Interference suppression techniques for OPM-based MEG: Opportunities and challenges
Authors:
Robert A Seymour,
Nicholas Alexander,
Stephanie Mellor,
George C O'Neill,
Tim M Tierney,
Gareth R Barnes,
Eleanor A Maguire
Abstract:
One of the primary technical challenges facing magnetoencephalography (MEG) is that the magnitude of neuromagnetic fields is several orders of magnitude lower than interfering signals. Recently, a new type of sensor has been developed - the optically pumped magnetometer (OPM). These sensors can be placed directly on the scalp and move with the head during participant movement, making them wearable…
▽ More
One of the primary technical challenges facing magnetoencephalography (MEG) is that the magnitude of neuromagnetic fields is several orders of magnitude lower than interfering signals. Recently, a new type of sensor has been developed - the optically pumped magnetometer (OPM). These sensors can be placed directly on the scalp and move with the head during participant movement, making them wearable. This opens up a range of exciting experimental and clinical opportunities for OPM-based MEG experiments, including paediatric studies, and the incorporation of naturalistic movements into neuroimaging paradigms. However, OPMs face some unique challenges in terms of interference suppression, especially in situations involving mobile participants, and when OPMs are integrated with electrical equipment required for naturalistic paradigms, such as motion capture systems. Here we briefly review various hardware solutions for OPM interference suppression. We then outline several signal processing strategies aimed at increasing the signal from neuromagnetic sources. These include regression-based strategies, temporal filtering and spatial filtering approaches. The focus is on the practical application of these signal processing algorithms to OPM data. In a similar vein, we include two worked-through experiments using OPM data collected from a whole-head sensor array. These tutorial-style examples illustrate how the steps for suppressing external interference can be implemented, including the associated data and code so that researchers can try the pipelines for themselves. With the popularity of OPM-based MEG rising, there will be an increasing need to deal with interference suppression. We hope this practical paper provides a resource for OPM-based MEG researchers to build upon.
△ Less
Submitted 29 November, 2021; v1 submitted 6 October, 2021;
originally announced October 2021.
Is Bonferroni correction more sensitive than Random Field Theory for most fMRI studies?
Authors:
Tim M. Tierney,
Christopher A. Clark,
David W. Carmichael
Abstract:
Random Field Theory has been used in the fMRI literature to address the multiple comparisons problem. The method provides an analytical solution for the computation of precise p-values when its assumptions are met. When its assumptions are not met the thresholds generated by Random Field Theory can be more conservative than Bonferroni corrections, which are arguably too stringent for use in fMRI.…
▽ More
Random Field Theory has been used in the fMRI literature to address the multiple comparisons problem. The method provides an analytical solution for the computation of precise p-values when its assumptions are met. When its assumptions are not met the thresholds generated by Random Field Theory can be more conservative than Bonferroni corrections, which are arguably too stringent for use in fMRI. As this has been well documented theoretically it is surprising that a majority of current studies (~80%) would not meet the assumptions of Random Field Theory and therefore would have reduced sensitivity. Specifically most data is not smooth enough to meet the good lattice assumption. Current studies smooth data on average by twice the voxel size which is rarely sufficient to meet the good lattice assumption. The amount of smoothing required for Random Field Theory to produce accurate p-values increases with image resolution and decreases with degrees of freedom. There is no rule of thumb that is valid for all study designs but for typical data (3mm resolution, and greater than 20 subjects) residual smoothness with FWHM = 4 times voxel size should produce valid results. However, it should be stressed that for higher spatial resolution and lower degrees of freedom the critical smoothness required will increase sharply. This implies that researchers should carefully choose appropriate smoothing kernels. This can be facilitated by the simulations we provide that identify the critical smoothness at which the application of RFT becomes appropriate. For some applications such as presurgical map** or, imaging of small structures, probing the laminar/columnar structure of the cortex these smoothness requirements may be too great to preserve spatial structure. As such, this study suggests developments are needed in Random Field Theory to fully exploit the resolution of modern neuroimaging.
△ Less
Submitted 27 July, 2016;
originally announced July 2016.