-
BlueWalker 3 Redux
Authors:
Anthony Mallama,
Richard E. Cole,
Scott Harrington,
Aaron Worley,
Jay Respler,
Cees Bassa,
Scott Tilley
Abstract:
The BlueWalker 3 satellite is now fainter than during the first months after deployment. The greatest improvement is that the average maximum luminosity near zenith has been reduced from magnitude 1.0 to 2.2. However, the spacecraft is still usually bright enough to interfere with astronomical research.
The BlueWalker 3 satellite is now fainter than during the first months after deployment. The greatest improvement is that the average maximum luminosity near zenith has been reduced from magnitude 1.0 to 2.2. However, the spacecraft is still usually bright enough to interfere with astronomical research.
△ Less
Submitted 4 July, 2024;
originally announced July 2024.
-
BlueWalker 3 Satellite Brightness Characterized and Modeled
Authors:
Anthony Mallama,
Richard E. Cole,
Scott Tilley,
Cees Bassa,
Scott Harrington
Abstract:
The BlueWalker 3 (BW3) satellite was folded into a compact object when launched on 2022 September 11. The spacecraft's apparent visual magnitude initially ranged from about 4 to 8. Observations on November 11 revealed that the brightness increased by 4 magnitudes which indicated that the spacecraft had deployed into a large flat-panel shape. The satellite then faded by several magnitudes in Decemb…
▽ More
The BlueWalker 3 (BW3) satellite was folded into a compact object when launched on 2022 September 11. The spacecraft's apparent visual magnitude initially ranged from about 4 to 8. Observations on November 11 revealed that the brightness increased by 4 magnitudes which indicated that the spacecraft had deployed into a large flat-panel shape. The satellite then faded by several magnitudes in December before returning to its full luminosity; this was followed by additional faint periods in 2023 February and March. We discuss the probable cause of the dimming phenomena and identify a geometrical circumstance where the satellite is abnormally bright. The luminosity of BW3 can be represented with a brightness model which is based on the satellite shape and orientation as well as a reflection function having Lambertian and pseudo-specular components. Apparent magnitudes are most frequently between 2.0 and 3.0. When BW3 is near zenith the magnitude is about 1.4.
△ Less
Submitted 1 May, 2023;
originally announced May 2023.
-
The BlueWalker 3 Satellite Has Faded
Authors:
Anthony Mallama,
Richard E. Cole,
Scott Tilley
Abstract:
Observations of BlueWalker 3 (BW3) beginning on December 8 of this year indicate that its apparent brightness had decreased. We postulate that the orbital beta angle and resultant solar power considerations required an adjustment to the satellite attitude around that time. So, the nominally zenith facing side of the flat-panel shaped spacecraft, which supports the solar array, was tilted toward th…
▽ More
Observations of BlueWalker 3 (BW3) beginning on December 8 of this year indicate that its apparent brightness had decreased. We postulate that the orbital beta angle and resultant solar power considerations required an adjustment to the satellite attitude around that time. So, the nominally zenith facing side of the flat-panel shaped spacecraft, which supports the solar array, was tilted toward the Sun. Consequently, the nadir side, which is seen by observers on the ground, was mostly dark. Thus, BW3 has generally appeared faint and on some occasions was not seen at all. The amount of fading was up to 4 magnitudes. Numerical modeling indicates that the amount of tilt was in the range 13° to 16°. This situation indicates the improvement in the appearance of BW3 from the ground that can be achieved with small tilts of the spacecraft. Satellite operators and astronomers can jointly address the adverse impact of bright satellites on celestial observations based on this finding.
△ Less
Submitted 25 December, 2022;
originally announced January 2023.
-
Optimized Spatial-Spectral CT for Multi-Material Decomposition
Authors:
Matthew Tivnan,
Wenying Wang,
Steven Tilley,
Jeffrey H. Siewerdsen,
J. Webster Stayman
Abstract:
Spectral CT is an emerging modality that uses a data acquisition scheme with varied spectral responses to provide enhanced material discrimination in addition to the structural information of conventional CT. Existing clinical and preclinical designs with this capability include kV-switching, split-filtration, and dual-layer detector systems to provide two spectral channels of projection data. In…
▽ More
Spectral CT is an emerging modality that uses a data acquisition scheme with varied spectral responses to provide enhanced material discrimination in addition to the structural information of conventional CT. Existing clinical and preclinical designs with this capability include kV-switching, split-filtration, and dual-layer detector systems to provide two spectral channels of projection data. In this work, we examine an alternate design based on a spatial-spectral filter. This source-side filter is made up a linear array of materials that divide the incident x-ray beam into spectrally varied beamlets. This design allows for any number of spectral channels; however, each individual channel is sparse in the projection domain. Model-based iterative reconstruction methods can accommodate such sparse spatial-spectral sampling patterns and allow for the incorporation of advanced regularization. With the goal of an optimized physical design, we characterize the effects of design parameters including filter tile order and filter tile width and their impact on material decomposition performance. We present results of numerical simulations that characterize the impact of each design parameter using a realistic CT geometry and noise model to demonstrate feasibility. Results for filter tile order show little change indicating that filter order is a low-priority design consideration. We observe improved performance for narrower filter widths; however, the performance drop-off is relatively flat indicating that wider filter widths are also feasible designs.
△ Less
Submitted 15 October, 2020;
originally announced October 2020.
-
Physical Modeling and Performance of Spatial-Spectral Filters for CT Material Decomposition
Authors:
Matthew Tivnan,
Steven Tilley II,
J. Webster Stayman
Abstract:
Material decomposition for imaging multiple contrast agents in a single acquisition has been made possible by spectral CT: a modality which incorporates multiple photon energy spectral sensitivities into a single data collection. This work presents an investigation of a new approach to spectral CT which does not rely on energy-discriminating detectors or multiple x-ray sources. Instead, a tiled pa…
▽ More
Material decomposition for imaging multiple contrast agents in a single acquisition has been made possible by spectral CT: a modality which incorporates multiple photon energy spectral sensitivities into a single data collection. This work presents an investigation of a new approach to spectral CT which does not rely on energy-discriminating detectors or multiple x-ray sources. Instead, a tiled pattern of K-edge filters are placed in front of the x-ray to create spatially encoded spectra data. For improved sampling, the spatial-spectral filter is moved continuously with respect to the source. A model-based material decomposition algorithm is adopted to directly reconstruct multiple material densities from projection data that is sparse in each spectral channel. Physical effects associated with the x-ray focal spot size and motion blur for the moving filter are expected to impact overall performance. In this work, those physical effects are modeled and a performance analysis is conducted. Specifically, experiments are presented with simulated focal spot widths between 0.2 mm and 4.0 mm. Additionally, filter motion blur is simulated for a linear translation speeds between 50 mm/s and 450 mm/s. The performance differential between a 0.2 mm and a 1.0 mm focal spot is less than 15% suggesting feasibility of the approach with realistic x-ray tubes. Moreover, for reasonable filter actuation speeds, higher speeds are shown to decrease error (due to improved sampling) despite motion-based spectral blur.
△ Less
Submitted 10 August, 2020;
originally announced August 2020.
-
High-Fidelity Modeling of Detector Lag and Gantry Motion in CT Reconstruction
Authors:
Steven Tilley II,
Alejandro Sisniega,
Jeffrey H. Siewerdsen,
J. Webster Stayman
Abstract:
Detector lag and gantry motion during x-ray exposure and integration both result in azimuthal blurring in CT reconstructions. These effects can degrade image quality both for high-resolution features as well as low-contrast details. In this work we consider a forward model for model-based iterative reconstruction (MBIR) that is sufficiently general to accommodate both of these physical effects. We…
▽ More
Detector lag and gantry motion during x-ray exposure and integration both result in azimuthal blurring in CT reconstructions. These effects can degrade image quality both for high-resolution features as well as low-contrast details. In this work we consider a forward model for model-based iterative reconstruction (MBIR) that is sufficiently general to accommodate both of these physical effects. We integrate this forward model in a penalized, weighted, nonlinear least-square style objective function for joint reconstruction and correction of these blur effects. We show that modeling detector lag can reduce/remove the characteristic lag artifacts in head imaging in both a simulation study and physical experiments. Similarly, we show that azimuthal blur ordinarily introduced by gantry motion can be mitigated with proper reconstruction models. In particular, we find the largest image quality improvement at the periphery of the field-of-view where gantry motion artifacts are most pronounced. These experiments illustrate the generality of the underlying forward model, suggesting the potential application in modeling a number of physical effects that are traditionally ignored or mitigated through pre-corrections to measurement data.
△ Less
Submitted 29 May, 2018;
originally announced May 2018.
-
Penalized-Likelihood Reconstruction with High-Fidelity Measurement Models for High-Resolution Cone-Beam Imaging
Authors:
Steven Tilley II,
Matthew Jacobson,
Qian Cao,
Michael Brehler,
Alejandro Sisniega,
Wojciech Zbijewski,
J. Webster Stayman
Abstract:
We present a novel reconstruction algorithm based on a general cone-beam CT forward model which is capable of incorporating the blur and noise correlations that are exhibited in flat-panel CBCT measurement data. Specifically, the proposed model may include scintillator blur, focal-spot blur, and noise correlations due to light spread in the scintillator. The proposed algorithm (GPL-BC) uses a Gaus…
▽ More
We present a novel reconstruction algorithm based on a general cone-beam CT forward model which is capable of incorporating the blur and noise correlations that are exhibited in flat-panel CBCT measurement data. Specifically, the proposed model may include scintillator blur, focal-spot blur, and noise correlations due to light spread in the scintillator. The proposed algorithm (GPL-BC) uses a Gaussian Penalized-Likelihood objective function which incorporates models of Blur and Correlated noise. In a simulation study, GPL-BC was able to achieve lower bias as compared to deblurring followed by FDK as well as a model-based reconstruction method without integration of measurement blur. In the same study, GPL-BC was able to achieve better line-pair reconstructions (in terms of segmented-image accuracy) as compared to deblurring followed by FDK, a model based method without blur, and a model based method with blur but not noise correlations. A prototype extremities quantitative cone-beam CT test bench was used to image a physical sample of human trabecular bone. These data were used to compare reconstructions using the proposed method and model based methods without blur and/or correlation to a registered μCT image of the same bone sample. The GPL-BC reconstructions resulted in more accurate trabecular bone segmentation. Multiple trabecular bone metrics, including Trabecular Thickness (Tb.Th.) were computed for each reconstruction approach as well as the μCT volume. The GPL-BC reconstruction provided the most accurate Tb.Th. measurement, 0.255 mm, as compared to the μCT derived value of 0.193 mm, followed by the GPL-B reconstruction, the GPL-I reconstruction, and then the FDK reconstruction (0.271 mm, 0.309 mm, and 0.335 mm, respectively).
△ Less
Submitted 14 December, 2017;
originally announced December 2017.
-
High-Fidelity Modeling of Shift-Variant Focal-Spot Blur for High-Resolution CT
Authors:
Steven Tilley II,
Wojciech Zbijewski,
J. Webster Stayman
Abstract:
Dedicated application-specific CT systems are popular solutions to high-resolution clinical needs. Some applications, such as mammography and extremities imaging, require spatial resolution beyond current capabilities. Thorough understanding of system properties may help tailor system design, acquisition protocols, and reconstruction algorithms to improve image quality. Using a high-fidelity measu…
▽ More
Dedicated application-specific CT systems are popular solutions to high-resolution clinical needs. Some applications, such as mammography and extremities imaging, require spatial resolution beyond current capabilities. Thorough understanding of system properties may help tailor system design, acquisition protocols, and reconstruction algorithms to improve image quality. Using a high-fidelity measurement model, we analyze the effects of shift-variant focal spot blur due to depth-dependence and anode angulation on image quality throughout the three-dimensional field of view of a simulated extremities scanner. A model of the shift-variant blur associated with this device is then incorporated into a Model-Based Iterative Reconstruction (MBIR) algorithm, which is then compared to FDK and MBIR with simpler blur models at select locations throughout the field of view. We show that shift-variant focal spot blur leads to location-dependent imaging performance. Furthermore, changing the orientation of the X-ray tube alters this spatial dependence. The analysis suggests methods to improve imaging performance based on specific image quality needs. The results also demonstrate that image quality can be improved by combining accurate blur modeling with MBIR. Specifically, across the entire field of view, MBIR with shift-variant blur modeling yielded the best image quality, followed by MBIR with a shift-invariant blur model, MBIR with an identity blur model, and FDK, respectively. These results suggest a number of opportunities for the optimization of imaging system performance in the hardware setup, the imaging protocol, and the reconstruction approach. While the high-fidelity models used here are applied using the specifications of a dedicated extremities imaging system, the methods are general and may be applied to optimize imaging performance in any CT system.
△ Less
Submitted 27 June, 2017;
originally announced June 2017.
-
Model-based Iterative Reconstruction for Flat-Panel Cone-Beam CT with Focal Spot Blur, Detector Blur, and Correlated Noise
Authors:
Steven Tilley II,
Jeffrey H. Siewerdsen,
J. Webster Stayman
Abstract:
While model-based reconstruction methods have been successfully applied to flat-panel cone-beam CT (FP-CBCT) systems, typical implementations ignore both spatial correlations in the projection data as well as system blurs due to the detector and focal spot in the x-ray source. In this work, we develop a forward model for flat-panel-based systems that includes blur and noise correlation associated…
▽ More
While model-based reconstruction methods have been successfully applied to flat-panel cone-beam CT (FP-CBCT) systems, typical implementations ignore both spatial correlations in the projection data as well as system blurs due to the detector and focal spot in the x-ray source. In this work, we develop a forward model for flat-panel-based systems that includes blur and noise correlation associated with finite focal spot size and an indirect detector (e.g., scintillator). This forward model is used to develop a staged reconstruction framework where projection data are deconvolved and log-transformed, followed by a generalized least-squares reconstruction that utilizes a non-diagonal statistical weighting to account for the correlation that arises from the acquisition and data processing chain. We investigate the performance of this novel reconstruction approach in both simulated data and in CBCT test-bench data. In comparison to traditional filtered backprojection and model-based methods that ignore noise correlation, the proposed approach yields a superior noise-resolution tradeoff. For example, for a system with 0.34 mm FWHM scintillator blur and 0.70 FWHM focal spot blur, using the a correlated noise model instead of an uncorrelated noise model increased resolution by 42% (with variance matched at 6.9 x 10^-8 mm^-2 ). While this advantage holds across a wide range of systems with differing blur characteristics, the improvements are greatest for systems where source blur is larger than detector blur.
△ Less
Submitted 14 June, 2017;
originally announced June 2017.
-
Modeling shift-variant X-ray focal spot blur for high-resolution flat-panel cone-beam CT
Authors:
Steven Tilley II,
Wojciech Zbijewski,
Jeffrey H. Siewerdsen,
J. Webster Stayman
Abstract:
Flat-panel cone-beam CT (CBCT) has been applied clinically in a number of high-resolution applications. Increasing geometric magnification can potentially improve resolution, but also increases blur due to an extended x-ray focal-spot. We present a shift-variant focal-spot blur model and incorporate it into a model-based iterative-reconstruction algorithm. We apply this algorithm to simulation and…
▽ More
Flat-panel cone-beam CT (CBCT) has been applied clinically in a number of high-resolution applications. Increasing geometric magnification can potentially improve resolution, but also increases blur due to an extended x-ray focal-spot. We present a shift-variant focal-spot blur model and incorporate it into a model-based iterative-reconstruction algorithm. We apply this algorithm to simulation and CBCT test-bench data. In a trabecular bone simulation study, we find traditional reconstruction approaches without a blur model exhibit shift-variant resolution properties that depend greatly on the acquisition protocol (e.g. short vs. full scans) and the anode angles of the rays used to reconstruct a particular region. For physical CBCT experiments focal spot blur was characterized and a spatial resolution phantom was scanned and reconstructed. In both experiments image quality using the shift-variant model was significantly improved over approaches that modeled no blur or only a shift-invariant blur, suggesting a potential means to overcome traditional CBCT spatial resolution and system design limitations.
△ Less
Submitted 17 October, 2016;
originally announced October 2016.
-
gLISA: geosynchronous Laser Interferometer Space Antenna concepts with off-the-shelf satellites
Authors:
Massimo Tinto,
Daniel DeBra,
Sasha Buchman,
Scott Tilley
Abstract:
We discuss two geosynchronous gravitational wave mission concepts, which we generically name gLISA. One relies on the science instrument hosting program onboard geostationary commercial satellites, while the other takes advantage of recent developments in the aerospace industry that result in dramatic satellite and launching vehicle cost reductions for a dedicated geosynchronous mission. To achiev…
▽ More
We discuss two geosynchronous gravitational wave mission concepts, which we generically name gLISA. One relies on the science instrument hosting program onboard geostationary commercial satellites, while the other takes advantage of recent developments in the aerospace industry that result in dramatic satellite and launching vehicle cost reductions for a dedicated geosynchronous mission. To achieve the required level of disturbance free-fall onboard these large and heavy platforms we propose a "two-stage" drag-free system, which incorporates the Modular Gravitational Reference Sensor (MGRS) (developed at Stanford University) and does not rely on the use of micro-Newton thrusters. Although both mission concepts are characterized by different technical and programmatic challenges, individually they could be flown and operated at a cost significantly lower than those of previously envisioned gravitational wave missions. We estimate both mission concepts to cost less than 500M US$ each, and in the year 2015 we will perform at JPL a detailed selecting mission cost analysis.
△ Less
Submitted 7 October, 2014;
originally announced October 2014.
-
Calculation of Energy Band Diagram of a Photoelectrochemical Water Splitting Cell
Authors:
P. Cendula,
S. D. Tilley,
S. Gimenez,
M. Schmid,
J. Bisquert,
M. Graetzel,
J. O. Schumacher
Abstract:
A physical model is presented for a semiconductor electrode of a photoelectrochemical (PEC) cell, accounting for the potential drop in the Helmholtz layer. Hence both band edge pinning and unpinning are naturally included in our description. The model is based on the continuity equations for charge carriers and direct charge transfer from the energy bands to the electrolyte. A quantitative calcula…
▽ More
A physical model is presented for a semiconductor electrode of a photoelectrochemical (PEC) cell, accounting for the potential drop in the Helmholtz layer. Hence both band edge pinning and unpinning are naturally included in our description. The model is based on the continuity equations for charge carriers and direct charge transfer from the energy bands to the electrolyte. A quantitative calculation of the position of the energy bands and the variation of the quasi-Fermi levels in the semiconductor with respect to the water reduction and oxidation potentials is presented. Calculated current-voltage curves are compared with established analytical models and measurement. Our model calculations are suitable to enhance understanding and improve properties of semiconductors for photoelectrochemical water splitting.
△ Less
Submitted 22 July, 2014;
originally announced July 2014.