-
First Direct-Detection Constraints on eV-Scale Hidden-Photon Dark Matter with DAMIC at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
B. A. Cervantes Vergara,
A. E. Chavarria,
C. R. Chavez,
J. R. T. de Mello Neto,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
R. Gaïor,
Y. Guardincerri,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
A. Letessier-Selvon,
J. Liao,
A. Matalon,
V. B. B. Mello,
J. Molina
, et al. (13 additional authors not shown)
Abstract:
We present direct detection constraints on the absorption of hidden-photon dark matter with particle masses in the range 1.2-30 eV$c^{-2}$ with the DAMIC experiment at SNOLAB. Under the assumption that the local dark matter is entirely constituted of hidden photons, the sensitivity to the kinetic mixing parameter $κ$ is competitive with constraints from solar emission, reaching a minimum value of…
▽ More
We present direct detection constraints on the absorption of hidden-photon dark matter with particle masses in the range 1.2-30 eV$c^{-2}$ with the DAMIC experiment at SNOLAB. Under the assumption that the local dark matter is entirely constituted of hidden photons, the sensitivity to the kinetic mixing parameter $κ$ is competitive with constraints from solar emission, reaching a minimum value of 2.2$\times$$10^{-14}$ at 17 eV$c^{-2}$. These results are the most stringent direct detection constraints on hidden-photon dark matter in the galactic halo with masses 3-12 eV$c^{-2}$ and the first demonstration of direct experimental sensitivity to ionization signals $<$12 eV from dark matter interactions.
△ Less
Submitted 11 April, 2017; v1 submitted 9 November, 2016;
originally announced November 2016.
-
The CONNIE experiment
Authors:
CONNIE Collaboration,
A. Aguilar-Arevalo,
X. Bertou,
C. Bonifazi,
M. Butner,
G. Cancelo,
A. Castaneda Vazquez,
B. Cervantes Vergara,
C. R. Chavez,
H. Da Motta,
J. C. D'Olivo,
J. Dos Anjos,
J. Estrada,
G. Fernandez Moroni,
R. Ford,
A. Foguel,
K. P. Hernandez Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
K. Kuk,
H. P. Lima Jr.,
M. Makler,
J. Molina,
G. Moreno-Granados
, et al. (6 additional authors not shown)
Abstract:
The CONNIE experiment uses fully depleted, high resistivity CCDs as particle detectors in an attempt to measure for the first time the Coherent Neutrino-Nucleus Elastic Scattering of antineutrinos from a nuclear reactor with silicon nuclei.This talk, given at the XV Mexican Workshop on Particles and Fields (MWPF), discussed the potential of CONNIE to perform this measurement, the installation prog…
▽ More
The CONNIE experiment uses fully depleted, high resistivity CCDs as particle detectors in an attempt to measure for the first time the Coherent Neutrino-Nucleus Elastic Scattering of antineutrinos from a nuclear reactor with silicon nuclei.This talk, given at the XV Mexican Workshop on Particles and Fields (MWPF), discussed the potential of CONNIE to perform this measurement, the installation progress at the Angra dos Reis nuclear power plant, as well as the plans for future upgrades.
△ Less
Submitted 10 October, 2016; v1 submitted 4 August, 2016;
originally announced August 2016.
-
Search for low-mass WIMPs in a 0.6 kg day exposure of the DAMIC experiment at SNOLAB
Authors:
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
B. A. Cervantes Vergara,
A. E. Chavarria,
C. R. Chavez,
J. R. T. de Mello Neto,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
R. Gaïor,
Y. Guandincerri,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
A. Letessier-Selvon,
J. Liao,
J. Molina,
J. R. Peña,
P. Privitera
, et al. (13 additional authors not shown)
Abstract:
We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices down to a signal of 60 eV electron equivalent. The data are consistent with radiogenic backgrounds, and constraints on the spin-independent WIMP-nucleon elastic…
▽ More
We present results of a dark matter search performed with a 0.6 kg day exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices down to a signal of 60 eV electron equivalent. The data are consistent with radiogenic backgrounds, and constraints on the spin-independent WIMP-nucleon elastic-scattering cross section are accordingly placed. A region of parameter space relevant to the potential signal from the CDMS-II Si experiment is excluded using the same target for the first time. This result obtained with a limited exposure demonstrates the potential to explore the low-mass WIMP region (<10 GeV/$c^{2}$) of the upcoming DAMIC100, a 100 g detector currently being installed in SNOLAB.
△ Less
Submitted 9 November, 2016; v1 submitted 25 July, 2016;
originally announced July 2016.
-
Results of the engineering run of the Coherent Neutrino Nucleus Interaction Experiment (CONNIE)
Authors:
A. Aguilar-Arevalo,
X. Bertou,
C. Bonifazi,
M. Butner,
G. Cancelo,
A. Castaneda Vazquez,
C. R. Chavez,
H. Da Motta,
J. C. DOlivo,
J. Dos Anjos,
J. Estrada,
G. Fernandez Moroni,
R. Ford,
A. Foguel,
K. P. Hernandez Torres,
F. Izraelevitch,
H. P. Lima Jr.,
B. Kilminster,
K. Kuk,
M. Makler,
J. Molina,
G. Moreno-Granados,
J. M. Moro,
E. E. Paolini,
M. Sofo Haro
, et al. (3 additional authors not shown)
Abstract:
The CONNIE detector prototype is operating at a distance of 30 m from the core of a 3.8 GW$_{\rm th}$ nuclear reactor with the goal of establishing Charge-Coupled Devices (CCD) as a new technology for the detection of coherent elastic neutrino-nucleus scattering. We report on the results of the engineering run with an active mass of 4 g of silicon. The CCD array is described, and the performance o…
▽ More
The CONNIE detector prototype is operating at a distance of 30 m from the core of a 3.8 GW$_{\rm th}$ nuclear reactor with the goal of establishing Charge-Coupled Devices (CCD) as a new technology for the detection of coherent elastic neutrino-nucleus scattering. We report on the results of the engineering run with an active mass of 4 g of silicon. The CCD array is described, and the performance observed during the first year is discussed. A compact passive shield was deployed for the detector, producing an order of magnitude reduction in the background rate. The remaining background observed during the run was stable, and dominated by internal contamination in the detector packaging materials. The {\it in-situ} calibration of the detector using X-ray lines from fluorescence demonstrates good stability of the readout system. The event rates with the reactor on and off are compared, and no excess is observed coming from nuclear fission at the power plant. The upper limit for the neutrino event rate is set two orders of magnitude above the expectations for the standard model. The results demonstrate the cryogenic CCD-based detector can be remotely operated at the reactor site with stable noise below 2 e$^-$ RMS and stable background rates. The success of the engineering test provides a clear path for the upgraded 100 g detector to be deployed during 2016.
△ Less
Submitted 5 April, 2016;
originally announced April 2016.
-
The DAMIC dark matter experiment
Authors:
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
D. Bole,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
A. E. Chavarria,
J. R. T. de Mello Neto,
S. Dixon,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
J. Liao,
M. López,
J. Molina,
G. Moreno-Granados,
J. Pena,
P. Privitera,
Y. Sarkis
, et al. (8 additional authors not shown)
Abstract:
The DAMIC (Dark Matter in CCDs) experiment uses high resistivity, scientific grade CCDs to search for dark matter. The CCD's low electronic noise allows an unprecedently low energy threshold of a few tens of eV that make it possible to detect silicon recoils resulting from interactions of low mass WIMPs. In addition the CCD's high spatial resolution and the excellent energy response results in ver…
▽ More
The DAMIC (Dark Matter in CCDs) experiment uses high resistivity, scientific grade CCDs to search for dark matter. The CCD's low electronic noise allows an unprecedently low energy threshold of a few tens of eV that make it possible to detect silicon recoils resulting from interactions of low mass WIMPs. In addition the CCD's high spatial resolution and the excellent energy response results in very effective background identification techniques. The experiment has a unique sensitivity to dark matter particles with masses below 10 GeV/c$^2$. Previous results have demonstrated the potential of this technology, motivating the construction of DAMIC100, a 100 grams silicon target detector currently being installed at SNOLAB. In this contribution, the mode of operation and unique imaging capabilities of the CCDs, and how they may be exploited to characterize and suppress backgrounds will be discussed, as well as physics results after one year of data taking.
△ Less
Submitted 7 October, 2015;
originally announced October 2015.
-
Status of the DAMIC direct dark matter search experiment
Authors:
DAMIC Collaboration,
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
D. Boule,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
A. E. Chavarría,
J. R. T. de Melo Neto,
S. Dixon,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
J. Liao,
M. López,
J. Molina,
G. Moreno-Granados,
J. Pena,
P. Privitera
, et al. (9 additional authors not shown)
Abstract:
The DAMIC experiment uses fully depleted, high resistivity CCDs to search for dark matter particles. With an energy threshold $\sim$50 eV$_{ee}$, and excellent energy and spatial resolutions, the DAMIC CCDs are well-suited to identify and suppress radioactive backgrounds, having an unrivaled sensitivity to WIMPs with masses $<$6 GeV/$c^2$. Early results motivated the construction of a 100 g detect…
▽ More
The DAMIC experiment uses fully depleted, high resistivity CCDs to search for dark matter particles. With an energy threshold $\sim$50 eV$_{ee}$, and excellent energy and spatial resolutions, the DAMIC CCDs are well-suited to identify and suppress radioactive backgrounds, having an unrivaled sensitivity to WIMPs with masses $<$6 GeV/$c^2$. Early results motivated the construction of a 100 g detector, DAMIC100, currently being installed at SNOLAB. This contribution discusses the installation progress, new calibration efforts near the threshold, a preliminary result with 2014 data, and the prospects for physics results after one year of data taking.
△ Less
Submitted 8 December, 2015; v1 submitted 30 September, 2015;
originally announced October 2015.
-
Measurement of radioactive contamination in the high-resistivity silicon CCDs of the DAMIC experiment
Authors:
A. Aguilar-Arevalo,
D. Amidei,
X. Bertou,
D. Bole,
M. Butner,
G. Cancelo,
A. Castañeda Vázquez,
A. E. Chavarria,
J. R. T. de Mello Neto,
S. Dixon,
J. C. D'Olivo,
J. Estrada,
G. Fernandez Moroni,
K. P. Hernández Torres,
F. Izraelevitch,
A. Kavner,
B. Kilminster,
I. Lawson,
J. Liao,
M. López,
J. Molina,
G. Moreno-Granados,
J. Pena,
P. Privitera,
Y. Sarkis
, et al. (8 additional authors not shown)
Abstract:
We present measurements of radioactive contamination in the high-resistivity silicon charge-coupled devices (CCDs) used by the DAMIC experiment to search for dark matter particles. Novel analysis methods, which exploit the unique spatial resolution of CCDs, were developed to identify $α$ and $β$ particles. Uranium and thorium contamination in the CCD bulk was measured through $α$ spectroscopy, wit…
▽ More
We present measurements of radioactive contamination in the high-resistivity silicon charge-coupled devices (CCDs) used by the DAMIC experiment to search for dark matter particles. Novel analysis methods, which exploit the unique spatial resolution of CCDs, were developed to identify $α$ and $β$ particles. Uranium and thorium contamination in the CCD bulk was measured through $α$ spectroscopy, with an upper limit on the $^{238}$U ($^{232}$Th) decay rate of 5 (15) kg$^{-1}$ d$^{-1}$ at 95% CL. We also searched for pairs of spatially correlated electron tracks separated in time by up to tens of days, as expected from $^{32}$Si-$^{32}$P or $^{210}$Pb-$^{210}$Bi sequences of $β$ decays. The decay rate of $^{32}$Si was found to be $80^{+110}_{-65}$ kg$^{-1}$ d$^{-1}$ (95% CI). An upper limit of $\sim$35 kg$^{-1}$ d$^{-1}$ (95% CL) on the $^{210}$Pb decay rate was obtained independently by $α$ spectroscopy and the $β$ decay sequence search. These levels of radioactive contamination are sufficiently low for the successful operation of CCDs in the forthcoming 100 g DAMIC detector.
△ Less
Submitted 9 July, 2015; v1 submitted 8 June, 2015;
originally announced June 2015.