Time-of-Flight X-ray Measurements for Computed Tomography
Authors:
Gaëtan Lemaire,
Romain Espagnet,
Julien Rossignol,
Louis-Daniel Gaulin,
Edouard Villemure,
Audrey Corbeil Therrien,
Yves Bérubé-Lauzière,
Marc-André Tétrault,
Réjean Fontaine
Abstract:
Time-of-flight (ToF) measurements is a possible alternative to anti-scatter grids in computed tomography (CT). Simulations have shown a possible 75% reduction in the detrimental scattering contribution with a 100 ps FWHM timing resolution. A test bench comprising a pulsed X-ray source and a time-correlated detector has been designed to demonstrate the feasibility of time-of-flight measurements of…
▽ More
Time-of-flight (ToF) measurements is a possible alternative to anti-scatter grids in computed tomography (CT). Simulations have shown a possible 75% reduction in the detrimental scattering contribution with a 100 ps FWHM timing resolution. A test bench comprising a pulsed X-ray source and a time-correlated detector has been designed to demonstrate the feasibility of time-of-flight measurements of X-rays using readout electronics inherited from a ToF-positron emission tomography project. A 86 ps FWHM coincidence time resolution have been achieved with 511 keV annihilation gamma-rays and a 155 ps FWHM timing jitter with a 120 kVp pulsed X-rays source.
△ Less
Submitted 29 November, 2023;
originally announced November 2023.
Ultrafast Radiographic Imaging and Tracking: An overview of instruments, methods, data, and applications
Authors:
Zhehui Wang,
Andrew F. T. Leong,
Angelo Dragone,
Arianna E. Gleason,
Rafael Ballabriga,
Christopher Campbell,
Michael Campbell,
Samuel J. Clark,
Cinzia Da Vià,
Dana M. Dattelbaum,
Marcel Demarteau,
Lorenzo Fabris,
Kamel Fezzaa,
Eric R. Fossum,
Sol M. Gruner,
Todd Hufnagel,
Xiaolu Ju,
Ke Li,
Xavier Llopart,
Bratislav Lukić,
Alexander Rack,
Joseph Strehlow,
Audrey C. Therrien,
Julia Thom-Levy,
Feixiang Wang
, et al. (3 additional authors not shown)
Abstract:
Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes, fundamental to nuclear fusion energy, advanced manufacturing, green transportation and others, often involve one mole or more atoms, and t…
▽ More
Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes, fundamental to nuclear fusion energy, advanced manufacturing, green transportation and others, often involve one mole or more atoms, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: a.) Detectors; b.) U-RadIT modalities; c.) Data and algorithms; and d.) Applications. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification, and U-RadIT optimization.
△ Less
Submitted 4 September, 2023; v1 submitted 21 August, 2023;
originally announced August 2023.
Billion-pixel X-ray camera (BiPC-X)
Authors:
Zhehui Wang,
Kaitlin Anagnost,
Cris W. Barnes,
D. M. Dattelbaum,
Eric R. Fossum,
Eldred Lee,
Jifeng Liu,
J. J. Ma,
W. Z. Meijer,
Wanyi Nie,
C. M. Sweeney,
Audrey C. Therrien,
Hsinhan Tsai,
Xin Que
Abstract:
The continuing improvement in quantum efficiency (above 90% for single visible photons), reduction in noise (below 1 electron per pixel), and shrink in pixel pitch (less than 1 micron) motivate billion-pixel X-ray cameras (BiPC-X) based on commercial CMOS imaging sensors. We describe BiPC-X designs and prototype construction based on flexible tiling of commercial CMOS imaging sensors with millions…
▽ More
The continuing improvement in quantum efficiency (above 90% for single visible photons), reduction in noise (below 1 electron per pixel), and shrink in pixel pitch (less than 1 micron) motivate billion-pixel X-ray cameras (BiPC-X) based on commercial CMOS imaging sensors. We describe BiPC-X designs and prototype construction based on flexible tiling of commercial CMOS imaging sensors with millions of pixels. Device models are given for direct detection of low energy X-rays ($<$ 10 keV) and indirect detection of higher energies using scintillators. Modified Birks's law is proposed for light-yield nonproportionality in scintillators as a function of X-ray energy. Single X-ray sensitivity and spatial resolution have been validated experimentally using laboratory X-ray source and the Argonne Advanced Photon Source. Possible applications include wide field-of-view (FOV) or large X-ray aperture measurements in high-temperature plasmas, the state-of-the-art synchrotron, X-ray Free Electron Laser (XFEL), and pulsed power facilities.
△ Less
Submitted 5 January, 2021;
originally announced January 2021.