High-rate, high-resolution single photon X-ray imaging: Medipix4, a large 4-side buttable pixel readout chip with high granularity and spectroscopic capabilities
Authors:
Viros Sriskaran,
Jerome Alozy,
Rafael Ballabriga,
Michael Campbell,
Pinelopi Christodoulou,
Erik Heijne,
Adil Koukab,
Thanushan Kugathasan,
Xavier Llopart,
Markus Piller,
Adithya Pulli,
Jean-Michel Sallese,
Lukas Tlustos
Abstract:
The Medipix4 chip is the latest member in the Medipix/Timepix family of hybrid pixel detector chips aimed at high-rate spectroscopic X-ray imaging using high-Z materials. It can be tiled on all 4 sides making it ideal for constructing large-area detectors with minimal dead area. The chip is designed to read out a sensor of 320 x 320 pixels with dimensions of 75 μm x 75 μm or 160 x 160 pixels with…
▽ More
The Medipix4 chip is the latest member in the Medipix/Timepix family of hybrid pixel detector chips aimed at high-rate spectroscopic X-ray imaging using high-Z materials. It can be tiled on all 4 sides making it ideal for constructing large-area detectors with minimal dead area. The chip is designed to read out a sensor of 320 x 320 pixels with dimensions of 75 μm x 75 μm or 160 x 160 pixels with dimensions of 150 μm x 150 μm. The readout architecture features energy binning of the single photons, which includes charge sharing correction for hits with energy spread over adjacent pixels. This paper presents the specifications, architecture, and circuit implementation of the chip, along with the first electrical measurements.
△ Less
Submitted 21 November, 2023; v1 submitted 16 October, 2023;
originally announced October 2023.
-
Active Personal Eye Lens Dosimetry with the Hybrid Pixelated Dosepix Detector
Authors:
Florian Beißer,
Dennis Haag,
Rafael Ballabriga,
Rolf Behrens,
Michael Campbell,
Christian Fuhg,
Patrick Hufschmidt,
Oliver Hupe,
Carolin Kupillas,
Xavier Llopart,
Jürgen Roth,
Sebastian Schmidt,
Markus Schneider,
Lukas Tlustos,
Winnie Wong,
Hayo Zutz,
Thilo Michel,
Erlangen Centre for Astroparticle Physics,
CERN,
Physikalisch-Technische Bundesantalt,
was with the Erlangen Centre for Astroparticle Physics,
is now with Helene-Lange-Gymnasium,
was with the Erlangen Centre for Astroparticle Physics,
is now with CodeCamp,
:
, et al. (6 additional authors not shown)
Abstract:
Eye lens dosimetry has been an important field of research in the last decade. Dose measurements with a prototype of an active personal eye lens dosemeter based on the Dosepix detector are presented. The personal dose equivalent at $3\,$mm depth of soft tissue, $H_\text{p}(3)$, was measured in the center front of a water-filled cylinder phantom with a height and diameter of $20\,$cm. The energy de…
▽ More
Eye lens dosimetry has been an important field of research in the last decade. Dose measurements with a prototype of an active personal eye lens dosemeter based on the Dosepix detector are presented. The personal dose equivalent at $3\,$mm depth of soft tissue, $H_\text{p}(3)$, was measured in the center front of a water-filled cylinder phantom with a height and diameter of $20\,$cm. The energy dependence of the normalized response is investigated for mean photon energies between $12.4\,$keV and $248\,$keV for continuous reference radiation fields (N-series) according to ISO 4037. The response normalized to N-60 ($\overline{E}=47.9\,\text{keV}$) at $0^\circ$ angle of irradiation stays within the approval limits of IEC 61526 for angles of incidence between $-75^\circ$ and $+75^\circ$. Performance in pulsed photon fields was tested for varying dose rates from $0.1\,\frac{\text{Sv}}{\text{h}}$ up to $1000\,\frac{\text{Sv}}{\text{h}}$ and pulse durations from $1\,\text{ms}$ up to $10\,\text{s}$. The dose measurement works well within the approval limits (acc. to IEC 61526) up to $1\,\frac{\text{Sv}}{\text{h}}$. No significant influence of the pulse duration on the measured dose is found. Reproducibility measurements yield a coefficient of variation which does not exceed $1\,\%$ for two tested eye lens dosemeter prototypes.
△ Less
Submitted 1 August, 2023; v1 submitted 9 May, 2023;
originally announced May 2023.
-
Personal Dosimetry in Direct Pulsed Photon Fields with the Dosepix Detector
Authors:
Dennis Haag,
Sebastian Schmidt,
Patrick Hufschmidt,
Gisela Anton,
Rafael Ballabriga,
Rolf Behrens,
Michael Campbell,
Franziska Eberle,
Christian Fuhg,
Oliver Hupe,
Xavier Llopart,
Jürgen Roth,
Lukas Tlustos,
Winnie Wong,
Hayo Zutz,
Thilo Michel
Abstract:
First investigations regarding dosimetric properties of the hybrid, pixelated, photon-counting Dosepix detector in the direct beam of a pulsed photon field (RQR8) for the personal dose equivalent $H\mathrm{_p(10)}$ are presented. The influence quantities such as pulse duration and dose rate were varied, and their responses were compared to the legal limits provided in PTB-A 23.2. The variation of…
▽ More
First investigations regarding dosimetric properties of the hybrid, pixelated, photon-counting Dosepix detector in the direct beam of a pulsed photon field (RQR8) for the personal dose equivalent $H\mathrm{_p(10)}$ are presented. The influence quantities such as pulse duration and dose rate were varied, and their responses were compared to the legal limits provided in PTB-A 23.2. The variation of pulse duration at a nearly constant dose rate of about 3.7$\,$Sv/h shows a flat response around 1.0 from 3.6$\,$s down to 2$\,$ms. A response close to 1.0 is achieved for dose rates from 0.07$\,$Sv/h to 35$\,$Sv/h for both pixel sizes. Above this dose rate, the large pixels (220$\,μ$m edge length) are below the lower limit. The small pixels (55$\,μ$m edge length) stay within limits up to 704$\,$Sv/h. The count rate linearity is compared to previous results, confirming the saturating count rate for high dose rates.
△ Less
Submitted 30 November, 2022; v1 submitted 12 June, 2021;
originally announced June 2021.
-
$^{62}$Ni($n,γ$) and $^{63}$Ni($n,γ$) cross sections measured at n_TOF/CERN
Authors:
C. Lederer,
C. Massimi,
E. Berthoumieux,
N. Colonna,
R. Dressler,
C. Guerrero,
F. Gunsing,
F. Käppeler,
N. Kivel,
M. Pignatari,
R. Reifarth,
D. Schumann,
A. Wallner,
S. Altstadt,
S. Andriamonje,
J. Andrzejewski,
L. Audouin,
M. Barbagallo,
V. Becares,
F. Becvar,
F. Belloni,
B. Berthier,
J. Billowes,
V. Boccone,
D. Bosnar
, et al. (90 additional authors not shown)
Abstract:
The cross section of the $^{62}$Ni($n,γ$) reaction was measured with the time-of-flight technique at the neutron time-of-flight facility n_TOF at CERN. Capture kernels of 42 resonances were analyzed up to 200~keV neutron energy and Maxwellian averaged cross sections (MACS) from $kT=5-100$ keV were calculated. With a total uncertainty of 4.5%, the stellar cross section is in excellent agreement wit…
▽ More
The cross section of the $^{62}$Ni($n,γ$) reaction was measured with the time-of-flight technique at the neutron time-of-flight facility n_TOF at CERN. Capture kernels of 42 resonances were analyzed up to 200~keV neutron energy and Maxwellian averaged cross sections (MACS) from $kT=5-100$ keV were calculated. With a total uncertainty of 4.5%, the stellar cross section is in excellent agreement with the the KADoNiS compilation at $kT=30$ keV, while being systematically lower up to a factor of 1.6 at higher stellar temperatures. The cross section of the $^{63}$Ni($n,γ$) reaction was measured for the first time at n_TOF. We determined unresolved cross sections from 10 to 270 keV with a systematic uncertainty of 17%. These results provide fundamental constraints on $s$-process production of heavier species, especially the production of Cu in massive stars, which serve as the dominant source of Cu in the solar system.
△ Less
Submitted 19 March, 2014;
originally announced March 2014.
-
The UA9 experimental layout
Authors:
W. Scandale,
G. Arduini,
R. Assmann,
C. Bracco,
F. Cerutti,
J. Christiansen,
S. Gilardoni,
E. Laface,
R. Losito,
A. Masi,
E. Metral,
D. Mirarchi,
S. Montesano,
V. Previtali,
S. Redaelli,
G. Valentino,
P. Schoofs,
G. Smirnov,
L. Tlustos,
E. Bagli,
S. Baricordi,
P. Dalpiaz,
V. Guidi,
A. Mazzolari,
D. Vincenzi
, et al. (36 additional authors not shown)
Abstract:
The UA9 experimental equipment was installed in the CERN-SPS in March '09 with the aim of investigating crystal assisted collimation in coasting mode.
Its basic layout comprises silicon bent crystals acting as primary collimators mounted inside two vacuum vessels. A movable 60 cm long block of tungsten located downstream at about 90 degrees phase advance intercepts the deflected beam.
Scintill…
▽ More
The UA9 experimental equipment was installed in the CERN-SPS in March '09 with the aim of investigating crystal assisted collimation in coasting mode.
Its basic layout comprises silicon bent crystals acting as primary collimators mounted inside two vacuum vessels. A movable 60 cm long block of tungsten located downstream at about 90 degrees phase advance intercepts the deflected beam.
Scintillators, Gas Electron Multiplier chambers and other beam loss monitors measure nuclear loss rates induced by the interaction of the beam halo in the crystal. Roman pots are installed in the path of the deflected particles and are equipped with a Medipix detector to reconstruct the transverse distribution of the im**ing beam. Finally UA9 takes advantage of an LHC-collimator prototype installed close to the Roman pot to help in setting the beam conditions and to analyze the efficiency to deflect the beam. This paper describes in details the hardware installed to study the crystal collimation during 2010.
△ Less
Submitted 29 June, 2011;
originally announced June 2011.