-
Multispectral CCD-in-CMOS Time Delay Integration imager for high resolution Earth observation
Authors:
Swaraj Bandhu Mahato,
Steven Thijs,
Jonas Bentell,
Linkun Wu,
Klaas Tack,
Pierre Boulenc,
Dorian Lasnet,
Renaud Van Langendonck,
Piet De Moor
Abstract:
Many future small satellite missions are aimed to provide low-cost remote sensing data at unprecedented revisit rates, with a ground resolution of less than one meter. This requires high resolution, fast and sensitive line-scan imagers operating at low power consumption and ideally featuring spectral sensitivity. In this paper we present comprehensive characterization results of our 7 band Back-Si…
▽ More
Many future small satellite missions are aimed to provide low-cost remote sensing data at unprecedented revisit rates, with a ground resolution of less than one meter. This requires high resolution, fast and sensitive line-scan imagers operating at low power consumption and ideally featuring spectral sensitivity. In this paper we present comprehensive characterization results of our 7 band Back-Side Illuminated (BSI) CCD-in-CMOS sensor with a pixel pitch of 5.4 um. We have extensively characterized the key performance parameters of our CCD-in-CMOS sensor, such as quantum efficiency (QE), full well capacity (FWC), read noise, conversion gain, non-linearity, dark current etc. Novelty of this device is the combination of 7 TDI bands on the same imager allowing simultaneous multispectral TDI capture. Glass-based broadband filters with a typical band-pass width of about 100 nm have been developed and glued together to form a filter assembly of 6 band-pass filters and one panchromatic channel. Multispectral capability of this sensor is particularly interesting for Low Earth Observation (LEO) applications such as environmental monitoring, precision agriculture, disaster detection and monitoring. To highlight its ad-vantages for use in vegetation observation, we demonstrated a fake leaf and a real leaf imaging using a 7 band BSI sensor with integrated filters operating in 7-band mode at 15 kHz.
△ Less
Submitted 29 September, 2021;
originally announced September 2021.
-
Cable bacteria as long-range biological semiconductors
Authors:
Robin Bonné,
Ji-Ling Hou,
Jeroen Hustings,
Mathijs Meert,
Silvia Hidalgo-Martinez,
Rob Cornelissen,
Jan D'Haen,
Sofie Thijs,
Jaco Vangronsveld,
Roland Valcke,
Bart Cleuren,
Filip J. R. Meysman,
Jean V. Manca
Abstract:
Filamentous cable bacteria exhibit unprecedented long-range biological electron transport, which takes place in a parallel fibre structure that shows an extraordinary electrical conductivity for a biological material. Still, the underlying electron transport mechanism remains undisclosed. Here we determine the intrinsic electrical properties of individual cable bacterium filaments. We retrieve an…
▽ More
Filamentous cable bacteria exhibit unprecedented long-range biological electron transport, which takes place in a parallel fibre structure that shows an extraordinary electrical conductivity for a biological material. Still, the underlying electron transport mechanism remains undisclosed. Here we determine the intrinsic electrical properties of individual cable bacterium filaments. We retrieve an equivalent electrical circuit model, characterising cable bacteria as resistive biological wires. Temperature dependent experiments reveal that the charge transport is thermally activated, and can be described with an Arrhenius-type relation over a broad temperature range (-196°C to +50°C), thus excluding metal-like electron transport. Furthermore, when cable bacterium filaments are utilized as the channel in a field-effect transistor, they show n-type transport, indicating that electrons rather than holes are the charge carriers. Electron mobilities are in the order of 10$^{-1}$ cm$^2$/Vs, comparable to many organic semiconductors. This new type of biological centimetre-range semiconductor with low resistivity offers new perspectives for both fundamental studies and applications in (bio)electronics.
△ Less
Submitted 12 December, 2019;
originally announced December 2019.
-
Active minimization of non-common path aberrations in long-exposure imaging of exoplanetary systems
Authors:
Garima Singh,
Raphaël Galicher,
Pierre Baudoz,
Olivier Dupuis,
Manuel Ortiz,
Axel Potier,
Simone Thijs,
Elsa Huby
Abstract:
Context. Spectroscopy of exoplanets is very challenging because of the high star-planet contrast. A technical difficulty in the design of imaging instruments is the noncommon path aberrations (NCPAs) between the adaptive optics (AO) sensing and the science camera, which induce planet-resembling stellar speckles in the coronagraphic science images. In an observing sequence of several long exposures…
▽ More
Context. Spectroscopy of exoplanets is very challenging because of the high star-planet contrast. A technical difficulty in the design of imaging instruments is the noncommon path aberrations (NCPAs) between the adaptive optics (AO) sensing and the science camera, which induce planet-resembling stellar speckles in the coronagraphic science images. In an observing sequence of several long exposures, quickly evolving NCPAs average out and leave behind an AO halo that adds photon noise to the planet detection. Static NCPA can be calibrated a posteriori using differential imaging techniques. However, NCPAs that evolve during the observing sequence do not average out and cannot be calibrated a posteriori. These quasi-static NCPAs are one of the main limitations of the current direct imaging instruments such as SPHERE, GPI, and SCExAO.
Aims. Our aim is to actively minimize the quasi-static speckles induced in long-exposure images. To do so, we need to measure the quasi-static speckle field above the AO halo.
Methods. The self-coherent camera (SCC) is a proven technique which measures the speckle complex field in the coronagraphic science images. It is routinely used on the THD2 bench to reach contrast levels of <10^{-8} in the range 5-12 λ/D in space-related conditions. To test the SCC in ground conditions on THD2, we optically simulated the residual aberrations measured behind the SPHERE/VLT AO system under good observing conditions.
Results. We demonstrate in the laboratory that the SCC can minimize the quasi-static speckle intensity in the science images down to a limitation set by the AO halo residuals. The SCC reaches 1σ raw contrast levels below 10^{-6} in the region 5-12 λ/D at 783.25 nm in our experiments.
△ Less
Submitted 1 October, 2019;
originally announced October 2019.
-
Status and performance of the THD2 bench in multi-deformable mirror configuration
Authors:
Pierre Baudoz,
Raphael Galicher,
Fabien Patru,
Olivier Dupuis,
Simone Thijs
Abstract:
The architecture of exoplanetary systems is relatively well known inward to 1 AU thanks to indirect techniques, which have allowed characterization of thousands of exoplanet orbits, masses and sometimes radii. The next step is the characterization of exoplanet atmospheres at long period, which requires direct imaging capability. While the characterization of a handful of young giant planets is fea…
▽ More
The architecture of exoplanetary systems is relatively well known inward to 1 AU thanks to indirect techniques, which have allowed characterization of thousands of exoplanet orbits, masses and sometimes radii. The next step is the characterization of exoplanet atmospheres at long period, which requires direct imaging capability. While the characterization of a handful of young giant planets is feasible with dedicated instruments like SPHERE/VLT, GPI/Gemini, SCExAO/Subaru and soon with the coronagraphic capabilities aboard JWST, the spectroscopic study of mature giant planets and lower mass planets (Neptune-like, Super Earths) requires the achievement of better coronagraphic performance. While space-based coronagraph on WFIRST-AFTA might start this study at low spectroscopic resolution, dedicated projects on large space telescope and on the ELT will be required for a more complete spectroscopic study of these faint planets. To prepare these future instruments, we developed a high contrast imaging bench called THD, then THD2 for the upgraded version using multi-DM configuration. The THD2 bench is designed to test and compare coronagraphs as well as focal plane wavefront sensors and wavefront control techniques. It can simulate the beam provided by a space telescope and soon the first stage of adaptive optics behind a ground-based telescope. In this article, we describe in details the THD2 bench and give the results of a recent comparison study of the chromatic behavior for several coronagraph on the THD2.
△ Less
Submitted 19 January, 2018;
originally announced January 2018.