals (305 kg) with natural Ca ($^{\rm nat.}$Ca) isotope which corresponds 350\,g of $^{48}$Ca. External backgrounds were rejected using a 4$π$ active shield of a liquid scintillator surrounding the CaF$_2$ crystals. The internal background…
▽ More
We developed a CANDLES-III system to study the neutrino-less double beta (0$νββ$) decay of $^{48}$Ca. The proposed system employs 96 CaF$_{2}$ scintillation crystals (305 kg) with natural Ca ($^{\rm nat.}$Ca) isotope which corresponds 350\,g of $^{48}$Ca. External backgrounds were rejected using a 4$π$ active shield of a liquid scintillator surrounding the CaF$_2$ crystals. The internal backgrounds caused by the radioactive impurities within the CaF$_2$ crystals can be reduced effectively through analysis of the signal pulse shape. We analyzed the data obtained in the Kamioka underground for a live-time of 130.4\,days to evaluate the feasibility of the low background measurement with the CANDLES-III detector. Using Monte Carlo simulations, we estimated the background rate from the radioactive impurities in the CaF$_{2}$ crystals and the rate of high energy $γ$-rays caused by the (n, $γ$) reactions induced by environmental neutrons. The expected background rate was in a good agreement with the measured rate, i.e., approximately 10$^{-3}$ events/keV/yr/(kg of $^{\rm nat.}$Ca), in the 0$νββ$ window. In conclusion, the background candidates were estimated properly by comparing the measured energy spectrum with the background simulations. With this measurement method, we performed the first search for 0$νββ$ decay in a low background condition using a detector with a Ca isotope, in which the Ca present was not enriched, in a scale of hundreds of kg. The $^{48}$Ca isotope has a high potential for use in 0$νββ$ decay search, and is expected to be useful for the development of a next-generation detector for highly sensitive measurements.
△ Less
Submitted 19 April, 2021; v1 submitted 20 August, 2020;
originally announced August 2020.
The energy calibration system for CANDLES using (n, γ) reaction
Authors:
T. Iida,
K. Mizukoshi,
T. Ohata,
T. Uehara,
T. Batpurev,
W. M. Chan,
K. Fushimi,
R. Hazama,
M. Ishikawa,
H. Kakubata,
K. Kanagawa,
S. Katagiri,
B. T. Khai,
T. Kishimoto,
X. Li,
T. Maeda,
K. Matsuoka,
K. Morishita,
M. Moser,
K. Nakajima,
M. Nomachi,
I. Ogawa,
M. Shokati,
K. Suzuki,
Y. Takemoto
, et al. (6 additional authors not shown)
Abstract:
CAlcium fluoride for the study of Neutrinos and Dark matters by Low-energy Spectrometer (CANDLES) searches for neutrino-less double beta decay of $^{48}$Ca using a CaF$_2$ scintillator array. A high Q-value of $^{48}$Ca at 4,272 keV enabled us to achieve very low background condition, however, at the same it causes difficulties in calibrating the detector's Q-value region because of the absence of…
▽ More
CAlcium fluoride for the study of Neutrinos and Dark matters by Low-energy Spectrometer (CANDLES) searches for neutrino-less double beta decay of $^{48}$Ca using a CaF$_2$ scintillator array. A high Q-value of $^{48}$Ca at 4,272 keV enabled us to achieve very low background condition, however, at the same it causes difficulties in calibrating the detector's Q-value region because of the absence of a standard high-energy $γ$-ray source. Therefore, we have developed a novel calibration system based on $γ$-ray emission by neutron capture on $^{28}$Si, $^{56}$Fe and $^{58}$Ni nuclei. In the paper, we report the development of the new calibration system as well as the results of energy calibration in CANDLES up to 9 MeV.
△ Less
Submitted 26 March, 2020;
originally announced March 2020.