3D distortion-free, reduced field of view diffusion-prepared GRE at 3T
Authors:
Sarah McElroy,
Raphael Tomi-Tricot,
Jon Cleary,
Shawna Kinsella,
Sami Jeljeli,
Vicky Goh,
Radhouene Neji
Abstract:
Purpose: To develop a 3D distortion-free reduced-FOV diffusion-prepared GRE sequence and demonstrate its in-vivo application for diffusion imaging of the spinal cord in healthy volunteers. Methods: A 3D multi-shot reduced-FOV diffusion-prepared GRE (RFOV-DP-GRE) acquisition is achieved using a slice-selective tip-down pulse in the phase encoding direction in the diffusion preparation, combined wit…
▽ More
Purpose: To develop a 3D distortion-free reduced-FOV diffusion-prepared GRE sequence and demonstrate its in-vivo application for diffusion imaging of the spinal cord in healthy volunteers. Methods: A 3D multi-shot reduced-FOV diffusion-prepared GRE (RFOV-DP-GRE) acquisition is achieved using a slice-selective tip-down pulse in the phase encoding direction in the diffusion preparation, combined with magnitude stabilisers. The efficacy of the developed reduced FOV approach and accuracy of ADC estimates were evaluated in a phantom. In addition, 5 healthy volunteers were enrolled and scanned at 3T using the proposed sequence and a standard spin echo diffusion-weighted single-shot EPI sequence (DW-SS-EPI) for spinal cord imaging. Image quality, perceived SNR and image distortion were assessed by two expert readers and quantitative measurements of apparent SNR were performed. Results: The phantom scan demonstrates the efficacy of the proposed reduced FOV approach. Consistent ADC estimates were measured with RFOV-DP-GRE when compared with DW-SS-EPI. In-vivo, RFOV-DP-GRE demonstrated improved image quality and reduced perceived distortion, while maintaining perceived SNR compared to DW-SS-EPI. Conclusion: 3D Distortion-free diffusion-prepared imaging can be achieved using the proposed sequence
△ Less
Submitted 24 June, 2024;
originally announced June 2024.
-
Fully automated planning for anatomical fetal brain MRI on 0.55T
Authors:
Sara Neves Silva,
Sarah McElroy,
Jordina Aviles Verdera,
Kathleen Colford,
Kamilah St Clair,
Raphael Tomi-Tricot,
Alena Uus,
Valery Ozenne,
Megan Hall,
Lisa Story,
Kuberan Pushparajah,
Mary A Rutherford,
Joseph V Hajnal,
Jana Hutter
Abstract:
Purpose: Widening the availability of fetal MRI with fully automatic real-time planning of radiological brain planes on 0.55T MRI. Methods: Deep learning-based detection of key brain landmarks on a whole-uterus EPI scan enables the subsequent fully automatic planning of the radiological single-shot Turbo Spin Echo acquisitions. The landmark detection pipeline was trained on over 120 datasets from…
▽ More
Purpose: Widening the availability of fetal MRI with fully automatic real-time planning of radiological brain planes on 0.55T MRI. Methods: Deep learning-based detection of key brain landmarks on a whole-uterus EPI scan enables the subsequent fully automatic planning of the radiological single-shot Turbo Spin Echo acquisitions. The landmark detection pipeline was trained on over 120 datasets from varying field strength, echo times and resolutions and quantitatively evaluated. The entire automatic planning solution was tested prospectively in nine fetal subjects between 20 and 37 weeks. Comprehensive evaluation of all steps, the distance between manual and automatic landmarks, the planning quality and the resulting image quality was conducted. Results: Prospective automatic planning was performed in real-time without latency in all subjects. The landmark detection accuracy was 4.21+-2.56 mm for the fetal eyes and 6.47+-3.23 for the cerebellum, planning quality was 2.44/3 (compared to 2.56/3 for manual planning) and diagnostic image quality was 2.14 compared to 2.07 for manual planning. Conclusions: Real-time automatic planning of all three key fetal brain planes was successfully achieved and will pave the way towards simplifying the acquisition of fetal MRI thereby widening the availability of this modality in non-specialist centres.
△ Less
Submitted 18 January, 2024;
originally announced January 2024.
-
An automated pipeline for quantitative T2* fetal body MRI and segmentation at low field
Authors:
Kelly Payette,
Alena Uus,
Jordina Aviles Verdera,
Carla Avena Zampieri,
Megan Hall,
Lisa Story,
Maria Deprez,
Mary A. Rutherford,
Joseph V. Hajnal,
Sebastien Ourselin,
Raphael Tomi-Tricot,
Jana Hutter
Abstract:
Fetal Magnetic Resonance Imaging at low field strengths is emerging as an exciting direction in perinatal health. Clinical low field (0.55T) scanners are beneficial for fetal imaging due to their reduced susceptibility-induced artefacts, increased T2* values, and wider bore (widening access for the increasingly obese pregnant population). However, the lack of standard automated image processing to…
▽ More
Fetal Magnetic Resonance Imaging at low field strengths is emerging as an exciting direction in perinatal health. Clinical low field (0.55T) scanners are beneficial for fetal imaging due to their reduced susceptibility-induced artefacts, increased T2* values, and wider bore (widening access for the increasingly obese pregnant population). However, the lack of standard automated image processing tools such as segmentation and reconstruction hampers wider clinical use. In this study, we introduce a semi-automatic pipeline using quantitative MRI for the fetal body at low field strength resulting in fast and detailed quantitative T2* relaxometry analysis of all major fetal body organs. Multi-echo dynamic sequences of the fetal body were acquired and reconstructed into a single high-resolution volume using deformable slice-to-volume reconstruction, generating both structural and quantitative T2* 3D volumes. A neural network trained using a semi-supervised approach was created to automatically segment these fetal body 3D volumes into ten different organs (resulting in dice values > 0.74 for 8 out of 10 organs). The T2* values revealed a strong relationship with GA in the lungs, liver, and kidney parenchyma (R^2>0.5). This pipeline was used successfully for a wide range of GAs (17-40 weeks), and is robust to motion artefacts. Low field fetal MRI can be used to perform advanced MRI analysis, and is a viable option for clinical scanning.
△ Less
Submitted 9 August, 2023;
originally announced August 2023.
-
Parallel transmit PUlse design for Saturation Homogeneity (PUSH) for Magnetization Transfer imaging at 7T
Authors:
David Leitão,
Raphael Tomi-Tricot,
Pip Bridgen,
Tom Wilkinson,
Patrick Liebig,
Rene Gumbrecht,
Dieter Ritter,
Sharon L. Giles,
Ana Baburamani,
Jan Sedlacik,
Joseph V. Hajnal,
Shaihan J. Malik
Abstract:
Purpose: This work proposes a novel RF pulse design for parallel transmit (pTx) systems to obtain uniform saturation of semisolid magnetization for Magnetization Transfer (MT) contrast in the presence of transmit field ($B_1^+$) inhomogeneities. The semisolid magnetization is usually modeled as being purely longitudinal, with the applied $B_1^+$ field saturating but not rotating its magnetization,…
▽ More
Purpose: This work proposes a novel RF pulse design for parallel transmit (pTx) systems to obtain uniform saturation of semisolid magnetization for Magnetization Transfer (MT) contrast in the presence of transmit field ($B_1^+$) inhomogeneities. The semisolid magnetization is usually modeled as being purely longitudinal, with the applied $B_1^+$ field saturating but not rotating its magnetization, thus standard pTx pulse design methods do not apply. Theory and Methods: Pulse design for Saturation Homogeneity (PUSH) optimizes pTx RF pulses by considering uniformity of root-mean squared $B_1^+$, $B_1^{rms}$, which relates to the rate of semisolid saturation. Here we considered designs consisting of a small number of spatially non-selective sub-pulses optimized over either a single 2D plane or 3D. Simulations and in vivo experiments on a 7T Terra system with an 8-TX Nova head coil in 5 subjects were carried out to study the homogenization of $B_1^{rms}$ and of the MT contrast by acquiring MT ratio maps. Results: Simulations and in vivo experiments showed up to 6 and 2 times more uniform $B_1^{rms}$ compared to circular polarized (CP) mode for 2D and 3D optimizations, respectively. This translated into 4 and 1.25 times more uniform MT contrast, consistently for all subjects, where 2 sub-pulses were enough for the implementation and coil used. Conclusion: The proposed PUSH method obtains more uniform and higher MT contrast than CP mode within the same SAR budget.
△ Less
Submitted 16 January, 2022;
originally announced January 2022.
-
An 8 channel parallel transmit system with current sensor feedback for MRI-guided interventional applications
Authors:
Felipe Godinez,
Raphael Tomi-Tricot,
Matthias Barthel,
Gunthard Lykowsky,
Greig Scott,
Reza Razavi,
Joseph Hajnal,
Shaihan Malik
Abstract:
Background: Parallel transmit (pTx) has introduced many benefits to MRI with regard to decreased specific absorption rates and improved transmit field homogeneity, of particular importance in applications at higher magnetic field strengths. PTx has also been proposed as a solution to mitigating dangerous RF induced heating of elongated conductive devices such as those used in cardiac interventions…
▽ More
Background: Parallel transmit (pTx) has introduced many benefits to MRI with regard to decreased specific absorption rates and improved transmit field homogeneity, of particular importance in applications at higher magnetic field strengths. PTx has also been proposed as a solution to mitigating dangerous RF induced heating of elongated conductive devices such as those used in cardiac interventions. In this work we present a system that can augment a conventional scanner with pTx, in particular for use in interventional MRI for guidewire safety. Methods: The pTx system was designed to work in-line with a 1.5T MRI while the RF synthesis and imaging control was maintained on the host MR scanner. The add on pTx system relies on the RF transmit signal, unblanking pulse, and a protocol driven trigger from the scanner. The RF transmit was split into multiple fully modulated transmit signals to drive an array of custom transceiver coils. The performance of the 8-channel implementation was tested with regards to active and real-time control of RF induced currents on a standard guidewire, heating mitigation tests, and anatomical imaging in a sheep torso. Results: The pTx system was intended to update RF shims in real-time and it was demonstrated that the safe RF shim could be determined while the guidewire is moved. The anatomical imaging demonstrated that heart anatomy and neighbouring structures can be fully imaged with the pTx system inline. Conclusion: We have presented the design and performance of a real-time feedback control pTx system capable of adding such capabilities to a conventional MRI with the focus guidewire imaging in cardiac interventional MRI applications.
△ Less
Submitted 12 April, 2021; v1 submitted 18 March, 2021;
originally announced March 2021.