-
High fidelity adaptive mirror simulations with reduced order models
Authors:
Bernadett Stadler,
Roberto Biasi,
Mauro Manetti,
Andreas Obereder,
Ronny Ramlau,
Matteo Tintori
Abstract:
In the design process of large adaptive mirrors numerical simulations represent the first step to evaluate the system design compliance in terms of performance, stability and robustness. For the next generation of Extremely Large Telescopes increased system dimensions and bandwidths lead to the need of modeling not only the deformable mirror alone, but also all the system supporting structure or e…
▽ More
In the design process of large adaptive mirrors numerical simulations represent the first step to evaluate the system design compliance in terms of performance, stability and robustness. For the next generation of Extremely Large Telescopes increased system dimensions and bandwidths lead to the need of modeling not only the deformable mirror alone, but also all the system supporting structure or even the full telescope. The capability to perform the simulations with an acceptable amount of time and computational resources is highly dependent on finding appropriate methods to reduce the size of the resulting dynamic models. In this paper we present a framework developed together with the company Microgate to create a reduced order structural model of a large adaptive mirror as a preprocessing step to the control system simulations. The reduced dynamic model is then combined with the remaining system components allowing to simulate the full adaptive mirror in a computationally efficient way. We analyze the feasibility of our reduced models for Microgate's prototype of the adaptive mirror of the Giant Magellan Telescope.
△ Less
Submitted 17 April, 2024;
originally announced April 2024.
-
Contactless actuators and pyramid wavefront sensor, the SPLATT concept for space active optics: an overview of the project and the last laboratory results
Authors:
Runa Briguglio,
Marco Xompero,
Marcello Scalera,
Marco Riva,
Ciro Del Vecchio,
Luca Carbonaro,
Carmelo Arcidiacono,
Guido Agapito,
Enrico Pinna,
Alessandro Terreri,
Fernando Pedichini,
Riccardo Muradore,
Matteo Tintori,
Daniele Gallieni Roberto Biasi,
Christian Patauner,
Alessandro Zuccaro Marchi
Abstract:
In the last few years the concept of an active space telescope has been greatly developed, to meet demanding requirements with a substantial reduction of tolerances, risks and costs. This is the frame of the LATT project (an ESA TRP) and its follow-up SPLATT (an INAF funded R&D project). Within the SPLATT activities, we outline a novel approach and investigate, both via simulations and in the opti…
▽ More
In the last few years the concept of an active space telescope has been greatly developed, to meet demanding requirements with a substantial reduction of tolerances, risks and costs. This is the frame of the LATT project (an ESA TRP) and its follow-up SPLATT (an INAF funded R&D project). Within the SPLATT activities, we outline a novel approach and investigate, both via simulations and in the optical laboratory, two main elements: an active segmented primary with contactless actuators and a pyramid wavefront sensor (PWFS) to drive the correction chain. The key point is the synergy between them: the sensitivity of the PWFS and the intrinsic stability of a contactless-actuated mirror segment.
Voice-coil, contactless actuators are in facts a natural decoupling layer between the payload and the optical surface and can suppress the high frequency vibration as we verified in the lab. We subjected a 40 cm diameter prototype with 19 actuators to an externally injected vibration spectrum; we then measured optically the reduction of vibrations when the optical surface is floating controlled by the actuators, thus validating the concept at the first stage of the design.
The PWFS, which is largely adopted on ground-based telescope, is a pupil-conjugated sensor and offers a user-selectable sampling and capture range, in order to match different use cases; it is also more sensitive than Shack-Hartmann sensor especially at the low-mid spatial scales. We run a set of numerical simulations with the PWFS measuring the misalignment and phase steps of a JWST-like primary mirrors: we investigated the PWFS sensitivity in the sub-nanometer regime in presence of photon and detector noise, and with guide star magnitudes in the range 8 to 14.
In the paper we discuss the outcomes of the project and present a possible roadmap for further developments.
△ Less
Submitted 1 February, 2023;
originally announced February 2023.
-
X-shooter, the new wide band intermediate resolution spectrograph at the ESO Very Large Telescope
Authors:
Joel Vernet,
H. Dekker,
S. D'Odorico,
L. Kaper,
P. Kjaergaard,
F. Hammer,
S. Randich,
F. Zerbi,
P. M. Groot,
J. Hjorth,
I. Guinouard,
R. Navarro,
T. Adolfse,
P. W. Albers,
J. -P. Amans,
J. J. Andersen,
M. I. Andersen,
P. Binetruy,
P. Bristow,
R. Castillo,
F. Chemla,
L. Christensen,
P. Conconi,
R. Conzelmann,
J. Dam
, et al. (65 additional authors not shown)
Abstract:
X-shooter is the first 2nd generation instrument of the ESO Very Large Telescope(VLT). It is a very efficient, single-target, intermediate-resolution spectrograph that was installed at the Cassegrain focus of UT2 in 2009. The instrument covers, in a single exposure, the spectral range from 300 to 2500 nm. It is designed to maximize the sensitivity in this spectral range through dichroic splitting…
▽ More
X-shooter is the first 2nd generation instrument of the ESO Very Large Telescope(VLT). It is a very efficient, single-target, intermediate-resolution spectrograph that was installed at the Cassegrain focus of UT2 in 2009. The instrument covers, in a single exposure, the spectral range from 300 to 2500 nm. It is designed to maximize the sensitivity in this spectral range through dichroic splitting in three arms with optimized optics, coatings, dispersive elements and detectors. It operates at intermediate spectral resolution (R~4,000 - 17,000, depending on wavelength and slit width) with fixed echelle spectral format (prism cross-dispersers) in the three arms. It includes a 1.8"x4" Integral Field Unit as an alternative to the 11" long slits. A dedicated data reduction package delivers fully calibrated two-dimensional and extracted spectra over the full wavelength range. We describe the main characteristics of the instrument and present its performance as measured during commissioning, science verification and the first months of science operations.
△ Less
Submitted 10 October, 2011;
originally announced October 2011.