-
Iso-entropy partially coherent optical fields that cannot be inter-converted unitarily
Authors:
Mitchell Harling,
Varun A. Kelkar,
Kimani C. Toussaint, Jr.,
Ayman F. Abouraddy
Abstract:
For partially coherent optical fields in which a single binary degree of freedom (DoF) is relevant, such as polarization, entropy uniquely identifies the class of optical fields that can be converted into each other via unitary transformations. However, when multiple DoFs are taken into consideration, entropy no longer serves this purpose. We investigate the structure of the family of iso-entropy…
▽ More
For partially coherent optical fields in which a single binary degree of freedom (DoF) is relevant, such as polarization, entropy uniquely identifies the class of optical fields that can be converted into each other via unitary transformations. However, when multiple DoFs are taken into consideration, entropy no longer serves this purpose. We investigate the structure of the family of iso-entropy partially coherent optical fields defined by two binary DoFs (polarization and two spatial modes) and described by a 4x4 coherence matrix G. We find that the rank of G (the number of its non-zero eigenvalues) plays a critical role in this context: whereby any pair of iso-entropy rank-2 fields can be converted into each other unitarily, this is not necessarily the case for a pair of rank-3 or rank-4 fields. Furthermore, unitary transformations between iso-entropy fields of different ranks are strictly forbidden. Instead, such conversions require entropy-maintaining non-unitary transformations that potentially combine filtering projections and randomizing operations. We experimentally synthesize partially coherent iso-entropy optical fields of all ranks, and tomographically reconstruct their coherence matrices. Moreover, we steer the coherence matrix over iso-entropy trajectories that maintain a fixed rank (intra-rank conversion) or that involve changes in the rank (inter-rank conversion). These findings offer a new perspective for the potential utility of partially coherent light in optical communications and sensing.
△ Less
Submitted 18 April, 2024;
originally announced April 2024.
-
Femtosecond laser-assisted selective holding with ultra-low power for direct manipulation of biological specimens
Authors:
Krishangi Krishna,
Joshua A. Burrow,
Zhaowei Jiang,
Wenyu Liu,
Anita Shukla,
Kimani C. Toussaint Jr
Abstract:
Traditional optical tweezers techniques often rely on high-power continuous wave (CW) lasers, which can introduce unwanted thermal effects and photodamage to delicate samples. To overcome these limitations, we demonstrate femtosecond laser assisted selective holding with ultra-low power (FLASH-UP). We find that the FLASH-UP exhibits a five times greater trap stiffness than CW-OT, and can trap at l…
▽ More
Traditional optical tweezers techniques often rely on high-power continuous wave (CW) lasers, which can introduce unwanted thermal effects and photodamage to delicate samples. To overcome these limitations, we demonstrate femtosecond laser assisted selective holding with ultra-low power (FLASH-UP). We find that the FLASH-UP exhibits a five times greater trap stiffness than CW-OT, and can trap at lower intensities. Furthermore, we demonstrate OT of different pathogenic bacteria species and find that FLASH-UP does not impact cell motility. These results pave the way for applications in sorting, bio-sensing, in vivo cell manipulation and single cell analysis.
△ Less
Submitted 12 January, 2024;
originally announced January 2024.
-
Locked entropy in partially coherent fields
Authors:
Mitchell Harling,
Varun A. Kelkar,
Kimani C. Toussaint, Jr.,
Ayman F. Abouraddy
Abstract:
We introduce a taxonomy for partially coherent optical fields spanning multiple degrees of freedom (DoFs) based on the rank of the associated coherence matrix (the number of non-zero eigenvalues). When DoFs comprise two spatial modes and polarization, a fourfold classification emerges, with rank-1 fields corresponding to fully coherent fields. We demonstrate theoretically and confirm experimentall…
▽ More
We introduce a taxonomy for partially coherent optical fields spanning multiple degrees of freedom (DoFs) based on the rank of the associated coherence matrix (the number of non-zero eigenvalues). When DoFs comprise two spatial modes and polarization, a fourfold classification emerges, with rank-1 fields corresponding to fully coherent fields. We demonstrate theoretically and confirm experimentally that these classes have heretofore unrecognized different properties. Specifically, whereas rank-2 fields can always be rendered separable with respect to its DoFs via a unitary transformation, rank-3 fields are always non-separable. Consequently, the entropy for a rank-2 field can always be concentrated into a single DoF (thus ridding the other DoF of statistical fluctuations), whereas some entropy is always 'locked' in one DoF of a rank-3 field.
△ Less
Submitted 21 October, 2023;
originally announced October 2023.
-
Realization of high-dynamic-range broadband magnetic-field sensing with ensemble nitrogen-vacancy centers in diamond
Authors:
Cao Wang,
Qihui Liu,
Yuqiang Hu,
Fei Xie,
Krishangi Krishna,
Nan Wang,
Lihao Wang,
Yang Wang,
Kimani C. Toussaint Jr,
Jiangong Cheng,
Hao Chen,
Zhenyu Wu
Abstract:
We present a new magnetometry method integrating an ensemble of nitrogen-vacancy (NV) centers in a single-crystal diamond with an extended dynamic range for monitoring the fast changing magnetic-field. The NV-center spin resonance frequency is tracked using a closed-loop frequency locked technique with fast frequency hop** to achieve a 10 kHz measurement bandwidth, thus, allowing for the detecti…
▽ More
We present a new magnetometry method integrating an ensemble of nitrogen-vacancy (NV) centers in a single-crystal diamond with an extended dynamic range for monitoring the fast changing magnetic-field. The NV-center spin resonance frequency is tracked using a closed-loop frequency locked technique with fast frequency hop** to achieve a 10 kHz measurement bandwidth, thus, allowing for the detection of fast changing magnetic signals up to 0.723 T/s.This technique exhibits an extended dynamic range subjected to the working bandwidth of the microwave source. This extended dynamic range can reach up to 4.3 mT, which is 86 times broader than the intrinsic dynamic range. The essential components for NV spin control and signal processing such as signal generation, microwave frequency control, data processing and readout are integrated in a board-level system. With this platform, we demonstrate broadband magnetometry with an optimized sensitivity of 4.2 nT-Hz-1/2. This magnetometry method has the potential to be implemented in a multichannel frequency locked vector magnetometer suitable for a wide range of practical applications such as magnetocardiography and high-precision current sensors.
△ Less
Submitted 22 September, 2022;
originally announced September 2022.
-
Excitation of Surface Plasmon Polaritons by Diffraction-Free and Vector Beams
Authors:
Mbaye Diouf,
Joshua A. Burrow,
Krishangi Krishna,
Rachel Odessey,
Ayman F. Abouraddy,
Kimani C. Toussaint Jr
Abstract:
Surface plasmon polaritons (SPPs) are traditionally excited by plane waves within the Rayleigh range of a focused transverse magnetic (TM) Gaussian beam. Here, we investigate and confirm the coupling between SPPs and two-dimensional Gaussian and Bessel-Gauss wave packets, as well as one-dimensional light sheets and space-time wave packets. We encode the incoming wavefronts with spatially varying s…
▽ More
Surface plasmon polaritons (SPPs) are traditionally excited by plane waves within the Rayleigh range of a focused transverse magnetic (TM) Gaussian beam. Here, we investigate and confirm the coupling between SPPs and two-dimensional Gaussian and Bessel-Gauss wave packets, as well as one-dimensional light sheets and space-time wave packets. We encode the incoming wavefronts with spatially varying states of polarization then couple the respective TM components of radial and azimuthal vector beam profiles to confirm SPP polarization-correlation and spatial-mode selectivity. Our results do not require material optimization or multi-dimensional confinement via periodically corrugated metal surfaces to achieve coupling at greater extents. Hereby, outlining a pivotal, yet commonly overlooked, path towards the development of long-range biosensors and all-optical integrated plasmonic circuits.
△ Less
Submitted 19 May, 2022;
originally announced May 2022.
-
Nonlinear focal modulation microscopy
Authors:
Guangyuan Zhao,
Cheng Zheng,
Cuifang Kuang,
Renjie Zhou,
Mohammad M Kabir,
Kimani C. Toussaint Jr.,
Wensheng Wang,
Liang Xu,
Haifeng Li,
Peng Xiu,
Xu Liu
Abstract:
Here we report nonlinear focal modulation microscopy (NFOMM) to achieve super-resolution imaging. Abandoning the previous persistence on minimizing the size of Gaussian emission pattern by directly narrowing (e.g. Minimizing the detection pinhole in Airyscan, Zeiss) or by indirectly peeling its outer profiles (e.g., Depleting the outer emission region in STED, stimulated emission microscopy) in po…
▽ More
Here we report nonlinear focal modulation microscopy (NFOMM) to achieve super-resolution imaging. Abandoning the previous persistence on minimizing the size of Gaussian emission pattern by directly narrowing (e.g. Minimizing the detection pinhole in Airyscan, Zeiss) or by indirectly peeling its outer profiles (e.g., Depleting the outer emission region in STED, stimulated emission microscopy) in pointwise scanning scenarios, we stick to a more general basis------ maximizing the system frequency shifting ability. In NFOMM, we implement a nonlinear focal modulation by applying phase modulations with high-intensity illumination, thereby extending the effective spatial-frequency bandwidth of the imaging system for reconstructing super-resolved images. NFOMM employs a spatial light modulator (SLM) for assisting pattern-modulated pointwise scanning, making the system single beam path while achieving a transverse resolution of 60 nm on imaging fluorescent nanoparticles. While exploring a relatively simple and flexible system, the imagingperformance of NFOMM is comparable with STED as evidenced in imaging nuclear pore complexes, demonstrating NFOMM is a suitable observation tool for fundamental studies in biology. Since NFOMM is implemented as an add-on module to an existing laser scanning microscope and easy to be aligned, we anticipate it will be adopted rapidly by the biological community.
△ Less
Submitted 4 November, 2017;
originally announced November 2017.
-
Demonstration of an optical-coherence converter
Authors:
Chukwuemeka O. Okoro,
H. Esat Kondakci,
Ayman F. Abouraddy,
Kimani C. Toussaint, Jr
Abstract:
Studying the coherence of an optical field is typically compartmentalized with respect to its different optical degrees of freedom (DoFs) -- spatial, temporal, and polarization. Although this traditional approach succeeds when the DoFs are uncoupled, it fails at capturing key features of the field's coherence if the DOFs are indeed correlated -- a situation that arises often. By viewing coherence…
▽ More
Studying the coherence of an optical field is typically compartmentalized with respect to its different optical degrees of freedom (DoFs) -- spatial, temporal, and polarization. Although this traditional approach succeeds when the DoFs are uncoupled, it fails at capturing key features of the field's coherence if the DOFs are indeed correlated -- a situation that arises often. By viewing coherence as a `resource' that can be shared among the DoFs, it becomes possible to convert the entropy associated with the fluctuations in one DoF to another DoF that is initially fluctuation-free. Here, we verify experimentally that coherence can indeed be reversibly exchanged -- without loss of energy -- between polarization and the spatial DoF of a partially coherent field. Starting from a linearly polarized spatially incoherent field -- one that produces no spatial interference fringes -- we obtain a spatially coherent field that is unpolarized. By reallocating the entropy to polarization, the field becomes invariant with regards to the action of a polarization scrambler, thus suggesting a strategy for avoiding the deleterious effects of a randomizing system on a DoF of the optical field.
△ Less
Submitted 13 June, 2017;
originally announced June 2017.
-
Saturated absorption competition microscopy
Authors:
Guangyuan Zhao,
Mohammad M Kabir,
Kimani C. Toussaint Jr.,
Cuifang Kuang,
Cheng Zheng,
Zhongzhi Yu,
Xu Liu
Abstract:
We introduce the concept of saturated absorption competition (SAC) microscopy as a means of providing sub-diffraction spatial resolution in fluorescence imaging. Unlike the post-competition process between stimulated and spontaneous emission that is used in stimulated emission depletion (STED) microscopy, SAC microscopy breaks the diffraction limit by emphasizing a pre-competition process that occ…
▽ More
We introduce the concept of saturated absorption competition (SAC) microscopy as a means of providing sub-diffraction spatial resolution in fluorescence imaging. Unlike the post-competition process between stimulated and spontaneous emission that is used in stimulated emission depletion (STED) microscopy, SAC microscopy breaks the diffraction limit by emphasizing a pre-competition process that occurs in the fluorescence absorption stage in a manner that shares similarities with ground-state depletion (GSD) microscopy. Moreover, unlike both STED and GSD microscopy, SAC microscopy offers a reduction in complexity and cost by utilizing only a single continuous-wave laser diode and an illumination intensity that is ~ 20x smaller than that used in STED. Our approach can be physically implemented in a confocal microscope by dividing the input laser source into a time-modulated primary excitation beam and a doughnut-shaped saturation beam, and subsequently employing a homodyne detection scheme to select the modulated fluorescence signal. Herein, we provide both a physico-chemical model of SAC and experimentally demonstrate by way of a proof-of-concept experiment a transverse spatial resolution of ~lambda/6.
△ Less
Submitted 23 January, 2017;
originally announced January 2017.
-
Entangled-photon ellipsometry
Authors:
Ayman F. Abouraddy,
Kimani C. Toussaint, Jr.,
Alexander V. Sergienko,
Bahaa E. A. Saleh,
Malvin C. Teich
Abstract:
Performing reliable measurements in optical metrology, such as those needed in ellipsometry, requires a calibrated source and detector, or a well-characterized reference sample. We present a novel interferometric technique to perform reliable ellipsometric measurements. This technique relies on the use of a non-classical optical source, namely polarization-entangled twin photons generated by spo…
▽ More
Performing reliable measurements in optical metrology, such as those needed in ellipsometry, requires a calibrated source and detector, or a well-characterized reference sample. We present a novel interferometric technique to perform reliable ellipsometric measurements. This technique relies on the use of a non-classical optical source, namely polarization-entangled twin photons generated by spontaneous parametric downconversion from a nonlinear crystal, in conjunction with a coincidence-detection scheme. Ellipsometric measurements acquired with this scheme are absolute, i.e., they require neither source nor detector calibration, nor do they require a reference.
△ Less
Submitted 15 February, 2002;
originally announced February 2002.
-
Ellipsometric measurements by use of photon pairs generated by spontaneous parametric down-conversion
Authors:
Ayman F. Abouraddy,
Kimani C. Toussaint, Jr.,
Alexander V. Sergienko,
Bahaa E. A. Saleh,
Malvin C. Teich
Abstract:
We present a novel interferometric technique for performing ellipsometric measurements. This technique relies on the use of a non-classical optical source, namely, polarization-entangled twin photons generated by spontaneous parametric down-conversion from a nonlinear crystal, in conjunction with a coincidence-detection scheme. Ellipsometric measurements acquired with this scheme are absolute; i…
▽ More
We present a novel interferometric technique for performing ellipsometric measurements. This technique relies on the use of a non-classical optical source, namely, polarization-entangled twin photons generated by spontaneous parametric down-conversion from a nonlinear crystal, in conjunction with a coincidence-detection scheme. Ellipsometric measurements acquired with this scheme are absolute; i.e., they do not require source and detector calibration.
△ Less
Submitted 12 October, 2001;
originally announced October 2001.